Search PubMed⌕ Search

Biomedical subjects

T Kido

Publications and source records attributed to T Kido.

263 records · Page 15Linked to original sources

Recent progress in the development of Terumo implantable left ventricular assist system.

The research group of the Terumo Corporation, the NTN Corporation, and Setsunan University (T. Akamatsu) has been developing an implantable left ventricular assist system (ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The impeller of the MSCP is suspended by a magnetic bearing, providing contact-free rotation of the impeller inside the pump housing. Thus the MSCP is expected to provide years of long-term durability. Ex vivo chronic sheep experiments using the extracorporeal model (Model I) demonstrated long-term durability, nonthrombogenicity, and a low hemolysis rate (plasma free Hb <6 mg/dl) for more than 2 years. The prototype implantable model (Model II; 196 ml, 400 g) was evaluated ex vivo in 2 sheep and intrathoracically implanted in a small sheep (45 kg). These experiments were terminated at 70, 79, and 17 days, respectively, because of blood leakage through the connector system within the housing of Model II. There was no thrombus formation on the retrieved pump surfaces. A new connector system was introduced to the Model II pump (modified Model II), and the pump was intrathoracically implanted in a sheep. Pump flow rate was maintained at 3-7 L/min at 1700-1800 rpm. The temperature elevation on the surfaces of the motor and the electromagnet inside the pump casing was kept less than 6 degrees C. The temperature of the tissue adjacent to the pump casing became normal 10 days postoperatively. The sheep survived for more than 5 months without any sign of mechanical failure or thromboembolic complication. In vitro real-time endurance tests of motor bearings made of stainless steel and silicone nitride have been conducted for more than 1 year without any sign of bearing wear. The next prototype system (Model III), with an implantable controller and a new MSCP with reduced input power, has been developed with a view toward a totally implantable LVAS.

Alanine Transaminase↗

Terumo implantable left ventricular assist system: results of long-term animal study.

The research group of Terumo Corporation, NTN Corporation, and the Setsunan University have been developing an implantable left ventricular assist system (T-ILVAS) featuring a centrifugal blood pump with a magnetically suspended impeller (MSCP). The present study describes results of chronic animal experiments using the MSCP. The MSCP has been tested ex vivo and in vivo in 6 sheep as a left heart bypass between the left ventricular apex and descending aorta. Ex vivo chronic sheep experiments using Model I demonstrated long-term durability, nonthrombogenicity, low hemolysis (<6 mg/dl), and excellent stability of the magnetic bearing with long-term survival for up to 864 days. Average pump flow rate was 4 L/min at a fixed rotational speed of 2000 rpm. Power spectral analyses of heart rate, aortic pressure, and blood temperature maintained normal 1/f fluctuation during the study. The retrieved pump was completely free from thrombus formation and there was no evidence of infarct in major organs. The implantable Model II was evaluated ex vivo in two sheep and intra-thoracically implanted in a sheep. These experiments were terminated at 70, 79, and 17 days due to blood leakage through the connector system within the housing. No thrombus formation was observed in any of the retrieved pumps. A modified Model II with a new connector system was subsequently intra-thoracically implanted in a sheep. The sheep survived for 482 days without any sign of thromboembolic complication or hemolysis at a fixed rotational speed of 1700 rpm and an average pump flow rate of 5 L/min. There was no intra-device thrombus formation or infarct in major organs. The Model III system, consisting of an implantable controller and a new MSCP with a reduced input power of 13 W, has been developed and implanted in a chronic sheep model. The MSCP was implanted in the left pleural space and the controller in the abdominal wall. The experiment is still in progress for more than 30 days without any significant complication to date. These animal studies strongly suggest the feasibility of the MSCP for use as long-term circulatory assist.

Animals↗

Improved blood compatibility of DLC coated polymeric material.

There is currently an increasing interest in the use of DLC (diamond like carbon) films in biomedical applications. These investigations making use of DLC in the biomedical area indicate its attractive properties. In this study, we succeeded in depositing DLC on polymer substrates and found the best conditions and method for this application. We evaluated the blood compatibility of polycarbonate substrates coated by DLC (PC-DLC) under different conditions by using epifluorescent video microscopy (EVM) combined with a parallel plate flow chamber. Segmented polyurethane (SPU), which has been used to fabricate medical devices including an artificial heart, and proven to have acceptable blood compatibility, was compared with polycarbonate substrates coated with DLC film. The EVM system measured platelet adhesion on the surface of the DLC, by using whole human blood containing Mepacrine labeled platelets perfuse at a wall shear rate of 100 s(-1) at 1 min intervals for a period of 20 min. PC-DLC demonstrated that Tecoflex showed higher complement activation than PC-DLC. There were significant differences between the PC-DLC substrates. On the basis of these results, it is recommended for use as a coating material in implantable blood contacting devices such as artificial hearts, pacemakers, and other devices. This DLC seems to be a promising candidate for biomaterials applications and merits further investigation.

