Search PubMed⌕ Search

Biomedical subjects

T Meinertz

Publications and source records attributed to T Meinertz.

At least 55 records · Page 3Linked to original sources

Membrane-covered stents: a new treatment strategy for saphenous vein graft lesions.

The restenosis rate after stenting of lesions in aortocoronary venous bypass grafts still has to be considered unsatisfactorily high. We investigated a new stent design characterized by an expandable polytetrafluorethylene (PTFE) membrane in between two layers of struts. Five consecutive male patients (age 70 +/- 6 years) were followed prospectively who presented with at least two de novo lesions in different grafts 13 +/- 3 years after bypass surgery. A total of 11 lesions were treated located in grafts anastomosed to the circumflex (n = 3), to the LAD (n = 7), and to the right coronary artery (n = 1). Within the same procedure, every patient received membrane-covered stents (n = 6) and conventional stents (n = 5) in either of their lesions. All patients underwent successful interventions. The minimal luminal diameter increased from 1.0 +/- 0.5 to 2.9 +/- 0.6 mm in lesions treated by the membrane-covered stents and from 0.8 +/- 0.4 to 2.4 +/- 0.7 mm in the lesions treated by conventional stents. During follow-up, four out of five patients required angioplasty for in-stent restenosis of lesions covered by a conventional stent, whereas no patient underwent revascularization for a lesion treated by a membrane-covered device. The mean minimal luminal diameter of lesions covered by a conventional stent decreased by 42% to 1.4 +/- 0.6 mm; the mean minimal luminal diameter of the lesions treated by a stent graft declined by 9% to 2.8 +/- 0.6 mm (P < 0.05). This series of intraindividual comparisons suggests that membrane-covered stents may have the power to reduce in-stent restenosis in obstructed aortocoronary venous bypass grafts.

Aged↗

Optimized mapping of slow pathway ablation guided by subthreshold stimulation: a randomized prospective study in patients with recurrent atrioventricular nodal re-entrant tachycardia.

OBJECTIVES: This randomized prospective study sought to assess the value of slow pathway (SP) mapping and ablation guided by subthreshold stimulation (STS) in comparison with a strategy based on conventional criteria. BACKGROUND: Previous studies have demonstrated that STS can be used as a highly specific and sensitive marker for successful SP ablation in the setting of atrioventricular nodal re-entrant tachycardia (AVNRT). Nonetheless, thus far this mapping strategy has not been investigated in contrast with the conventional approach. METHODS: One hundred patients with sustained AVNRT were included. Fifty patients (group A) were randomly assigned to endocardial mapping and SP ablation using currently established criteria. In the other 50 patients (group B), SP ablation was guided by STS mapping. In group B patients, only radiofrequency current (RFC) was applied if additionally constant current STS (up to 5 mA) during AVNRT interrupted the tachycardia due to selective block within the SP. RESULTS: Termination of AVNRT without apparent capture was observed during STS in 47 of 50 group B patients (94%). In all cases, this effect was indicative for successful subsequent SP ablation. The mean number of RFC pulses required for successful SP ablation was significantly lower in patients assigned to the STS-guided strategy (1.6 +/- 1.3 vs. 3.9 +/- 3.4; p = 0.0003). Similarly, the mean procedure duration was shorter in the STS group (156.9 +/- 33.5 vs. 173.2 +/- 49.7 min; p = 0.0221); the fluoroscopy time was comparable between both groups (14.1 +/- 8.7 vs. 16.9 +/- 10.6 min; p = 0.1278). CONCLUSIONS: Subthreshold stimulation is an effective method for detection of target sites for selective SP ablation. This technique helps to minimize the number of RFC pulses without prolongation of the overall procedure and fluoroscopy time required for SP ablation.

Aged↗

Electroanatomical Mapping (CARTO) of ectopic atrial tachycardia: impact of bipolar and unipolar local electrogram annotation for localization the focal origin.

