The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

Although the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extracorporeal circuit have not been fully investigated regarding the quality of the pulsatility. In addition, most of these results have been gathered from adult patients, not from neonates and infants. We have designed and tested a neonate-infant pulsatile CPB system using 2 different types of 10 Fr aortic cannulas and membrane oxygenators in 3 kg piglets to evaluate the effects of these components on the pulsatile waveform produced by the system. In terms of the methods, Group 1 (Capiox 308 hollow-fiber membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 2]) was subjected to a 2 h period of normothermic pulsatile CPB with a pump flow rate of 150 ml/kg/min. Data were obtained at 5, 30, 60, 90, and 120 min of CPB. In Group 2 (Capiox 308 hollow-fiber membrane oxygenator and Elecath aortic cannula with a very long 10 Fr tip [n = 7]) and Group 3 (cobe VPCML Plus flat sheet membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 7]), the subjects' nasopharyngeal temperatures were reduced to 18 degrees C followed by 1 h of deep hypothermic circulatory arrest (DHCA) and then 40 min rewarming. Data were obtained during normothermic CPB in the pre- and post-DHCA periods. The criteria of pulsatility evaluations were based upon pulse pressure (between 30 and 40 mm Hg), aortic dp/dt (greater than 1000 mm Hg/s), and ejection time (less than 250 ms). The results showed that Group 1 produced flow which was significantly more pulsatile than that of the other 2 groups. Although the same oxygenator was used for Group 2, the quality of the pulsatile flow decreased when using a different aortic cannula. Group 3 did not meet any of the criteria for physiologic pulsatility. In conclusion these data suggest that in addition to a pulsatile pump, the aortic cannula and the membrane oxygenator must be chosen carefully to achieve physiologic pulsatile flow during CPB.

Animals

Testing neonate-infant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitro.

Neurologic complications are already well documented after cardiopulmonary bypass (CPB) procedures in neonates and infants. Physiologic pulsatile flow CPB systems may be the alternative to the currently used steady-flow CPB circuits. In addition to the pulsatile pump, a membrane oxygenator should be chosen carefully, because only a few membrane oxygenators are suitable for physiologic pulsatile flow. We have tested four different types of neonate-infant membrane oxygenators for physiologic pulsatility with The University of Texas neonate-infant pulsatile CPB system in vitro. Evaluation criteria were based on mean ejection time, extracorporeal circuit (ECC) pressure, and upstroke of dp/dt. The results suggested that the Capiox 308 hollow-fibre membrane oxygenator produced the best physiologic pulsatile waveform according to the ejection time, ECC pressure, and the upstroke of dp/dt. The Minimax Plus and Masterflo Infant hollow-fibre membrane oxygenators also produced adequate pulsatile flow. Only the Variable Prime Cobe Membrane Lung (VPCML) Plus flat-sheet membrane oxygenator failed to reach the criteria for physiologic pulsatility. Depending on the oxygenator used, the lowest priming volume of the infant CPB circuit was 415 ml and the highest 520 ml.

Brain Diseases

Regional blood flow during pulsatile cardiopulmonary bypass and after circulatory arrest in an infant model.

BACKGROUND: Pulsatile perfusion systems have been proposed as a means of improving end-organ perfusion during and after cardiopulmonary bypass. Few attempts have been made to study this issue in an infant model. METHODS: Neonatal piglets were subjected to nonpulsatile (n = 6) or pulsatile (n = 7) cardiopulmonary bypass and 60 minutes of circulatory arrest. Cerebral, renal, and myocardial blood flow measurements were obtained at baseline, on bypass before and after circulatory arrest, and after bypass. RESULTS: Cerebral blood flow did not differ between groups at any time and was diminished equally in both groups after circulatory arrest. Renal blood flow was diminished in both groups during bypass but was significantly better in the pulsatile group than in the nonpulsatile group prior to, but not after, circulatory arrest. Myocardial blood flow was maintained at or above baseline in the pulsatile group throughout the study, but in the nonpulsatile group, it was significantly lower than baseline during CPB prior to circulatory arrest and lower compared with baseline and with the pulsatile group 60 minutes after CPB. CONCLUSIONS: Pulsatile bypass does not improve recovery of cerebral blood flow after circulatory arrest, may improve renal perfusion during bypass but does not improve its recovery after ischemia, and may have beneficial effects on myocardial blood flow during bypass and after ischemia compared with nonpulsatile bypass in this infant model.

