Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.

This paper is about calibration of cone-beam (CB) scanners for both x-ray computed tomography and single-photon emission computed tomography. Scanner calibration refers here to the estimation of a set of parameters which fully describe the geometry of data acquisition. Such parameters are needed for the tomographic reconstruction step. The discussion is limited to the usual case where the cone vertex and planar detector move along a circular path relative to the object. It is also assumed that the detector does not have spatial distortions. We propose a new method which requires a small set of measurements of a simple calibration object consisting of two spherical objects, that can be considered as 'point' objects. This object traces two ellipses on the detector and from the parametric description of these ellipses, the calibration geometry can be determined analytically using explicit formulae. The method is robust and easy to implement. However, it is not fully general as it is assumed that the detector is parallel to the rotation axis of the scanner. Implementation details are given for an experimental x-ray CB scanner.

Calibration↗

The dual-ellipse cross vertex path for exact reconstruction of long objects in cone-beam tomography.

We investigate the way data are used in the algorithm proposed by Kudo and Saito for the exact reconstruction of long objects from axially truncated cone-beam projections. Specifically, we show that the algorithm wastes a large part of the data. To overcome the problem, we propose to use a vertex path consisting of two crossing ellipses, for which we devised a new reconstruction algorithm, called the cross algorithm, which does not waste data and is still suitable to exactly handle axial truncation. Results of reconstruction are presented on simulated data and real data from an experimental scanner.

Algorithms↗

A full-field modular gamma camera.

A modular gamma ray camera is described that gives useful image information over its entire crystal face. The lack of dead area on the periphery of the camera is made possible by a unique application of digital electronics and optimal position estimation using maximum likelihood (ML) estimates. The ML estimates are calculated directly from photomultiplier tube responses and stored in a lookup table, so the restriction of calculating the position estimates in separate circuitry is removed. Each module is designed to be optically and electronically independent, so that many modules can be combined in a large system. Results from a prototypical module, which has an active crystal area of 10 cm X 10 cm, are presented.

Equipment Design↗