Arteriovenous malformation hemodynamics: a transcranial Doppler study.

Congenital arteriovenous malformation (AVM) of the brain represents a defect in capillary development resulting in a high flow fistula between arterial and venous systems. In this study, AVM hemodynamics were related with clinical findings. Volume flow was calculated based on transcranial Doppler (TCD) and angiographic data. Forty patients admitted to the Massachusetts General Hospital for proton beam therapy (33 +/- 10 yr old; mean +/- SD) were studied. Four symptoms were considered: intracranial bleeding, progressive neurological deficit, seizures, and headache. Fourteen control subjects aged 30 +/- 7 years (mean +/- SD) were normal volunteers. Angiography with calibrated markers permitting magnification correction was available for all patients. Lateral and medial depth limits of the intracranial basal arteries in relation to the TCD temporal window were determined by TCD and angiogram with excellent correlation. Selected depth for data acquisition was determined independently in the angiogram and by TCD. The difference between the two techniques was less than 4 mm. Mean flow velocity, pulsatility index, and vessel diameter were studied. Flow volume was calculated from these data. Mean flow velocity, pulsatility index, vessel diameter, and flow volume were significantly different among AVM feeders, non-feeders, and control arteries. The non-feeding middle cerebral artery, anterior cerebral artery, and posterior cerebral artery flows were 254 +/- 13, 136 +/- 14, and 79 +/- 8 ml/min, respectively. Accordingly, the estimated cerebral flow volume was 938 ml/min. The feeding middle cerebral artery, anterior cerebral artery, and posterior cerebral artery flows were 552 +/- 47, 369 +/- 70, and 484 +/- 67 ml/min, respectively (P < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.

OBJECTIVE: The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS: The pulse sequence was optimized at 1.5 T with a healthy volunteer. Various scanning parameters were evaluated, and liver-spleen signal difference/noise measurements were used to estimate lesion contrast-to-noise ratios. We examined 24 patients with hepatic masses using the optimized sequence with spin-echo T1-weighted and T2-weighted imaging as well as unenhanced and gadopentetate dimeglumine-enhanced FMPSPGR imaging. The contrast-to-noise ratio for the hepatic tumors was determined for each sequence. Three radiologists who did not know the biopsy or test results reviewed all images for lesion conspicuity, lesion tissue specificity, and overall image quality. RESULTS: A comparison of unenhanced FMPSPGR images with spin-echo T1-weighted images showed a 40% improvement in mean contrast-to-noise ratio and a 70% improvement in liver signal-to-noise ratio for the FMPSPGR images. A comparison of gadopentetate dimeglumine-enhanced FMPSPGR images with spin-echo T1- and T2-weighted images showed a superior contrast-to-noise ratio for the enhanced FMPSPGR images in 17 (68%) of 25 hepatic lesions, which included all hepatic cysts (n = 3) and all hepatomas (n = 6), and in six of 12 patients with other liver tumors. The results of contrast-to-noise ratio for four patients with hemangiomas were mixed. For the remaining eight lesions, the contrast-to-noise ratio for spin-echo T1- and T2-weighted images predominated in three and five cases, respectively. Contrast-enhanced FMPSPGR images revealed a 40% and 300% increase in contrast-to-noise ratio compared with T2- and T1-weighted images, respectively. All three radiologists preferred the contrast-enhanced FMPSPGR images for overall image quality. For lesion conspicuity and specificity, however, the three radiologists differed, with a preference for the FMPSPGR images in 52%, 80%, and 40% of cases for lesion conspicuity and in 68%, 40%, and 60% of cases for lesion specificity. CONCLUSION: FMPSPGR is a new, ultrafast MR sequence that provides T1-weighted images of the liver during suspended respiration. Contrast-to-noise ratio and liver signal-to-noise ratio are significantly improved over those on conventional spin-echo T1-weighted images. The combination of breath-hold FMPSPGR with gadopentetate dimeglumine is an excellent technique that can be used to rapidly evaluate the liver with superior overall image quality. Contrast-to-noise ratios are generally superior to T2-weighted spin-echo images, making this technique a useful adjunct to conventional spin-echo MR imaging.

Adult↗

Reduction of RF penetration effects in high field imaging.

