Environmental stress-corrosion cracking of fiberglass: lessons learned from failures in the chemical industry.

Fiberglass reinforced plastic (FRP) composite materials are often used to construct tanks, piping, scrubbers, beams, grating, and other components for use in corrosive environments. While FRP typically offers superior and cost effective corrosion resistance relative to other construction materials, the glass fibers traditionally used to provide the structural strength of the FRP can be susceptible to attack by the corrosive environment. The structural integrity of traditional FRP components in corrosive environments is usually dependent on the integrity of a corrosion-resistant barrier, such as a resin-rich layer containing corrosion resistant glass fibers. Without adequate protection, FRP components can fail under loads well below their design by an environmental stress-corrosion cracking (ESCC) mechanism when simultaneously exposed to mechanical stress and a corrosive chemical environment. Failure of these components can result in significant releases of hazardous substances into plants and the environment. In this paper, we present two case studies where fiberglass components failed due to ESCC at small chemical manufacturing facilities. As is often typical, the small chemical manufacturing facilities relied largely on FRP component suppliers to determine materials appropriate for the specific process environment and to repair damaged in-service components. We discuss the lessons learned from these incidents and precautions companies should take when interfacing with suppliers and other parties during the specification, design, construction, and repair of FRP components in order to prevent similar failures and chemical releases from occurring in the future.

Chemical Industry↗

A novel reconstruction algorithm to extend the CT scan field-of-view.

For various reasons, a projection dataset acquired on a computed tomography (CT) scanner can be truncated. That is, a portion of the scanned object is positioned outside the scan field-of-view (SFOV) and the line integrals corresponding to those regions are not measured. A projection truncation problem causes imaging artifacts that lead to suboptimal image quality. In this paper, we propose a reconstruction algorithm that enables an adequate estimation of the projection outside the SFOV. We make use of the fact that the total attenuation of each ideal projection in a parallel sampling geometry remains constant over views. We use the magnitudes and slopes of the projection samples at the location of truncation to estimate water cylinders that can best fit to the projection data outside the SFOV. To improve the robustness of the algorithm, continuity constraints are placed on the fitting parameters. Extensive phantom and patient experiments were conducted to test the robustness and accuracy of the proposed algorithm.

Algorithms↗

Development of real-time RT-PCR for the detection of avian influenza virus.

A real-time reverse transcriptase/polymerase chain reaction (RRT-PCR) assay was developed using hydrolysis probes for the detection of avian influenza virus (AIV) and the H5 and H7 subtypes. The AIV specific primers and probes were directed to regions of the AIV matrix gene that are conserved among most type A influenza viruses. The H5 and H7 primers and probes are directed to H5 and H7 hemagglutinin gene regions that are conserved among North American avian influenza viruses. The sensitivity and specificity of this RRT-PCR assay was compared to virus isolation (VI) in chicken embryos with 1550 clinical swab samples from 109 live-bird markets (LBMs) in New York and New Jersey. RRT-PCR detected influenza in samples from 61 of 65 (93.8%) of the LBMs that were the sources of VI positive samples. Of the 58 markets that were positive for H7 influenza by hemagglutination inhibition assay, RRT-PCR detected H7 influenza in 56 markets (96.5%). Too few H5 positive samples were obtained to validate the H5 RRT-PCR assay in this study. Although RRT-PCR was less sensitive than VI on an individual sample basis, this study demonstrated that the AIV and H7 RRT-PCR assays are good tools for the rapid screening of flocks and LBMs.

Animals↗

Descriptive and surveillance studies of suppliers to New York and New Jersey retail live-bird markets.

Low pathogenicity avian influenza virus (AIV) H7N2 has been isolated since 1994 from retail live-bird markets (LBMs) in the northeastern United States. This study examines the suppliers to the LBMs in New York and New Jersey. In 2001, 185 supplier premises in nine states were surveyed for the presence of AIV by virus isolation (VI) in embryonating chicken eggs. No H7 or H5 virus was isolated. In addition, 104 producer premises in two states were serologically negative for H7 and H5 AIV. Information on management practices was obtained via questionnaire for 191 premises in 12 states. The survey results suggest that current biosecurity practices at supplier premises could be improved, especially regarding movement of birds. The study supports the hypothesis that H7N2 AIV is primarily maintained within the LBMs and, if reintroduction from suppliers is occurring, it is likely reintroduced at a very low level or from suppliers not included in this study.

