Ergonovine maleate testing during cardiac catheterization: a 10-year perspective in 3,447 patients without significant coronary artery disease or Prinzmetal's variant angina.

The utility of ergonovine testing for coronary artery spasm was assessed in 3,447 patients with angiographically insignificant (less than 50% diameter stenosis) or no coronary artery disease. No patients clinically had Prinzmetal's variant angina. Overall, 4% had a positive ergonovine test result, defined by spasm causing greater than or equal to 75% focal stenosis. Complications related to ergonovine use occurred in 11 patients (0.03%). In a training sample of 1,136 patients (studied between 1980 and 1984), two independent predictors of spasm were found by using multivariate analysis: the amount of visible coronary artery disease on the coronary angiogram (p less than 0.0001) and a smoking history (p = 0.001). A model to predict spasm based on these variables was validated in a test group of 2,311 patients who received ergonovine from 1985 to 1989. This model allowed the identification of a subset of 400 patients in the validation sample who had a 10% positive test rate compared with a 2% positive test rate in the remaining patients. These results should permit clinicians who use provocative testing in the catheterization laboratory to reserve testing for the subset of this group of patients most likely to have abnormal findings.

Angina Pectoris, Variant↗

Comparison of preload recruitable stroke work, end-systolic pressure-volume and dP/dtmax-end-diastolic volume relations as indexes of left ventricular contractile performance in patients undergoing routine cardiac catheterization.

The end-systolic pressure-volume relation, the relation between stroke work and end-diastolic volume, termed the preload recruitable stroke work relation, and the relation between the peak of the first derivative of left ventricular pressure (dP/dtmax) and end-diastolic volume have been employed as linear indexes of left ventricular contractile performance in laboratory animals. The purpose of this study was to examine the relative utility of these indexes during routine cardiac catheterization in seven human subjects (mean age 48 +/- 18 [SD] years) with a normal left ventriculogram and coronary angiogram. Left ventricular pressure was recorded continuously with a micromanometer catheter, and left ventricular volume was derived from digital subtraction contrast ventriculograms obtained at 30-ms intervals. Transient occlusion of the inferior vena cava with a balloon-tipped catheter was employed to obtain beat to beat reductions in left ventricular pressure and volume over 8.7 +/- 1.7 cardiac cycles. Stroke work declined by 49 +/- 13% during vena caval occlusion, but end-systolic pressure fell by only 26 +/- 11%, and changes in dP/dtmax were small and inconsistent (12 +/- 22%). Consequently, the range of data available for determination of the preload recruitable stroke work relation greatly exceeded that for the end-systolic pressure-volume relation and the dP/dtmax-end-diastolic volume relation, and much less linear extrapolation from the measured data was required to determine the volume-axis intercept. Preload recruitable stroke work relations were highly linear (r = 0.95 +/- 0.07), and much more so than end-systolic pressure-volume relations (r = 0.79 +/- 0.23).(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography, Digital Subtraction↗

Balloon mitral commissurotomy after previous surgical commissurotomy. The National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry participants.

BACKGROUND: Mitral restenosis after surgical mitral commissurotomy often occurs within 5-15 years, necessitating a repeat procedure. Balloon mitral commissurotomy (BMC) has been advocated as an alternative to repeat surgery for mitral restenosis. METHODS AND RESULTS: The purposes of this study are to determine the short- and intermediate-term outcomes of patients undergoing BMC after previous surgical commissurotomy, to compare these patients with those undergoing balloon mitral commissurotomy as an initial procedure, and to elucidate the multivariate determinants of acute procedural and clinical outcome. Of 738 patients undergoing BMC as part of the National Heart, Lung, and Blood Institute Balloon Valvuloplasty Registry, 133 underwent BMC after previous surgical mitral commissurotomy. Prospective data obtained included demographic, hemodynamic, echocardiographic, and clinical follow-up. BMC after previous surgical commissurotomy produced a significant reduction in transvalvular gradient from 13 +/- 5 to 6 +/- 3 mm Hg (p less than 0.0001) and an increase in mitral valve area from 1.0 +/- 0.3 to 1.8 +/- 0.8 cm2 (p less than 0.0001). BMC as an initial procedure increased valve area from 1.0 +/- 0.4 to 2.0 +/- 0.8 cm2 (p less than 0.0001) (p = 0.03 versus prior surgery). Baseline characteristics including mitral valve echo score were similar for both groups. Comparing 6-month status in patients with prior surgery to those without, 80% versus 90% were New York Heart Association (NYHA) functional class I or II (p = 0.004). Mortality was similar. In patients with previous mitral valve surgery, multivariate predictors of improvement in 6-month clinical status included the experience of the center (p = 0.006), lower echocardiographic score (p = 0.001), and lower left ventricular end-diastolic pressure (p = 0.008). Multivariate determinants of a final mitral valve area greater than or equal to 1.5 cm2 were a lower baseline NYHA functional class (p = 0.003) and lower mitral valve echocardiographic score (p = 0.008). CONCLUSIONS: BMC after previous surgical mitral commissurotomy results in similar hemodynamic changes as in patients undergoing BMC as an initial procedure. Symptomatic improvement at 6 months is slightly less frequent in prior commissurotomy patients. Patients with favorable valvular morphology and preserved left ventricular function who undergo BMC in experienced centers are most likely to achieve symptomatic improvement after previous surgical commissurotomy. In general, BMC is an effective treatment for mitral restenosis after previous surgical commissurotomy.

