Search PubMed⌕ Search

Biomedical subjects

T M Chou

Publications and source records attributed to T M Chou.

At least 73 records · Page 4Linked to original sources

Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis.

BACKGROUND: Less invasive methods are replacing traditional invasive means of measuring coronary flow reserve (CFR). Transesophageal echocardiography (TEE) is becoming a useful tool for evaluation of coronary artery disease and has recently been used to measure CFR. This has always been done using dipyridamole, but adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole. This study was done to evaluate the hypothesis that adenosine is safe, rapid, and accurate in measuring coronary blood flow reserve by TEE Doppler. METHODS AND RESULTS: Forty-nine patients who had recently undergone angiography had a transesophageal echocardiogram with visualization of the coronary arteries and measurement of blood flow velocity in the left anterior descending coronary artery (LAD) during adenosine infusion of 0.14 mg/kg per minute. Angiograms were analyzed by quantitative coronary angiography, and significant stenosis was defined as > 70% lumenal diameter narrowing. Thirty-nine of the 49 patients did not have a significant LAD stenosis (group 1); the remainder had significant disease (group 2). Good spectral Doppler recordings of blood flow velocity in the LAD were obtained in 41 of 46 patients (89%). There were no significant differences in baseline coronary blood flow velocities between the two groups. Hyperemic to baseline flow ratios were significantly higher in patients without significant LAD stenosis for peak (2.83 +/- 1.04 versus 1.78 +/- 0.36) and mean (2.68 +/- 0.96 versus 1.75 +/- 0.39) diastolic velocity. A CFR ratio > 2.1 had a sensitivity of 86%, a specificity of 79%, a positive predictive value of 46%, and a negative predictive value of 96% for the absence of critical LAD stenosis. The infusion was well tolerated. It had to be prematurely terminated in only 3 patients (6.5%), and they were asymptomatic. No patient experienced chest pain, palpitations, or flushing. Intraobserver and interobserver variabilities were low, and reproducibility of data was good (< 4%). CONCLUSIONS: Adenosine Doppler TEE is an effective, rapid, safe, and superior means of measuring CFR ratio. This method is convenient for serial measurements of CFR as well as in clinical settings such as evaluation of syndrome X, cardiomyopathy, and aortic regurgitation.

Adenosine↗

Contribution of endothelium-derived nitric oxide to coronary arterial distensibility: an in vivo two-dimensional intravascular ultrasound study.

Reduced epicardial coronary arterial distensibility associated with early atherosclerosis may be mediated in part by reduced nitric oxide (NO) release. To directly assess the contribution of endogenous NO to coronary arterial distensibility, we examined the effect of intracoronary N omega nitro-L-arginine methyl ester (L-NAME), an inhibitor of NO synthase, and L-arginine, its natural substrate, on the circumflex artery in seven anesthetized dogs. We also used intracoronary acetylcholine to examine the effect of pharmacologically induced NO release on coronary distensibility. Electrocardiographically gated measurements of epicardial coronary lumen area were made by a blinded observer from images obtained with a 4.3F, 30 MHz intravascular ultrasound catheter. Aortic root pressure was continuously monitored, and neither systemic arterial pressure nor pulse pressure changed significantly with intracoronary drug administration. Change in lumen area (delta LA) from end systole to end diastole was measured, and an arterial distensibility index was calculated. Delta LA increased with acetylcholine from 8.2% +/- 0.5% at baseline to 16.3% +/- 2.8% (10(-6) mol/L; p < 0.001), with increases in both end-systolic and end-diastolic lumen area and decreased delta LA to 3.1% +/- 1.3% (p < 0.01). Lumen area and delta LA were both restored to baseline by L-arginine (10(-4)). The calculated distensibility index of the epicardial coronary artery was enhanced by acetylcholine, reduced below baseline by L-NAME, and restored to baseline by L-arginine.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetylcholine↗

Mechanisms of estrogen-induced vasodilation: in vivo studies in canine coronary conductance and resistance arteries.

