Search PubMedSearch

Biomedical subjects

T Ifukube

Publications and source records attributed to T Ifukube.

At least 19 recordsLinked to original sources

Proposal of a new method for narrowing and moving the stimulated region of cochlear implants: animal experiment and numerical analysis.

We have proposed the tripolar electrode stimulation method (TESM) for narrowing the stimulation region and continuously moving the stimulation site for cochlear implants. The TESM stimulates the auditory nerve array using three adjacent electrodes which are selected among the electrodes of an electrode array within the lymphatic fluid. Current is emitted from each of the two lateral electrodes and received by the central electrode. The current received by the central electrode is made equal to the sum of the currents emitted from the lateral electrodes. In this paper, we evaluate whether or not TESM works according to a theory which is based on numerical analysis using an electrical equivalent circuit model of the auditory nerve fibers. In this simulation, the sums of the excited model fibers are compared to the compound action potentials (CAP's) which we obtained through animal experiments. To identify the main parameter while maintaining the amplitude of the CAP (the sum of the fired fibers), we assumed the presence of some parameters from the radial current density profile. In the case of the width value among the parameters being kept constant, the amplitude of the CAP was almost constant; thus, the number of the fired fibers was also almost constant. The width value equals the distance between the points at which the profile of the radial current density of the electrode array and the line of the radial threshold current density of the electrode array intersect. It is possible to determine the measure of the stimulation region or site by controlling the width value and the ratios of the currents emitted from the lateral electrodes. As a result, we succeeded in narrowing the stimulation region by controlling the sum of the currents emitted from the two lateral electrodes. Also we succeeded in continuously moving the stimulation site by modifying the currents emitted from the two lateral electrodes.

Action Potentials

Application of hydrogen absorbing alloys to medical and rehabilitation equipment.

As power sources for rehabilitation equipment, electric, hydraulic, and pneumatic actuators have been used. However a more human-sized and higher powered actuator that can reduce the equipment size is desired. A new metal hydride (MH) actuator that uses the reversible reaction between the heat energy and mechanical energy of a hydrogen absorbing alloy has recently attracted much attention. The MH actuator is characterized by its small size, low weight, noiseless operation and a compliance similar to that of the human elbow joint. Therefore, the MH actuator has the characteristic of being light and easy to use and so is suitable for use in medical and rehabilitation applications. Some lifting devices using this actuator have already been developed and are being used for the care of the aged and disabled. The characteristics of the MH actuator are presented and then some applications are introduced in this paper. It is our opinion that in our aging society the MH actuator will play an important role in the development of medical and rehabilitation equipment.

Absorption

Preliminary study of improved perception of words with the same sound but different intonation in tinnitus patients following electrical stimulation of the ear.

The present study aimed to explain how tinnitus relief following electrical promontory stimulation affects detection of changes in pitch frequency. To determine the effects of tinnitus relief on the auditory system. Japanese words with the same sound but different intonation were used to verify the effects of tinnitus relief on pitch detection in tinnitus patients Eight out of 11 patients experienced relief of tinnitus following treatment. The averaged number of the ratio in 8 patients with relief of tinnitus, 0.58, was significantly higher (p < 0.02) than that in 3 patients without relief, 0.15. In comparison with averaged hearing level, there was no significant difference in averaged hearing level between 8 patients with relief of tinnitus (52.4 dBSL; SD: 11.4) and 3 without relief of tinnitus (58.0 dBSL; SD: 14.7) (p > 0.68). No significant difference in age between patients with and without relief of tinnitus was observed.

Aged

Improved word perception in tinnitus patients following electrical stimulation of the ear: a preliminary report.

The present study showed that there were close relationships between tinnitus relief and improved word perception by means of a grammatically correct but non-sense Japanese word perception test. Fourteen out of 20 patients reported tinnitus relief and improvement in hearing. Nine out of the 14 patients were thought to be significantly improved in word perception. Improved word perception was observed in 7 out of 10 patients whose ears tested were opposite to ears treated while in 2 out of 10 patients whose ears tested were the same as ears treated. Improved word perception was observed in 5 patients at one segment, 2 patients at two segments and 2 patients at three segments. Improved word perception was observed in one patient at the first segment, 5 patients at the second segment, 5 patients at the third segment and 5 patients at the fourth segment. There were no significant differences in hearing level nor age in patients with and without relief of tinnitus.

Electric Stimulation

Improved word perception following electrical stimulation of the ear in hearing-impaired patients without tinnitus.

Improved word perception in hearing-impaired patients following electrical stimulation of ears was shown by means of a grammatically correct but non-sense Japanese 4-segment sentence perception test. Improved word perception was reported in 15 out of 20 patients without tinnitus following electrical stimulation of ears. In 11 out of 15 patients, the number of incorrect words significantly decreased, showing that electrical stimulation of ears improved word perception. Improved word perception was observed in 5 out of 8 patients whose tested ears were contralateral to treated ears while in 8 out of 12 patients whose tested ears were the same as treated ears. The present study suggests that electrical stimulation of ears improves word perception in hearing-impaired patients without tinnitus.

Aged

Evaluation of the tripolar electrode stimulation method by numerical analysis and animal experiments for cochlear implants.

We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.

Animals

A portable digital speech-rate converter for hearing impairment.

