Search PubMed⌕ Search

Biomedical subjects

T Marwick

Publications and source records attributed to T Marwick.

18 recordsLinked to original sources

Use of peak systolic strain as an index of regional left ventricular function: comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia.

OBJECTIVES: The goals of this study were to examine peak systolic strain as an index of regional function in an animal model of inotropic stress and ischemia, and to compare these results with peak systolic myocardial tissue Doppler velocity (MDV). BACKGROUND: Myocardial tissue Doppler velocity is an objective measure of regional left ventricular responses to inotropic stimulation and ischemia, but it is affected by tethering from adjacent segments and translational movement. Myocardial Doppler strain (epsilon, relative change in length) is a more local measure of contractility, which can now be derived noninvasively from MDV. METHODS: Eight dogs underwent graded dobutamine infusion followed by coronary occlusion. Epicardial 2-dimensional echocardiography and color MDV of the left ventricle were obtained and digitized from the short-axis view at baseline and with dobutamine doses of 2, 4, and 8 microg/kg per minute. These were repeated 0, 10, 20, 45, and 90 seconds after occlusion of the left anterior descending artery (LAD) (n = 3) or circumflex coronary artery (n = 5). Dobutamine was continued at 8 microg/kg per minute during coronary occlusion. The peak systolic radial MDV (cm/s) and systolic strain (epsilon(s), percent thickening) in the anterior and posterior walls were measured off-line at each stage. RESULTS: Dobutamine caused an increase in MDV (P =.0001) and epsilon(s) (P =.09) above baseline values. Coronary occlusion caused a reduction in wall motion; after 45 seconds, all nonperfused segments were hypokinetic. There was a corresponding decrease in MDV and epsilon(s), but this occurred earlier for epsilon(s), and the difference between ischemic and nonischemic segments was greater for epsilon(s) than for MDV (P <. 03). Nonischemic regions trended to an increase in epsilon(s) (compensatory hyperkinesis), whereas MDV trended downward, probably reflecting the global decrease in left ventricular function. CONCLUSION: Both MDV and epsilon(s) increase with dobutamine and decrease during ischemia. epsilon(s) appears to respond to local ischemia earlier than MDV, perhaps because it is a more local measure. Thus epsilon(s) may prove to be an accurate parameter for the clinical recognition of regional ischemia.

Animals↗

Developments in cardiovascular imaging.

The development of cardiovascular drugs appears to have gained further momentum over recent years. Many previous and ongoing studies have focused on outcomes with various interventions, but cardiac imaging techniques are developing to the extent that the physiological processes that they measure may be used as alternative study endpoints. Certainly, assessment of physiological parameters appears to be of considerable prognostic value. Use of imaging tests would have the advantage of shorter studies in smaller number of patients to demonstrate the efficacy of new cardiovascular therapies. A number of imaging techniques have been or are being used for this purpose, and will be the main focus of this review. Moreover, the prognostic power of these tests favors their use in optimizing clinical decision-making to obtain the most favorable outcome at the lowest cost.

Journal Article↗

Standardized guidelines for the interpretation of dobutamine echocardiography reduce interinstitutional variance in interpretation.

Subjective interpretation of dobutamine echocardiograms provides only moderate interinstitutional observer agreement if nonunified data acquisition and assessment criteria are applied. The present study was undertaken to evaluate parameters associated with low interinstitutional observer agreement in the interpretation of dobutamine echocardiograms and to analyze whether standardized interpretation criteria improve interinstitutional observer agreement. One hundred fifty dobutamine echocardiograms (dobutamine up to 40 microg/kg/min body weight and atropine up to 1 mg) were evaluated at 5 centers. Clinical, procedural, and echocardiographic parameters were included in the analysis of variables with significant impact on interinstitutional agreement. Standardized interpretative criteria were established, and 90 dobutamine echocardiograms were reanalyzed by 3 observers using a standardized image display. Multivariate analysis demonstrated low image quality (odds ratio [OR] 0.19, 95% confidence interval [CI] 0.08 to 0.45, p=0.0002), low severity of induced wall motion abnormality (OR 0.17, 95% CI 0.07 to 0.40, p <0.0001), and a low peak rate-pressure product (OR 0.93, 95% CI 0.43 to 2.27, p=0.0382) to result in a low interinstitutional agreement. Standardization of image display in cine loop format and of dobutamine stress echo interpretation criteria resulted in improvement in test result categorization as normal or abnormal, with a kappa value of 0.50, compared with 0.39 using the original subjective interpretation. In conclusion, image quality, the severity of induced wall motion abnormalities, and the obtained rate-pressure product have a significant impact on the interpretation homogeneity of dobutamine echocardiograms. Standardization of image display in cine loop format and of reading criteria results in improved interinstitutional agreement in interpretation of stress echocardiograms.