OBJECTIVES: We sought to examine the immediate vasodilator effect of intracoronary estrogen on epicardial and resistance coronary arteries in 19 dogs. BACKGROUND: Although estrogen reportedly dilates coronary arteries in vitro, the site and mechanisms of its action have not been fully defined in vivo. METHODS: Epicardial coronary artery dimensions and coronary flow velocity were assessed using simultaneous intracoronary two-dimensional and Doppler ultrasound. RESULTS: Estrogen (0.1 and 1 mumol/liter) induced a significant increase in coronary cross-sectional area, flow velocity and volumetric blood flow. Estrogen-induced vasodilation was not influenced either by pretreatment with N omega-nitro-L-arginine methyl ester (L-NAME) (100 mumol/liter intracoronary), indomethacin (5 mg/kg body weight intravenously), propranolol (0.75 mg/kg intravenously) or the classic estrogen receptor antagonist ICI 182,780 (10 mumol/liter). Balloon denudation of the endothelium did not attenuate estrogen-induced epicardial vasodilation. Pretreatment with glibenclamide (10 mumol/liter) attenuated estrogen-induced vasodilation only in epicardial arteries, as did verapamil (0.1 mumol/liter). Estrogen had no effect on a phenylephrine dose-response curve in either epicardial coronary arteries or the microcirculation. CONCLUSIONS: Acute estrogen-induced dilation in canine coronary arteries is endothelium independent and is not mediated by the classic intracellular estrogen receptor but through non-genomic mechanisms, presumably at the membrane level, which in epicardial arteries may include effects on adenosine triphosphate-sensitive potassium or calcium channels, or both.

Analysis of Variance↗

Measurement of volumetric coronary blood flow by simultaneous intravascular two-dimensional and Doppler ultrasound: validation in an animal model.

We examined the accuracy and feasibility of using simultaneous intracoronary Doppler and two-dimensional (2D) ultrasound imaging in the measurement of volumetric coronary blood flow (CBF). A femoral artery-to-circumflex coronary artery shunt was created in four dogs with tubing that incorporated an in-line transit-time ultrasound (TTU) flow probe. A 2D ultrasound catheter was introduced over a 0.014-inch Doppler guide wire into the circumflex artery with the guide wire tip positioned 2 cm beyond the imaging catheter tip. Cross-sectional area (CSA) and average peak velocity (APV) were recorded. CBF was determined from the previously validated relation CBF = CSA x 0.5 APV and the adjusted measurement formula CBF = CSA x 0.47 APV. Within the 119 measurements made, TTU CBF varied from 31 to 385 ml/min. An excellent correlation was found between 2D/Doppler-derived and TTU CBF with both constants; measurement agreement was improved and bias minimal with the 0.47 constant (slope = 0.9997; r = 0.99; p < 0.0001; SEE = -6.7 +/- 8.6). We conclude that simultaneous 2D and Doppler ultrasound yields accurate estimates of volumetric CBF.

Animals↗

A diagnostic craniometric method for determining occlusal vertical dimension.

There is no precise scientific method for determining the correct edentulous occlusal vertical dimension. This study established the proportion between the ear-eye to chin-nose distance for determining reasonable occlusal vertical dimension. Two hundred white and 400 Asian men and women participated in this study. The ear-eye and chin-nose distances were measured with a modified craniometer. The results revealed that left ear-eye distance can be used to predict chin-nose distance with reasonable accuracy. However, the algorithm for making this prediction is not the same for combinations of sex and ethnic origin.

Adult↗

Cyclosporine impairs release of endothelium-derived relaxing factors in epicardial and resistance coronary arteries.

BACKGROUND: Cyclosporin A is reported to impair endothelium-mediated vasorelaxation and induce endothelin release in some noncoronary vascular beds. We wished to determine whether acute cyclosporine administration induces endothelial dysfunction in coronary conductance or resistance arteries. METHODS AND RESULTS: We examined the effect of intracoronary acetylcholine, N omega-nitro-L-arginine methyl ester (L-NAME), L-arginine, nitroglycerin, and adenosine before and after acute cyclosporine administration (3 mg/kg IV over 30 minutes) in anesthetized dogs. Flow velocity was measured with a 0.014-in Doppler wire to assess resistance vessel responses, and epicardial coronary lumen area was simultaneously measured with a 4.3F, 30-MHz imaging catheter inserted over the Doppler wire. In 6 dogs, acetylcholine-induced increase in flow velocity was attenuated by cyclosporine in vehicle (137% to 55% at 10(-5) mol/L, P < .001), as was acetylcholine-induced epicardial vasodilation (14.1% to 6.7% at 10(-5) mol/L, P < .001). Vasodilation in response to intracoronary nitroglycerin (200 micrograms) and adenosine (6 mg) were unchanged by cyclosporine. Epicardial vasoconstriction with L-NAME (10(-4) mol/L) was reduced by cyclosporine (Pre, 7.4 +/- 0.9%; Post, 2.6 +/- 1.2%; P = .04), but L-arginine (10(-4) mol/L) had no effect after cyclosporine. In another 5 dogs, pure cyclosporine impaired acetylcholine-induced vasodilatation to the same degree as cyclosporine in vehicle (Cremophor); vehicle infusion did not impair endothelial function. In 5 more dogs, cyclosporine did not increase either arterial or coronary sinus concentrations of endothelin-1. CONCLUSIONS: The present study shows that cyclosporine acutely impairs release of endothelium-derived relaxing factor in canine conductance and resistance coronary arteries and provides evidence for decreased epicardial nitric oxide release after cyclosporine. The potential contribution of acute cyclosporine-induced coronary endothelial dysfunction to posttransplant vasculopathy needs further study.

