Search PubMed⌕ Search

Biomedical subjects

T Juhasz

Publications and source records attributed to T Juhasz.

25 records · Page 2Linked to original sources

Finite element analysis applied to cornea reshaping.

A 2-D finite element model of the cornea is developed to simulate corneal reshaping and the resulting deformation induced by refractive surgery. In the numerical simulations, linear and nonlinear elastic models are applied when stiffness inhomogeneities varying with depth are considered. Multiple simulations are created that employ different geometric configurations for the removal of the corneal tissue. Side-by-side comparisons of the different constitutive laws are also performed. To facilitate the comparison, the material property constants are identified from the same experimental data, which are obtained from mechanical tests on corneal strips and membrane inflation experiments. We then validate the resulting models by comparing computed refractive power changes with clinical results. Tissue deformations created by simulated corneal tissue removal using finite elements are consistent with clinically observed postsurgical results. The model developed provides a much more predictable refractive outcome when the stiffness inhomogeneities of the cornea and nonlinearities of the deformations are included in the simulations. Finite element analysis is a useful tool for modeling surgical effects on the cornea and developing a better understanding of the biomechanics of the cornea. The creation of patient-specific simulations would allow surgical outcomes to be predicted based on individualized finite element models.

Computer Simulation↗

Ultrastructure of picosecond laser intrastromal photodisruption.

PURPOSE: To investigate the ultrastructure of the corneal stroma after picosecond intrastromal photodisruption with a neodymium-doped yttrium-lithium-fluoride (Nd:YLF) laser. METHODS: We performed picosecond intrastromal photodisruption on six human eye-bank eyes using a lamellar technique. Thirty picosecond pulses at 1000 Hz and 20 to 25 mJ per pulse were placed in an expanding spiral pattern, the pulses separated by 15 microns. Three layers were placed in the anterior stroma, separated from each other by 15 microns. In addition, intrastromal radial and arcuate incisions were generated in two living rabbit eyes in a plane perpendicular to the corneal surface. After the procedure, the corneas were processed for scanning and transmission electron microscopy. RESULTS: Scanning electron microscopy of the eye-bank eyes demonstrated multiple, coalescing intrastromal cavities forming a layer oriented parallel to the corneal surface. These cavities had smooth inner walls. Transmission electron microscopy demonstrated tissue loss surrounding some cavities, with the terminated ends of collagen fibrils clearly evident. Other cavities were formed by separation of lamellae, with little evidence of tissue loss. A pseudomembrane was present along the margin of some cavities. Although there was occasional underlying tissue disruption along the border of a cavity, there was no evidence of thermal damage or tissue necrosis. The perpendicular photodisruptions demonstrated intrastromal cleavage of corneal collagen similar to diamond-knife incisions, with the exception of intact overlying Bowman's and epithelial layers. CONCLUSION: Intrastromal photodisruption with a Nd:YLF picosecond laser induced no thermal necrosis or coagulative change in the region of tissue interaction. Lamellar intrastromal photodisruption demonstrated both tissue loss and lamellar separation when performed with the current treatment parameters, possibly limiting ablation efficiency and predictability.

Animals↗

The picosecond laser for nonmechanical laser in situ keratomileusis.

PURPOSE: To introduce the clinical use of the Nd:YLF picosecond laser as a nonmechanical microkeratome. METHODS: A commercially available Nd:YLF picosecond laser (25 microJ/pulse, 30 psec, 1053 nm) was used to deliver intrastromal pulses of focused high power laser light to generate a flap for laser in situ keratomileusis (LASIK) and perform picosecond laser keratomileusis (PLK) in two partially sighted patients with high myopia. RESULTS: Case #1: A 6 mm, 150 microns flap for LASIK was successfully created and the underlying stroma treated with an excimer laser for a target correction of -15.00 D of myopia. Good corneal clarity and a refractive change of -14.00 D was recorded 2 months postoperatively. Case #2: Both eyes of a high myope (-22.00 D right eye, -21.50 D left eye) underwent picosecond laser keratomileusis, removing a 3.2 mm diameter lenticule of 120 microns thickness under a 200 microns flap. Postoperative refraction was -2.00 D at 7 months in the right eye and -0.75 D at 2 months in the left eye with improvement of spectacle-corrected visual acuity from 20/200 to 20/70 in each eye. CONCLUSION: The Nd:YLF picosecond laser can be safely used in creating a corneal flap for LASIK and in performing picosecond laser keratomileusis for high myopia. Future refinements in the laser will include a larger flap diameter and femtosecond pulsing capability.