Catheterization↗

Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.

To investigate complementarity and competitiveness between the intrinsic and extrinsic components of the total left ventricular systolic load, hemodynamic data from 18 elderly subjects with severe aortic stenosis were analyzed before and after balloon dilation of the stenosed aortic valve. Multisensor micromanometric pressure measurements allowed calculation (simplified Bernoulli equation) of the ejection velocity and aortic input impedance spectra. Despite a 32% increase in the aortic valve area (from 0.56 +/- 0.04 to 0.74 +/- 0.05 cm2 [mean +/- SEM], p < 0.01), the peak left ventricular systolic pressure fell by only 12% (from 189 +/- 10 to 167 +/- 8 mm Hg, p < 0.01). This was accompanied by an increase in the impedance at the same cardiac output. In a subset of patients (n = 9) in whom the peak aortic systolic pressure rose after valvuloplasty (from 115 +/- 10 to 128 +/- 12 mm Hg, p < 0.01), a 40% increase in the aortic valve area was accompanied by a marked increase in the aortic input impedance. In this subset, the steady component of the aortic input impedance increased by 24% (from 960 +/- 96 to 1,188 +/- 134 dyne.sec/ml, p < 0.05), and the characteristic impedance increased by 25% (from 106 +/- 13 to 132 +/- 19 dyne.sec/ml, p < 0.05). Because of an increased aortic impedance acutely following the procedure, the total left ventricular systolic load after balloon dilation of the stenotic valve was only slightly decreased despite a significant increase in aortic valve area. This represents an example of complementarity and competitiveness between the intrinsic and extrinsic components of the total systolic ventricular load. It may explain why improvement in left ventricular performance may be modest acutely following balloon aortic valvuloplasty.

Aged↗

Critical mitral stenosis causing ischemic hepatic failure. Successful treatment by percutaneous balloon mitral valvotomy.

We report a 52-year-old patient with severe mitral stenosis who developed new onset atrial fibrillation, low output congestive heart failure and fulminant ischemic hepatic failure with subsequent severe coagulopathy. Percutaneous mitral valvotomy resulted in dramatic clinical improvement with complete resolution of liver function. This case illustrates the potential life-saving role for percutaneous balloon mitral valvotomy in treating critically ill patients who are unable to undergo thoracotomy due to coexisting medical illness.

Atrial Fibrillation↗

Renal artery stenosis: prevalence and associated risk factors in patients undergoing routine cardiac catheterization.

The purposes of this study were to determine the prevalence of angiographically significant renal artery stenosis in a patient population referred for diagnostic cardiac catheterization and to develop a model that predicts the highest-risk subset of patients who have significant renal artery narrowing. A prospective validation cohort study was undertaken in a referral-based university hospital. After left ventriculography, abdominal aortography was performed to screen for the presence of renal artery disease. A convenience sample of 1,302 of 1,651 consecutive patients undergoing diagnostic cardiac catheterization were enrolled in the study. Of the 1,302 abdominal aortograms performed, 1,235 (95%) were deemed of adequate quality for the evaluation of renal artery anatomy. Renal artery disease was identified in 30% of the patients. Insignificant renal artery stenosis was found in 187 (15%) and significant (greater than or equal to 50% diameter narrowing) stenosis was found in 188 (15%). Significant unilateral disease was present in 11%, and bilateral disease was present in 4%. By univariable and multivariable logistic regression analysis, the association of both clinically and catheterization-derived variables with renal artery disease was assessed. Multivariable predictors included age, severity of coronary artery disease, congestive heart failure, female gender, and peripheral vascular disease. Hypertension was not an associated variable. These data reveal the previously undetected high prevalence of renal artery disease in patients undergoing cardiac catheterization and provide clinical and angiographic features that assist in predicting its presence.

