Search PubMed⌕ Search

Biomedical subjects

T Nielsen

Publications and source records attributed to T Nielsen.

At least 19 recordsLinked to original sources

Os acromiale: population differences and their etiological significance.

The os acromiale is an accessory bone resulting from failure of the acromial apophysis to fuse to the scapula. It is a relatively frequent defect affecting 4-18% of most large skeletal series. The etiology of os acromiale is poorly understood, and two competing hypotheses have been proposed: (1) that the accessory bone represents a genetic defect, and (2) that it results from mechanical stress on the developing acromion. In order to assess the evidence for these two hypotheses, os acromiale frequencies from a South African cadaver sample (n = 494) were compared to frequencies from a medieval Danish archaeological sample (n = 532). The South African frequency (18.2%) was significantly higher than the medieval Danish frequency (7.7%, p < 0.0001). These results mirror those of another study comparing African- and Euro-Americans, and tend to support the genetic hypothesis. However, a left side bias (72%) was also found among the South Africans (p = 0.013), lending some support to the mechanical stress hypothesis. Sex and age biases were also examined but were not found. In order to further test the mechanical hypothesis, the medieval Danes were divided into groups of higher and lower socioeconomic status based upon cemetery type. Lower status individuals were presumed to have engaged in strenuous labor activities more often and at a younger age than higher status individuals. However, comparison of these two groups failed to demonstrate a significant frequency difference (p = 0.105). Based on the results of this study, it is suggested that a third etiology combining a genetic predisposition for os acromiale with mechanical stress as the proximate cause should also be considered.

Acromion↗

Identification of chemicals, possibly originating from misuse of refillable PET bottles, responsible for consumer complaints about off-odours in water and soft drinks.

Mineral water and soft drinks with a perceptible off-odour were analysed to identify contaminants originating from previous misuse of the refillable polyethylene terephthalate (PET) bottle. Consumers detected the off-odour after opening the bottle and duly returned it with the remaining content to the producers. The contaminants in question had thus been undetected by the in-line detection devices (so-called 'sniffers') that are supposed to reject misused bottles. GC-MS analysis was carried out on the headspace of 31 returned products and their corresponding reference products, and chromatograms were compared to find the possible off-odour compounds. Substances believed to be responsible for the organoleptic change were 2-methoxynaphthalene (10 bottles), dimethyl disulfide (4), anethole (3), petroleum products (4), ethanol with isoamyl alcohol (1) and a series of ethers (1). The mouldy/musty odour (5 bottles) was caused by trichloroanisole in one instance. In some cases, the origins of the off-odours are believed to be previous consumer misuse of food products (liquorice-flavoured alcohol, home-made alcohol containing fusel oil) or non-food products (cleaning products, petroleum products, oral moist snuff and others). The results also apply to 1.5-litre recyclable PET bottles, since the nature and extent of consumer misuse can be expected to be similar for the two bottle types.

Allylbenzene Derivatives↗

Cardiac cone-beam CT volume reconstruction using ART.

Modern computed tomography systems allow volume imaging of the heart. Up to now, approximately two-dimensional (2D) and 3D algorithms based on filtered backprojection are used for the reconstruction. These algorithms become more sensitive to artifacts when the cone angle of the x-ray beam increases as it is the current trend of computed tomography (CT) technology. In this paper, we investigate the potential of iterative reconstruction based on the algebraic reconstruction technique (ART) for helical cardiac cone-beam CT. Iterative reconstruction has the advantages that it takes the cone angle into account exactly and that it can be combined with retrospective cardiac gating fairly easily. We introduce a modified ART algorithm for cardiac CT reconstruction. We apply it to clinical cardiac data from a 16-slice CT scanner and compare the images to those obtained with a current analytical reconstruction method. In a second part, we investigate the potential of iterative reconstruction for a large area detector with 256 slices. For the clinical cases, iterative reconstruction produces excellent images of diagnostic quality. For the large area detector, iterative reconstruction produces images superior to analytical reconstruction in terms of cone-beam artifacts.

Algorithms↗

Phylogenetic analysis and in situ identification of the intestinal microbial community of rainbow trout (Oncorhynchus mykiss, Walbaum).