UNLABELLED: Electroanatomical Mapping (CARTO) allows a tridimensional localization of ectopic atrial tachycardia (EAT). No standardized recommendation exists for annotation the local activation time in EAT using this new technology. In the present study bipolar local electrogram were used for CARTO guided RF ablation of EAT. In comparison the same maps were retrospectively analyzed by annotation the unipolar local electrogram. METHODS: In 15 consecutive patients (6m, 51+/-14 y) with EAT CARTO mapping was guided by annotation the earliest onset of the bipolar local electrogram. Following successful RF ablation the obtained EAT maps were subsequently evaluated by annotation of the earliest steepest negative intrinsic deflection of the unipolar local electrogram. Both CARTO maps were compared with regard to the region of focal EAT origin. RESULTS: RF ablation of all 15 EAT foci guided by annotation the bipolar local electrogram with CARTO was successful with a median of 3 [1-18] pulses and a median fluoroscopy time of 10 min [4-25]. All but one focus was located in the right atrium: posterior to posteroinferior region of the terminal crest in 6, septal region in 5, anterior superior region in 3 cases. One left sided EAT was located at the septum. The bipolar CARTO map demonstrated a "small territory" location of earliest activation (extension of the focus < or =0.4 cm(2)) in 14 out of 15 patients. In a single patient the bipolar map showed several sites of earliest local activation (extension >0.4 cm(2)). On the other side the retrospectively achieved unipolar maps demonstrated an extended region of earliest local activation in 6 out of 15 patients (>0.4 cm(2)). CONCLUSIONS: CARTO maps of EAT by annotation the earliest onset of the bipolar local electrogram provide an efficacious guide for location the focal origin. Extended regions of earliest local activation in EAT might be rather determined by annotation the unipolar in comparison to the bipolar local electrogram.

Adult↗

Adjustment of the evoked response sensitivity after hospital discharge in pacemaker patients with automatic ventricular threshold tracking activated.

Automatic threshold tracking in cardiac pacemakers allows ventricular capture verification and self-adaptive pacing output regulation. The Autocapture algorithm detects the evoked response (ER) signal immediately after the pacing pulse to verify the efficacy of ventricular pacing. Before hospital delivery, the ER sensitivity must be programmed individually so that the pacemaker detects the ER signal adequately without sensing lead polarization. The aims of the study were to assess the frequency of patients in whom Autocapture could be activated and whether the ER sensitivity had to be adjusted after hospital discharge. The study included 44 patients who received the VVIR pacemaker Regency SR+ (St. Jude Medical) connected to the model 1450 T pacing lead. ER signal, lead polarization, and ER sensitivity were evaluated before hospital discharge and 1, 3, and 6 months after implantation. The system recommended activating Autocapture in 42 of 44 patients. The mean ER signal was 8.4+/-1.2 mV at discharge, 9.0+/-3.9 mV at month 1, 8.9+/-4.9 mV at month 3, and 9.3+/-4.5 mV at month 6. Polarization was 1.0+/-0.1 mV at discharge, 1.1+/-0.5 mV at month 1, 1.1+/-0.2 mV at month 3, and 1.1+/-0.5 mV at month 6. Mean ER sensitivity was 3.7+/-1.8 mV at discharge, 4.0+/-1.8 mV after 1, 4.1+/-2.2 mV after 3, and 4.1+/-1.8 mV after 6 months. ER sensitivity could remain unadjusted in 14 patients. Programming to a less sensitive ER setting from 2.9+/-1.2 mV to 4.3+/-1.5 mV was possible in 21 patients. Programming to a more sensitive ER setting from 4.1+/-1.1 mV to 2.5+/-0.9 mV was required in nine patients because of the decrease of the ER signal. The automatic threshold tracking algorithm Autocapture could be activated in 95% of patients. Programming to more sensitive ER settings was recommended in 21% of the patients after hospital discharge. Therefore, ER signal and polarization must be checked at each follow-up, as a decrease in ER signal amplitude can make reprogramming of the ER sensitivity necessary. There is no risk for the patient if the ER is not sensed, as high voltage backup stimulation is present.

Aged↗

Radiofrequency catheter ablation using long coiled electrodes: impact of irrigation on lesion dimensions and incidence of coagulum formation.

Ablation catheters with multiple long coiled electrodes have been recently developed to induce continuous linear lesions for the treatment of atrial fibrillation. The efficacy and safety of ablation catheters with multiple long coiled electrodes has not been evaluated. The aim of the present in vivo study was to investigate the influence of saline irrigation on lesion dimensions and coagulum formation during RF current ablation using those ablation catheters. In 14 anesthetized sheep, the thigh muscle was prepared as a cradle and filled with heparinized blood (37 degrees C). The quadripolar coiled ablation catheter (electrode length 7 mm, electrode distance 2 mm) was placed parallel to the muscle with standardized 10-g contact pressure. RF current energy was delivered sequentially temperature-(70 degrees C) or power-controlled (10, 20, 30, or 40 W) with additional irrigation of the electrode (10 mL/min normal saline) for 90 seconds. Forty-two of 129 RF current lesions were induced by temperature-controlled and 87 by irrigated ablation. Except for three lesions following low energy irrigated application (10 W), all lesions were continuous. Significantly larger lesions following irrigated RF current applications were produced with a power output of 30 W (depth 0.74 +/- 0.13 cm, width 0.78 +/- 0.13 cm) and 40 W (depth 0.75 +/- 0.16 cm, width 0.92 +/- 0.28 cm) as compared to 20 W (depth 0.47 +/- 0.13 cm, width 0.82 +/- 0.22 cm). Coagulum formation adherent to the electrode was exclusively observed following 18 of 42 nonirrigated RF current ablations. In conclusion, irrigated coiled ablation electrodes induce continuous linear lesions with a power output of 20-40 W. The risk of coagulum formation at the coiled electrode can be avoided by irrigation.