Adult↗

Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms.

OBJECTIVES: This study sought to determine the degree of interinstitutional agreement in the interpretation of dobutamine stress echocardiograms. BACKGROUND: Dobutamine stress echocardiography involves subjective interpretation. Consistent methods for acquisition and interpretation are of critical importance for obtaining high interobserver agreement and for facilitating communication of test results. METHODS: Five experienced centers were each asked to submit 30 dobutamine stress echocardiograms (dobutamine up to 40 micrograms/kg body weight per min and atropine up to 1 mg) obtained in patients undergoing coronary angiography. Thus, a total of 150 dobutamine stress echocardiograms were interpreted by each center without knowledge of any other patient data. Left ventricular wall motion was assessed using a 16-segment model but was otherwise not standardized. No patient was excluded because of poor image quality or inadequate stress level. Echocardiographic image quality was assessed using a five-point scale. RESULTS: Angiographically significant coronary artery disease (> or = 50% diameter stenosis) was present in 95 patients (63%). By a majority decision (three or more centers), the sensitivity, specificity and accuracy of dobutamine echocardiography were 76%, 87% and 80%, respectively. Abnormal or normal results of stress echocardiography were agreed on by four or all five of the centers in 73% of patients (mean kappa value 0.37, fair agreement only). Agreement on the left anterior descending artery territory (78%) was similar to that for the combined right coronary artery/left circumflex artery territory (74%), and for specific segments the agreement ranged from 84% to 97% and was highest for the basal anterior segment and lowest for the basal inferior segment. Agreement was higher in patients with no (82%) or three-vessel coronary artery disease (100%) and lower in patients with one- or two-vessel disease (61% and 68%, respectively). Agreement on positivity or negativity of stress test results was 100% for patients with the highest image quality but only 43% for those with the lowest image quality (p = 0.003). CONCLUSIONS: The current heterogeneity in data acquisition and assessment criteria among different centers results in low interinstitutional agreement in interpretation of stress echocardiograms. Agreement is higher in patients with no or advanced coronary artery disease and substantially lower in those with limited echocardiographic image quality. To increase interinstitutional agreement, better standardization of image acquisition and reading criteria of stress echocardiography is recommended.

Cardiotonic Agents↗

Head-to-head comparison of exercise-redistribution-reinjection thallium single-photon emission computed tomography and low dose dobutamine echocardiography for prediction of reversibility of chronic left ventricular ischemic dysfunction.