Animals↗

USDA options for regulatory changes to enhance the prevention and control of avian influenza.

During the past decade, several examples of the ability of H5 and H7 low-pathogenicity avian influenza (LPAI) viruses to mutate to high-pathogenicity (HP) viruses have been documented worldwide. During this time, the introduction and persistence of an H7N2 LPAI virus in the northeast live-bird marketing system in the United States has raised concern on how to prevent the possibility of such a mutation occurring in this country. The United States has periodically experienced trade restrictions based on the occasional introduction of H5 and H7 LPAI viruses into commercial poultry and based on AI-related changes in the import requirements for poultry and poultry products of several of our trading partners. Consequently, the U.S. Department of Agriculture (USDA) is exploring options for how our regulatory response to H5 and H7 LPAI viruses might be revised to better protect our domestic poultry flocks from HPAI and to ensure that any interruptions in trade are scientifically supportable. The options under consideration include mandatory and voluntary measures to improve the surveillance for and control of H5 and H7 LPAI virus infections.

Animals↗

Epidemiologic and surveillance studies on avian influenza in live-bird markets in New York and New Jersey, 2001.

In 2001, all 109 retail live-bird markets (LBMs) in New York and New Jersey were surveyed for the presence of avian influenza virus (AIV) by a real time reverse transcriptase/polymer chain reaction assay (RRT/PCR) and results compared to virus isolation (VI) in embryonating chicken eggs. The RRT/PCR had a 91.9% sensitivity and 97.9% specificity in detecting presence of AIV at the market level. However, the sensitivity at the sample level is 65.87%. The RRT/PCR is a reliable method to identify AIV at the market level. In addition, a cross-sectional epidemiologic study of the LBMs showed that, during the past 12 months, markets that were open 7 days per week and those that also sold rabbits had the highest risk for being positive for AIV. Markets that were closed one or more days per week and those that performed daily cleaning and disinfecting had the lowest risk for being AIV positive.

Animals↗

Development of a real-time reverse transcriptase PCR assay for type A influenza virus and the avian H5 and H7 hemagglutinin subtypes.

A real-time reverse transcriptase PCR (RRT-PCR) assay based on the avian influenza virus matrix gene was developed for the rapid detection of type A influenza virus. Additionally, H5 and H7 hemagglutinin subtype-specific probe sets were developed based on North American avian influenza virus sequences. The RRT-PCR assay utilizes a one-step RT-PCR protocol and fluorogenic hydrolysis type probes. The matrix gene RRT-PCR assay has a detection limit of 10 fg or approximately 1,000 copies of target RNA and can detect 0.1 50% egg infective dose of virus. The H5- and H7-specific probe sets each have a detection limit of 100 fg of target RNA or approximately 10(3) to 10(4) gene copies. The sensitivity and specificity of the real-time PCR assay were directly compared with those of the current standard for detection of influenza virus: virus isolation (VI) in embryonated chicken eggs and hemagglutinin subtyping by hemagglutination inhibition (HI) assay. The comparison was performed with 1,550 tracheal and cloacal swabs from various avian species and environmental swabs obtained from live-bird markets in New York and New Jersey. Influenza virus-specific RRT-PCR results correlated with VI results for 89% of the samples. The remaining samples were positive with only one detection method. Overall the sensitivity and specificity of the H7- and H5-specific RRT-PCR were similar to those of VI and HI.

Animals↗

Research and development of an implantable, axial-flow left ventricular assist device: the Jarvik 2000 Heart.

Advances in technology and increased clinical need have led to the development of a new type of blood pump. The Jarvik 2000 Heart is an electrically powered, axial-flow left ventricular assist device that has been developed during the past 13 years. Unlike first-generation left ventricular assist devices, which were developed in the 1970s and were designed to totally capture the cardiac output, the Jarvik 2000 is designed to normalize the cardiac output by augmenting the function of the chronically failed heart for extended periods. Design iterations have been tested in 67 animals, and clinical trials have recently begun. Three patients have received the Jarvik 2000 as a bridge to transplantation, and 1 patient is being supported permanently outside the hospital. All 4 patients have improved from New York Heart Association functional class IV to class I, and 2 of them have been discharged from the hospital after heart transplantation. The experimental and clinical results indicate that the Jarvik 2000 can provide physiologic support with minimal complications and is reliable, biocompatible, and easy to implant.

