Search PubMedSearch

Biomedical subjects

T K Abboud

Publications and source records attributed to T K Abboud.

At least 19 recordsLinked to original sources

Transnasal butorphanol: a new method for pain relief in post-cesarean section pain.

This study was undertaken to evaluate the efficacy and the safety of transnasal butorphanol (TNB) compared to intravenous butorphanol (IVB) in 186 patients experiencing moderate to severe post-cesarean section pain. Patients were randomly assigned to five groups in a double-blind fashion: Group I (n = 37) received 2 mg IVB, Group II (n = 38) 2 mg TNB, Group III (n = 36) 1 mg TNB followed by a repeat dose of 1 mg TNB at 60 min, Group IV (n = 38) 0.5 mg TNB followed by a repeat dose of 0.5 mg at 60 min, and Group V (n = 37) received placebo. All administrations were double dummy. Pain intensity and relief were noted and the incidence of side effects was recorded. Remedication with the same study drug was allowed up to 72 h. Onset of analgesia was more rapid in the 2 mg IV group compared to the three TN groups: 5 min vs 15 min, respectively. However, the 2 mg and the 1-1 mg TN groups had a longer duration of analgesia, approximately 4.5 h, compared to 3.0 h for the 2 mg IV group (P less than 0.05). Somnolence was dose related and was the most frequent side effect, and was less frequent when the TN dose was divided into 2 doses administered 1 h apart. Multiple doses of TNB and IVB were safe and clinically acceptable up to 3 days at all doses studied. There were no incidences of nasal mucosa irritation, or cardiovascular or respiratory depression. It is concluded that transnasal butorphanol represents a safe and effective alternative to injectable butorphanol for post-cesarean section pain and offers a better and longer duration of analgesia compared to IV butorphanol. The optimum dose seems to be 2 mg TN butorphanol and it is tolerated better when divided into 1 mg increments, given 1 h apart.

Administration, Intranasal

Prophylactic oral naltrexone with intrathecal morphine for cesarean section: effects on adverse reactions and analgesia.

The influence of two different doses of oral naltrexone on the adverse effects and the analgesia associated with intrathecal morphine was compared in a double-blind, placebo-controlled study. Thirty-five patients undergoing cesarean section were provided postoperative analgesia by 0.25 mg intrathecal morphine. Sixty minutes later they were given 6 mg naltrexone, 3 mg naltrexone, or placebo as an oral solution. Pain relief was assessed by the Visual Analog Scale. Requirements for additional analgesics and side effects were recorded. Duration of analgesia was shorter in the 3- and 6-mg naltrexone groups than in the placebo group, 10.0 +/- 2.6, 12.4 +/- 2.6, and 19.2 +/- 4.5 h (mean +/- SEM), respectively, but values did not reach statistical significance. The incidence of pruritus and vomiting was significantly less in the 6-mg naltrexone group than in the other two groups (P less than 0.05). Somnolence was significantly less in the 3- and 6-mg naltrexone groups than in the placebo group (P less than 0.05). Naltrexone (6 mg) is an effective oral prophylactic against the pruritus and vomiting associated with intrathecal morphine for analgesia after cesarean section, but it is associated with shorter duration of analgesia.

Administration, Oral

Prophylactic oral naltrexone with epidural morphine: effect on adverse reactions and ventilatory responses to carbon dioxide.

The influence of two different doses of oral naltrexone on the adverse effects and the analgesia of epidural morphine were compared in a double-blind, placebo-controlled study. Forty-five patients undergoing cesarean section were provided postoperative analgesia with 4 mg epidural morphine. Five minutes later they received 6 mg naltrexone, 9 mg naltrexone, or placebo as an oral solution. Pain relief was assessed by the Visual Analog Scale (VAS) and by direct questioning of the patients. Requirement for additional analgesics and side effects were noted. Respiratory effects of epidural morphine and naltrexone were assessed using the ventilatory responses to CO2 and by monitoring O2 saturation (Spo2) using pulse oximetry. All patients in the placebo group had adequate analgesia. One of the 15 patients who received naltrexone 6 mg had inadequate analgesia versus five of the 15 patients who received naltrexone 9 mg (P less than 0.05), 9 mg versus placebo. Ten patients (67%) in the placebo group had pruritus while no patient in the 6 mg naltrexone group and one patient in the 9 mg group experienced mild pruritus (P less than 0.05), placebo versus other two groups. The CO2 response slopes were depressed compared to control values from 6-16 h in the placebo group, from 6-12 h in the 6 mg naltrexone group. No significant depression was noted in the 9 mg naltrexone group. The authors conclude that oral naltrexone 6 mg significantly reduces the incidence of pruritus associated with epidural morphine without affecting analgesia and that 9 mg naltrexone is associated with shorter duration of analgesia than 6 mg naltrexone.

