High-definition television in medicine.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T Langø.
Explore the source record for details and available documents.
The main drawback with laparoscopic surgery is that the surgeon is unable to palpate vessels, tumours and organs during surgery. Further-more, the laparoscope only provides a surface view of organs. There is a need for more advanced visualizations techniques that can enhance the display presented to the surgeon so that important information below the surface of the organs is included when planning the procedure as well as for guidance and control during treatment. In this paper, we present a review of the literature and the state of art within image-guided laparoscopic surgery. We describe our own experience using a prototype navigation system for advanced visualizations and guidance during laparoscopic procedures in the retroperitoneum. Furthermore, we show sample images from the Future Operating Room for laparoscopic surgery in Trondheim, where this technology is being further developed and tested in clinical studies. Our system is based on three-dimensional navigation technology, i.e. preoperatively acquired magnetic resonance or computed tomography data used in combination with tracked instruments, allowing the surgeon to interactively control the display of images prior to and during surgery with normal use of the instruments. In summary, we believe that abdominal image navigation using tracked instruments and advanced visualizations has a large potential for improving future laparoscopic surgery, especially in cases where vessels and anatomical relations beyond surfaces is difficult to identify using only a laparoscope. The technology helps the surgeon to better understand the anatomy and locate blood vessels. Accordingly, we believe that this new technology could increase safety and make it easier for the surgeon to perform successful laparoscopic surgery.
BACKGROUND: The main drawback with the laparoscopic approach is that the surgeon is unable to palpate vessels, tumors, and organs during surgery. Furthermore, the laparoscope provides only surface view of organs. There is a need for more advanced visualizations that can enhance the view to include information below the surface of the organs for planning of the procedure and for control and guidance during treatment. METHODS: We propose three-dimensional (3D) navigation technology based on preoperatively acquired magnetic resonance or computed tomography data used in combination with a laparoscopic navigation pointer (LNP). The LNP has an attached position tracker that allows the surgeon to control the display of images interactively before and during surgery. This study evaluated the patient registration accuracy, the feasibility of image-based navigation and, qualitatively, the navigation precision in the retroperitoneum during laparoscopic surgery. RESULTS: This technology was used during the treatment of six patients (involving adrenalectomies and a neuroma protruding into the pelvis). An average patient registration accuracy of 6.90 mm was achieved. The precision during navigation in the retroperitoneum was, in some cases, better than the patient registration accuracy suggested. The technology helped the surgeons to understand better the anatomy and to locate blood vessels. CONCLUSIONS: In the reported cases, the LNP was a useful tool for image guidance in laparoscopic surgery, both for planning the surgical approach in detail and for guidance. The authors believe that adominal 3D image guidance using an LNP has a large potential for improving laparoscopic surgery, especially when vessels and anatomic relations may be difficult to identify using only a laparoscope. Accordingly, they believe this new technology could increase safety and make it easier for the surgeon to perform successful laparoscopic surgery.
BACKGROUND: The aim of the study was to compare three methods for ultrasound-based guidance of a radiofrequency probe into liver tumors in a model setup. METHODS: The liver model tumors were placed inside excised calf livers, and the radiofrequency probe was guided into the center using either a new 3D navigation method or two conventional 2D methods-freehand scanning and a method based on a biopsy guide. We performed 54 experiments, measuring the physical distance (all methods) and image distance (3D method only) from the tip of the probe to the center of the tumors. RESULTS: Based on the physical measurements alone, the biopsy-based guiding performed better than both the 2D freehand and the 3D navigation method. However, the 3D image measurements showed that the tip of the probe was better positioned in the center of the model tumors for the 3D navigation method as compared to the physical measurement results for the 2D methods. CONCLUSION: Although it was easier to position the radiofrequency probe accurately using the 3D image display technique, movement of the model tumor during 3D navigation is a challenge.
OBJECTIVE: This paper demonstrates a method that brings together three essential technologies for surgery planning and guidance: neuronavigation systems, 3D visualization techniques and intraoperative 3D imaging technologies. We demonstrate the practical use of an in-house interactive stereoscopic visualization module that is integrated with a 3D ultrasound based neuronavigation system. MATERIALS AND METHODS: A stereoscopy volume visualization module has been integrated with a 3D ultrasound based neuronavigation system, which also can read preoperative MR and CT data. The various stereoscopic display modalities, such as "cut plane visualization" and "interactive stereoscopic tool guidance" are controlled by a pointer, a surgical tool or an ultrasound probe. Interactive stereoscopy was tested in clinical feasibility case studies for planning and guidance of surgery procedures. RESULTS: By orientating the stereoscopic projections in accordance to the position of the patient on the operating table, it is easier to interpret complex 3D anatomy and to directly take advantage of this 3D information for planning and surgical guidance. In the clinical case studies, we experienced that the probe-controlled cut plane visualization was promising during tumor resection. By combining 2D and 3D display, interpretation of both detailed and geometric information may be achieved simultaneously. The possibilities of interactively guiding tools in a stereoscopic scene seemed to be a promising functionality for use during vascular surgery, due to specific location of certain vessels. CONCLUSION: Interactive stereoscopic visualization improves perception and enhances the ability to understand complex 3D anatomy. The practical benefit of 3D display is increased considerably when integrated with surgical navigation systems, since the orientation of the stereoscopic projection corresponds to the orientation of the patient on the operating table. Stereoscopic visualizations work well on MR and CT images, although volume rendering techniques are especially suitable for intraoperative 3D ultrasound image data.