AIMS: To identify the dominant culturable and nonculturable microbiota of rainbow trout intestine. METHODS AND RESULTS: Microbial density of rainbow trout intestine was estimated by direct microscopic counts (4',6-diamidino-2-phenylindole, DAPI) and by culturing on tryptone soya agar (TSA). Differential gradient gel electrophoresis analysis of bacterial DNA from intestinal samples, re-amplification of bands and sequence analysis was used to identify the bacteria that dominated samples where aerobic counts were < or =2% of the DAPI counts. 16S rDNA gene sequences of 146 bacterial isolates and three sequences of uncultured bacteria were identified. A set of oligonucleotide probes was constructed and used to detect and enumerate the bacterial community structure of the gastrointestinal tract of rainbow trout by fluorescence in situ hybridization (FISH). Members of the gamma subclass of Proteobacteria (mainly Aeromonas and Enterobacteriaceae) dominated the bacterial population structure. Acinetobacter, Pseudomonas, Shewanella, Plesiomonas and Proteus were also identified together with isolates belonging to the beta subclass of Proteobacteria and Gram-positive bacteria with high and low DNA G + C content. In most samples, the aerobic count (on TSA) was 50-90% of the direct (DAPI) count. A bacterium representing a previously unknown phylogenetic lineage with only 89% 16S rRNA gene sequence similarity to Anaerofilum pentosovorans was detected in intestinal samples where aerobic counts were < or =2% of direct (DAPI) counts. Ten to 75% of the microbial population in samples with low aerobic counts hybridized (FISH) with a probe constructed against this not-yet cultured bacterium. CONCLUSIONS: Proteobacteria belonging to the gamma subclass dominated the intestinal microbiota of rainbow trout. However, in some samples the microflora was dominated by uncultivated, presumed anaerobic, micro-organisms. The bacterial population structure of rainbow trout intestine, as well as total bacterial counts, varied from fish to fish. SIGNIFICANCE AND IMPACT OF THE STUDY: Good correlation was seen between cultivation results and in situ analysis, however, a molecular approach was crucial for the identification of organisms uncultivated on TSA.

Animals↗

Migration of model contaminants from PET bottles: influence of temperature, food simulant and functional barrier.

To simulate post-consumer recycled plastics, selected model contaminants were incorporated into PET bottles using a time saving method. Migration into 3% acetic acid, a cola-type beverage and 95% ethanol was followed during 1 year of storage at 20 and 40 degrees C. Aroma compounds previously found in post-consumer PET material were used as model contaminants. Benzaldehyde was found to migrate to the highest extent. Storage at 40 degrees C affected the bottle material and this might be one reason for the high migration values of these bottles. Migration into ethanol was up to 20 times higher than into 3% acetic acid or a cola-type beverage. Bottles with a functional barrier resisted migration into food simulants even when filled with 95% ethanol and stored for 1 year at 40 degrees C. Differential scanning calorimetry measurements showed that ethanol was interacting with the plastic material. This resulted in a lower glass transition temperature of bottles stored with ethanol compared with bottles stored empty or with other food simulants.

Acetic Acid↗

Safety and efficacy of drospirenone used in a continuous combination with 17beta-estradiol for prevention of postmenopausal osteoporosis.

OBJECTIVE: To evaluate the combination of 17beta-estradiol and continuous drospirenone for the prevention of postmenopausal osteoporosis. METHODS: A total of 180 (75%) healthy postmenopausal women aged 45-65 years completed a 2-year prospective study. Bone mineral density (BMD) at lumbar spine, hip and total body as well as endometrial thickness, markers of bone turnover and serum lipids were measured regularly. Treatment groups were given placebo or 1 mg 17beta-estradiol combined with 1, 2 or 3 mg drospirenone daily. RESULTS: BMD at the lumbar spine, hip and total body increased by 7, 4 and 3%, respectively, in all hormone groups versus placebo (all p < 0.001). Bone markers all decreased accordingly (serum osteocalcin 52%, serum bone specific alkaline phosphatase 36%, serum CrossLaps 67% and urinary CrossLaps 75% from baseline; all p < 0.001). Total cholesterol and low-density lipoprotein cholesterol decreased by 8% and 13%, respectively (both p < 0.001). High-density lipoprotein cholesterol and triglycerides remained unchanged. No significant dose-related effects were found. Endometrial thickness increased by 1.2 mm only in the 1-mg drospirenone group (p < 0.01 versus placebo). CONCLUSION: The combination of 17beta-estradiol and drospirenone has a positive effect on BMD and a potentially beneficial effect on lipids. Although endometrial thickness increased slightly, the safety of the endometrium was assured, as no cases of hyperplasia or cancer occurred.

Aged↗

Automatic phase determination for retrospectively gated cardiac CT.

