A complete understanding of the mode of evolution of molecular markers is important for making inferences about different population genetic parameters, especially because a number of studies have reported patterns of allelic variation at molecular markers that are not in agreement with neutral evolutionary expectations. In the present study, house mice (Mus domesticus) from the fourteenth generation of a selection experiment for increased voluntary wheel-running activity were used to test how selection on a complex behavior affects the distribution of allelic variation by examining patterns of variation at six microsatellite and four allozyme loci. This population had a hierarchical structure that allowed for simultaneous testing of the effects of selection and genetic drift on the distribution of allelic variation by comparing observed patterns of allele frequencies and estimates of genetic divergence at multiple hierarchical levels to expectations under models of neutral evolution. The levels of genetic divergence among replicate lines and between selection groups, estimated from microsatellite data or pooled microsatellite and allozyme data, were not significantly different from expectations under neutral evolution. Furthermore, the pattern of change of allele frequencies between the base population and generation 14 was largely in agreement with expectations under neutral evolution (although the PGM locus exhibited a pattern of change within populations that was difficult to explain under neutral evolution). Overall the results generally provide support for the neutral evolution of molecular markers.

Animals↗

Energy dependence of correction factors for some Victoreen Model 570 Condensor R-Meter medium-energy chambers.

The energy dependence of each of six models of medium-energy Victoreen 570 Condenser R-Meter chambers was determined by measurement of the exposure correction factors over the diagnostic x-ray beam-quality range (0.4-4.1 mm A1 HVL) for several samples of each model. The results of an analysis of variance performed by model on the correction factors are reported as mean correction factors for the x-ray beams evaluated, with a relative standard error less than 0.8% in all cases. Energy-dependence curves for the six chamber models are given; their use is described.

Calibration↗

Energy dependence of correction factors for some low-energy direct-reading pocket dosimeters.

The energy dependence for each of five models of low-energy direct-reading pocket dosimeters was characterized through an examination of the exposure correction factors determined over the diagnostic x-ray range (0.4-4.1-mm Al HVL) for many samples of each model. The results of an analysis of variance performed by model on the correction factors are reported as mean correction factors for the x-ray beams evaluated, the relative standard error being less than 0.8% in all cases. Energy-dependence curves for the dosimeter models are given, and their use is described.

Radiography↗

Energy dependence of correction factors for two models of Keithley diagnostic ion chambers.

The energy dependence for each of two models of ionization chambers compatible with the Keithley model 35020 Digital Dosimeter, is determined by measurement of the exposure correction factors determined over the diagnostic x-ray range (0.4--4.9 mm AL HVL) for several for several samples of each model. The results of an analysis of variance performed by model on the correction factors are reported as mean correction factors for the x-ray beams evaluated, with a relative standard error of less than 1% for both cases. Energy-dependence curves for the two chamber models are given, and their use is described.

Evaluation Studies as Topic↗

A technique for routine calibration of thermoluminescent dosimeters in the diagnostic energy range.

Four different techniques for calibrating lithium fluoride thermoluminescent dosimeters were compared at two beam qualities in the diagnostic energy range. The techniques included in-air, saturation backscatter, and Bureau of Radiological Health (BRH) test stand geometry with and without an ionization chamber. The results indicate that there are no statistical differences between any of the calibration techniques evaluated. Hence, the technique using the BRH test stand with an ionization chamber is a simple and reproducible calibration procedure which may be used in a routine diagnostic radiology quality assurance program.

Fluorides↗