A method of correcting for the RF inhomogeneity in the body by dielectric loading of the coil-to-shield space in an RF resonator (coil and shield assembly) is described. The presence of the RF coil and RF shield have significant effects on RF homogeneity. Based on theoretical calculations, a method for adjusting the RF homogeneity by manipulating the axial propagation constant, kappa z, is proposed. This is accomplished by loading the coil-to-shield space with dielectric material of suitable relative permittivity so as to increase kappa z and decrease the radial propagation constant, kappa rho. In this manner, the radial wavelength (lambda rho = 2 pi/kappa rho) can be increased relative to the body dimensions, and the field amplitude variations in the axial plane minimized. Theoretical calculations indicate that a value of between 30 and 40 for the relative permittivity of the dielectric material in the coil-to-shield space would reduce the RF field inhomogeneity from +/- 15% to about +/- 3% over a central 30-cm-diameter region of a homogeneous 40-cm-diameter body at both 64 and 170 MHz. The theoretical model was verified in laboratory measurements of the [formula; see text] field generated in a test coil at 170 MHz which was scaled to correspond to a body at 64 MHz. However, the improved RF field homogeneity would be accompanied by increased RF power requirements and reduced coil sensitivity.

Humans↗

Thick-section, single breath-hold magnetic resonance pulmonary angiography.

RATIONALE AND OBJECTIVES: Approaches to performing magnetic resonance angiography (MRA) of the pulmonary vasculature are described using very fast (repetition time [TR] less than 13 mseconds) radiofrequency (rf)-spoiled, gradient-recalled pulse sequences and the standard quadrature body imaging coil of a commercial 1.5-T MR imaging system. METHODS AND RESULTS: Signal-to-noise (SNR) is improved by signal averaging (Nex greater than or equal to 4) in a two-dimensional, single thick-section approach and by volume acquisition (Nex = 1) in a three-dimensional approach. Blood signal loss is minimized by using short, asymmetric echoes (echo time [TE] less than or equal to 2.7 mseconds). Respiratory motion is eliminated by keeping the scan time short enough (approximately 15 seconds) for image acquisition within a single breath-hold. Cardiac motion artifacts are reduced with section orientations that avoid intersecting the heart and/or use of small flip angle (alpha less than or equal to 25 degrees). CONCLUSIONS: Images of healthy volunteers showed that while single thick sections have superior SNR, the three-dimensional approach appears to produce better visualization of the peripheral vascular segments and offers improved ability to process the images to remove overlapping structures.

Adult↗

High-resolution MR imaging of the wrist and eye with short TR, short TE, and partial-echo acquisition.

High-resolution spin-echo and two- and three-dimensional gradient-recalled acquisition in the steady state (GRASS) and spoiled GRASS images of the wrist and eye were obtained with a whole-body magnetic resonance imager by using trapezoidal phase-encoding gradient waveforms and by lowering receiver bandwidth to +/- 8 kHz, which results in a minimum field of view (FOV) of 4 cm and pixel resolution of 156 microns for a 256 x 256 matrix. Short echo times were achieved by using partial-echo acquisition. Poor signal-to-noise ratio resulting from smaller voxel sizes was overcome by using prototype receive-only eye and wrist coils. Images were obtained in reduced time and were superior to those obtained in studies performed with an 8-12-cm FOV and commercially available coils.

Adult↗

Pulmonary vasculature: single breath-hold MR imaging with phased-array coils.

The authors obtained magnetic resonance images of the pulmonary vasculature with reduced artifacts caused by cardiac and respiratory motion by acquiring a series of moderately thin sections in a single breath-hold with an ultrafast gradient-echo pulse sequence. The series of two-dimensional images was postprocessed with a maximum-intensity projection algorithm. Time-of-flight inflow enhancement increased the signal intensity of arteries and veins while radiofrequency phase spoiling produced limited stationary spin suppression of the chest wall. Moderately thin (8-mm) section thicknesses were used to attain the resolution necessary to visualize smaller pulmonary vascular segments up to the chest wall while the number of acquired sections was minimized. Because the body coil did not provide an adequate signal-to-noise ratio (S/N) for a single excitation and thin-section acquisitions, phased-array coils covering either the right or left lung were used to single breath-holds prevented the misregistration and blurring that occurred in examinations performed with multiple breath-holds.

Humans↗

Kinematic MR imaging of the patellofemoral joint: comparison of passive positioning and active movement techniques.

Thirteen patients underwent magnetic resonance (MR) imaging of the patellofemoral joint in an evaluation of passive positioning and active movement kinematic MR imaging techniques. Sixteen joints were symptomatic, and 10 were not. Delineation of normal and abnormal patellar alignment and tracking was similar with the two techniques, but kinematic MR imaging performed with active movement allowed a substantial reduction in examination time while permitting evaluation of the contribution of associated activated muscles and soft-tissue structures to patellofemoral joint function.

Adolescent↗

Occlusion and narrowing of the pharyngeal airway in obstructive sleep apnea: evaluation by ultrafast spoiled GRASS MR imaging.