The recent improvements in CT detector and gantry technology in combination with new heart rate adaptive cone beam reconstruction algorithms enable the visualization of the heart in three dimensions at high spatial resolution. However, the finite temporal resolution still impedes the artifact-free reconstruction of the heart at any arbitrary phase of the cardiac cycle. Cardiac phases must be found during which the heart is quasistationary to obtain outmost image quality. It is challenging to find these phases due to intercycle and patient-to-patient variability. Electrocardiogram (ECG) information does not always represent the heart motion with an adequate accuracy. In this publication, a simple and efficient image-based technique is introduced which is able to deliver stable cardiac phases in an automatic and patient-specific way. From low-resolution four-dimensional data sets, the most stable phases are derived by calculating the object similarity between subsequent phases in the cardiac cycle. Patient-specific information about the object motion can be determined and resolved spatially. This information is used to perform optimized high-resolution reconstructions at phases of little motion. Results based on a simulation study and three real patient data sets are presented. The projection data were generated using a 16-slice cone beam CT system in low-pitch helical mode with parallel ECG recording.

Algorithms↗

Helical cardiac cone beam reconstruction using retrospective ECG gating.

In modern computer tomography (CT) systems, the fast rotating gantry and the increased detector width enable 3D imaging of the heart. Cardiac volume CT has a high potential for non-invasive coronary angiography with high spatial resolution and short scan time. Due to the increased detector width, true cone beam reconstruction methods are needed instead of adapted 2D reconstruction schemes. In this paper, the extended cardiac reconstruction method is introduced. It integrates the idea of retrospectively gated cardiac reconstruction for helical data acquisition into a cone beam reconstruction framework. It leads to an efficient and flexible algorithmic scheme for the reconstruction of single- and multi-phase cardiac volume datasets. The method automatically adapts the number of cardiac cycles used for the reconstruction. The cone beam geometry is fully taken into account during the reconstruction process. Within this paper, results are presented on patient datasets which have been acquired using a 16-slice cone beam CT system.

Algorithms↗

Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction.

Cone beam computed tomography scanners in combination with heart rate adaptive reconstruction schemes have the potential to enable cardiac volumetric computed tomography (CT) imaging for a larger number of patients and applications. In this publication, an adaptive scheme for the automatic and patient-specific reconstruction optimization is introduced to improve the temporal resolution and image quality. The optimization method permits the automatic determination of the required amount of gated helical cone beam projection data for the reconstruction volume. It furthermore allows one to optimize subvolume reconstruction yielding an increased temporal resolution. In addition, methods for the assessment of the temporal resolution are given which enable a quantitative documentation of the reconstruction improvements. Results are presented for patient data sets acquired in low pitch helical mode using a 16-slice cone beam CT system with parallel ECG recording.

Algorithms↗

Hyperspectral imaging: a novel approach for microscopic analysis.

BACKGROUND: The usefulness of the light microscope has been dramatically enhanced by recent developments in hardware and software. However, current technologies lack the ability to capture and analyze a high-resolution image representing a broad diversity of spectral signatures in a single-pass view. We show that hyperspectral imaging offers such a technology. METHODS AND RESULTS We developed a prototype hyperspectral imaging microscope capable of collecting the complete emission spectrum from a microscope slide. A standard epifluorescence microscope was optically coupled to an imaging spectrograph, with output recorded by a CCD camera. Software was developed for image acquisition and computer display of resultant X--Y images with spectral information. Individual images were captured representing Y-wavelength planes, with the stage successively moved in the X direction, allowing an image cube to be constructed from the compilation of generated scan files. This prototype instrument was tested with samples relevant to cytogenetic, histologic, cell fusion, microarray scanning, and materials science applications. CONCLUSIONS: Hyperspectral imaging microscopy permits the capture and identification of different spectral signatures present in an optical field during a single-pass evaluation, including molecules with overlapping but distinct emission spectra. This instrument can reduce dependence on custom optical filters and, in future imaging applications, should facilitate the use of new fluorophores or the simultaneous use of similar fluorophores.

Humans↗

Photodegradation of nitro-PAHs in viscous organic media used as models of organic aerosols.

Many types of organic aerosol material have been found to behave as viscous liquids. In the current work, photodegradation of selected nitrated polycyclic aromatic compounds, 1-nitropyrene and 3-nitrofluoranthene, in viscous organic phases used as model systems for organic aerosols has been investigated. Experiments have been conducted in the presence and absence of anthraquinone, an atmospherically relevant photochemical radical sensitizer. The photodegradation of nitro-PAH is strongly accelerated by the presence of anthraquinone, and a viscous medium does not inhibit the photoinduced decay of nitro-PAH. In fact, the effect of anthraquinone is more pronounced in a viscous solvent containing tertiary hydrogen, DOP, compared to cyclohexane, a nonviscous solvent. This is related to a faster decay of anthraquinone in DOP and hence, presumably, a higher radical yield in DOP. The nitro-PAH degradation in DOP is faster at higher temperature; an observation primarily ascribed to faster diffusion at higher temperature giving rise to more efficient radical formation. In glycerine, a polar viscous solvent, significant formation of amino-PAH occurs due to photoreduction of the nitro-PAH. This is also the case in N2-purged guaiacol, a model substance for wood smoke organic material. Nitro-PAH photoreduction is enabled by the presence of hydrogen-atom donors and low levels of dissolved O2. A simple approach to estimate the O2 concentration in atmospheric organic aerosol material is presented. Low levels of O2 are predicted for wood smoke and secondary organic aerosol making amino-PAH formation in this aerosol material an interesting possibility.