We introduce a new wavelet-based method for edge detection in ultrasound (US) images. Each beam that is analyzed is first transformed into the wavelet domain using the continuous wavelet transform (CWT). Because the CWT preserves both scale and time information, it is possible to separate the signal into a number of scales. The edge is localized by first determining the scale at which the power spectrum, based on the wavelet transform, has its maximum value. Next, at this scale we find the position of the peak for the squared CWT. This method does not depend on any threshold, after the range of scales have been determined. We suggest a range of scales for US images in general. Sample edge detections are demonstrated in US images of straight and jagged edges of simple structures submerged in water bath, and of an abdominal aorta aneurysm phantom.
Observed medical ultrasound images are degraded representations of the true acoustic tissue reflectance. The degradation is due to blur and speckle and significantly reduces the diagnostic value of the images. To remove both blur and speckle, we have developed a new statistical model for diffuse scattering in 2-D ultrasound radio frequency images, incorporating both spatial smoothness constraints and a physical model for diffuse scattering. The modeling approach is Bayesian in nature, and we use Markov chain Monte Carlo methods to obtain the restorations. The results from restorations of some real and simulated radio frequency ultrasound images are presented and compared with results produced by Wiener filtering.
Observed ultrasound images are degraded representations of the-true tissue reflectance. The specular reflections at boundaries between regions of different tissue types are blurred, and the diffuse scattering within homogenous regions causes speckle because of the oscillating nature of the transmitted pulse. To reduce both blur and speckle, we have developed algorithms for the restoration of simulated and real ultrasound images based on Markov random field models and Bayesian statistical methods. The algorithm is summarized here, although a more detailed description can be found in our companion paper [1]. Because the point spread function (psf) is unknown, we investigate the effects of using incorrect frequencies and sizes for the model psf during the restoration process. First, we degrade the images either with a known simulated psf or a measured psf. Then, we use different psf shapes during restoration to study the robustness of the method. We found that small variations in the parameters characterizing the psf, less than +/- 25% change in frequency, width, or length, still yielded satisfactory results. When altering the psf more than this, the restorations were not acceptable. The restorations were particularly sensitive to large increases in the restoring psf frequency. Thus, 2-D Bayesian restoration using a fixed psf may yield acceptable results as long as the true variant psfs have not varied too much during imaging.
Initial in vivo and in vitro experiments were performed to evaluate the feasibility of stereoscopically displaying three-dimensional (3D) ultrasound data from neurosurgery, laparoscopic surgery, and vascular surgery. Stereoscopic visualization was illustrated by four video sequences, which can be downloaded from http://www.us.unimed. sintef.no/. These sequences show a brain tumor, hepatic arteries in relation to the gallbladder, a model that mimics a neuroendoscope in a cyst, and a "flight" into model of an artery with an intima flap. The experiments indicate that stereoscopic display of ultrasound data is feasible when there is sufficient contrast between the objects of interest and the surrounding tissue. True 3D vision improves perception, thus enhancing the ability to understand complex anatomic structures such as irregular lesions and tortuous vessels.
OBJECTIVE: We have integrated a neuronavigation system into an ultrasound scanner and developed a single-rack system that enables the surgeon to perform frameless and armless stereotactic neuronavigation using intraoperative three-dimensional ultrasound data as well as preoperative magnetic resonance or computed tomographic images. The purpose of this article is to describe our two-rack prototype and present the results of our work on image quality enhancement. DESCRIPTION OF INSTRUMENTATION: The system consists of a high-end ultrasound scanner, a modest-cost computer, and an optical positioning/digitizer system. Special technical and clinical efforts have been made to achieve high image quality. A special interface between the ultrasound instrument and the navigation computer ensures rapid transfer of digital three-dimensional data with no loss of image quality. OPERATIVE TECHNIQUE: The positioning system tracks the position and orientation of the patient, the ultrasound probe, the pointer, and various surgical instruments. This makes it possible to update the three-dimensional map during surgery and navigate by ultrasound data in a similar manner as with magnetic resonance data. METHODS: The two-rack prototype has been used for clinical testing since November 1997 at the University Hospital in Trondheim. EXPERIENCE AND RESULTS: The image quality improvements have enabled us, in most cases, to extract information from ultrasound with clinical value similar to that of preoperative magnetic resonance imaging. The overall clinical accuracy of the ultrasound-based navigation system is expected to be comparable to or better than that of a magnetic resonance imaging-based system. CONCLUSION: The SonoWand system enables neuronavigation through direct use of intraoperative three-dimensional ultrasound. Further research will be necessary to explore the potential clinical value and the limitations of this technology.
Based on a review of 166 references for diffusion and solubility coefficients in biological fluids and tissues, we have tabulated experimental values for the gases Ar, CO2, H2, He, N2, Ne, N2O, O2, and SF6. Two major conclusions can be drawn: a) for tissues, there is a scarcity of available data; and b) in general, there are significant differences between values determined by different investigators, the discrepancies being most prominent for diffusion coefficients. For water, we give numeric values of the temperature coefficients and preferred diffusion and solubility coefficients at 25 degrees and 37 degrees C. Further, we describe several methods for estimation of coefficients where experimental data are lacking. For tissues, none of the formulas described give precise predictions for all gases, but rough estimates sufficient for most qualitative work can almost always be found. In particular, the data material indicates that for all tissues other than fatty tissues consisting of mainly triacylglycerols, the solubility coefficients for water may be used as a good approximation. Except for SF6, the error in this approximation probably does not exceed 20%. In contrast, diffusion coefficients for most tissues are from 25 to 50% lower than the respective coefficients in water, generally increasing with the water content of the tissue.