Morphologic abnormalities of the pharyngeal airway are frequently found in patients with obstructive sleep apnea. These structural alterations in the pharyngeal airway can be detected in awake patients by using rapid imaging techniques. Ten patients with clinically proved obstructive sleep apnea had ultrafast spoiled gradient-recalled acquisition in the steady state (GRASS) MR imaging of the pharyngeal airway to determine the presence of occlusions and/or narrowings. Twelve sequential images were obtained at one midsagittal plane and at eight transverse planes through the pharyngeal airway. The scans were obtained at the rate of one image per 1.04 sec while the patient was breathing quietly. Occlusions or narrowings of the pharyngeal airways were detected on MR images in all patients. The site(s) of the occlusions and the site(s) and extent of the narrowings varied. Six patients had occlusions and four had narrowings of one or more sites. This study shows that ultrafast spoiled GRASS MR imaging can be used to evaluate patients with obstructive sleep apnea during tidal breathing and is useful for determining the presence of occlusions and narrowings of the pharyngeal airway.

Adult↗

Lung calcium-dependent phospholipid-binding proteins: structure and function.

Distinct peptide maps of two rabbit lung Ca2(+)-dependent phospholipid-binding proteins (PLBPs), 36,000 and 33,000, were generated by cyanogen bromide (CNBr) cleavage, trypsin or Staphylococcus aureus V8 proteinase digestion. The amino acid sequence of a CNBr-cleaved peptide of the 36,000 PLBP was aligned to the amino terminus of human lipocortin I with more than 77% identity, but had no identity with the known amino terminal sequence of other known annexins. Partial amino acid sequence of a 33,000 PLBP peptide demonstrated a close (56%) relationship to endonexin II, human placental anticoagulant protein, and porcine intestine protein II, but shared only 32% identity with lipocortin I, 30% with lipocortin II. Antiserum generated against purified 36,000 PLBP reacted strongly with the 33,000 PLBP, but did not react with any other rabbit lung cytosolic proteins. Both PLBPs inhibited the phospholipase A2 reaction when dioleoyl phosphatidylcholine and phosphatidylglycerol vesicles or monolayers were used as substrates. In the vesicle assay, the phospholipase A2 reaction was inhibited at lower substrate phospholipid concentrations but not at nearly saturating substrate concentrations. In the monolayer assay, the phospholipid-binding proteins did not inhibit phospholipase A2 at a low phospholipid surface concentration of 3.8.10(-3) molecules/A2, but they did at higher surface concentrations between 1.1 x 10(-2) and 3.8 x 10(-2) molecules/A2. The inhibition of phospholipase A2 by rabbit lung phospholipid-binding proteins is most likely due to the prevention of penetration by phospholipase A2 into the interface, a requirement for the enzyme to act on the substrate.

Amino Acid Sequence↗

An analytical model for the design of RF resonators for MR body imaging.

A closed form, analytical solution describing the RF fields generated by an RF body coil resonator for MR imaging at 1.5 and 4.0 T is presented. This solution extends the results of earlier studies of RF penetration in the body by explicitly including the RF coil, the RF shield, and the field variation along the z axis for high-pass bird cage coils. A salient feature of this treatment is the calculation of the axial propagation constant, kz, which determines the z dependence of the RF field. We have determined the relative power deposition in the body, the B1 field homogeneity, and coil losses, which are functions of the coil-to-shield separation and body size. The relative power deposition in the body has been calculated to vary as the 1.58 power of the body radius. The calculations have also predicted that the field homogeneity in the z direction exhibits greater degradation at higher frequencies in a high-pass coil than in a low-pass coil. The model predicts an increase in coil losses by a factor of 2.8 as the coil-to-shield separation is reduced from 5 to 2 cm in a standard body resonator. Although the results for only a homogeneous cylindrical object or body are presented, the theory can be extended to a multilayered heterogeneous object of varying permittivity and conductivity.

Body Constitution↗

Patellofemoral joint: evaluation during active flexion with ultrafast spoiled GRASS MR imaging.

An ultrafast spoiled gradient-recalled acquisition in the steady state pulse sequence was developed that permits multiple images to be obtained at a temporal resolution suitable for examining the patellofemoral joint during active flexion. This pulse sequence was used to perform kinematic magnetic resonance imaging of patellar alignment and tracking in five healthy subjects and seven patients with a provisional clinical diagnosis of abnormal patellofemoral joints.

Female↗

The use of a multichannel scaling method to detect radioactive species in spread monolayers.