Aerosols↗

High efficiency beam splitter for multifocal multiphoton microscopy.

In this article we present the development of a multibeam two-photon laser scanning microscope. A new type of beam splitter to create the multitude of laser beams is described. This type of beam splitter has higher transmission and generates more uniform beams than can be achieved with the microlens approach used by other groups. No crosstalk exists between the different foci due to small temporal delays between the individual beams. The importance of dispersion compensation to obtain maximum efficiency of the microscope is discussed. With optimum compensation the fluorescence signal was raised by a factor of 14. Different modes of detecting the fluorescence signals and their effect on imaging speed and resolution are discussed.

Animals↗

Effects of eight polycyclic aromatic compounds on the survival and reproduction of the springtail Folsomia fimetaria L. (Collembola, isotomidae).

The effects of eight polycyclic aromatic compounds on the survival and reproduction of the collembolan Folsomia fimetaria L. were investigated in a well-characterized Danish agricultural soil. With the exception of acridine, polycyclic aromatic hydrocarbons (PAHs) and neutral N-, S-, and O-monosubstituted analogues showed similar toxicities to soil collembolans when the results were expressed in relation to total soil concentrations (mg/kg). The estimated concentrations resulting in a 10% reduction of reproductive output (EC10 values) were based on measured initial concentrations and were for acridine 290 mg/kg, carbazole 10 mg/kg, dibenzofuran 19 mg/kg, dibenzothiophene 7.8 mg/kg, fluoranthene 37 mg/kg, fluorene 7.7 mg/kg, phenantrene 23 mg/kg, and pyrene 10 mg/kg. When the EC10 values were converted to soil pore-water concentrations, they showed a highly significant correlation (r2 = 0.71, p < 0.01) to no-observed-effect concentrations for the freshwater crustacean Daphnia magna, as estimated by a quantitative structure activity relation (QSAR) for baseline toxicity (nonpolar narcosis). Only carbazole and acridine were more than two times more toxic (4.9 and 3.1, respectively) than expected from the Daphnia QSAR data. The latter result indicates that the toxicity of the tested substances is close to that expected for compounds with nonpolar narcosis as the mode of action. However, the relatively large uncertainties in the extrapolation method prevent final conclusions from being drawn.

Animals↗

[Placebo effect in the drug therapy of depression].

This paper estimates the effect sizes of placebo treatment of depression from meta-analyses of antidepressive medicine, and examines methodological artifacts in antidepressive research. It is concluded that between one-half and two-thirds of the effects of antidepressive medicine are explained by placebo response with a mean difference between treatment and placebo groups around 25 percent. This modest effect size should probably be adjusted for methodological bias due to incomplete blindness and other sources of error favouring the medicine group. Some practical consequences of the fact that depression is a placebo sensitive disorder are outlined.

Antidepressive Agents↗

Sleep in right hemispherectomized patients: evidence of electrophysiological compensation.

OBJECTIVES: The goal of this study is to provide a better understanding of the role of the cortex in sleep's macro- and microstructure modulation. METHODS: Sleep architecture and phasic events were investigated in 4 patients having undergone right functional or anatomical hemispherectomy and 8 control subjects. Between-groups differences were assessed using the Wilcoxon-Mann-Whitney test. RESULTS: Findings provide evidence for overall similarity between patients' and control subjects' left hemispheric sleep architecture. In addition, results clearly indicate that it is possible to detect electrical activity over the operated side of a hemispherectomized patient's brain, even when resection of the hemi-cortex has been complete. Finally, findings provide evidence for similar left and right hemispheric relative spectral activities and for an increase in fast activity bands over the intact hemisphere in anatomical hemispherectomized patients. CONCLUSIONS: This study provides evidence that right hemispherectomy does not produce significant sleep architecture alterations as recorded over the intact hemisphere. In addition, residual activity detected over the operated side in anatomical hemispherectomized patients is interpreted as resulting from volume conduction originating from generators located in the intact hemisphere. Finally, there is strong evidence for electrophysiological compensation in the intact hemisphere following complete resection of the contralateral hemi-cortex.

Adolescent↗