Animals↗

Myocardial tumor necrosis factor-alpha expression does not correlate with clinical indices of heart failure in patients on left ventricular assist device support.

BACKGROUND: Mechanical unloading with a left ventricular assist device (LVAD) can improve clinical indices of heart failure and alter myocardial tumor necrosis factor-alpha (TNFalpha) expression, but a correlation between clinical and molecular indices has not been established. METHODS: We enrolled 14 patients with end-stage heart failure treated with drugs and mechanical unloading in a protocol including the collection of myocardial tissue samples at LVAD implantation and explantation. Ten nonfailing donor hearts served as controls. TNFalpha expression was measured by quantitative reverse transcription polymerase chain reaction. Clinical indices of heart failure were retrospectively analyzed and correlated with myocardial TNFalpha expression. RESULTS: Left ventricular end-diastolic dimension decreased (p < 0.01) and cardiac index (p < 0.001) increased with unloading. Abnormal values of serum sodium, creatinine, blood urea nitrogen, glutamic-oxaloacetic transaminase, glutamic-pyruvic transaminase, and albumin showed a trend toward normalization with mechanical unloading. TNFalpha expression was increased in 5 of 14 patients and decreased with mechanical unloading in 4 of them. Surprisingly, there was no correlation between mRNA levels of TNFalpha and any of the clinical indices studied. CONCLUSIONS: Although clinical indices of heart failure improve and elevated levels of myocardial TNFalpha expression decrease with mechanical unloading, there is no correlation between the two. Thus, clinical and molecular indices of heart failure in LVAD-supported patients do not always correlate.

Adolescent↗

First permanent implant of the Jarvik 2000 Heart.

BACKGROUND: Heart failure is a major public-health concern. Quality and duration of life on maximum medical therapy are poor. The availability of donor hearts is severely limited, therefore an alternative approach is necessary. We have explored the use of a new type of left-ventricular assist device intended as a long-term solution to end-stage heart failure. METHODS: As part of a prospective clinical trial, we implanted the first permanent Jarvik 2000 Heart--an intraventricular device with an innovative power delivery system--into a 61-year-old man (New York Heart Association functional class IV) with dilated cardiomyopathy. We assessed the effect of this left-ventricular assist device on both native heart function and the symptoms and systemic characteristics of heart failure. FINDINGS: The Jarvik 2000 Heart sustained the patient's circulation, and was practical and user-friendly. After 6 weeks, exercise tolerance, myocardial function, and end-organ function improved. Symptoms of heart failure have resolved, and continuous decreased pulse-pressure perfusion has had no adverse effects in the short term. There has been no significant haemolysis and no device-related complications. The skull-mounted pedestal is unobtrusive and has healed well. CONCLUSIONS: The initial success of this procedure raises the possibility of a new treatment for end-stage heart failure. In the longer term, its role will be determined by mechanical reliability.

Blood Pressure↗

Left ventricular assist system as a bridge to myocardial recovery.

BACKGROUND: Despite recent advances in medical therapy, heart transplantation, and mechanical circulatory support, the mortality of patients with congestive heart failure remains high. METHODS: Retrospective data on 5 patients were obtained from our hospital's medical records. Each patient was supported by a left ventricular assist system (LVAS) because of severe congestive heart failure. The duration of LVAS support averaged 229 days (range, 46 to 447 days). In 3 patients, the LVAS was removed electively after the patient showed recovery of myocardial function. In the other 2, it was removed because of a malfunction. RESULTS: In response to LVAS support, hemodynamic variables were significantly improved. The mean cardiac index increased from 1.45 to 2.69 L x min(-1) x m(-2) (p < 0.001) and the mean left ventricular ejection fraction increased from 0.144 to 0.288 (p < 0.025). All patients were in New York Heart Association functional class IV at LVAS implantation and class I at its explantation. One patient died of noncardiac-related causes 10 days after LVAS removal. The remaining 4 patients are alive and well 35, 33, 14, and 2 months after LVAS removal. CONCLUSIONS: In select patients with severe congestive heart failure, mechanical unloading with an LVAS can result in recovery of myocardial function. These patients can return to a normal physical status, thereby avoiding heart transplantation. More research is required to determine optimal modes of LVAS support, to predict which patients are likely to recover, and to assess long-term outcomes.