Aged↗

Doppler echocardiographic findings in adults with severe symptomatic valvular aortic stenosis. Balloon Valvuloplasty Registry Echocardiographers.

Baseline echocardiographic data in 680 adults (mean age 78 years) undergoing balloon aortic valvuloplasty at 24 medical centers were analyzed to describe the degree of outflow obstruction in patients with symptomatic aortic stenosis. Maximal aortic jet velocity ranged from 2.3 to 6.6 m/s (mean 4.4 +/- 0.8) and continuity equation valve area ranged from 0.1 to 1.4 cm2 (mean 0.6 +/- 0.2). Of note, 36% had a jet velocity less than or equal to 4.0 m/s but only 3% had a valve area greater than 1.0 cm2 due to a high prevalence of impaired systolic function (54%). Outflow tract diameter was poorly correlated with body surface area (p = 0.26), although the group mean diameter was smaller in women than in men (1.9 +/- 0.2 vs 2.1 +/- 0.3 cm, p = 0.0001). Mean pressure gradient was related closely to maximal gradient (r = 0.92) and to maximal jet velocity (mean delta P = 2.4 V2 + 0.75 mm Hg). Simpler measures of aortic stenosis severity were correlated with Doppler and invasive valve area as follows: maximal jet velocity (r = -0.36 and -0.32), mean gradient (r = -0.33 and -0.29), outflow tract to jet velocity ratio (r = 0.67 and 0.40), and the fractional shortening velocity ratio (r = 0.29 and 0.22). This study demonstrates marked variability in stenosis severity in symptomatic adults referred for balloon aortic valvuloplasty. The absence of a predictable relation between outflow tract diameter and body size emphasizes the importance of this measurement in each patient if definition of valve area is needed.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiography.

Using catheter outer diameter as a scaling device, quantitative coronary arteriography allows the precise and objective measurement of change in absolute dimensions of coronary arteries after mechanical or pharmacologic intervention. Because of variable density in the wall of the catheter, automated systems might vary in the determination of the outer catheter diameter. To examine this premise, catheters in a variety of French sizes from 6 manufacturers were injected with radiographic contrast and used as scaling devices for arterial phantoms of known geometric dimension. Radiographic diameters of the catheters were determined by applying the quantitative coronary arteriographic algorithm to the catheters using a calibration grid in the same field of view. The varying composition of the catheters resulted in differing x-ray attenuation and, subsequently, automated edge-detection algorithms varied widely in determining the actual catheter diameter to be used as a scaling factor. For instance, a Lucite "artery" with a minimal luminal diameter of 1.50 mm (image calibrated using the micrometer-determined outside diameter of a Baxter 8Fr guiding catheter) resulted in a quantitative angiographic diameter of 2.03 mm (overestimation by 35%). If the diameter of a similar size Shiley catheter was used to calibrate the image, a luminal diameter of 1.60 mm was determined: a difference of 0.43 mm based solely on differences in scaling catheter attenuation. These data suggest that a specific "fingerprint" for each catheter material and catheter French size exists, rendering generalizations about catheter size questionable. These observations are important for quantitative angiography where many brands and sizes of angiographic catheters are being used clinically.(ABSTRACT TRUNCATED AT 250 WORDS)

Calibration↗

Determinants of one-year outcome from balloon aortic valvuloplasty.