Administration, Oral

Isoflurane or halothane for cesarean section: comparative maternal and neonatal effects.

The maternal and neonatal effects of isoflurane and halothane combined with 50% N2O - 50% O2 were compared in 60 healthy parturients undergoing primary or repeat cesarean section. All patients had rapid sequence induction of anesthesia with sodium thiamylal 4 mg/kg followed by succinylcholine for tracheal intubation. Patients were randomly assigned to one of three groups of 20 each (inspired 0.5% isoflurane, 1% isoflurane or 0.5% halothane), combined with 50% N2O and O2. After delivery, 67% N2O in O2 was used, supplemented by butorphanol. Maternal blood loss did not differ significantly among the three groups and none of the patients developed intraoperative awareness. At the time of delivery, maternal plasma epinephrine levels were significantly above preinduction levels in the 0.5% isoflurane group but unchanged in the other two groups. Neonatal status as ascertained by Apgar scores, cord acid base status and the Neurologic and Adaptive Capacity Scores (NACS) was equally good in the three groups of patients. Serum inorganic fluoride concentrations in the mother after anesthesia were not significantly above preanesthetic levels in any of the groups and there was no biochemical evidence of renal toxicity. In all neonates fluoride ion concentrations in the first voided urine sample were less than 7 mumol/l, a value well below that associated with nephrotoxicity. It is concluded that isoflurane is a safe supplement to N2O - O2 mixture for cesarean section and is a safer alternative to halothane in situations when patients receiving beta-adrenergic therapy require cesarean section since halothane might potentiate arrhythmias caused by beta adrenergic agonists.

Adult

Mini-dose intrathecal morphine for the relief of post-cesarean section pain: safety, efficacy, and ventilatory responses to carbon dioxide.

To determine the safety, efficacy, and the ventilatory responses to carbon dioxide (CO2) of mini-dose intrathecal morphine, 33 healthy women who underwent cesarean section with spinal anesthesia using 0.75% bupivacaine in 8.25% dextrose were studied. Patients were randomly assigned to receive, in a double-blind fashion, either morphine 0.25 mg (group I, n = 11), morphine 0.1 mg (group II, n = 10), or saline (group III, placebo group, n = 12) in 0.5 ml volume mixed with the bupivacaine. In both groups I and II excellent postoperative analgesia with long duration was obtained (27.7 +/- 4.0 and 18.6 +/- 0.9 hours, respectively, X +/- SEM). All patients in group III required an analgesic (8 mg subcutaneous morphine) within 3 hours of spinal anesthesia. Seven patients in group I and four patients in group II developed mild pruritus that did not require treatment. Ventilatory responses to CO2 showed no evidence of depression attributable to either the 0.25 or 0.1 mg of morphine, but significant depression of the CO2 responses was observed in group III patients after administration of subcutaneous morphine. It is concluded that a dose as low as 0.1 mg of intrathecal morphine gives excellent analgesia with minimal to no side effects and that subcutaneous morphine is associated with marked depression of the ventilatory variables.

Adult

Epidural and intrathecal administration of opioids in obstetrics.

Intraspinal epidural or intrathecal injection of opiates can provide outstanding analgesia in obstetric patients. Epidural and intrathecal opiates may afford more prolonged analgesia without interference of neuromuscular function or depression of the sympathetic nervous system that can occur with other anesthetic regimens. However, certain precautions are recommended to minimize potential side effects.

Anesthesia, Epidural

Comparative maternal, fetal, and neonatal effects of chloroprocaine with and without epinephrine for epidural anesthesia in obstetrics.