Animals↗

A randomized study on the effects of pacemaker programming to a lower output on projected pulse generator longevity.

The programmability of cardiac pacemakers enables the physician at follow-up to adjust the pacing pulse under consideration of the 100% safety margin with respect to the individual pacing threshold. The purpose of reducing the output is to prolong pacemaker longevity. The aims of this prospective, randomized trial were to compare the effects of nominal output versus a lower output on projected pacemaker longevity in single and dual chamber pacemakers. The secondary aim was to assess how many patients can be programmed to 2.5 V/0.4 ms instead of the nominal 3.5-V setting with > or = 100% safety margin. The patients received the same types of VVI or DDD pacemakers that were connected in the ventricle to the steroid-eluting, high impedance pacing lead. At the 3-month follow-up, patients with ventricular pacing thresholds < or = 0.15 ms at 2.5-V pulse amplitude were randomized to 3.5 V or 2.5 V amplitude at 0.4-ms pulse duration. Lead function and projected device longevity were assessed with the pacemaker's telemetry 6 and 12 months after implantation. Of patients implanted with a VVI pacemaker, at the 3-month follow-up, 3 patients had pacing thresholds > 0.15 ms at 2.5 V and 139 patients could be randomized. A reprogramming to a higher output was necessary in one patient. The mean percentage of ventricular pacing was about 40% throughout the study time. The programming to 2.5-V output resulted in an insignificant increase of device longevity from 117.9 +/- 18.7 months in the nominal group to 123.7 +/- 11.9 months at the 12-month follow-up (P = 0.16). Of patients implanted with a DDD pacemaker, 166 patients underwent randomization. The mean percentage of ventricular pacing was 85% in the ventricle and 35% in the atrium. The 2.5-V setting significantly prolonged pacemaker longevity from 98.1 +/- 21.3 to 112.0 +/- 13.6 months (P < 0.0001). In three (1%) patients a late increase of the pacing threshold was observed. Due to the low ventricular pacing thresholds, the 2.5-V/0.4-ms setting provided, 3 months after implantation, a > or = 100% safety margin in 99% of the patients. Programming to a lower output slightly increased projected pacemaker longevity compared to the nominal 3.5-V setting. Longevity increasedfor 5% in patients with single andfor 14% in dual chamber pulse generators.

Aged↗

Subthreshold stimulation at the focal origin of para-Hisian-located ectopic atrial tachycardia.

The focal origin of ectopic atrial tachycardia (EAT) is occasionally located in the superoparaseptal region adjacent to the bundle of HIS. Radiofrequency catheter ablation (RFCA) of EAT in this anatomic location implies the potential hazard of adverse impairment of the AV conduction. Therefore, careful precise mapping is mandatory. Subthreshold stimulation as defined as the delivery of noncaptured low energy pulses has been introduced as an additional mapping technique for slow pathway ablation in the setting of AV nodal reentrant tachycardia and other reentrant tachycardia. A patient with a right superoparaseptal EAT focus, in which subthreshold stimulation (STS) could determine the site of successful subsequent RFCA is described. During STS with EAT termination no AV conduction disturbances, junction-escape rhythms or atrial capture could be recorded. Thus STS may be used as an additional mapping tool to identify successful ablation sites in EAT.

Body Surface Potential Mapping↗

Psychiatric conditions in patients with recurrent unexplained syncope.