Corneal Stroma↗

Lamellar refractive surgery with scanned intrastromal picosecond and femtosecond laser pulses in animal eyes.

PURPOSE: To evaluate the use of scanned intrastromal picosecond and femtosecond laser pulses in lamellar refractive surgical procedures. METHODS: Intrastromal corneal photodisruption was performed in fresh porcine and primate cadaver eyes with a solid-state femtosecond laser. Laser pulses were focused 150 to 200 microns below the epithelial surface and scanned in a spiral pattern to create a plane. A flap was made by scanning an arc pattern from the plane of the spiral to the surface of the cornea. Tissue plane separation was graded using a standard scale, while internal surfaces were analyzed by scanning electron microscopy. Comparison was made to a picosecond laser system using the same delivery system device. Creation of a stromal lenticule for in situ keratomileusis was also demonstrated and compared with both laser systems. RESULTS: For femtosecond pulses, tissue separation was achieved best with pulse energies from 4 to 8 microJ and spot separations from 10-15 microns. Picosecond pulses accomplished less complete separations with pulse energies of 25 microJ and spot separations from 10 to 20 microns. Surface quality corresponded to dissection results, with high-grade dissections resulting in a smooth surface appearance, versus a more irregular surface for low-grade dissections. Although high-grade dissections could be created with picosecond pulses (with optimal parameters) in ex vivo porcine eyes, only femtosecond parameters produced similar results in ex vivo primate eyes. CONCLUSION: In contrast to previous attempts using picosecond lasers which require additional mechanical dissection, high precision lamellar refractive surgery may be practical with femtosecond laser pulses.

Animals↗

Mathematical models of picosecond laser keratomileusis for high myopia.

PURPOSE: Picosecond laser keratomileusis (PLK) is a refractive surgical procedure in which an intrastromal lenticle is created using the Nd:YLF picosecond laser and removed by lifting the anterior flap in the cornea. The purpose of this study was to assess the predictability of picosecond laser keratomileusis for high myopia. METHODS: The results from a recent clinical series of non-sighted patients who had undergone picosecond laser keratomileusis with the Nd:YLF picosecond laser were retrospectively simulated with two mathematical models. In one model, the change in corneal curvature resulting from the collapse of a lenticular intrastromal cavity was predicted from a geometric analysis. A second model was developed using the finite element method. The results of both predictive models were compared to the clinical results at 1 and 6 months following surgery. RESULTS: An average -13.30 D of flattening (range, -6.80 to -20.50 D) was measured at 6 months. The geometric model predicted an average correction of -23.10 D (range, -18.00 to -34.00 D), whereas the finite element model predicted an average curvature change of -17.40 D (range, -14.50 to -22.50 D). An average decrease in central pachymetry of 91 microm was measured at 6 months, as compared to a predicted decrease in thickness of 112 microm. CONCLUSIONS: The outcome of picosecond laser keratomileusis for high myopia predicted using a finite element based model shows greater change in the corneal curvature and corneal thickness compared to clinical results. The relatively thick lenticules that are removed for high myopia cause considerable deformational changes in the cornea, which preclude the use of a purely geometric/optical approach for predicting the resultant corneal curvature changes.

Cornea↗

An in vivo model of femtosecond laser intrastromal refractive surgery.

BACKGROUND AND OBJECTIVE: To develop an animal model for evaluation of femtosecond laser intrastromal refractive surgery. METHODS: Intrastromal photodisruption was performed in New Zealand Albino rabbits using a femtosecond laser system. This surgical pattern consisted of a 100 microm-tick pyramid of laser pulses starting 180 microm below the corneal surface. Animals underwent serial slit lamp examinations and corneal thickness measurements at 1,3,7,14, and 28 days, then monthly up to 1 year. RESULTS: Approximately 70 microm of central corneal thinning were seen at 1 week, remaining stable up to 7 months. CONCLUSIONS: Intrastromal photodisruption with femtosecond lasers produced consistent changes in corneal thickness without loss of corneal transparency. These changes were more stable than those produced with excimer laser procedures in a similar animal model.

Animals↗