Animals

Enhancement of brain p0(2) during cardiopulmonary bypass using a hyperosmolar oxygen carrying solution.

During the past decade a new syndrome has been recognized: cerebral hypoxia secondary to cardiopulmonary bypass, resulting in impairment of cognitive memory. The incidence of the syndrome appears to be no less that 30% in patients over 65 years of age undergoing cardiac surgery. There are several factors contributing to hypoxia produced by cardiopulmonary bypass. One of these factors is crystalloid pump prime and replacement solutions devoid of (1) oxygen carrying capacity and (2) devoid of protein and its colloid osmotic pressure. This shortcoming of cardiopulmonary crystalloid solutions is partially responsible for two of the three major pathologic effects of cardiopulmonary bypass: (1) hypoxia (2) interstitial fluid accumulation (anasarca, water-logging, edema). This report describes an oxygen carrying hyperosmolar solution which enhances brain p0(2) and diminishes interstitial fluid accumulation. This blood substitute consists of perfluorcarbons and saccharides, but could consist of a hemoglobin variant plus hyperosmolar ingredients other than saccharides. The advantage of a perfluorochemical is its ability to access small channels and to be centrifuged off the patient post-operatively with a cell saver. The advantage of saccharides is that they can be metabolized by the patient for energy, and they produce a moderate diuresis coming off bypass.

Animals

Design of a physiologic pulsatile flow cardiopulmonary bypass system for neonates and infants.

Cardiopulmonary bypass surgical techniques that allow a surgeon to operate on the infant's heart use an extracorporeal circuit consisting of a pump, oxygenator, arterial and venous reservoirs, cannulae, an arterial filter, and tubing. The extracorporeal technique currently used in infants and neonates is sometimes associated with neurologic damage. We are developing a modified cardiopulmonary bypass system for neonates that has been tested in vitro and in one animal in vivo. Unlike other extracorporeal circuits which use steady flow, this system utilizes pulsatile flow, a low prime volume (500 ml) and a closed circuit. During in vitro experiments, the pseudo patient's mean arterial pressure was kept constant at 40 mmHg and the extracorporeal circuit pressure did not exceed a mean pressure of 200 mmHg. In our single in vivo experiment, the primary objective was to determine whether physiologic pulsatility with a 10 F (3.3 mm) aortic cannula could be achieved. The results suggest that this is possible.

Animals

Hemodialysis: evidence of enhanced molecular clearance and ultrafiltration volume by using pulsatile flow.

We describe several in vitro experiments showing evidence that pulsatile flow hemodialysis enhances ultrafiltration volume and molecular clearance as compared with steady flow hemodialysis. A new pulsatile pump and a conventional roller pump were compared using different hollow fiber dialyzers and a simulated blood solution containing urea, aspartame and vitamin B-12 at different flow rates and configurations. Ultrafiltration volume and concentration of urea, aspartame and B-12 were measured and molecular clearance (K) calculated. Ultrafiltration volume markedly increased with pulsatile flow. After 10 min K for urea with pulsatile flow was higher in all experiments even when ultrafiltration was prevented. Clearance of aspartame and B-12 also increased with pulsatile flow. We propose three mechanisms by which pulsatile flow is more efficient than steady flow hemodialysis: greater fluid energy, avoidance of molecular channeling and avoidance of membrane layering. We hypothesize that using pulsatile flow in hemodialysis can significantly shorten the duration of dialysis sessions for most of the patients, and consequently reduce the duration of the procedure and its cost.

