Search PubMed⌕ Search

Biomedical subjects

T Luukkainen

Publications and source records attributed to T Luukkainen.

At least 37 records · Page 2Linked to original sources

Levonorgestrel-releasing intrauterine device.

An intrauterine contraceptive device releasing 20 micrograms levonorgestrel daily has been studied for 15 years. The international clinical experience covers over 8000 woman years. Main characteristics of the levonorgestrel-releasing intrauterine device are its great effectiveness in preventing unplanned pregnancies and a reduction in menstrual bleeding and pain as well as a low infection rate.

Contraceptive Agents, Female↗

Interference with ovulation by sequential treatment with the antiprogesterone RU486 and synthetic progestin.

Seven healthy women were treated with the antiprogesterone RU486, 25 mg/d, on days 1 to 14 of the follicular phase of the menstrual cycle, followed by the synthetic progestin NET in the luteal phase of the cycle. Venous blood samples were collected twice per week. Serum E2, P, and RU486 concentrations were determined by RIAs, and FSH and LH by immunofluorometric assays. Ultrasonography was used to measure the sizes of the follicles. Serum concentrations of FSH and LH were not suppressed during the treatment. Ovulation was apparently suppressed during RU486 treatment according to E2 and P concentrations and ultrasonography findings. During NET treatment, some evidence of ovulation and follicle growth were found during the first treatment periods. During the third treatment cycle, there was no evidence of ovulation (n = 2). Estradiol concentrations were sufficient to stimulate normal proliferative growth of the endometrium during the treatment. Control of bleeding was good. The exact mechanism of action of RU486 on steroid synthesis and ovulation is not clear, but it appears to act at the ovarian level. The evidence indicates that sequential RU486/progestin treatment could be developed to result in suppression of follicular growth and ovulation.

Adult↗

Acceptability of an experimental intracervical device: results of a study controlling for selection bias.

We analyzed baseline and 12-month follow-up interview data from 98 women who had volunteered to use an experimental intracervical device (ICD) and from 155 women who had been randomly assigned to two control groups, the levonorgestrel-releasing intrauterine device (LNG-IUD; N = 86) and the copper Nova-T IUD (N = 69). All participants were clinic patients in Helsinki, Finland. Initial analysis of 12-month discontinuation data indicated that a significantly higher percent of ICD users (22.4) discontinued their device than did either LNG-IUD (7.0) or Nova-T (8.7) users. However, we were no longer able to detect significant differences in discontinuation after controlling for baseline variables that assessed predisposition to be dissatisfied with contraception in general. Adjusted probabilities of discontinuing the ICD, LNG-IUD, and Nova-T were 11.8%, 6.2% and 7.9%, respectively. These data indicate that the ICD is likely to be acceptable to Helsinki clinic patients; moreover, they suggest a definite place for hormonal intrauterine devices in the contraceptive armamentarium. Most importantly, the methodology used here can be generalized to acceptability studies of other contraceptive devices and drugs undergoing Phase I and early Phase II clinical trials (in situations where randomization may not be feasible) in order to identify and control for the bias introduced by nonrandom assignment procedures.

Adolescent↗

Plasma levonorgestrel levels and ovarian function during the use of a levonorgestrel-releasing intracervical contraceptive device.

Levonorgestrel, estradiol and progesterone plasma concentrations were measured over four years of use of a 20 micrograms/day levonorgestrel-releasing intracervical device (LNG-ICD). The mean levonorgestrel concentration showed a slight decline, being 142 + 46 (SD) pg/ml in the third month and 81 +/- 22 pg/ml in the 48th month of LNG-ICD use. However, considerable interindividual variation in levonorgestrel plasma levels between study subjects was observed. In 77% of the monitored cycles, ovulation or a luteinized follicle was observed when judged by a plasma progesterone elevation of over 5 ng/ml. Some follicular function was also noted in anovulatory cycles. Inhibition of ovulatory ovarian function is not the mode of contraceptive action of the LNG-ICD.

Adult↗

Inhibition of folliculogenesis and ovulation by the antiprogesterone RU 486.

