Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive series of 8 patients were operated on for giant cerebral aneurysms with the combined use of deep hypothermia. The protocol included careful preoperative cardiovascular assessment, perfect intraoperative synergy between neurosurgical and cardiac teams, minimally invasive peripheral vascular access including two femoral vein (21 F) and single arterial (17 F) femoral cannulation, use of total Carmeda coating on BioMedicus pumps in closed circuits, and reduced heparinization without Protamine reversal. All cerebral aneurysms were successfully treated through deep hypothermia (15-18 degrees C) as assessed by intraoperative fluoroscopic controls and Doppler vascular assessment. Mean circulatory support time was 174.2 +/- 29.6 min. Circulatory arrest period was 20 +/- 12 min. All patients survived and were extubated within 48 h. No major deficit was observed clinically or on postoperative CT scan. No hemorrhagic complications occurred (mean transfusions was 2.2 blood units). This work supports an extensive use of heparin-coated surfaces for complex circulatory assist techniques, either for cardiac or extra cardiac complex procedures.
The aim of this study was to demonstrate the clinical and biological benefits of heparin-coated circuits in routine coronary artery bypass grafting (CABG). A prospective, randomized study was conducted in 80 patients undergoing routine CABG. Patients were randomized to either noncoated circuits (Group 1) or heparin-coated circuits (Group 2). A complete clinical evaluation was performed preoperatively at Days 0, 1, 2, and 3 and at discharge day and combined with extensive laboratory tests for hemostasis and inflammatory response. This study did not prove any major statistically significant clinical benefit of heparin-coated circuits in low risk patients. Postoperative bleeding, significantly less in the heparin-coated group, did not decrease significantly the number of transfused patients. Biological values were not changed significantly except for factor II and monocytes, which were higher in Group 2. Heparin-coated circuits offer minimal clinical and biological benefits for routine CABG surgery. However, they may prove beneficial for complex procedures or at-risk patients.
Because radiation-induced coronary artery stenoses are frequently severe and located proximally, some patients are admitted in emergency. This report describes the case of a 47-year-old woman with radiation-induced stenosis of the left main coronary artery who presented with cardiac arrest during angiography. The patient was successfully treated using circulatory assistance and percutaneous transluminal coronary angioplasty as a bridge to coronary artery bypass grafting.
BACKGROUND AND AIM OF THE STUDY: The study aim was to analyze the results of reoperations for structural degeneration of bioprostheses, and to define a high-risk population for reoperative procedures. METHODS: A series of 524 consecutive patients who had undergone a first reoperative replacement for a failed bioprosthesis between 1978 and 1998 was reviewed retrospectively. The reoperative procedure comprised 363 single valve replacements, and 161 multiple valve replacements. During the original procedure, 648 bioprostheses had been implanted in the mitral (n = 403), aortic (n = 220) and tricuspid (n = 25) positions. RESULTS: The mean interval between the original procedure and reoperation was 8.8 +/- 3.3 years. Tissue valve failure was revealed by recurrence of cardiac insufficiency in 70% of cases. The overall early mortality rate was 8%, but early mortality rates for elective single mitral and aortic reoperative valve replacements were only 3.9% and 4%, respectively. Early mortality following reoperation for single and multiple valve replacement was 6.0% and 12.4% respectively (p = 0.02). Other significant multivariable predictors for early mortality were old age (p = 0.003), NYHA functional class (p = 0.007), presence of ascites (p = 0.02) and reoperation performed before 1988 (p = 0.013). CONCLUSIONS: The risk of reoperation for structural degeneration of bioprostheses is acceptable for elective single reoperative valve replacement as opposed to multiple reoperative valve replacement. This may limit the use of bioprostheses during the original procedure when multiple valve replacement is required.
Explore the source record for details and available documents.
The influence of the Wankel type semipulsatile left ventricular assistance on hemodynamics was investigated with a computer simulation and an animal experiment. A simulation circuit was constructed to express the circulatory system. A current source was added to create a semipulsatile blood pump. The left and right ventricles were replaced by variable compliances. Left heart failure was simulated by decreasing the amount of compliance change of the left ventricle. Under the condition of heart failure when semipulsatile assist flow increased, the mean aortic pressure (AoP), tension time index (TTI), and diastolic pressure time index (DPTI) increased, and the cardiac output, pulse pressure (PP), and pulsatility indicator (PI) decreased. In an animal experiment, a Wankel type blood pump was used in a calf. With the increase of the assist flow, AoP curves became less pulsatile, and PP and PI decreased in accordance, which was predicted by the numerical simulation.