The effects of epidural chloroprocaine with and without 1:200,000 epinephrine during labor and delivery on uterine activity, progress of labor, fetal heart rate, maternal blood pressure, newborn Apgar scores, neonatal acid-base status, and the Neurologic and Adaptive Capacity Scoring System (NACS) were compared in 28 parturients. Patients in group I (n = 14) received 2% chloroprocaine with 1:200,000 epinephrine and patients in group II (n = 14) received 2% plain chloroprocaine. Addition of epinephrine to chloroprocaine had no significant effects on uterine activity, duration of first or second stages of labor, or fetal heart parameters. Apgar scores, neonatal acid-base status, and the NACS were equally good in the two groups. Duration of analgesia was significantly longer in group I than in group II patients (76 +/- 3.8 vs 42.9 +/- 1 min, P less than 0.001). We conclude that addition of epinephrine to chloroprocaine during epidural anesthesia in the normal parturient has no adverse effects on mother, fetus, neonate, or the progress of labor and that it significantly prolongs the duration of anesthesia.

Acid-Base Equilibrium

Epidural butorphanol or morphine for the relief of post-cesarean section pain: ventilatory responses to carbon dioxide.

To determine the safety, efficacy, and the ventilatory responses to carbon dioxide (CO2) of epidurally administered butorphanol or morphine, 122 healthy women who underwent cesarean section with epidural anesthesia were studied. Patients were randomly assigned to receive one of four epidural regimens for the relief of postoperative pain: 5 mg morphine (n = 32), 4 mg butorphanol (n = 30), 2 mg butorphanol (n = 29), or 1 mg butorphanol (n = 31). Epidural morphine provided satisfactory analgesia with slow onset and long duration of approximately 21 hr. When butorphanol was administered, analgesia of rapid onset was seen with increasing duration and effectiveness observed with increasing dose; approximately 8 hr when using 4 mg. Sixty-two percent of the patients who received morphine had pruritus. Somnolence was the main side effect encountered in patients who received epidural butorphanol. The ventilatory response to CO2 was depressed after morphine and after 2 and 4 mg butorphanol, but the duration of depression was more prolonged after morphine. It is concluded that epidural butorphanol is effective in providing pain relief after cesarean section with minor side effects. However, patients must be observed closely because of possible respiratory depression.

Butorphanol

Neonatal responses to alphaprodine administered during labor.

The effect of intravenously administered alphaprodine on newborn Apgar scores, neonatal acid-base status, and the Neurologic and Adaptive Capacity Scoring System (NACS) were compared in 30 parturients. Patients in group 1 (n = 15) received 20-40 mg increments of alphaprodine, with a total dose of 39.3 +/- 3.7 mg (mean +/- SEM). Group 2 patients (n = 15) received no medication during labor. Apgar scores, neonatal acid-base status, and the NACS were equally good in the two groups. The concentrations of alphaprodine in maternal vein, umbilical vein, and umbilical artery at delivery were measured using a gas-chromographic mass spectrophotometric technique. The results showed an umbilical vein-to-maternal vein ratio of 0.52 +/- 0.09. It is concluded that when administered as in this study, alphaprodine has no adverse effects on the neonate.

Adult

Comparative maternal and neonatal effects of halothane and enflurane for cesarean section.

The effects of placental transfer of enflurane and halothane were studied in 81 women undergoing cesarean sections. All patients had rapid sequence induction using thiopental, succinylcholine, and endotracheal intubation. They were then randomly assigned to one of five groups: Group I (n = 16) received N2O and oxygen, Group II (n = 16) N2O, oxygen, and 0.25% halothane, Group III (n = 18) N2O, oxygen, and 0.5% halothane, Group IV (n = 18) N2O, oxygen, and 0.5% enflurane, Group V (n = 13) N2O, oxygen, and 1% enflurane. At delivery, blood was drawn from the maternal artery, umbilical vein and artery for measurement of the halogenated agents using gas chromatography. The neonates were evaluated by Apgar scores, umbilical artery and vein acid base status and the Early Neonatal Neurobehavioral Scores (ENNS) at 2 and 24 h of age. Blood loss and the incidence of maternal awareness were also determined. The umbilical vein to maternal vein ratio was approximately 0.5 and 0.6 for enflurane and halothane, respectively. The umbilical artery to umbilical vein ratio was 0.5 with both agents; higher inspired anesthetic concentrations produced higher blood levels. All neonates had Apgar scores of 8 or more at 5 min with the exception of one neonate in the N2O group. Maternal and neonatal acid base status, blood loss, and ENNS were not affected by the addition of the halogenated agents. Of the patients who had N2O alone, 12% had awareness versus none in the other groups. These data demonstrate that low dose halothane or enflurane decreases the incidence of maternal awareness and does not adversely affect the neonate.