Balloon aortic valvuloplasty (BAV) has been a therapeutic alternative treatment for severe symptomatic aortic stenosis. Previous studies have been unable to predict 1-year outcome because of limited acute and follow-up clinical, invasive and echocardiographic data. The purpose of this study was to predict long-term outcome based on comprehensive data obtained at the time of valvuloplasty and at 3 and 6 months after the procedure. Of 170 consecutive patients undergoing BAV, 108 (mean age 78 years) were at least 1 year from their procedure. Prospective clinical, micromanometer hemodynamic, digital ventriculographic and echocardiographic/Doppler data were collected at baseline and immediately after the procedure. Echocardiographic data were also obtained at 3 and 6 months. With use of Cox model analysis, major events (defined as cardiac death [n = 30], aortic valve replacement [n = 21] or repeat BAV [n = 13]) were predicted by advanced age, baseline heart failure class, and baseline echocardiographic-determined diastolic left ventricular diameter. Only baseline left ventricular ejection fraction proved to be a significant predictor of cardiac death (p = 0.002) in a multivariate model. Absolute values after BAV (stroke work, first derivative of left ventricular pressure, valve area, end-systolic volume, Fick cardiac output, transvalvular gradient) and acute changes measured by catheterization or echocardiography did not provide additional predictive information over that of post procedure ejection fraction. Similarly, echocardiographic valve area and transvalvular gradient at 3 months added no further prognostic data. With an ejection fraction greater than or equal to 45% (n = 63), cardiac survival at 1 year was 80%, irrespective of age, sex, congestive heart failure class or severity of coronary artery disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Comparison of intravascular ultrasound, external ultrasound and digital angiography for evaluation of peripheral artery dimensions and morphology.

Validation of catheter-based intravascular ultrasound imaging has been based on comparisons with histology and digital angiography, each of which may have limitations in the assessment of arterial size and morphology. External, high-frequency ultrasound can accurately determine vessel dimensions and morphology and because, like ultravascular ultrasound, it also provides cross-sectional arterial ultrasound images, it may be a more appropriate technique for the in vivo comparison of arterial dimensions and morphology determined by intravascular ultrasound. Thus, intravascular ultrasound, external 2-dimensional ultrasound, Doppler color-flow imaging and digital angiography were compared for assessment of arterial dimensions and wall morphology at 29 femoral artery sites in 15 patients. Intravascular ultrasound and the other 3 imaging modalities correlated well in determination of lumen diameter (2-dimensional, r = 0.98, standard error of the estimate [SEE] = 0.14; Doppler color flow, r = 0.91, SEE = 1.11; angiography, r = 0.95, SEE = 0.91) and cross-sectional area (2-dimensional, r = 0.97, SEE = 0.04; Doppler color flow, r = 0.92, SEE = 0.14; angiography, r = 0.96, SEE = 0.08). However, lumen size measured by Doppler color flow was consistently smaller than that measured by the other 3 imaging modalities. Intravascular ultrasound detected arterial plaque at 15 sites, 5 of which were hypoechoic (soft) and 10 hyperechoic with distal shadowing (hard). Plaque was identified at 12 of 15 sites by Z-dimensional imaging (p = 0.30 vs intravascular ultrasound), but at only 6 of 15 sites by angiography (p = 0.003 vs intravascular ultrasound), only 1 of which was thought to be calcified plaque.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Surgical aortic valvuloplasty using the Cavitron Ultrasonic Surgical Aspirator: an invasive hemodynamic follow-up study.

Valve repair and calcium debridement in patients with calcific aortic stenosis, using the Cavitron Ultrasonic Surgical Aspirator (CUSA), results in a reduction in the aortic valve gradient while potentially avoiding long-term problems inherent to prosthetic valves. Invasive followup data in these patients has not previously been reported. Ten patients in whom CUSA debridement was performed underwent cardiac catheterization prior to and 8.0 +/- 2.5 months following the procedure. Compared to baseline, the aortic valve area significantly increased from 0.75 +/- 0.2 to 1.1 +/- 0.3 cm2 (p = 0.009) and the mean gradient was significantly reduced from 54 +/- 21 to 27 +/- 21 mmHg (p = 0.02) at followup. No significant change was noted in cardiac output, ejection fraction, left ventricular end systolic or diastolic volumes or left ventricular end diastolic pressure. However, 6 patients were found to have at least one grade worsening of aortic regurgitation. The development of increased aortic insufficiency in many patients after CUSA aortic valve debridement will likely limit this procedure's clinical utility.

Aged↗

Follow-up recatheterization after balloon aortic valvuloplasty. Mansfield Scientific Aortic Valvuloplasty Registry Investigators.