Healthy, regularly menstruating women were treated with the antiprogesterone RU 486, Mifepristone (Roussel-Uclaf, Romainville, France) during the follicular phase of the cycle. Three women were given 25 mg of RU 486 on days 1 to 14 of the cycle and five received 25 mg on days 1 to 21 of the cycle. Venous blood samples were collected three times per week during a control cycle and during one treatment cycle in each subject. Serum concentrations of estradiol (E2), progesterone (P), and RU 486 were determined by radioimmunoassays. No drug-related side effects and no spotting or bleeding during RU 486 treatment were observed. Menstrual bleeding was delayed by 8.7 +/- 3.8 days (mean +/- SD) after treatment over days 1 to 14 and by 12.6 +/- 3.2 days after treatment over days 1 to 21. During the treatment with RU 486, the serum concentrations of E2 remained low, indicating effective inhibition of folliculogenesis. After cessation of RU 486 treatment, serum E2 levels rose to similar values as in the control cycle, and subsequently serum P concentrations also reached ovulatory levels in six out of the eight volunteers. The results showed that the antiprogesterone RU 486 delayed folliculogenesis and luteinization even at low doses when given during the follicular phase of the menstrual cycle. It is speculated that this property of RU 486 could be utilized in the design of an estrogen-free combined oral contraceptives.

Adult↗

Effective contraception with the levonorgestrel-releasing intrauterine device: 12-month report of a European multicenter study.

The use-effectiveness of an intrauterine contraceptive device releasing 20 mcg of levonorgestrel daily (Lng-IUD), and of a Nova T copper-releasing IUD, were studied in a randomized, comparative multicenter trial. The Lng-IUD was inserted in 1821, and the Nova T in 937 women. The 12-month net pregnancy rate with the Lng-IUD (0.1 per hundred women) was significantly lower than that with the Nova T (0.9 per hundred). Removal rates for menstrual problems and/or pain were similar for the two methods (net rates 7.5 and 8.7, respectively). The 12-month continuation rates were 82.2 for the Nova T and 79.7 for the Lng-IUD. The reduction of the bleeding led to oligomenorrhea and amenorrhea in users of the Lng-IUD; the removal rate for these reasons was 1.4. The removal rate for hormonal side effects with the Lng-IUD was 2.4. Blood hemoglobin concentrations increased among users of the Lng-IUD and decreased among users of the Nova T. The results show that the Lng-IUD was a highly effective contraceptive method which reduced menstrual bleeding. It is a promising alternative for women desiring a highly effective method for long-term use.

Adult↗

Plasma concentrations and receptor binding of RU 486 and its metabolites in humans.

Using Chromosorb chromatography and HPLC, we measured the plasma concentrations of RU 486, and its monodemethylated (RU 42633), didemethylated (RU 42848) and alcoholic nondemethylated (RU 42698) metabolites up to 72 h following oral ingestion of 100 mg of RU 486 by five female volunteers. The peak plasma level of RU 486 (4.5 mumol/l) occurred within 1 h after ingestion of the compound; at this point significant amounts of the metabolites were also present in the plasma. After the initial redistribution within 6 h the plasma concentrations of RU 486 and three of its metabolites measured remained stable for 24 h. Concentrations of the monodomethylated metabolite exceeded those of the parent steroid during the time period measured, whereas the concentrations of the didemethylated and alcoholic metabolites were lower than those of RU 486, but still notable. At 72 h the concentrations of all the four steroids were still in the micromolar range. The relative binding affinities of these metabolites to human endometrial and myometrial progesterone receptors as well as to human placental glucocorticoid receptors were determined in vitro. The affinity of RU 486 for the human uterine progesterone receptor (Kd = 1.3 X 10(-9) M for RU 486) was higher than that of progesterone but lower than that of ORG-2058, a potent synthetic progestin. The relative binding affinities of the monodemethylated, alcoholic and didemethylated metabolites to the progesterone receptor were 21, 15 and 9%, respectively, compared with the parent compound RU 486; each was lower than that of progesterone (43%). RU 486 had an approx. 4-fold higher relative binding affinity to the glucocorticoid receptor than dexamethasone. Interestingly, the relative binding affinities of the metabolites studied to the human glucocorticoid receptor exceeded those of dexamethasone or cortisol. Compared with the parent compound RU 486, they were 61, 48 and 45% for the monodemethylated, alcoholic and didemethylated metabolites, respectively; each was higher than that of dexamethasone (23%). The affinity of dexamethasone to the human glucocorticoid receptor was 1.6 X 10(-9) M. These data indicate that the pool of certain metabolites of RU 486 may contribute to a significant extent to the antiprogestagenic (23-33%) and even greater extent to the antiglucocorticoid (47-61%) effects of RU 486.

Binding, Competitive↗

Pharmacokinetics and metabolism of RU 486.