OBJECTIVES: We sought to directly compare the diagnostic value of exercise-redistribution-reinjection thallium single-photon emission computed tomography (SPECT) and low dose dobutamine echocardiography for prediction of contractile recovery after revascularization. BACKGROUND: Both thallium SPECT and dobutamine echocardiography have been proposed to predict the reversibility of left ventricular dysfunction after revascularization. Although both techniques permit differentiation of viable from nonviable myocardium, few studies have directly compared their accuracy in the same patients. METHODS: Seventy-three consecutive patients (mean [+/- SD] age 59 +/- 9 years) with coronary disease and regional left ventricular dysfunction underwent exercise-redistribution-reinjection thallium SPECT and dobutamine echocardiography before revascularization. Recovery of function was evaluated with echocardiography 5.5 +/- 2.5 months after revascularization. For analysis, the left ventricle was divided into 16 segments, in which percent thallium uptake was quantitated using circumferential profiles, and regional wall motion was graded semiquantitatively (normal = 1; akinetic = 3). RESULTS: The diagnostic performance of the two tests was investigated both for individual patients and for individual segments. Individual patient analysis showed that left ventricular ejection fraction improved > 5% after revascularization in 43 patients, whereas 30 showed no change. Receiver operating characteristic curves were used to select optimal criteria for prediction of functional recovery after revascularization. According to a mean thallium uptake > 54% at reinjection, SPECT had a sensitivity of 72%, a specificity of 73% and an overall accuracy of 73%. Similarly, according to an improvement in wall motion score > 3.5 grades during doubutamine echocardiography, echocardiography had a sensitivity of 88%, a specificity of 77% and an overall accuracy of 84% (p = NS vs. thallium). Segmental analysis showed that SPECT and dobutamine echocardiography had similar sensitivity (77% and 75%, respectively), but SPECT had lower specificity (56% vs. 86%, p < 0.01). CONCLUSIONS: Quantitative exercise-redistribution-reinjection thallium SPECT and dobutamine echocardiography have comparable accuracy for prediction of reversibility of global left ventricular dysfunction after revascularization. However, dobutamine echocardiography has greater specificity than thallium imaging for prediction of functional recovery on a segmental basis.

Cardiac Catheterization↗

Doppler echocardiographic detection of left ventricular diastolic dysfunction in patients with pulmonary sarcoidosis.

STUDY OBJECTIVE: To determine the prevalence of left ventricular diastolic dysfunction in patients with biopsy specimen-proved pulmonary sarcoidosis without clinical evidence of cardiac disease. DESIGN: A cross-sectional study. SETTING: A large tertiary care university teaching hospital. PATIENTS AND CONTROL SUBJECTS: Fifty consecutive subjects had biopsy specimen-proved pulmonary sarcoidosis without suspected cardiac involvement. Those with other conditions known to affect diastolic function were excluded. The control group comprised 30 healthy hospital workers. INTERVENTIONS: Clinical examination, 12-lead ECG, and combined echocardiographic/phonocardiographic examination. MEASUREMENTS: Indexes of left ventricular diastolic function, including isovolumic relaxation time, peak velocity of early (E) and late (A) ventricular filling, deceleration rate of early diastolic flow, and the sum of the time velocity integrals of E and A were obtained in each patient and control subject. Systolic function was determined using a modification of Simpson's rule. RESULTS: Diastolic dysfunction was present in 7 (14%) patients, 6 of whom had normal systolic function and normal two-dimensional echocardiographic examination. Those with diastolic dysfunction had a longer duration of illness (15 +/- 7 vs 6 +/- 5 years; p = 0.0004), were significantly older (52 +/- 11 vs 38 +/- 9 years; p = 0.0009), and had higher systolic BP (130 +/- 13 vs 117 +/- 12 mm Hg; p = 0.01) than the sarcoid patients with normal diastolic function. CONCLUSIONS: These results demonstrate a significant prevalence of left ventricular diastolic dysfunction in patients with pulmonary sarcoidosis. The cause of this abnormality may be a subclinical sarcoid cardiomyopathy.

Adult↗

Optimal use of dobutamine stress for the detection and evaluation of coronary artery disease: combination with echocardiography or scintigraphy, or both?