The results of recatheterization were assessed in a select group of 95 patients enrolled in the Mansfield Scientific Aortic Valvuloplasty Registry to determine whether any procedural or patient-related variables at baseline predicted either initial immediate or follow-up (6.2 +/- 3.3 months) results. At the follow-up catheterization, 39 (41%) of the patients were in improved condition and 56 patients (59%) had recurrence of symptoms, allowing for analysis of the effect of the procedure in two symptomatic patient subsets. In the total group the aortic valve area increased initially from 0.56 +/- 0.16 to 0.87 +/- 0.27 cm2 but partial return to the baseline valve area was evident at follow-up (0.63 +/- 0.25 cm2). Similarly, the mean aortic gradient initially decreased from 72 +/- 30 to 35 +/- 16 mm Hg but then increased to 55 +/- 25 mm Hg at follow-up. Neither the initial nor the late hemodynamic results appeared affected by any definable procedural variable at the time of valvuloplasty, including the maximal diameter of balloons, number of balloons simultaneously used, mean inflation time or total number of inflations. Such technical concerns also did not seem to affect short- or long-term outcome. Similarly, no baseline hemodynamic variable clearly separated those who became increasingly symptomatic from those whose condition was improved at the 6 month interval. At recatheterization, a reduction in the aortic valve area toward baseline was observed in 24 (62%) of the 39 improved patients and in 45 (80%) of the 56 who were symptomatic.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

ACC/AHA guidelines for cardiac catheterization and cardiac catheterization laboratories. American College of Cardiology/American Heart Association Ad Hoc Task Force on Cardiac Catheterization.

It is evident that the practice of cardiac catheterization has undergone, and continues to undergo, marked change. Most prominent are the recent very rapid proliferation of catheterization laboratories in general and the development of newer types of catheterization laboratory. No uniform definitions exist for these newer laboratories, so meaningful communication is difficult. The new settings are of particular concern because their location, mobility, organization, and ownership raise questions about the quality of patient care. Most difficult to address are the questions about patient safety and physician conflict of interest. There are no objective data in peer-reviewed literature to support the reported safety and cost savings of these newer settings. Through deliberations, surveys, interviews, and correspondence with the cardiology community embraced by the ACC and the AHA, the task force generally found that in freestanding catheterization laboratories, access to emergency hospitalization may be delayed, and appropriate oversight may be lacking. Additionally, opportunities for self-referral may be fostered and the perception of commercialism and entrepreneurial excess in practice created. All of these problems must be avoided. The growth and development of some freestanding facilities, particularly the mobile laboratories, do not seem to have been driven by an increased need in remote communities or for temporary support but rather almost exclusively by a desire to capture market share. Accordingly, a series of definitions, guidelines, and recommendations for the laboratories as well as for patient selection has been developed. The consensus was that a very restrictive and cautious attitude to the newer settings is appropriate at this time. The justification for development or expansion of cardiac catheterization services must be patient need. Documentation of this need must be based on objective estimates of the number of patients with known or suspected cardiac disease who meet generally accepted indications for laboratory study. Concerns about the lack of data from prospective clinical trials of patient safety in such a group necessitate a very cautious attitude toward any new catheterization services, in particular those without in-house cardiac surgical support. In view of the lack of appropriately controlled safety and need data for hospital-based, mobile, or freestanding laboratories operating without on-site (accessible by gurney) cardiac surgery facilities, the task force reaffirms the position that further development of these services cannot be endorsed at this time. In addition, there is reason for major concern that such proliferation in catheterization services may contribute to increasing costs and troubling ethical questions.

American Heart Association↗

Early and late changes in left ventricular systolic performance after percutaneous aortic balloon valvuloplasty.

To evaluate early and late hemodynamics after aortic valvuloplasty, 17 patients underwent first-pass radionuclide angiocardiography with simultaneous high-fidelity micromanometer pressure before, 10 minutes after and 6 months after aortic valvuloplasty. Pressure-volume and stress data were assessed. Immediately after the procedure, no significant change was observed in heart rate, systemic blood pressure, cardiac output or aortic insufficiency (as measured by visual or quantitative aortography). The mean and peak transvalvular gradient decreased from 64 to 36 mm Hg (p less than 0.001) and 76 to 38 mm Hg (p less than 0.001), respectively. The mean aortic valve area increased from 0.5 to 0.8 cm2 (p less than 0.001). Using echocardiography, meridional end-systolic wall stress decreased from 81 to 63 x 10(3) dynes/cm2 (p less than 0.001). Left ventricular ejection fraction increased from 0.48 to 0.54 (p less than 0.01), end-diastolic volume decreased from 161 to 143 ml (p less than 0.001) and end-diastolic pressure decreased from 18 to 13 mm Hg (p less than 0.01). Left ventricular stroke work (the area of the pressure-volume loop) also decreased from 17.5 to 14.7 x 10(6) ergs (p less than 0.001). The loop shifted to the left and downward. At the 6-month study, the mean and peak aortic valve gradient increased from 36 to 56 mm Hg (p less than 0.001) and 38 to 61 mm Hg (p less than 0.001), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