Adult↗

Authorities and procedures for licensing veterinary biological products in the United States.

The licensing procedures reviewed above provide a framework for the production of pure, safe, potent, and efficacious veterinary biological products. The licensing, inspection, and testing activities of the Veterinary Biologics program provide the oversight necessary to ensure the continued availability of high-quality veterinary biological products in the United States.

Biological Products↗

Familial amyloid with a transthyretin leucine 33 mutation presenting with ascites.

A 65-year-old female presented with symptomatic ascites. Light and electron microscopy examination of omental and peritoneal tissue obtained at exploratory laparotomy revealed amyloidosis. Immunochemical studies of the amyloid tissue showed positive staining with antibodies to transthyretin. Polymerase chain reaction (PCR), single strand conformation polymorphism analysis, and direct DNA sequencing demonstrated a transthyretin phenylalanine to leucine substitution at codon 33. This is only the second reported case of a transthyretin leucine 33 mutation. Moreover, this patient is unique among cases of transthyretin-associated amyloidosis with the clinical presentation of ascites.

Aged↗

The HeartMate left ventricular assist system. Overview and 12-year experience.

Cardiac transplantation has become a widely accepted option for treating end-stage heart failure. As the waiting time for donor hearts grows, new generations of left ventricular assist systems are being developed for patients awaiting transplantation. Great strides have been made in the study and use of such devices, both as temporary support and (perhaps ultimately) as permanent implants. The Texas Heart Institute has been involved with the development of the HeartMate left ventricular assist systems, which have been used almost exclusively as a temporary bridge. Herein we review our 12-year clinical experience with the HeartMate left ventricular assist systems as a bridge to transplantation and as a long-term circulatory assist device that aids in cardiac repair. Trials of the HeartMate as a permanent support system for patients with end-stage heart failure who are not suitable candidates for transplantation are currently under way.

Adolescent↗

New Gianturco-Grifka vascular occlusion device. Initial studies in a canine model.

BACKGROUND: Transcatheter closure of cardiovascular defects remains a challenge. Several occlusion devices are available, but each device has limitations. The purpose of this study was to evaluate the new Gianturco-Grifka vascular occlusion device (GGVOD) in a canine model. METHODS AND RESULTS: A total of 26 GGVODs were implanted as part of short- and long-term studies. In the short-term study, 1 GGVOD was implanted in each of 11 systemic arteries from 3.2 to 9.0 mm in diameter. All 11 arteries were occluded immediately. In the long-term study, an aortopulmonary shunt was placed in 10 dogs (9, Gore-tex graft; 1, subclavian artery) followed by GGVOD implantation; additionally, a GGVOD was implanted in 5 subclavian arteries. The dogs were boarded for 3 to 6 months, then recatheterized and euthanatized. Immediately after implantation, the 5 subclavian arteries and 9 Gore-tex shunts were occluded completely; the 1 subclavian artery shunt had a small residual leak. At recatheterization, all 10 shunts and 5 subclavian arteries were occluded completely. Necropsy revealed all shunts to be occluded, with the aortic and pulmonic orifices covered with a neointimal layer. The mean fluoroscopic time needed for GGVOD implantation was 9 minutes (range, 3 to 22 minutes). CONCLUSIONS: (1) In a canine model, the GGVOD is effective for transcatheter occlusion of arteries and aortopulmonary shunts from 3 to 9 mm in diameter. Possible indications in children include aortopulmonary collateral vessels, long patent ductus arteriosus, systemic-pulmonary shunts, AV malformations, and arteries supplying tumors. (2) GGVOD implantation requires a short fluoroscopic time.

Animals↗