Aspartame

Tubing spallation in extracorporeal circuits. An in vitro study using an electronic particle counter.

The roller pump is the most common pumping device used in extracorporeal circulation (ECC). The interaction between the roller and tubing causes tubing spallation. Spallation has been associated with complications in ECC. Previous spallation studies present mixed results, including a decrease in the number of circulating particles. The objective of this work is to perform an in vitro study of tubing spallation which elucidates the causes of the particle sequestration, and the effect of tubing material, blood flow rate and duration of the procedure upon spallation. A sampling method minimizing background counts was devised. Silicone and PVC tubing were tested under normal and tight occlusion pressure at typical cardiopulmonary bypass and hemodialysis flow rates, for circulating times up to 4 h. Occlusion pressure and flow rate highly influenced the amount of spallation produced. Particle sequestration was noted and aggregation of the plastic particles was demonstrated. We conclude that, at least in vitro, aggregation causes the decrease in the particle counts and the misleading results obtained in most spallation studies using a Coulter counter.

Biocompatible Materials

Comparison of a steady flow pump to a preload responsive pulsatile pump in left atrial-to-aorta bypass in canines.

A unique preload responsive pulsatile pump was compared to a centrifugal pump in total cardiac support in 25-kg canines (n = 6, each group) in the left atrial-to-aorta mode during 5 h of ventricular fibrillation. With steady flow, there was immediate drop in output from 2.1 +/- 1.0 L/min to 1.4 +/- 0.3 L/min, followed by further reduction to 0.9 +/- 0.2 L/min during 5 h of ventricular fibrillation. With a pulsatile pump, there was no significant reduction from control of 2.4 +/- 0.6 L/min and no decline during 5 h of ventricular fibrillation. With steady flow, systemic vascular resistance (SVR) rose significantly from 1,762 dyne-s-cm-5 immediately on pump to 3,013 dyne-s-cm-5 at 5 h. With physiologic pulsatile flow, significant elevation of SVR did not occur. When stressed, due to diminished left atrial return, the centrifugal pump displayed line chatter and streaks of microbubbles, whereas the pulsatile pump did not. Crystalloid volume replacement with the centrifugal pump was 6.5 +/- 1.9 L, and with the preload responsive pulsatile pump, 5.6 +/- 1.3 L. It is concluded that in the left atrial-to-aorta mode during 5 h of ventricular fibrillation and with comparable volume replacement, total cardiac support of canines is associated with lower SVR with physiologic pulsatile flow and is not accompanied by line chatter and cavitation with this preload responsive pump.

Animals

Preload-responsive, pulsatile-flow, externally valved pump: cardiopulmonary bypass.

Currently two pumps are used for cardiopulmonary bypass, the roller pump and the centrifugal or vortex pump. Both are steady-flow pumps. The procedure of cardiopulmonary bypass possesses a finite morbidity and mortality. The degree to which steady flow is responsible for this morbidity and mortality remains to be clarified, but investigators have established the fact that a physiologic degree of pulsatile flow must be achieved before its beneficial results, such as normal systemic resistance and absence of lactate production, can be demonstrated. Availability of a satisfactory pulsatile pump for cardiopulmonary bypass has been a problem in the past but the pump presented here may satisfy this need. It produces physiologic pulsatility with rate dependent ejection time equal to or less than that of humans (413 microseconds minus 1.7 times heart rate), and it is preload-responsive, varying its pumping rate and output with filling pressure. The pump is externally valved to minimize hemolysis, which has been demonstrated in two laboratory studies to be significantly less than with the roller pump. It produces pulsatile flow through membrane oxygenators. The pump is thought to have potential for several clinical applications in addition to (1) pulsatile-flow cardiopulmonary bypass, including (2) left, right, or combined transthoracic QRS synchronized ventricular assist, (3) femoral vein to femoral artery QRS synchronized left ventricular assist, (4) adult or infant ECMO, (5) pulsatile flow hemodialysis. In the latter, spallation and embolization of hemodialysis tubing particles should not be a problem as has proved to be the case with the present hemodialysis pump.