OBJECTIVES: This study was conducted to examine the efficacy of dobutamine stress two-dimensional echocardiography and perfusion scintigraphy for the detection of coronary artery disease in routine practice, to establish the causes of erroneous results and to derive appropriate criteria for the selection of either or both tests. BACKGROUND: Dobutamine stress combined with echocardiography or perfusion scintigraphy may be used to detect coronary artery disease. Although both imaging approaches have demonstrated similar levels of accuracy, it is not known whether there may be particular indications for the use of one or the other technique or a rationale for their combination. METHODS: Two hundred seventeen patients without previous infarction were studied prospectively with dobutamine stress echocardiography and technetium-99m methoxy isobutyl nitrile (sestamibi) single-photon emission computed tomography at the time of diagnostic coronary angiography. The presence of coronary stenoses of > or = 50% diameter was compared with the presence of rest or stress-induced abnormalities of perfusion and regional function. The extent of these abnormalities was correlated with an equivalent score of extent of angiographic disease. RESULTS: Significant coronary artery disease was found in 142 patients; 102 (72%) were identified by dobutamine echocardiography and 108 (76%, p = NS) by perfusion imaging. In 75 patients without significant disease, the specificity of dobutamine echocardiography was 83% compared with 67% for scintigraphy (p = 0.05). Echocardiographic sensitivity was lower in patients unable to complete the test because of side effects (n = 64) than in the remainder (59% vs. 77%, p = 0.02); this influence was less apparent with scintigraphy (71% vs. 78%, p = NS). Selective use of scintigraphy in the 31 patients with a negative submaximal stress echocardiogram led to a sensitivity of 80% for this combination. Patients with left ventricular hypertrophy accounted for most of the difference in specificity between echocardiography and scintigraphy (94% vs. 59%, p = 0.02). Their respective accuracies were 76% and 73%. CONCLUSIONS: Dobutamine stress echocardiography and perfusion scintigraphy have equivalent accuracy. In patients with left ventricular hypertrophy, echocardiography appears to be the test of choice. Selective use of sestamibi scintigraphy in patients with a negative submaximal echocardiogram enhances the accuracy of stress echocardiography alone.

Aged↗

Diagnosis of coronary artery disease in elderly patients: safety and efficacy of dobutamine echocardiography.

Coronary artery disease may be difficult to diagnose in the elderly because its clinical symptomatology is frequently atypical and because the performance of submaximal tests makes exercise stress testing sometimes unreliable. Dobutamine stress testing may be a useful alternative in such patients. This study compared the safety and accuracy of dobutamine stress echocardiography in 73 'young' (< 60 years old) and 63 'old' (> or = 60 years old) patients without previous myocardial infarction undergoing diagnostic coronary angiography. The sensitivity in young patients (79%, (67-91, 95% CI)) was similar to that in old patients (80% (69-91, 95% CI)). Similar levels of specificity (88% (75-101, 95% CI) vs 75% (54-96, 95% CI)) were found in the two groups. Both groups showed a trend to a higher sensitivity for multi-vessel disease than for single-vessel disease. No major side effect occurred during the entire study and peak dose (40 micrograms.kg-1.min-1) was attained with similar frequency in both groups (56% vs 49%). Minor side effects occurred equally in 'young' and 'old' patients and never persisted more than a few minutes after ending the first infusion of dobutamine. Dobutamine echocardiography appears to be safe and accurate for the detection of coronary artery disease regardless of age.

Adult↗

Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography.

BACKGROUND: The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion are similar. The purpose of this study was to establish the optimal stress for each imaging technique by comparing the results of digitized 2DE and 99mTc-methoxyisobutyl isonitrile (MIBI) SPECT using both dobutamine and adenosine stresses in the same patients and conditions. METHODS AND RESULTS: Ninety-seven consecutive patients without evidence of previous infarction undergoing coronary angiography for clinical indications were studied prospectively. Dobutamine was infused during clinical, ECG, and echocardiographic monitoring in dose increments from 5 to 40 micrograms.kg-1.min-1. Adenosine was infused under the same conditions in doses of 0.10, 0.14, and 0.18 mg.kg-1.min-1. For each protocol, the end points were achievement of peak dose, development of severe ischemia, or intolerable side effects. At peak stress, 20 mCi of MIBI was injected, and SPECT imaging was performed 2 hours later; abnormal poststress images were compared with resting SPECT: Digitized 2DE images were compared qualitatively before, during, and after stress in a cine-loop display. Significant coronary disease (n = 59 patients) was defined by the quantification of > 50% stenosis in a major epicardial vessel. The sensitivity of adenosine 2DE was 58%, less than those of adenosine MIBI (86%, p = 0.001), dobutamine 2DE (85%, p = 0.001), and dobutamine MIBI (80%, p = 0.01). Their respective specificities were 87%, 71%, 82%, and 74% (p = NS). The accuracy of adenosine 2DE was 69%, compared with 80% for adenosine MIBI (p < 0.001), 84% for dobutamine 2DE (p = 0.001), and 77% for dobutamine MIBI (p = 0.005); the latter three did not differ significantly in either sensitivity or accuracy. CONCLUSIONS: This prospective, direct comparison of alternative pharmacological stresses in patients without myocardial infarction shows vasodilator stress scintigraphy and dobutamine stress echocardiography and scintigraphy to share equivalent levels of sensitivity. All three are significantly more sensitive than adenosine stress echocardiography. Dobutamine stress may be used for wall motion or perfusion imaging, but adenosine stress is best combined with perfusion scintigraphy.