AIMS: The relationship between syncope and psychiatric disorders is little investigated. This study evaluated the prevalence of psychiatric diseases and prognostic outcome in patients with recurrent unexplained syncope. METHODS AND RESULTS: After an inconclusive standard diagnostic work-up for syncope, including head-up tilt testing, a psychiatric evaluation was offered to 50 consecutive patients with recurrent syncope. The evaluation was accepted by 26 patients (77% females, 36 +/- 16 years) and refused by 24 (63% females, 50 +/- 19 years). A psychiatric disorder was diagnosed in 21 (81%) patients: 12 had depression, four panic attacks, two general anxiety, and three a somatization disorder. Only five patients showed normal psychosocial function. Of the patients with psychiatric disorders four accepted psychiatric care, such as psychotherapy and/or pharmacotherapy; 17 patients refused treatment. During 6 months of follow-up no patient under psychiatric care had syncope, while all patients without psycho- or pharmacotherapy had recurrent syncopal events. In these patients the median of syncopal episodes was three in a 6 months interval before and after clinical assessment. Patients who refused both psychiatric evaluation and therapy continued to experience syncope as before. CONCLUSIONS: In patients with recurrent unexplained syncope psychiatric alteration is common. However, patients seldom accepted a psychiatric evaluation and treatment.

Adolescent↗

Oxidative stress increases endothelin-1 synthesis in human coronary artery smooth muscle cells.

Endothelins, nitric oxide, and oxygen-derived free radicals decisively regulate vascular tone. An imbalance in the biosynthesis of these substances in pathophysiologic conditions may trigger vasospasm and promote the development of atherosclerosis. Previous studies have shown that oxygen-derived free radicals can increase the synthesis of endothelin-1 in cultured endothelial cells. Interestingly, conditions of increased oxidative stress within smooth muscle cells as induced by angiotensin II infusion or hypercholesterolemia have been shown to be associated with increased autocrine synthesis of endothelin-1. Because endothelin-1 formed in smooth muscle cells can trigger hypersensitivity to vasoconstrictors, we tested whether oxidative stress per se may affect endothelin expression in vascular smooth muscle cells. Cultured human coronary artery smooth muscle cells were exposed to oxidative stress generated by the xanthine/xanthine oxidase reaction or by hydrogen peroxide. Preproendothelin-1 mRNA content was quantitated by means of quantitative polymerase chain reaction and endothelin-1 protein was measured by radioimmunoassay. Incubation with xanthine/xanthine oxidase significantly increased preproendothelin-1 mRNA synthesis, whereas GAPDH remained unchanged. Likewise, xanthine/xanthine oxidase also led to a dose-dependent increase of intracellular endothelin-1. The increase in ET-1 expression induced by xanthine/xanthine oxidase was significantly inhibited by superoxide dismutase but not by catalase. We conclude that oxygen-derived free radicals can stimulate the synthesis of endothelin-1 in endothelial and vascular smooth muscle cells by increasing preproendothelin-1 mRNA content and that this effect is mediated predominantly by superoxide anions. We therefore have identified a new mechanism in the interaction of oxidative stress and endothelin-1 expression in smooth muscle cells that may have important implications in diseases such as atherosclerosis and hypertension.

Cells, Cultured↗

Intravenous coronary angiography using synchrotron radiation: technical description and preliminary results.

BACKGROUND: Standard coronary angiography requires an arterial access and catheters; intravenous coronary angiography may image coronary arteries noninvasively and without catheters. The aim of this study was the assessment of the diagnostic accuracy of intravenous coronary angiography validated by selective coronary angiography. METHODS: Seventy outpatients (80% males, mean age 62 +/- 8 years) underwent both standard and intravenous coronary angiography after a previous coronary intervention. Intravenous coronary angiography was performed within 6 weeks before or after selective coronary angiography. Two different projections were used to obtain 6-8 sequences per patient. Images were taken after injection of the contrast agent into the brachial vein or into the superior vena cava. During image acquisition, patients were moved through the scanning beam on a special chair. Thereafter, images were evaluated and compared to selective coronary angiograms for the following criteria: no stenosis, subsignificant stenosis (< 70%), significant stenosis (> or = 70%), and occlusion. RESULTS: One hundred eighty-seven target vessels were analyzed. In 50 target vessels one or more stents had been implanted. Seventeen target vessels were not analyzable due to inadequate image quality. The sensitivity of intravenous coronary angiography for the detection of lesions was 80% and the specificity was 95%. The sensitivity for the detection of significant lesions in the left anterior descending coronary artery was 84% (specificity 93%), in the left circumflex coronary artery 67% (specificity 90%), in the right coronary artery 85% (specificity 97%), and in bypass grafts 85% (specificity 97%). No complications were observed. CONCLUSIONS: Intravenous coronary angiography is efficacious and safe and allows quantification of lesions of the coronary arteries and of bypass vessels. Further advances in image processing are needed to improve sensitivity especially in the left circumflex coronary artery.

