The second and third model of the flow transformed pulsatile total artificial heart.

For the purpose of future total implantation, a new pulsatile total artificial heart, a flow transformed pulsatile total artificial heart (FTPTAH), in which the continuous flow from a single centrifugal pump (CFP) was converted to pulsatile flow by switching two three-way valves that could alternately perfuse the systemic and pulmonary circulation, was proposed, and the data from the prototype model were reported. As the next step, the second model, in which a CFP and a spool valve (SV) driven with a solenoid were fabricated in one piece, was made and tested in a mock circulatory system. The system could send 4.7 L/min of pulsatile output alternately to the pulmonary artery and aorta, with 30 and 100 mmHg afterload, respectively, at 3000 rpm CFP. However, three problems were encountered: the output was not enough, mixture or inversion of venous and arterial blood in the CFP would occur, and heat generation at the solenoid was very severe. To solve these problems, a third model was designed in the current study. To increase pump output, hydrodynamic analysis was performed. The SV was divided into inlet and outlet to control the blood mixture or inversion. To suppress heat generation, each SV was driven back and forth by two solenoids, one on each side of the SV. The model revealed satisfactory results in a mock circulatory system.

Biomedical Engineering↗

A new apparatus for chronic observation of the microcirculation in situ to evaluate artificial organ performance.

Chronic study of the peripheral circulation and metabolism is very important in evaluation of artificial organ performance. However, there has been no way to observe the microcirculation in situ, chronically and continuously, without restriction. In this study, the authors developed a new apparatus that could be implanted and connected to an artificial organ that would allow continuous observation of the microcirculation while the subject is awake. The apparatus uses a charge coupled device (CCD) under a new principle: thin living tissue, such as mesentery, is put directly on a highly integrated CCD and transilluminated with a light emitting diode (LED). The vascular nets in the tissue are projected onto the CCD like a contact photograph, which is sent to a television screen and can be analyzed for motion and function. A 0.5 inch CCD with 25K pixels was used in this study. The cover glass of the CCD was removed so the tissue would be able to directly contact the CCD surface. The CCD, as well as LED, were molded with hard polyurethane as electrical insulation. The apparatus is 35 mm in diameter and 10 mm high with a micro stand for lighting with the LED, which is easy to implant in a goat or calf. The resolution of this apparatus was tested by putting a micro scale on the CCD surface. Several tenths of micrometers could be seen. In an animal experiment with a rabbit, configurations of arterioles and venules and their motions could be observed continuously for a night until the electrical insulation was broken. This method might be a strong weapon in artificial organs research.

Animals↗

Results of animal experiments using an undulation pump total artificial heart: analysis of 10 day and 19 day survival.

An undulation pump is a special rotary blood pump in which rotation of a brushless DC motor is transformed to an undulating motion by a disc in the pump housing attached by means of a special link mechanism. In the blood pump, a closed line between the disc and housing moves from the inlet to the outlet by this undulating disc motion, which sucks and pushes the blood from the inlet to the outlet. Because the same phenomena occurs at both sides of the disc, a continuous flow is obtained when the motor rotational speed is constant. The pump flow pattern can be easily changed from continuous flow to pulsatile flow by controlling the motor drive current pattern. A seal membrane made of segmented polyurethane protects the blood from invading the link mechanism as well as the motor. UPTAH is fabricated with two undulation pumps and two brushless DC motors. Its size is 75 mm in diameter and 80 mm long, and it has one of the great advantage of no compliance chamber required in the system. UPTAHs were implanted under cardiopulmonary bypass (CPB) into the chest cavities of 16 goats, each weighing between 41 and 72 kg. No anticoagulant and antiplatelet agent was used after the surgery. The left atrial pressure was automatically controlled to prevent its elevation and sucking of the atrial wall into the atrial cuff. The following results were obtained: (1) UPTAHs fit well into all the goats; (2) the longest survival was 19.8 days, the cause of death was bleeding from the aortic anastomosis; (3) No thrombus was observed in the blood pump despite no anticoagulant use. Hemolysis depended upon the length of CPB during surgery. When CPB time was within 2 hours, hemolysis level returned to baseline within a few days of the surgery. UPTAH is a promising implantable TAH, because of its small size and easy controllability.

Animals↗

A new pulsatile total artificial heart using a single centrifugal pump.

A new pulsatile total artificial heart (TAH) system, combining a single centrifugal pump (CFP) with two three-way valves, was developed. One port of each three-way valve was connected to the inlet and outlet of a CFP, respectively. The other two ports of each valve ware connected to the right and left atrium, pulmonary artery, and aorta. The CFP can perfuse the pulmonary and systemic circulation alternately with pulsatile flow. A prototype system composed of a Sarns' CFP and solenoid valves was connected to a mock circulatory system resulting in 1) a pulsatile TAH that could be produced with a single CFP, 2) 5 L/min of pulsatile output with a normal flow wave form that can be obtained alternately on the right and left side by switching the solenoid valves, and 3) flow balance between the left and the right that could be controlled easily by the length of switching duration. This new system could be miniaturized and is feasible for a totally implantable TAH.

Blood Flow Velocity↗

Can total artificial heart animals control their TAH by themselves? One year survival of a TAH goat using a new automatic control method (1/R control).

A total artificial heart (TAH) goat survived for 360 days on the new automatic control method (1/R control), in which the cardiac output of the TAH can be controlled through the cardiovascular center by making it function by reflecting the beta-adrenergic reaction in peripheral vascular resistance. This is thought to be the only long-term, real-time, measurable parameter by which information on the activity of the cardiovascular center can be received directly by the TAH system. In this goat, the hemodynamic parameters (RAP, AoP, and so forth) were kept within physiologic limits when control was stable, and the cardiac output was automatically increased in response to exercise, not unlike that in the natural heart. There were no abnormal blood chemical or hormone data except at end stage. Based on these results 1/R can be considered a physiologic control method for a TAH.

Animals↗