Carbon↗

Chemical shift GRE MRI of renal angiomyolipoma.

The renal angiomyolipoma is a fairly common benign renal tumor composed of various proportions of smooth muscle, blood vessels, and fat. Because fat is present in virtually every case, the CT findings in angiomyolipomas are so distinctive that a histologic diagnosis may be suggested. In angiomyomas composed mainly of vascular tissue and muscle or in those in which recent hemorrhage has occurred, the majority of tumors may have soft tissue CT density values without apparent fatty component (1,2). In such cases, preoperative diagnosis is extremely difficult. In this case report, we detected a small amount of fatty tissue with a chemical shift GRE MRI technique, although CT failed to detect the fatty tissue.

Aged↗

Which is more useful, the "full can test" or the "empty can test," in detecting the torn supraspinatus tendon?

The purpose of this study was to determine the clinical usefulness of the full can and empty can tests for determining the presence of a torn supraspinatus tendon. The two tests were performed in 143 shoulders of 136 consecutive patients. In each test, the muscle strength was determined by manual muscle testing, and the presence of pain during the maneuver was recorded. We interpreted the tests as positive when there was 1) pain, 2) muscle weakness, or 3) pain or muscle weakness or both. Shoulders were examined by high-resolution magnetic resonance imaging with 95% accuracy for full-thickness rotator cuff tears. There were 35 shoulders with full-thickness tears of the supraspinatus tendon. The accuracy of the tests was the greatest when muscle weakness was interpreted as indicating a torn supraspinatus tendon in both the full can test (75% accurate) and the empty can test (70% accurate). However, there was no significant difference between the accuracy of the tests when this criterion was used. Pain was observed in 62 shoulders (43%) during the full can test and in 71 shoulders (50%) during the empty can test, but the difference was not statistically significant. Muscle weakness should be interpreted as indicative of supraspinatus tendon tear. Using this indicator, both tests are equivalent in terms of accuracy, but considering pain provocation, the full can test may be more beneficial in the clinical setting.

Adolescent↗

Infective endocarditis of the tricuspid valve in a non-drug user.

A case of infective endocarditis of the tricuspid valve is described in a young female patient with no history of intravenous drug abuse. The patient suffered from symptoms of septic emboli of the lung and right heart failure. She was ultimately treated by tricuspid valve replacement. There was no recurrence of symptoms following surgery.

Adult↗

The protective effect of hochu-ekki-to (TJ-41), a Japanese herbal medicine, against HSV-1 infection in mitomycin C-treated mice.

BACKGROUND: Immmunosuppression and infectious disease in cancer patients receiving chemotherapy is a serious problem. Immunopotentiating drugs may show a therapeutic efficacy. MATERIALS AND METHODS: The protective effect of Hochu-ekki-to (TJ-41), a Japanese traditional herbal medicine, on mitomycin C (MMC)-induced immunosuppression has been investigated. Spleen weight, the number of forming colonies of granulocytes and macrophages (CFU-GM) in the bone-marrow cells, natural killer (NK) activity in splenocytes and susceptibility to lethal herpes simplex virus type-1 (HSV-1) infection were evaluated. RESULTS: Oral administration of TJ-41 (2000 mg/kg/day) restored MMC-induced decline of spleen weight. CFU-GM and NK activity (20.6% to 68.4%, 48.8% to 77.7%, 21.1% to 95.1%, respectively). Moreover, MMC treatment resulted in a lethal HSV-1 infection and TJ-41 showed a preventive effect. CONCLUSION: TJ-41 may be beneficial for the treatment of infectious diseases in immunocompromised patients receiving chemotherapeutic drugs.

Animals↗

A new amphiphilic block co-polymer with improved elastomeric properties for application in various medical devices.