The effects of dose on the initial pharmacokinetics and metabolism of an antiprogesterone steroid RU 486 (mifepristone) were studied in healthy female volunteers after administration of RU 486 as a single dose of 50-800 mg. The concentrations of RU 486 and its monodemethylated, dimethylated and hydroxylated non-demethylated metabolites were measured specifically after Chromosorb-column chromatography by HPLC. Their relative binding affinities to the human uterine progesterone receptor were also determined. Micromolar concentrations of the parent compound in blood were reached within the first hour after oral administration. The pharmacokinetics of RU 486 followed two distinct patterns in a dose-dependent fashion. With a low dose of 50 mg the pharmacokinetics followed an open two-compartment model with a half-life of over 27 h. With the doses of 100-800 mg the initial redistribution phase of 6-10 h was followed by zero-order kinetics up to 24 h or more. Importantly, after ingestion of doses higher than 100 mg of RU 486 there were no significant differences in plasma concentrations of RU 486 within the first 48 h, with the exception of plasma RU 486 concentrations at 2 h. After single oral administration of 200 mg unchanged RU 486 was found 10 days later in two subjects. The elimination phase half-life with this dose, calculated between day 5 and 6, was 24 h. Micromolar concentrations of monodemethylated, didemethylated and non-demethylated hydroxylated metabolites were measured within 1 h after oral administration of RU 486. In contrast to plasma RU 486 concentrations, circulating plasma concentrations of metabolites increased in a dose-dependent fashion. With higher doses the metabolite concentrations were close to, or even in excess to the parent compound. The relative binding affinities of RU 486, monodemethylated, didemethylated and hydroxylated metabolites (progesterone = 100%) to the human progesterone receptor were 232, 50, 21, and 36, respectively. The existence of a high affinity-limited capacity serum binding protein would explain the long half-life and the observed diverging dose-dependent pharmacokinetics. The extravasation of RU 486 after the saturation of serum binding sites would explain the blunted serum peak concentrations of RU 486 with higher doses. The return of the drug back to circulation thereafter explains the zero-order kinetics. High concentrations of circulating metabolites capable of binding to the progesterone receptor suggest a significant contribution of these steroids in the overall antiprogestational action.

Adult↗

Metabolism and serum binding of RU 486 in women after various single doses.

The metabolism of RU 486 was studied in female volunteers following a single oral administration of 100, 400, 600 or 800 mg of RU 486. The serum concentrations of RU 486 were generally not affected by the dose within the range examined and they stayed at micromolar concentrations during the 48 h studied. RU 486 was metabolized extensively in a dose-dependent manner by two-step demethylation, and by hydroxylation. Serum levels of the monodemethylated metabolite always exceeded those of RU 486. The concentrations of the didemethylated and hydroxylated metabolites equalled or exceeded those of RU 486 when the ingested dose was 400 mg or more. Monodemethylation and hydroxylation were rapid high-capacity reactions, whereas didemethylation was a lower-capacity reaction. In each group of different dosage, positive correlations were found between the individual mean alpha 1-acid glycoprotein (AAG) concentrations and the peak concentration of RU 486 measured at 1-2 h, versus the plateau concentration of RU 486 measured at 6 h. The in-vitro studies showed that the specific serum transport protein of RU 486, AAG, was saturated by RU 486 concentrations exceeding 2.5 microM. In serum at 40 nM and 2.5 microM RU 486 concentrations, 2.7% and 2.4%, respectively, of [3H]RU 486 was not protein bound. Purified AAG in phosphate buffer was able to bind [3H]RU 486 in a similar manner to that of serum. Thus our results suggest that AAG regulates in part the serum concentrations of RU 486, and RU 486 exceeding the specific serum transport capacity is effectively metabolized.

Administration, Oral↗

Intravaginal administration of RU 486 in humans and rats: inadequate absorption in humans.

Vaginal absorption of the antiprogesterone steroid RU 486 was studied in humans and rats. In rats, RU 486 was sufficiently absorbed to terminate early pregnancy following vaginal, oral or intramuscular administration. The quantitation of RU 486 in serum showed that the ratios of the areas under the concentration curves per mg administered were 1:2.8:3.4 for the vaginal, intramuscular and oral routes, respectively. Female volunteers received RU 486 vaginally in polyethylene glycol (PEG) suppositories, in tampons and in oil solution. Following vaginal (PEG-suppository) and oral administration of 100 mg of RU 486, the ratio of the areas under the serum concentration curves was 1:56, respectively. From tampons and oil, RU 486 was absorbed in a similar manner to that of the PEG-suppositories, resulting in nanomolar serum concentrations. In humans no biological effects were noted following vaginal administration of RU 486. These data suggest that vaginal release of RU 486 is not a successful route of administration in humans.