Contrast Media↗

Radiofrequency catheter ablation of common-type atrial flutter guided by conventional versus electroanatomical mapping.

Radiofrequency catheter (RF) ablation aiming the complete conduction block of the cavotricuspid isthmus has become treatment of choice for common type atrial flutter. Different approaches to guide the ablation procedure are used. For the conventional approach multipolar catheters in the right atrium and in the coronary sinus are required to detect the induction of conduction block via the isthmus. RF current is applied starting at the ventricular site of the cavotricuspid isthmus under fluoroscopic control to recognise dislocation of the ablation catheter and to avoid potential complications. Three-dimensional electroanatomic (CARTO) activation mapping can be helpful to guide atrial flutter ablation. By the help of a magnetic sensor, embedded in the tip of the mapping catheter, a virtual frame of the cavotricuspid isthmus will be reconstructed. The middle region between the virtual septal and posterolateral border of the cavotricuspid isthmus will be targeted for the ablation lesion line. Both approaches have been shown to be associated with a high acute success rate and a low recurrence rate. The major difference is that the CARTO system leads to a substantial reduction of fluoroscopic time required for atrial flutter ablation. Thus, CARTO-guided ablation directed at the cavotricuspid isthmus represent a modern method for rapid and successful treatment of common-type atrial flutter with low radiation exposure. (Fig. 4, Ref. 16.)

Atrial Flutter↗

Inhibition of the sodium-hydrogen exchanger with cariporide to prevent myocardial infarction in high-risk ischemic situations. Main results of the GUARDIAN trial. Guard during ischemia against necrosis (GUARDIAN) Investigators.

BACKGROUND: The transmembrane sodium/hydrogen exchanger maintains myocardial cell pH integrity during myocardial ischemia but paradoxically may precipitate cell necrosis. The development of cariporide, a potent and specific inhibitor of the exchanger, prompted this investigation of the potential of the drug to prevent myocardial cell necrosis. METHODS AND RESULTS: A total of 11 590 patients with unstable angina or non-ST-elevation myocardial infarction (MI) or undergoing high-risk percutaneous or surgical revascularization were randomized to receive placebo or 1 of 3 doses of cariporide for the period of risk. The trial failed to document benefit of cariporide over placebo on the primary end point of death or MI assessed after 36 days. Doses of 20 and 80 mg every 8 hours had no effect, whereas a dose of 120 mg was associated with a 10% risk reduction (98% CI 5.5% to 23.4%, P=0.12). With this dose, benefit was limited to patients undergoing bypass surgery (risk reduction 25%, 95% CI 3.1% to 41.5%, P=0.03) and was maintained after 6 months. No effect was seen on mortality. The rate of Q-wave MI was reduced by 32% across all entry diagnostic groups (2.6% versus 1.8%, P=0.03), but the rate of non-Q-wave MI was reduced only in patients undergoing surgery (7.1% versus 3.8%, P=0.005). There were no increases in clinically serious adverse events. CONCLUSIONS: No significant benefit of cariporide could be demonstrated across a wide range of clinical situations of risk. The trial documented safety of the drug and suggested that a high degree of inhibition of the exchanger could prevent cell necrosis in settings of ischemia-reperfusion.

Aged↗

Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis.

BACKGROUND: Coronary in-stent restenosis might be triggered by contact allergy to nickel, chromate, or molybdenum ions released from stainless-steel stents. We investigated the association between allergic reactions to stent components and the occurrence of in-stent restenosis. METHODS: Patients with coronary stainless-steel stents who underwent angiography for suspected restenosis were consecutively included in this study. Quantitative coronary angiography for analysis of percentage diameter stenosis was done on 131 patients (mean age 62 years [SD 9]) with 171 stents 6.1 months (2.7) after stent implantation. All patients underwent epicutaneous patch tests (Finn chamber method) for nickel, chromate, molybdenum, manganese, and small 316L stainless-steel plates. Patch tests were assessed by independent dermatologists after 48 h, 72 h, and when necessary 96 h of contact with the potential allergen. FINDINGS: In-stent restenosis (> or =550% diameter stenosis) occurred in 89 patients. All ten patients with positive patch-test results had restenoses (p=0.03). Four male patients had positive reactions to molybdenum, and seven patients (four male, three female) had reactions to nickel. No patient with an allergic reaction to the standard test substances had a positive reaction to the stainless-steel plates. All patients with positive results had recurrent angina pectoris and needed target-vessel revascularisation. INTERPRETATION: Patients with allergic patch-test reactions to nickel and molybdenum had a higher frequency of in-stent restenoses than patients without hypersensitivity. Allergic reactions to nickel and molybdenum released from stents may be one of the triggering mechanisms for in-stent restenosis.