The authors have demonstrated that an amphiphilic block co-polymer composed of 2-hydroxyethyl methacrylate (HEMA) and styrene (HEMA-st) showed excellent blood compatibility in in vitro, ex vivo, and in vivo experiments. The poor elastomeric properties of HEMA-st, however, have been an obstacle to its wider application in medical devices. To improve the mechanical properties of HEMA-st, the authors have developed a new amphiphilic block co-polymer composed of HEMA and octylstyrene (HEMA-oct). The size and morphology of the microdomain structures of HEMA-oct observed by transmission electron microscopy were similar to those of HEMA-st. Kink resistance tests showed improved elastomeric properties of HEMA-oct over HEMA-st. The blood compatibility of HEMA-oct was evaluated using an in vitro flow cell system combined with an epifluorescent video microscope, in which real time platelet adhesion and activation in whole blood can be observed and quantified, and ex vivo rabbit A-A shunt experiments. HEMA-st and a polyurethane (Pellethane 2363-80AE) were used for comparison. In a flow cell system, both HEMA-st and HEMA-oct showed minimal platelet coverage on the surfaces and less platelet activation as measured by beta-thromboglobulin (beta-TG), whereas Pellethane showed a considerable amount of platelet coverage with high beta-TG production. A-A shunt occlusion times were 309 +/- 31.2 min for HEMA-st, 251 +/- 47.7 min for HEMA-oct, and 30 +/- 3.4 min for Pellethane.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparative blood compatibility of polyether vs polycarbonate urethanes by epifluorescent video microscopy.

The segmented polyether urethanes (PEUs) have been used in implantable medical devices due to excellent mechanical properties, acceptable blood compatibility, and good biostability. However, recent studies demonstrate that the polyether soft segment of PEU is susceptible to oxidative degradation in vivo due to scission of the polyether group. Recently, polycarbonate urethanes (PCUs) having no ether linkage in the soft segment have been developed, and show improved stability against oxidative degradation over PEUs. The current study evaluates blood compatibility of these PCUs in comparison with PEUs using epifluorescent video microscopy (EVM) combined with a parallel plate flow cell. The authors selected two PCUs, Corethane 80A (Corvita Corporation, Miami, FL) and PCU(1560), and two PEUs, Pellethene 2363-80AE (Dow Chemical Japan, Tokyo, Japan) and Tecoflex EG80A (Thermedics, Inc., Woburn, MA), all of which have similar hard segment compositions (MDI or HMDI:1,4-butanediol(BD)) and the same hardness of 80A. The EVM measured the amount of platelet coverage on the surfaces using human whole blood perfused at a wall shear rate of 100/sec for 20 min. Complement activation (C3a) also was measured. Both PEUs, especially Pellethane, showed significantly higher platelet adhesion than the PCUs (p < 0.05). There were no significant differences in platelet adhesion between the two PCUs. As for C3a measurements, Tecoflex showed higher complement activation than the others. Based on these results, it is recommended that PEUs should be replaced by ether free PCUs for use in implantable blood contacting devices such as artificial hearts and pacemaker lead insulators.

Biocompatible Materials↗

More than 1 year continuous operation of a centrifugal pump with a magnetically suspended impeller.

The authors have been developing a centrifugal pump with a magnetically suspended impeller (MSCP) designed for total artificial heart and long-term ventricular support. The MSCP consists of a magnetic bearing, an impeller and housing, and a driving motor. The impeller is suspended by a magnetic bearing, therefore providing contact free rotation of the impeller inside the pump. This study was designed to evaluate long-term durability and nonthrombogenicity of the MSCP in a chronic sheep model. The blood contacting surfaces of the pump and conduits were completely modified by a heparin immobilization technique (Hepaface). The MSCP was placed paracorporeally as a left heart bypass between left ventricle and descending aorta in three adult sheep. Coumadin was given orally to maintain prothrombin time at 15-20 sec. The coagulation and hematologic parameters, including plasma free hemoglobin, were periodically monitored throughout the experiment. Under daily movement in the cage, the pump could produce average flow rates of 3-6 L/min (50-100 ml/kg) at 1,700-2,000 rpm. Although the arterial pulse contour decreased, there was no physiologic deterioration. The axial impeller excursion monitored by a position sensor was < 25 microns. Plasma free hemoglobin level remained at < 5 mg/dl throughout the experiment. There was no increase in the motor current, which indicates no massive thrombus formation around the impeller. One experiment was terminated at 70 days due to Hall sensor dysfunction of the motor. The retrieved pump was entirely free from thrombus formation. There was no detectable thrombus formation inside the pump or the inflow and outflow conduits. Hematologic, renal, and hepatic parameters remained within the normal range throughout the experiment. The other two sheep have survived for more than 395 and 41 days without major complication. These studies demonstrated that the MSCP has significant potential for long-term use.

Animals↗