Active aortic endocarditis is a serious condition that carries a high mortality and morbidity. The aim of this study was to analyse results obtained from 24 patients who underwent aortic valve or root replacement with cryopreserved homograft for aortic endocarditis. Eleven patients had native valve endocarditis, and 13 had prosthetic valve endocarditis. The mean age was 47.7 years: there were seven women and 17 men. Causative organisms were staphylococci (12), streptococci (four), serratia (one), candida (one), pneumococci (one), while no organisms were isolated in the remaining five patients. Complete reconstruction of the aortic annulus with homograft conduits was necessary in 20 patients (six total root and 14 mini-root). Infracoronary homograft aortic valve replacement was performed in the remaining patients. One patient died 1 day after the operation from ventricular failure, and two others died after 4 and 6 months as a result of arrhythmia. One patient died of recurrent endocarditis 1 year after surgery. The actuarial survival rate at 3 years was 83.4%. All survivors are symptom-free, with no evidence of recurrent endocarditis. Doppler echocardiography showed minimal aortic regurgitation in four patients.
Modifications of the diastolic parameters pressure half-time (PHT) and isovolumic relaxation time (IVRT), recorded using cardiac Doppler echocardiography (CDE), were studied in 23 heart transplant recipients and compared to the results of 345 endomyocardial biopsies (EMB) performed on the same day. Two different protocols, analyzing respectively (1) a decrease of 20% or more in IVRT and/or PHT with respect to the mean and (2) a decrease of 20% or more in IVRT and/ or PHT with respect to its preceding value, were used to evaluate the efficiency of CDE in diagnosing mild and moderate rejections. When a mild rejection was detected by EMB, a statistically significant decrease was found in the average CDE parameter values of the patient population. However, these variations were weak and did not differ from the spontaneous variations observed in each patient in the absence of rejection. Thus, it is not surprising that the sensitivity of CDE in the detection of mild rejections was very low (45%) using the most sensitive protocol (variations of the parameters from their preceding value). We conclude that CDE alone does not seem to be sufficient to perform the noninvasive diagnosis of low-grade rejections and must be complemented by other noninvasive methods.
For decades, research for developing a totally implantable artificial ventricle has been carried on. For 4 to 5 years, two devices have been investigated clinically. For many years, we have studied a rotary (but not centrifugal) pump that furnishes pulsatile flow without a valve and does not need external venting or a compliance chamber. It is a hypocycloidal pump based on the principle of the Maillard-Wankel rotary compressor. Currently made of titanium, it is activated by an electrical brushless direct-current motor. The motor-pump unit is totally sealed and implantable, without noise or vibration. This pump was implanted as a left ventricular assist device in calves. The midterm experiments showed good hemodynamic function. The hemolysis was low, but serious problems were encountered: blood components collecting on the gear mechanism inside the rotor jammed the pump. We therefore redesigned the pump to seal the gear mechanism. We used a double system to seal the open end of the rotor cavity with components polished to superfine optical quality. In addition, we developed a control system based on the study of the predicted shape of the motor current. The new design is now underway. We hope to start chronic experiments again in a few months. If the problem of sealing the bearing could be solved, the Cora ventricle could be used as permanent totally implantable left ventricular assist device.
We tested our valveless pulsatile rotary blood pump (CORA) extensively in animals, but only as a temporary implantable left ventricular assist device. To expand the scope of future clinical applications, we recently undertook experiments to assess the feasibility of our pump for use in a standard cardiopulmonary bypass circuit. We conducted 4 experiments in adult sheep (body weight, 40 kg): 2 with CORA and 2 with the BioMedicus pump (BP) for comparison. In all experiments, a currently used extracorporeal circuit with reservoir, filter, and membrane oxygenator (Sorin monolith) was installed, and open chest extracorporeal circulation (ECC) was performed for 6 h. Hemodynamic performance and hemolysis were evaluated. CORA provided semipulsatile systemic flow at a level comparable to that of the BP. Free plasma hemoglobin levels were slightly higher with CORA, but the decrease in platelet count was the same for both devices. There was no significant difference in the extent of blood trauma. We conclude that CORA could be successfully used for ECC with an oxygenator. Negative pressure can be prevented by our specially designed control system.