Acetylcholine↗

Caffeine and coffee: effects on health and cardiovascular disease.

Caffeine is a methylxanthine whose primary biological effect is the competitive antagonism of the adenosine receptor. Its presence in coffee, tea, soda beverages, chocolate and many prescription and over-the-counter drugs makes it a commonly consumed stimulant. Coffee and/or caffeine consumption has been linked to many human diseases in epidemiologic studies. Causal relationships have been difficult to substantiate. Initial investigations, showing an association between coffee and coronary heart disease, suffer from confounding variables and have been difficult to replicate. Recent studies, showing a significant effect over long follow-up periods and with high coffee intake, have again raised the question of a role for coffee and/or caffeine consumption in the pathogenesis of atherosclerotic heart disease. Contrary to common belief, the published literature provides little evidence that coffee and/or caffeine in typical dosages increases the risk of infarction, sudden death or arrhythmia.

Caffeine↗

Evaluating coronary artery disease noninvasively--which test for whom?

The generally accepted indications for stress testing in patients with coronary artery disease include confirming the diagnosis of angina, determining the limitation of activity caused by angina, assessing prognosis in patients with known coronary artery disease, assessing perioperative risk, and evaluating responses to therapy. In patients with a clinical scenario strongly suggestive of angina, testing is not necessary to diagnose coronary artery disease. The exercise treadmill-electrocardiogram test is the oldest and most extensively used stress test and can be reliably performed in patients who are clinically stable and who have an interpretable resting electrocardiogram. The addition of myocardial imaging agents such as thallium 201, technetium Tc 99m sestamibi, and technetium Tc 99m teboroxime increases the sensitivity and specificity for detecting coronary disease. Pharmacologic agents such as dipyridamole, adenosine, and dobutamine may be used in patients who cannot exercise adequately. Myocardial ischemia can also be evaluated by echocardiography, computed tomography, or magnetic resonance imaging, especially when additional information such as left ventricular and valvular function is desired. We review the indications for the noninvasive evaluation of coronary artery disease and the rationale for selecting a diagnostic test.

Adenosine↗

Molecular cloning of Chinese hamster metallothionein II gene and its 5' flanking region.

A genomic DNA clone containing Chinese hamster metallothionein II (MTII) gene and its 5' flanking region was isolated from Cd resistant Chinese hamster ovary (CHO) cells. DNA sequence analysis showed that there are three exons and two introns in the structure of the MTII gene. Further characterization of the 5' flanking region reveals the possible transcription initiation site, metal responsive element and basal-level enhancer sequence. Putatively, this is the promoter region of CHO MTII gene.

Animals↗

Stereophotogrammetric analysis of abutment tooth movement in distal-extension removable partial dentures with intracoronal attachments and clasps.

This study applied the three-dimensional measurement technique of stereophotogrammetry to measure abutment tooth movement under occlusal loading as a function of intracoronal attachment and clasp design. Six distal-extension removable partial denture designs were studied: (1) RPI-mesial occlusal rest, proximal plate, buccal I-bar; (2) cast circumferential clasp; (3) P.D. locking semiprecision attachment; (4) Thompson dowel nonlocking semiprecision attachment; (5) McCollum precision attachment; and (6) Stern G/L precision attachment. The movement in microns was determined by computer analysis. The Thompson dowel semiprecision attachment generated the most abutment movement in a gingival direction. The clasp-retained designs generally had less total movement than the attachment designs. Clasps and attachments for the abutment teeth adjacent to the distal-extension bases generally moved more than the abutment teeth.

Analysis of Variance↗

Photoelastic analysis and comparison of force-transmission characteristics of intracoronal attachments with clasp distal-extension removable partial dentures.

This investigation photoelastically compared the load-transfer characteristics of various bilateral distal-extension removable partial denture designs embodying intracoronal attachments and clasp assemblies. Six distal-extension designs that included the RPI clasp assembly, cast circumferential clasp, P.D. locking semiprecision, Thompson dowel nonlocking semiprecision, and McCollum and Stern G/L precision attachments were tested. Each prosthesis was subjected to various simulated occlusal loads. Evaluation of the load-transfer characteristics of the various designs was based on comparison of the recorded isochromatic fringe distributions. The RPI clasp assembly generated the most uniform stresses. In general, the four intracoronal retainer frameworks produced higher stresses than did the two clasp frameworks. The highest stresses were developed by the Stern G/L precision attachment.

Bicuspid↗