Adenosine↗

Evaluation of mitral leaflet motion by echocardiography and jet direction by Doppler color flow mapping to determine the mechanisms of mitral regurgitation.

OBJECTIVES: This study was designed to assess the accuracy of two-dimensional and Doppler echocardiography in determining the mechanism of mitral regurgitation, as compared with direct inspection of the valve at operation. BACKGROUND: Valve repair for mitral regurgitation offers substantial advantages over valve replacement, but it is technically more demanding and requires understanding of the mechanism of dysfunction. METHODS: We studied 286 patients undergoing mitral valve repair. Intraoperative two-dimensional echocardiography was used to classify mitral leaflet motion as excessive, normal or restricted. Doppler color flow mapping was used to evaluate the direction and origin of the mitral regurgitant jet. Two-dimensional and Doppler echocardiography were compared with intraoperative surgical determination of the mechanism of dysfunction, which also classified leaflet motion as excessive, normal or restricted. RESULTS: Two-dimensional and Doppler echocardiography accurately diagnosed the mechanism of mitral regurgitation in 123 (93%) of 132 patients with posterior leaflet prolapse or flail, 30 (94%) of 32 patients with anterior leaflet prolapse or flail, 11 (44%) of 25 patients with bileaflet prolapse or flail, 6 (75%) of 8 patients with papillary muscle elongation or rupture, 31 (91%) of 34 patients with restricted leaflet motion or rheumatic thickening, 21 (72%) of 29 patients with ventricular-annular dilation and 8 (62%) of 13 patients with a leaflet perforation or cleft. Of 13 patients with two mechanisms of dysfunction by surgical inspection, two-dimensional and Doppler echocardiography correctly diagnosed one of the two mechanisms in 12 patients (92%), and both mechanisms in 5 patients (38%). Overall, echocardiographic determination of leaflet motion and Doppler determination of jet direction accurately diagnosed the mechanism of dysfunction in 242 (85%) of 286 patients. CONCLUSIONS: Echocardiography before mitral valvuloplasty provides a dynamic appraisal of the mechanism of dysfunction, enabling the surgeon to systematically understand the dysfunction and successfully apply the correct procedures to eliminate mitral regurgitation without valve replacement.

Blood Flow Velocity↗

Protection against ischemia during prolonged balloon inflation by distal coronary perfusion with use of an autoperfusion catheter or Fluosol.