Cardiopulmonary Bypass

Difference in degree of A-V block and QS2 abbreviation of ouabain digoxin and digitoxin in cats.

Six trained domestic cats received a spectrum of polar to nonpolar cardiac glycosides: ouabain, digoxin or digitoxin with medication free intervals of four weeks. Significant (P less than 0.01) rate reduction (-19 +/- 8%) and prolongation of PR interval (+13 +/- 5%) occurred with ouabain and with digoxin (-18 +/- 5% and +13 +/- 3%) but not with digitoxin (-6 +/- 4% and +6 +/- 5%). However, rate corrected QS2 abbreviation was greater with digitoxin (-13 +/- 3%) than with ouabain (-8 +/- 3%) or digoxin (-10 +/- 5%). The findings indicate that in cats the polar cardiac glycosides ouabain and digoxin produce greater prolongation of A-V conduction while the nonpolar glycoside digitoxin produces greater abbreviation of QS2. Previously this finding was reported by the authors in guinea-pigs and in rabbits and has since been reported in intact rats, dogs, and in man by other authors. Investigators using nonintact subjects have not been able to demonstrate the finding. The differences may have clinical significance and suggest new insight into structural/activity relationships within the cardiac glycoside family.

Animals

Clinical implications of differences in pharmacodynamic action of polar and nonpolar cardiac glycosides.

The principal effects of cardiac glycosides probably can be classified as parasympathomimetic or sympathomimetic. Data from animals and from man suggest that polar cardiac glycosides, such as ouabain and digoxin, possess greater parasympathomimetic (vagal) cardiac effect for a given amount of sympathomimetic (positive inotropic) cardiac effect than do less polar cardiac glycosides, such as digitoxin. Polar glycosides therefore offer some advantage in uncomplicated paroxysmal atrial tachycardia and in uncomplicated atrial flutter and atrial fibrillation when the principal desired effect is reduction in the number of atrial impulses reaching the ventricles or conversion to normal sinus rhythm. Non-polar glycosides offer an advantage when positive inotropicity is desired but when there is some degree of atrioventricular block or when inappropriate sinus bradycardia or anorexia, nausea, or vomiting are present. Ecotopic impulse formation when due to cardiac glycosides is a toxic manifestation of excessive sympathomimetic effect, but is aggravated by vagal-induced sinus bradycardia, so that both parasympathomimetic and sympathomimetic capability of cardiac glycosides must be considered when dealing with myocardial electrical instability.

Animals

Pharmacodynamic distinctions between ouabain, digoxin and digitoxin.

Current pharmacologic texts recognize no significant pharmacodynamic differences between the various cardiac glycosides. To reconsider this concept, a special recording device was constructed so that electrocardiograms and phonocardiograms could be obtained in small mammals without anesthesia or premedication, and a spectrum of cardiac glycosides was studied. Utilizing guinea-pigs, cardiac rate reduction of 20% was sought and achieved with 0.07 mg/kg ouabain, 0.34 mg/kg digoxin and 1.12 mg/kg digitoxin. With comparable rate reduction, digitoxin produced significantly greater shortening of electro-mechanical systole than did ouabain or digoxin (P less than 0.05). Other authors have shown that cardiac glycosides produce slowing of cardiac rate prior to onset of positive inotropic effect. Therefore it is probable that for a given amount of vagal effect (sinoatrial slowing) digitoxin possesses greater positive inotropic effect (abbreviation of electromechanical systole) in guinea-pigs than do ouabain or digoxin. A review of the literature suggests that the same holds true for humans.

Animals