Search PubMed⌕ Search

Biomedical subjects

T K Narayan

Publications and source records attributed to T K Narayan.

4 recordsLinked to original sources

Prediction of human observer performance by numerical observers: an experimental study.

Numerical observers are investigated for predicting the outcome of a free-response human observer study involving the detection of simulated pulmonary nodules in images reconstructed from low-dose computed tomography projection data by use of several reconstruction algorithms. A new way of calculating the figure of merit of a numerical observer is proposed wherein the detectability of signals in a particular image depends on the noise properties associated with that image and not the other images in the data set. The resulting variants of numerical observers are found to perform better than their traditional counterparts. In particular, the imagewise variant of the region-of-interest observer is found to predict best the rank ordering of algorithms by human observers for the free-response task.

Algorithms↗

A methodology for testing for statistically significant differences between fully 3D PET reconstruction algorithms.

We present a practical methodology for evaluating 3D PET reconstruction methods. It includes generation of random samples from a statistically described ensemble of 3D images resembling those to which PET would be applied in a medical situation, generation of corresponding projection data with noise and detector point spread function simulating those of a 3D PET scanner, assignment of figures of merit appropriate for the intended medical applications, optimization of the reconstruction algorithms on a training set of data, and statistical testing of the validity of hypotheses that say that two reconstruction algorithms perform equally well (from the point of view of a particular figure of merit) as compared to the alternative hypotheses that say that one of the algorithms outperforms the other. Although the methodology was developed with the 3D PET in mind, it can be used, with minor changes, for other 3D data collection methods, such as fully 3D cr or SPECT.

Algorithms↗

Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithms.

The relative performance of five fully 3D PET reconstruction algorithms is evaluated. The algorithms are a filtered backprojection (FBP) method and two variants each of the EM-ML and ART iterative methods. For each of the iterative methods, one variant makes use of voxels and the other makes use of 'blobs' (spherically symmetric functions smoothly decaying to zero at their boundaries) as basis functions in its discrete reconstruction model. The methods are evaluated from the point of view of the efficacy of the reconstructions produced by them for three typical medical tasks--estimation of the average activity inside specific regions of interest, detection of hot spots, and detection of cold spots. A free parameter is allowed in the description of each of the five algorithms; the parameters are determined by a training process during which a value of the free parameter is selected which (nearly) maximizes a technical figure of merit. Such training and the actual comparative evaluation is done by making use of randomly generated phantoms and their projection data. The methodology allows assignation of levels of statistical significance to claims of the relative superiority of one algorithm over another for a particular task. We find that using blobs as basis functions in the iterative algorithms is definitely advantageous over using voxels. This result has high statistical significance. (We also include a visual illustration of it.) Comparing FBP, EM-ML using blobs, and ART using blobs, we do not find a clear difference in the overall performance of the investigated variants of the methods. If anything, our results suggest that ART using blobs may be the most efficacious of the three.

Algorithms↗