Adult↗

Vasodilator-stimulated phosphoprotein serine 239 phosphorylation as a sensitive monitor of defective nitric oxide/cGMP signaling and endothelial dysfunction.

Studies with cGMP-dependent protein kinase I (cGK-I)-deficient human cells and mice demonstrated that cGK-I ablation completely disrupts the NO/cGMP pathway in vascular tissue, which indicates a key role of this protein kinase as a mediator of the NO/cGMP action. Analysis of the vasodilator-stimulated phosphoprotein phosphorylated at serine 239 (P-VASP) is a useful tool to monitor cGK-I activation in platelets and cultured endothelial and smooth muscle cells. Therefore, we investigated whether endothelial dysfunction and/or vascular NO bioavailability is reflected by decreased vessel wall P-VASP and whether improvement of endothelial dysfunction restores this P-VASP. Incubation of aortic tissue from New Zealand White Rabbits with the NOS inhibitor N:(G)-nitro-Ld-arginine and endothelial removal strikingly reduced P-VASP. Oxidative stress induced by inhibition of CuZn superoxide dismutase increased superoxide and decreased P-VASP. Endothelial dysfunction in hyperlipidemic Watanabe rabbits (WHHL) was associated with increased vascular superoxide and with decreased P-VASP. Treatment of WHHL with AT(1) receptor blockade improved endothelial dysfunction, reduced vascular superoxide, increased vascular NO bioavailability, and increased P-VASP. Therefore, the level of vessel P-VASP closely follows changes in endothelial function and vascular oxidative stress. P-VASP is suggested to represent a novel biochemical marker for monitoring the NO-stimulated sGC/cGK-I pathway and endothelial integrity in vascular tissue.

Angiotensin Receptor Antagonists↗

Treatment of aortocoronary vein graft lesions with membrane-covered stents: A multicenter surveillance trial.

BACKGROUND: Stent implantation in lesions of degenerated aortocoronary vein grafts is associated with a high risk of periprocedural thrombus embolization and in-stent restenosis. METHODS AND RESULTS: In a multicenter study, we followed up 109 consecutive patients (mean age 66+/-8 years, 12% female) who received polytetrafluoroethylene (PTFE) membrane-covered stents for 125 de novo stenoses in vein grafts 11+/-5 years after bypass surgery. Stent deployment was successful in all but 1 patient; 1 patient suffered from subacute stent thrombosis. Six-month cardiac mortality was 7% (8 patients), 3 patients (3%) underwent repeat bypass surgery, and 9 patients (8%) required target-lesion PTCA. Repeat angiography revealed vessel occlusions in 9% and in-stent restenosis in 8% of patients by the end of follow-up. CONCLUSIONS: Membrane-covered stents appear to be a safe and efficient treatment strategy associated with a low incidence of restenosis and target-vessel revascularization. Compared with previous studies, the investigated device is not associated with an increase in mortality or late vessel occlusions.

Aged↗

Spin trapping of vascular nitric oxide using colloid Fe(II)-diethyldithiocarbamate.

Currently available EPR spin-trapping techniques are not sensitive enough for quantification of basal vascular nitric oxide (NO) production from isolated vessels. Here we demonstrate that this goal can be achieved by the use of colloid Fe(DETC)(2). Rabbit aortic or venous strips incubated with 250 microM colloid Fe(DETC)(2) exhibited a linear increase in tissue-associated NO-Fe(DETC)(2) EPR signal during 1 h. Removal of endothelium or addition of 3 mM N(G)-nitro-l-arginine methyl ester (L-NAME) inhibited the signal. The basal NO production was estimated as 5.9 +/- 0.5 and 8.3 +/- 2.1 pmol/min/cm(2) in thoracic aorta and vena cava, respectively. Adding sodium nitrite (10 microM) or xanthine/xanthine oxidase in the incubation medium did not modify the intensity of the basal NO-Fe(DETC)(2) EPR signal. Reducing agents were not required with this method and superoxide dismutase activity was unchanged by the Fe(DETC)(2) complex. We conclude that colloid Fe(DETC)(2) may be a useful tool for direct detection of low amounts of NO in vascular tissue.

Animals↗