This study describes a simple and inexpensive method for monitoring radioactive species spread as monolayers at the air/water interface. The combination of a discriminator and multichannel scalar counter with a personal computer functions to unify all measurements, to simplify the operational process and data acquisition, and to provide a real-time display of the data. Its use is demonstrated by following the hydrolysis of L-alpha-[1-14C]dioleoyl phosphatidylcholine by the enzyme, phospholipase A2, isolated from the porcine pancreas.

Animals↗

Projection flow imaging by bolus tracking using stimulated echoes.

Previous investigators have employed the concept of bolus tracking using either spin echoes or gradient echoes. In this paper we introduce two methods of bolus tracking using planar- and volume-selective stimulated echoes. The planar method employs a selective 90 degrees rf pulse which tags all spins in a particular plane. At a time tau 1 later, a nonselective 90 degrees rf pulse is employed, followed after a time tau 2, by another nonselective rf pulse. Only spins which experience all three rf pulses form a stimulated echo at time tau 1 after the third rf pulse. A balanced pair of flow-compensated dephasing (crusher) gradients further ensures that the stimulated echo is due only to the effect of all three rf pulses while minimizing flow dephasing. The first part of this gradient pair is applied after the initial rf pulse in the first tau 1 period to dephase the tagged spins. The second part of this gradient pair is applied after the third rf pulse to rephase the spins. Since the plane of the excited slice is orthogonal to the readout direction, flowing spins are imaged in an angiographic manner as they move away from the excited slice. A modification to this basic sequence excites only a small volume. In this manner, the suppression of stationary spins is effected by volume-selective excitation. In both the planar- and the volume-selective techniques, the excited spins undergo T1 and T2 relaxation during the tau 1 period but only T1 relaxation in the tau 2 period. In blood, where T1 is much greater than T2, keeping tau 1 as short as possible minimizes signal loss due to T2 dephasing. These methods demonstrate increased sensitivity compared to similar bolus tracking methods using either spin echoes or gradient echoes.

Blood Flow Velocity↗

Dynamic study of the upper airway with ultrafast spoiled GRASS MR imaging.

Dynamic magnetic resonance (MR) imaging of the upper airway was not possible previously because of poor temporal resolution. Recently, a rapid technique has been developed that provides the means to obtain multiple images at different section locations with sufficient image quality and temporal resolution to allow a comprehensive, dynamic study of the upper airway. The authors describe an ultrafast spoiled GRASS (gradient-recalled acquisition in the steady state) pulse sequence for dynamic studies of the upper airway. The authors believe that this procedure has potential for identifying and characterizing upper airway abnormalities such as nonfixed occlusions and/or narrowings that may exist in patients with obstructive sleep apnea.

Humans↗

Single-breath-hold venous or arterial flow-suppressed pulmonary vascular MR imaging with phased-array coils.

A method for acquiring pulmonary vascular magnetic resonance (MR) images with either venous or arterial flow suppression is described. The proposed method only marginally increases the overall imaging time compared with conventional flow-suppression techniques. This enables an acquisition to be completed within a single breath hold with some selectivity as to flow direction. Instead of applying a spatially selective presaturation pulse before each radio-frequency (RF) excitation pulse, the flow presaturation pulse is applied once every 16-20 RF excitation pulses. To avoid image artifacts and to maintain a steady state, each presaturation pulse interval is followed by a normal imaging segment but with data acquisition turned off. Overall imaging time is increased by two TR intervals for each presaturation segment. For a 256 x 128 matrix acquisition, venous flow presaturation increases overall imaging time by approximately 14 TR intervals, while arterial flow suppression increases imaging time by 10 TR intervals.

Aged↗

Phase-correction method for reduction of B0 instability artifacts.

View-to-view phase shifts due to B0 instability are corrected by applying a phase correction to the low-spatial-frequency views. The algorithm described herein assumes that the signal intensity in the space outside of an object represents only noise. A set of phases for the low-spatial-frequency views are calculated by minimizing, in the image, the intensity of the induced artifacts in the space outside of the object.

Algorithms↗

Techniques for high-resolution MR imaging of atherosclerotic plaque.

Atherosclerotic cardiovascular disease is the most common cause of death in the United States. Investigation of atherosclerotic plaque morphology and composition is important because the findings may be useful in predicting prognosis or response to therapy. This study presents high-resolution magnetic resonance (MR) imaging techniques developed on a 1.5-T whole-body imager with a custom-built surface coil, for characterizing the composition and morphology of plaque removed at carotid endarterectomy. The initial comparison of MR imaging and histologic results showed good correlation. In conjunction with MR angiography, these techniques could be used in in vivo imaging to define the size, location, and contents of atherosclerotic plaque at the carotid bifurcation.

Artifacts↗