Use of cardiopulmonary support (CPS) by peripheral access with a membrane oxygenator has made considerable progress as a result of the development of centrifugal pumps, percutaneous cannulation, and preheparinized circuits. We have used CPS for resuscitation in 3 cases, for recovery after cardiotomy in 6 cases (myocardial insufficiency, 4; pulmonary arterial hypertension, 1; respiratory insufficiency, 1), and after heart transplantation in 1 case. Of these 10 patients, 3 died during CPS, 5 were successfully weaned, and 2 underwent heart transplantation. Use of CPS is expanding for emergency cardiac assistance. Installation is simple and rapid. It allows recovery of organs pending more invasive and costly techniques.
PURPOSE: To evaluate routine magnetic resonance (MR) imaging for long-term follow-up in patients who undergo surgery for type A aortic dissection. MATERIALS AND METHODS: Ninety-two MR examinations were performed in 36 patients. Standard spin-echo images were obtained with electrocardiographic gating (n = 92) and rapid images with a fast low-angle shot sequence and intravenous administration of gadopentetate dimeglumine (n = 25). All segments of the native thoracic aorta were evaluated. Anastomoses of the prosthesis and periprosthetic hematoma were carefully analyzed. RESULTS: Of 22 complications that occurred in 18 patients, 18 were diagnosed at MR imaging (nine false aneurysms and nine aneurysms distal to the graft). Nine patients underwent reoperation. The findings at MR imaging correlated with those at surgery. CONCLUSION: Routine follow-up with MR imaging should improve long-term survival in patients who survive emergency surgical repair of type A aortic dissection.
In order to determine the prognosis of reoperation for valvular replacement, we reviewed the results of a consecutive series of 124 patients operated in the department between 1974 and 1992 (163 multi redo operations). There were 69 women and 55 men, with a mean age 48 years; 77% of the patients were in functional class III or IV. Operations were performed as an emergency in 30% of cases. Endocarditis was found in 24% of cases and was an important risk factor in this content. The main indications for reoperation were periprosthetic leakage in 28.8% of cases and failure of bioprostheses in 23.7%. The valvular replacement was simple in 61%, double in 32% and triple in 7% of cases. An associated procedure was necessary in 27% of cases. Mechanical devices were implanted in 62.3% of cases. Peroperative mortality was 3% and hospital mortality, mainly from cardiac causes, was 21.7% for the second, 20% for the third and 55.6% for the fourth reoperations. Operative mortality was dependent on the number or reoperations, functional class, emergency surgery, duration of bypass and cross-clamping time. Four per cent of patients were lost to follow-up and 30 patients died secondarily. The actuarial survival rate was 52% at 5 years and 33% at 10 years, actuarial survival rate without valvular complication was 41% at 5 years and 19% at 10 years but the functional results remained good with over 90% of patients in functional class I or II at the end of follow-up.
Explore the source record for details and available documents.
We have developed a low-speed, double-lobed hypocycloidal pump that furnishes a pulsatile flow without valves. The pump is coupled to a specially designed electric motor. The motor/pump unit is totally implantable and has been extensively tested in vitro and in vivo in animals. Because this pump is volumetric, it is necessary to control speed precisely to avoid overpumping. Our control system, which is based on analysis of the motor current wave form, can detect and prevent negative pressures before they occur. The physical properties and hemocompatibility of several construction materials have been studied to determine their suitability for clinical use. These materials include a graphite substrate, titanium nitrate surface coating, boric carbon, and amorphous diamond. The pumps currently being tested are made of titanium, but clinical versions will be made of composite materials selected from this preliminary study. In vivo testing of this pump confirmed its good hemodynamic performance, low hemolysis rate, and biocompatibility (i.e., low heat, noise, and vibration levels). Animal experiments were terminated after 15 days because of mechanical failure related to the accumulation of blood components on moving parts. A new pump in which the mechanism is completely sealed from the blood flow has been designed and will soon be tested. If this sealed design is effective, the pump should be ready for use as a permanent implantable ventricular assistance device.
The case of a 44-year-old black man who presented with severe dysphagia, cough and chest pain caused by a 12-cm aneurysm developing from a Kommerell's diverticulum at the origin of an aberrant retro-oesophageal left subclavian artery is reported. The aortic arch and descending thoracic aorta were right sided. Diagnosis was established before operation by computed tomography, magnetic resonance imaging and arteriography. The aneurysm extended a considerable distance down the descending aorta and therefore the risk of postoperative paraplegia was considered to be high. Accordingly selective arteriography was performed to locate the Adamkievicz's artery which arose only 2 cm below the end of the aneurysm. Resection grafting of the aneurysm including the upper third of the descending aorta via right thoractomy was performed. The patient made an uneventful recovery and was discharged 20 days later. This case appears to be the first successful operation for this pathology.