OBJECTIVES: The purpose of this report was to study the protective effects of passive and active distal coronary perfusion during prolonged balloon inflation. BACKGROUND: Prolonged balloon inflation has been proposed to improve immediate and long-term results of percutaneous transluminal coronary angioplasty, but it requires protection against myocardial ischemia. METHODS: A 30-min balloon occlusion of the left anterior descending artery was performed in three groups of closed chest anesthetized dogs: 1) control (no distal coronary perfusion, n = 13), 2) passive distal coronary perfusion (autoperfusion catheter, n = 10), and 3) active distal coronary perfusion (infusion of the perfluorochemical Fluosol at 30 ml/min, n = 11). RESULTS: At 10 min of balloon inflation, echocardiographic wall motion indexes (scored from 1 [normal] to 5 [dyskinesia]) in the autoperfusion catheter and Fluosol groups (2.4 +/- 1.2 and 2.0 +/- 0.9, respectively) were significantly better than in the control group (3.6 +/- 0.4, p = 0.001), but at 25 min this improvement in wall motion had attenuated and became statistically insignificant when compared with values in the control group. Left ventricular end-diastolic pressure at peak inflation in the Fluosol group (19.5 +/- 5.5 mm Hg) was higher than in the control (7.6 +/- 3.6) and autoperfusion catheter (5.3 +/- 1.4, p < or = 0.01) groups. Pathologic evidence of infarction by tetrazolium staining was seen in three control dogs and in none of the other groups (p = 0.07). Ventricular tachycardia and fibrillation were less frequent in the autoperfusion catheter group (p = 0.02). Three deaths were observed in the control dogs, two in the Fluosol group and none in the dogs with an autoperfusion catheter (p = NS). CONCLUSIONS: Passive (the autoperfusion balloon catheter) and active (Fluosol) distal coronary perfusion methods are comparable and better than no perfusion in protecting the myocardium against ischemia produced by prolonged coronary balloon inflation in an experimental canine model. This protection is transient, attenuating after 10 to 25 min, and partial because there was no significant difference in the incidence of myocardial infarction and death among groups, although the latter observations may be related to small sample size.

Angioplasty, Balloon, Coronary↗

Percutaneous balloon valvotomy for the treatment of isolated tricuspid stenosis.

A 46-year-old woman with isolated tricuspid stenosis complained of increasing fatigue and dyspnea on exertion. Exercise Doppler echocardiography reproduced her symptoms and revealed a marked increase in trans-tricuspid gradient. Successful percutaneous balloon tricuspid valvotomy was performed, with resolution of her symptoms.

Catheterization↗

Use of digital subtraction fluorography in screening for coronary artery disease in patients with chronic renal failure.

The diagnosis of coronary artery disease remains a major problem in patients with end-stage renal disease. Screening with conventional noninvasive techniques is limited by the poor exercise capacity of these patients. This study evaluated the accuracy of digital subtraction fluorography in detecting coronary calcification as a noninvasive, nonexercise screening test for coronary artery disease. Eighty-six patients under evaluation for renal transplantation and considered at increased risk of coronary artery disease were studied by coronary arteriography and digital subtraction fluorography for coronary calcification. Significant coronary disease (greater than or equal to 50% obstruction in at least one vessel) was present in 36 (42%) patients. The detection of coronary calcification by digital subtraction fluorography had a sensitivity of 78% and a specificity of 66%. The probability of disease being present in the absence of coronary calcification in this group was 18%. The detection of coronary calcification by digital subtraction fluorography appears to be a satisfactory and inexpensive screening test in this setting.

Calcinosis↗

Angiodysplasia of the upper gastrointestinal tract. Clinical spectrum in 41 cases.

Over a 3-year period, arteriovenous malformations (angiodysplasia) were identified at upper gastrointestinal endoscopy in 41 patients. The lesions were multiple in one-third of patients and were predominantly situated in the proximal stomach. We considered angiodysplasia to be the cause of upper gastrointestinal bleeding in 11 (27%) patients and of anemia in nine (22%) patients. In these two groups other mucosal lesions were not seen at upper gastrointestinal endoscopy and there had been prior undiagnosed episodes of overt or occult bleeding in almost half. In 21 (51%) patients the lesions were judged to be incidental findings. Other medical conditions noted were the presence of an aortic systolic murmur (24%) and renal impairment (12%). Only three patients had mucocutaneous telangiectasia (two had Osler-Rendu-Weber syndrome, and one had scleroderma with CRST syndrome). Specific treatment in 14 symptomatic patients included endoscopic electrocoagulation or injection sclerotherapy. In eight patients with adequate post-treatment surveillance, endoscopy demonstrated obliteration of the vascular lesions.