Adult

The effects of naloxone associated with the intrathecal use of morphine in labor.

The efficacy of naloxone in reducing the incidence of side effects after intrathecal injection of morphine and the effects of maternal naloxone administration on the condition of the newborn were evaluated in 40 patients. Patients in labor were given a 1-mg intrathecal injection of morphine and, 1 hr later, either a 0.4-mg bolus of naloxone, followed by a 0.4-0.6 mg/hr intravenous infusion of naloxone, or an intravenous bolus of saline, followed by an intravenous infusion of saline. Intrathecal morphine provided at least 50% pain relief in 78% of patients given naloxone, and in 82% given saline. Intravenous naloxone significantly decreased the incidence of pruritus during labor and delivery. There was no significant decrease in the incidence of nausea, vomiting, somnolence, dizziness, or urinary retention in patients given naloxone. Despite placental transfer of naloxone, neonatal outcome was not adversely affected. For both groups, maternal beta-endorphin levels decreased significantly with the onset of analgesia and returned to control levels at delivery. We conclude that intravenous infusion of naloxone reduced pruritus after intrathecal injection of 1 mg of morphine for labor pain without lessening analgesia or adversely affecting maternal or neonatal status.

Anesthesia, Obstetrical

Safety and efficacy of epinephrine added to bupivacaine for lumbar epidural analgesia in obstetrics.

The effects of epidural bupivacaine with and without 1:300,000 epinephrine on uterine activity, progress of labor, fetal heart rate, maternal blood pressure and heart rate, newborn Apgar scores, neonatal acid-base status, and Neurologic and Adaptive Capacity Scoring System (NACS) were compared in 32 parturients during labor and delivery. Patients in group I (n = 16) received 0.5% bupivacaine with 1:300,000 epinephrine and those in group II (n = 16) received 0.5% bupivacaine alone. Addition of epinephrine to bupivacaine had no significant effects on uterine activity, duration of first or second stages of labor, fetal heart rate and variability, or the incidence of abnormal fetal heart rate patterns. Maternal hypotension occurred less frequently in group I than in group II patients (P less than 0.05). Apgar scores, neonatal acid-base status, and the NACS were equally good in the two groups. Duration of analgesia was significantly longer in group I than in group II (186.8 +/- 11.6 vs 85.3 +/- 6.1 (mean +/- SEM) min, P less than 0.001). It is concluded that adding epinephrine to bupivacaine during epidural anesthesia in the normal parturient has no adverse effects on either mother, fetus, neonate, or the progress of labor; and that it significantly prolongs the duration of anesthesia and decreases the incidence of maternal hypotension.

Adult

Comparison of the effects of general and regional anesthesia for cesarean section on neonatal neurologic and adaptive capacity scores.

Fifty-two neonates delivered by elective cesarean section were evaluated using the Neonatal Neurologic and Adaptive Capacity Scores. Twenty of the mothers received general anesthesia, 14 received epidural, and 18 received spinal anesthesia. All mothers receiving regional anesthesia were prehydrated with 1000 ml of lactated Ringer's solution and were given oxygen via a transparent face mask. All mothers undergoing general anesthesia received thiopental for induction followed by N2O-O2 (4 L:4 L) and 0.5% enflurane until delivery of the baby. All mothers were healthy, not in labor, and were scheduled for elective cesarean section. All neonates weighed 2500 g or more, had Apgar scores of 7 or more at 1 and 5 min, and had normal acid base and blood gas data. Neonates delivered with general anesthesia scored significantly lower on some of the test items for adaptive capacity, passive tone, active tone, primary reflexes, and total scores at both 15 min and 2 hr of age (P less than 0.05) than those delivered with either epidural or spinal anesthesia. Neonates delivered with epidural anesthesia scored lower than those delivered with spinal anesthesia on supporting reaction and motor activity at 2 hr of age (P less than 0.05). All neonates had high scores at 24 hr, at which time there were no significant differences between the three groups.

Adaptation, Psychological