Evaluation of the APEC analyzer for whole blood glucose. Testing in a pediatric setting.

The APEC glucose analyzer (APEC, Danvers, MA) was analyzed in a pediatric clinical chemistry laboratory and its performance was compared with glucose determinations on the YSI 2300 STAT analyzer (Yellow Springs Instrument [YSI], Yellow Springs, OH). One hundred sixty-nine samples were simultaneously analyzed by the APEC and the YSI systems. The agreement between the two analyzers was excellent, with r = 0.986, slope = 1.04, and y intercept = -0.094. Analysis of the run-to-run precision yielded a CV of < or = 4.1% for both the APEC and the YSI instruments. Both analyzers displayed a sensitivity to at least 1.1 mmol/L (20 mg/dL) and both produced a linear response up to 27.8 mmol/L (500 mg/dL). Neither instrument was affected by icteric or hemolyzed samples. Variations in the patient's hematocrit did not lower the whole blood glucose values when these were compared with the equivalent plasma levels. In conclusion, the APEC glucose analyzer is suited for whole blood glucose testing in pediatric settings.

Blood Chemical Analysis↗

Assessment of the immunoreactivity of digoxin metabolites and the cross-reactivity with digoxin-like immunoreactive factors in the Roche-TDM ONLINE digoxin assay.

Immunoassays for digoxin measurement have long had the problem of low specificity. Antisera used in these assays may not only measure digoxin and the active metabolites but also cross-react with the noncardioactive metabolites and digoxin-like immunoreactive factors (DLIFs). In this study, we describe the analytical performance of the newly introduced Roche-TDM ONLINE digoxin assay on the COBAS FARA II centrifugal analyzer. The assay possessed linearity up to 5.0 ng/ml, sensitivity of 0.19 ng/ml, average recovery of 100.4%, and day-to-day variability of < 6%. The assay demonstrated no cross-reactivity with DLIFs or spironolactone and its metabolites and negligible reactivity with the digoxin noncardioactive metabolites. In addition, the immunoreactivity of the digoxin active metabolites reflected their cardioactivity. We conclude that the Roche-TDM ONLINE digoxin assay is highly specific and precise and suitable for the therapeutic monitoring of this drug.

Antibodies, Monoclonal↗

HPLC measurement, blood distribution, and pharmacokinetics of oral clotrimazole, potentially useful antisickling agent.

Clotrimazole (CLT) has recently been shown to be a potent and specific inhibitor of the Ca(2+)-activated K+ channel and to thereby prevent K+ loss and cellular dehydration of sickled erythrocytes. This evidence suggests that oral CLT may be a useful new therapy for sickle cell disease. Here, we describe the development of an HPLC assay to measure CLT, a method we used to study the pharmacokinetics and transport of CLT in normal volunteers. The assay's linear range extended to 10 mumol/L; the detection limit was 0.1 mumol/L, analytical recovery 97.7%, and run-to-run imprecision (CV) < 4.7%. In unaffected subjects, CLT concentration peaked within 6 h of oral administration and returned to close to baseline by 24 h. High-density lipoproteins appear to be the main carriers of this drug in both normo- and hypertriglyceridemic plasma. We conclude that the method described here is ideally suited for therapeutic monitoring of CLT concentrations.

Adenosine Triphosphatases↗

Measurement of felbamate by wide-bore capillary gas chromatography and flame ionization detection.

Felbamate, a newly developed antiepileptic agent, has been demonstrated to control partial and generalized seizures effectively. We have developed a gas-chromatographic method for the determination of felbamate, using a wide-bore capillary column, a flame ionization detector, and a simple extraction procedure. The assay day-to-day precision (n = 20) was 5.2% and 3.6% for drug concentrations of 50 and 150 mg/L, respectively; average recovery over a wide range of felbamate concentrations was 95%; the detection limit was 5 mg/L; and assay linearity extended to 300 mg/L. Although 9 of the 27 drugs tested were coextracted with felbamate, they exhibited significantly different retention times and showed no interference. A short-term stability study showed that plasma felbamate is stable at 4, -20, or -78 degrees C for at least 1 month. Plasma felbamate concentrations in 66 pediatric patients ranged from 7 to 154 mg/L (mean +/- SD 44 +/- 24.7). We consider the method ideally suited for therapeutic monitoring of plasma felbamate concentration.

Anticoagulants↗

Stilbenes stimulate T84 Cl- secretion by elevating Ca2+.

Basolateral but not apical application of 10-200 microM 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid (DIDS) or 4-acetamido-4'-isothiocyanostilbene-2,2'-disulfonic acid (SITS) to T84 monolayers produced a transient increase in short-circuit current (Isc), followed by a sustained inhibition. 4,4'-Dinitrostilbene-2,2'-disulfonic acid (DNDS) had no effect. The increase in Isc produced by DIDS represents Cl- secretion and appears to result from Ca2+ elevation, because in all respects except time course the response to DIDS mimicked the response to the Ca(2+)-elevating agent thapsigargin. Fura-2 measurements established that thapsigargin elevates Ca2+ in T84 cells, but Ca2+ responses to DIDS could not be established directly because DIDS absorbs strongly at the critical wavelengths. Responses to DIDS and thapsigargin were 1) blocked by bumetanide; 2) not blocked by basolateral Ba2+; 3) completely nonadditive; 4) strongly synergistic with basal levels of Isc or with Isc increases produced by elevating adenosine 3',5'-cyclic monophosphate (cAMP; with forskolin) or guanosine 3',5'-cyclic monophosphate (with heat-stable enterotoxin); and 5) reversibly abolished by removal of basolateral Ca2+. Interactions between Ca2+ and cAMP-elevating agents strongly support a model of Cl- secretion in which apical Cl- conductance is activated by cyclic nucleotides but not by Ca2+ while basolateral K+ channels are activated by Ca2+. In contrast with this mechanism, whole cell patch-clamp recordings of nonconfluent T84 cells indicated that DIDS and other Ca(2+)-elevating agents stimulated an increase in Cl- conductance. Thus increases in cytosolic free Ca2+ in nonconfluent T84 cells activate conductances that differ from those in confluent monolayers.