Adult↗

Cost analysis of diagnostic testing for coronary artery disease in women with stable chest pain. Economics of Noninvasive Diagnosis (END) Study Group.

BACKGROUND: Seven clinical sites compiled data from 4638 women who were referred directly to coronary angiography (catheterization-first strategy; n = 3375) or who underwent stress myocardial perfusion imaging (MPI) first (n = 1263) followed by coronary angiography if at least one reversible myocardial perfusion abnormality was detected. The study examines the cost minimization potential of these available invasive and noninvasive diagnostic strategies in women with chest pain. METHODS AND RESULTS: Women in both groups were subclassified by the core laboratory as being at low (<0.15), intermediate (0.15 to 0.60), or high (>0.60) pretest likelihood for coronary artery disease (CAD). Among the catheterization-first patients, at least one coronary stenosis >70% was present in 13% of low likelihood patients, 29% of intermediate likelihood patients, and 52% of patients with high CAD likelihood. Perfusion abnormality rates in the MPI-first group were 23% in low likelihood patients, 27% in intermediate likelihood patients, and 34% in high CAD likelihood patients. Of the MPI-first subset, 50%, 55%, and 76%, respectively, underwent catheterization in at least one coronary stenosis >70%. Cardiac death rates ranged from 0.5% to 2.2% in patients with CAD and did not differ from the 2 testing strategies (P = not significant). The composite cost per patient of diagnostic testing plus follow-up medical care over a period of 2.5 +/- 1.5 years (calculated for both strategies from inflation-corrected Medicare charges, adjusted for institutional cost-charge ratios) ranged from $2490 for patients with low likelihood to $3687 for patients with high likelihood with the catheterization-first strategy and from $1587 to $2585 for patients undergoing MPI first (P < .01 between risk subsets and strategies). CONCLUSIONS: In women referred for diagnostic evaluation of stable chest pain, MPI followed by selective coronary angiography in patients with at least 1 perfusion abnormality minimizes the near-term composite cost per patient compared with a direct catheterization-first strategy, regardless of pretest CAD likelihood.

Aged↗

Hemopericardium and cardiac tamponade associated with warfarin therapy.

We report the case of a 67-year-old man with vertebral-basilar arterial insufficiency who had been receiving warfarin therapy for approximately 2 years. The patient presented with a 3-week history of weight gain, abdominal distension, and mild exertional dyspnea. Transthoracic echocardiography confirmed the presence of a large circumferential pericardial effusion with diastolic collapse of the right atrium, and a pulsed-wave Doppler echocardiographic study of mitral and tricuspid diastolic flow showed respiratory variation consistent with cardiac tamponade. The patient's prothrombin time was 30 seconds, which decreased to 17 seconds after treatment with intravenous fresh-frozen plasma and vitamin K. He underwent drainage of 2 L of bloody pericardial fluid over 12 hours by pericardiocentesis. Extensive further studies failed to demonstrate known causes or correlates of pericardial effusion. The patient was discharged and continued to do well without warfarin therapy.

Aged↗

Current status of stress echocardiography in the diagnosis of coronary artery disease.

Stress echocardiography is a cost-effective and reliable diagnostic test for patients with suspected coronary artery disease. Stress echocardiography should be used in preference to exercise electrocardiography as the primary test in patients with uninterpretable ST segments. It is attractive for use as the primary test in patients with coexisting valvular disease. It probably is the optimal test for women. Stress echocardiography should be used as a secondary test when the result of exercise electrocardiography is inconsistent with the clinical status. In patients requiring nonexercise stress testing, an imaging test is mandatory. The ability of stress echocardiography to identify the location and extent of myocardial ischemia makes it appropriate in situations where decisions regarding revascularization will be made on these grounds. The overall accuracy of stress echocardiography and perfusion scintigraphy is comparable in expert hands. but one must always consider the expertise of the operator and the quality of each test in the environment in which it is performed.

Coronary Disease↗