Search PubMed⌕ Search

Biomedical subjects

T J Beck

Publications and source records attributed to T J Beck.

44 records · Page 3Linked to original sources

Image quality and radiation levels in videofluoroscopy for swallowing studies: a review.

Inexpensive video recording equipment coupled to conventional x-ray fluoroscopes is now in widespread use by clinicians for the evaluation of patients with swallowing disorders. The prevalence and simplicity of this apparatus have encouraged its use by clinical specialists who are often not specifically trained in the safe use of x-ray equipment, and this may not be in the best interest of either the patient or the examiner. This has prompted an overview of the operating principles of videofluorescopy equipment. The factors governing image quality are discussed as well as potential hazards and protective measures for both patients and operator. A method of estimating the radiation dose to sensitive tissues from a typical swallowing study is included.

Cineradiography↗

Predicting femoral neck strength from bone mineral data. A structural approach.

An interactive computer program was developed to derive femoral neck geometry from raw bone mineral image data for an estimate of hip strength using single plane engineering stress analysis. The program, which we call Hip Strength Analysis (HSA), was developed as an attempt to improve the predictive value of hip bone mineral data for osteoporosis fracture risk assessment. We report a series of experiments with an aluminum phantom and with cadaver femora, designed to test the accuracy of derived geometric measurements and strength estimates. Using data acquired with both Lunar DP3 (DPA) and Hologic QDR-1000 (x-ray) scanners, HSA computed femoral neck cross-sectional areas (CSA) and cross-sectional moments of inertia (CSMI) on an aluminum phantom were in excellent agreement with actual values (r greater than .99). Using Lunar DP3 data, CSA and CSMI measurements at mid-femoral necks of 22 cadaver specimens were in good general agreement with literature values. HSA computed cross-sectional properties of three of these specimens were compared with measurements derived from sequential CT cross-sectional images. Discrepancy between the two methods averaged less than 10% along the length of the femoral neck. Finally, breaking strengths of 20 of the femora were measured with a materials testing system, showing better agreement with HSA predicted strength (r = .89, percent standard of the estimate (%SEE) = 21%) than femoral neck bone mineral density (r = .79, %SEE = 28%).

Absorptiometry, Photon↗

Sequential computed tomographic imaging of a transplantable rabbit brain tumor.

The accuracy of CT imaging in evaluating VX-2 tumor growth in the rabbit brain was assessed. CT scanning was performed in 5 outbred New Zealand white male rabbits before and at 4, 7, 9 and 13 (in 3 animals) days after surgical implantation of 3 X 10(5) viable VX-2 tumor cells in the frontoparietal lobes. The CT studies were correlated with gross pathology in each. The tumor was visualized with CT in all 5 rabbits by the 9th day post implantation when the tumor ranged in size from 4-6 X 3-4 X 2-3 mm. Between the 9th and 13th day, the tumor increased 6-fold in two rabbits and 12-fold in the third rabbit. CT is a useful technique to evaluate brain tumor growth in this model and should be valuable in documenting the efficacy of chemotherapy on tumor growth.

Animals↗

Monitoring radiation exposure to medical personnel during percutaneous nephrolithotomy.

To ascertain radiation exposure to medical personnel during percutaneous nephrolithotomy, lithium fluoride thermoluminescent dosimeters (TLDs) were utilized for the radiographic monitoring of 7 consecutive patients. Average fluoroscopy time per procedure was 27.8 minutes of which 15.1 minutes were for nephrostomy tube insertion and 12.7 minutes were for calculi extraction. The 2 radiologists received 4.5 and 5.1 mrad per procedure, while the 2 urologists received 2.5 and 3.7 mrad. All other ancillary personnel received less than 2.1 mrad per procedure except the anesthesiologists whose mean exposure was 4.7 mrad. By taking appropriate precautions and using the proper equipment, percutaneous nephrolithotomy can be performed with a low level of radiation exposure for all involved physicians and personnel.

Adult↗

Orbital computed tomography: technical aspects.

Computed tomographic scanning has revolutionized the diagnosis and management of orbital disease. The best use of this methodology requires knowledge of the principles and appropriate attention to scanning protocols. Computed tomographic scanning of the orbit is a demanding technique requiring thin sections through planes precisely positioned from the topographical anatomy. Ideally, orbital CT should include both transverse axial and coronal sections: The pathological condition and its plane of growth will influence the selection of the optimal plane or section. Coronal sections may be obtained either directly or indirectly by computer reconstruction from contiguous transverse images. Sagittal or oblique sections or both also are useful and may be obtained directly or indirectly. Difficulty in patient positioning may preclude direct sagittal imaging, however. The use of intravenous contrast enhancement is not necessary as a routine technique unless a mass is identified or suspected. Where surgical resection or biopsy of a space-occupying lesion is contemplated, contrast enhancement can be valuable in assessing relative vascularity and aiding diagnostic specificity. It should be continually emphasized that CT is a powerful technology which, in orbital diagnosis, produces the highest yield when clinician and radiologist collaborate in the radiodiagnostic workup. The clinical information supplied by the referring ophthalmologist is used by the radiologist both in the selection of the appropriate techniques for investigation and in striving to achieve the most specific conclusion.

Contrast Media↗

Precision bone and muscle loss measurements by advanced, multiple projection DEXA (AMPDXA) techniques for spaceflight applications.

An advanced, multiple projection, dual energy x-ray absorptiometry (AMPDXA) scanner system is under development. The AMPDXA is designed to make precision bone and muscle loss measurements necessary to determine the deleterious effects of microgravity on astronauts as well as develop countermeasures to stem their bone and muscle loss. To date, a full size test system has been developed to verify principles and the results of computer simulations. Results indicate that accurate predictions of bone mechanical properties can be determined from as few as three projections, while more projections are needed for a complete, three-dimensional reconstruction.

Absorptiometry, Photon↗

Examining the developing bone: What do we measure and how do we do it?

The clinical tools available to evaluate bone development in children are often ambiguous, and difficult to interpret. Unfortunately bone densitometry methods (i.e., dual energy X-ray absorptiometry, DXA) which have a relatively straightforward application in adult osteoporosis, are far more difficult to evaluate in the growing skeleton. Even with adequate "adjustment" for bone size or maturity, bone "density" (areal or volumetric) alone often gives an inaccurate assessment of bone strength--especially in children. Ideally, we would like to measure both material and geometric properties of bone to accurately estimate "strength". Mechanically meaningful measures of bone geometry (bone cross-sectional area, cortical thickness) and estimates of bending strength (section modulus, or SSI) are available with non-invasive techniques such as (p)QCT and some DXA software. With new technology it might be possible to also measure bone material properties, which will be especially important in some pediatric disorders. In children, we also need to know something about the loads imposed on a child's bone and consider not only absolute bone strength, but also the strength of bone relative to the physiologic loads. Interpreting bone strength in light of the loads imposed (particularly muscle force) is critical for an accurate diagnosis of the developing bone.

Aging↗