Administration, Intravaginal↗

[Hormonal coils].

Explore the source record for details and available documents.

Contraceptive Agents, Female↗

Five years' experience with levonorgestrel-releasing IUDs.

Two levonorgestrel-releasing IUDs and a copper-releasing IUD of the same shape were studied in a randomized comparative study over five years. The levonorgestrel-releasing IUDs released 20 micrograms or 30 micrograms per day. The Pearl index during the 10,600 woman-months of LNG-IUD use was 0.11. The control device releasing copper had a Pearl index of 1.6. The amount and duration of menstrual bleeding was greatly reduced, leading to a high incidence of oligo- or amenorrhea. The continuation rate in this pioneer trial was 53 per 100 users for the levonorgestrel-releasing IUD (LNG-IUDs) and 50 per 100 users for the copper-releasing IUD (Nova T). The removal rates for reasons other than amenorrhea were not significantly different. Discontinuation because of amenorrhea occurred during the first two years, the cumulative termination rate for this reason was 11.6 per 100 users at five years. The LNG-IUDs removed for investigation after five years of use revealed that the devices contained about 40 percent of the original load. The effective lifespan of the device has been demonstrated by this study to be five years; the residual steroid gives an additional safety period of two more years. The LNG-IUD is a highly effective reversible contraceptive method, which strongly reduced the amount and duration of bleeding. During the first two months there is scanty but frequent spotting which, like the high incidence of oligo- and/or amenorrhea, requires counselling of health personnel and women using LNG-IUDs.

Adult↗

Sustained intrauterine release of levonorgestrel over five years.

Two models of levonorgestrel-releasing intrauterine devices were studied. Model A was designed to deliver 20 micrograms/day, and model B was designed to deliver 30 micrograms/day. Plasma concentrations of levonorgestrel were determined in blood samples taken from women who used the levonorgestrel-releasing intrauterine devices (IUDs) and who participated in a clinical trial for more than 5 years. During clinical studies IUDs have been removed for various reasons between 8 and 40 months after insertion. The rate of release of levonorgestrel from the IUDs was calculated by determining the remaining amount of levonorgestrel. Plasma concentrations of levonorgestrel ranged between a mean +/- standard deviation (SD) concentration of 166 +/- 75 pg/ml and 131 +/- 32 pg/ml for the first 18 months of use and between 101 +/- 37 pg/ml and 74 +/- 15 pg/ml at 24 and 60 months after insertion of the IUD. The plasma concentrations from 24 months through 60 months were significantly lower than concentrations measured during initial months of IUD use, but not between the two devices. There was a strong correlation between the time of use and the amount of levonorgestrel lost from the IUDs. The calculated mean daily release of levonorgestrel was 17.6 micrograms for model A and 22.2 micrograms for model B. This gives a calculated lifetime of more than 6 years for a levonorgestrel-releasing IUD.

Clinical Trials as Topic↗

Endometrial morphology during long-term use of levonorgestrel-releasing intrauterine devices.

Levonorgestrel-releasing intrauterine devices (IUD) were inserted in 92 women. Endometrial biopsies were taken between 3 months and 7 years after these insertions. Intrauterine release of levonorgestrel resulted in endometrial glandular atrophy and decidualized stroma. Inflammation and necrosis were also seen as local signs of IUD use. The biopsies were similar regardless of the duration of IUD use. Endometrial morphology returned to normal in biopsy specimens taken 1-3 months after IUD removal.

Adolescent↗

Hydrolysis of phospholipid monolayers by human spermatozoa. Inhibition by male contraceptive gossypol.

Monomolecular films of phospholipid were used to study the interaction of intact human spermatozoa with model membranes. Exclusively with negatively charged phosphatidylglycerol monolayers rapid penetration of spermatozoa into the monolayer with subsequent hydrolysis of the lipid was triggered by the addition of 5 mM calcium into the medium. The results suggest the localization of a calcium-dependent phospholipase A2 at the outer acrosomal or plasma membrane of human spermatozoa with its active site exposed to the external environment. Preincubation of the cells with 100 microM gossypol completely abolished the ability of human spermatozoa to hydrolyze or penetrate monolayers of phosphatidylglycerol. The inhibition of the phospholipase activity by gossypol may contribute to the unknown contraceptive mechanisms of this non-steroidal male antifertility agent.

Gossypol↗

Contraception with subdermal ST-1435 capsules: side-effects, endocrine profiles and liver function related to different lengths of capsules.

One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.

Adult↗