4,4'-Diisothiocyanostilbene-2,2'-Disulfonic Acid↗

Fetal antigens on the surface of human lymphoid cells.

Human B-lymphoblastoid cells established in long-term culture from healthy adults carry surface components that are normally found in human fetal tissues at about 10 wk of age. These antigens are strongly expressed on neoplastic B lymphocytes but not on thymocytes or a cultured T-cell line. They are carried by a small subpopulation of normal adult peripheral blood lymphocytes as well.

Antigens↗

Fetal antigens in nonneoplastic conditions.

During studies that showed the presence of fetal antigens on the surface of human malignant melanoma tumor cells, polyvalent antisera specific for human fetal tissues of varying ages were developed. These reagents demonstrated varying patterns of expression of fetal antigens at different ages in various tissues of the human fetus. The possibility that nonneoplastic adult cells showing either maturation arrest or excessive proliferation also might express fetal antigens led to studies of human bone marrow. Although normal bone marrow cells expressed low levels of fetal antigens, large amounts were seen on bone marrow cells of patients with anemias due to iron, B12, or folic acid deficiencies, as well as on those with leukemia. Moreover, normal adult tissues adapted to long-term culture also expressed fetal antigens. After 3 weeks in organ culture adult human skin showed morphological changes similar to those seen in fetal periderm and strongly expressed fetal antigens. In addition, lymphoblasts in long-term cultured human lymphoid cell lines established from normal donors also carried surface fetal antigens. These latter antigens were shared with neoplastic B-cells (chronic lymphocytic leukemia) but not with T-cells. Their expression varied with the cell cycle. The reexpression of fetal antigens on malignant cells is thought to signal a basic derangement in the control of differentiation which is considered to be peculiar to neoplasia. However, these studies indicate that normal adult cells also may reexpress fetal antigens under circumstances unrelated to neoplasia but associated with either maturation arrest or rapid and excessive proliferation.

Adult↗

Successful treatment of infantile hemangiomas with interferon-alpha-2b.

PURPOSE: Hemangiomas are benign tumors occurring in 10% of infants. A small percentage are complicated by blockage of vital structures, consumptive coagulopathy, or heart failure, resulting in a mortality of -20% of patients with complications. Here, we describe four infants with complicated hemangiomas responding to interferon-alpha-2b therapy. PATIENTS AND METHODS: Four children with hemangiomas were treated with interferon-alpha-2b for complicating heart failure (1), visual impairment (2), or coagulopathy (1). Patients received interferon-alpha-2b alone or in conjunction with corticosteroid therapy over 2 to 9 months. Imaging studies and urinary basic fibroblast growth factor (bFGF) levels were used to monitor treatment response. RESULTS: Three of four patients demonstrated involution of the hemangiomas with improvement in their coagulopathy or visual impairment. The fourth patient expired due to cardiac complications despite radiologic evidence of hemangioma involution. Side effects associated with interferon-alpha-2b treatment included elevated transaminases (2) and leukocytosis (2), which resolved upon completion of therapy. One patient developed mild gross motor delay (1), which improved after cessation of therapy. Decreased urinary bFGF levels correlated with hemangioma involution. CONCLUSION: Interferon-alpha-2b therapy is an effective, well-tolerated treatment for complicated hemangiomas. Measurement of urinary bFGF levels may provide an objective method for monitoring treatment response.

Exophthalmos↗

A new liquid homogeneous assay for HDL cholesterol determination evaluated in seven laboratories in Europe and the United States.

We evaluated a new liquid homogeneous assay for the direct measurement of high density lipoprotein cholesterol (HDL-C Plus) in seven laboratories. The assay includes two reagents which can be readily used in most available clinical chemistry analyzers. The total CVs of the new method were below 4.6% and the bias in relation to the designated comparison method was below 3.9%. The total error ranged between 4 to 7%. HDL-C values determined by this method were in good agreement with those obtained by the old homogeneous assay using lyophilized reagents, and other homogeneous and precipitation assays (0.944 < r < 0.996). The assay was linear up to at least 3.89 mmol/l HDL-C. Hemoglobin did not interfere, whereas in icteric samples slight deviations were observed. Lipemia up to 11.3 to 22.6 mmol/l triglycerides did not interfere with this homogeneous HDL-C assay. In samples of patients with paraproteinemia, discrepant results were seen. This liquid homogeneous HDL-C assay was easy to handle and produced similar results in all laboratories participating in this study. This method will enable clinical laboratories to reliably measure HDL-C for risk assessment of coronary heart disease.

Artifacts↗