A real-time hand-sized portable device that slows speech speed without changing the pitch is proposed for hearing impairment. By using this device, people can listen to fast speech at a comfortable speed. A combination of solid-state memory recording and real-time digital signal processing with a single chip processor enables this unique function. A simplified pitchsynchronous, time-scale-modification algorithm is proposed to minimize the complexity of the DSP operation. Unlike the traditional algorithm, this dynamic-processing algorithm reduces distortion even when the expansion rate is only just above 1. Seven out of 10 elderly hearing-impaired listeners showed improvement in a sentence recognition test when using speech-rate conversion with the largest expansion rate, although no improvement was observed in a word recognition test. Some subjects who showed large improvement had limited auditory temporal resolution, but the correlation was not significant. The results suggest that, unlike conventional hearing aids, this device can be used to overcome the deterioration of auditory ability by improving the transfer of information from short-term (echoic) memory into a more stable memory trace in the human auditory system.

Audiometry, Speech

Objective method to determine the contribution of the great toe to standing balance and preliminary observations of age-related effects.

The purpose of this study was to examine the relationship between toe pressure and tactile sensitivity in the great toe and to describe two newly developed measurements of postural stability. The subjects of the study were 21 healthy volunteers. The subjects were divided into two age groups, the young group (mean 21.0 +/- 1.6 years, 7 males and 6 females), and the elderly group (mean 71.4 +/- 2.8 years, 4 males and 4 females). The methods and materials used for the first experiment (balance test): The instrument for measuring standing balance was a force plate. Data were analyzed to provide two main variables: 1) body sway index (SI: mm) and 2) toe pressure (%BW/cm2). The subjects were asked to stand in a relaxed posture for 20 s. The variables of body sway were measured in four conditions: normal surface with eyes open or closed, and soft surface with eyes open or closed. Second experiment (tactile sense test): This experiment utilized a new system which was developed for measuring the tactile sensation. The tactile threshold value was measured with the subject seated in a chair, the back supported, and the hips and knees flexed at 90 degrees. The contactor pulled and pushed the toe longitudinally along its axis at a constant velocity of 1 mm/s. There were significant differences between the young and elderly groups in the tactile sense of the great toe (p < .001). No significant difference between age groups was found for postural sway while the subjects stood on the normal surface with eyes open; however, when they stood on the soft surface with their eyes open and closed, the elderly showed significantly more sway (p < 0.01) than the young. Moreover, the maximal great toe pressure in the elderly group was significantly greater than that in the young group. The results suggest that the reduced tactile sense, deprivation of visual information, and toe pressure weakness are all important factors associated with postural instability.

Adult

Proposal of a new auditory nerve stimulation method for cochlear prosthesis.

The stimulation electrodes of cochlear implants are covered by a lymph liquid with high electrical conductivity, which causes the transmitted information to be reduced by channel interaction. Even if this problem were solved, the stimulation regions may be discrete; therefore, there may be regions in which the electrode array cannot stimulate selectively. To solve these problems, we proposed a new auditory nerve stimulation method which we call the tripolar electrode stimulation method for cochlear implants. Our method stimulates using 3 adjacent electrodes selected from among the electrodes of the electrode array. The center electrode receives the currents emitted from the electrodes on both sides. We conducted animal experiments using this method. On the basis of the results we obtained, we concluded that our method may succeed in narrowing the stimulation region and continuously moving the stimulation site.

Animals

An experience of the usage of electrical tinnitus suppressor.

An electrical tinnitus suppressor based on the use of an extracochlear stimulator has been developed at Hokkaido University, Sapporo, Japan, and was implanted in 2 male and 2 female patients. Tinnitus improved in all patients because the auditory nerve was able to be stimulated at home whenever patients wanted treatment. Additional benefits reported after electrical stimulation of the cochlea included sound sleep, relaxation in all cases, and improved hearing acuity in Cases 1, 2, and 4. Minimal temporary complications, including habituation and ear drum perforation, were observed.

Adult

Analysis of toe pressures under the foot while dynamic standing on one foot in healthy subjects.

Dynamic balance is a crucial element in performing many activities of daily living. The one-leg stance test is a valuable test for balance impairment. The aim of the present study was to assess the relationships between body sway and toe pressure for dynamic balance test of one-leg standing on a perturbation platform. The subjects were 15 volunteers (six males and nine females, age = 21.1 +/- 1.8 years). The instrument used for evaluation of balance was the Balance System, whose software provides information on the subject's stance balance through calculation of two main variables: 1) body sway parameters (cm) and 2) peak pressure (percent of body weight/cm2) under the toes. The Balance System includes actuators which move the foot platform back and forth (+/- 40 mm perturbation at 0.25 Hz) at an average velocity of 20 mm/sec. The subjects were asked to balance on each leg for 20 seconds. The trials were repeated on the opposite foot after 5 minutes of rest. The dynamic postural control induced by low frequency perturbation in the anterior/posterior direction used the ankle strategy. Body sway was more significantly correlated with the peak anterior/posterior sway component than with lateral sway (p < 0.01). The peak pressure value of the great toe was significantly greater (p < 0.01) than the sum of the peak values of the other four toes for both sides. The study indicates the importance of the strength of the toes and somatosensory information from the sole and ankle during the dynamic one-foot standing balance as goals in rehabilitation for poor balance.

Adult

A study of electrical promontory stimulation in tinnitus patients.

Electrical promontory stimulation relieved tinnitus in 74 (57.4%) of 129 ears (112 patients). There was no significant difference in etiology of tinnitus, age, average audiogram, or tinnitus frequency between patients who responded to electrical stimulation and those who did not. Most patients who did not respond to the initial stimulation trial did not respond to the subsequent trials, suggesting that the initial response to treatment predicts the subsequent response. Patients who did not respond to repetitive treatment were supposed to be under severe stress.

Adolescent

Neural responses to electrical stimulation of the cochlea in guinea pigs.

A special bridge circuit was constructed to compensate stimulus artifact to determine the effects of an alternating current (AC) in the range of 3 to 20 kHz and direct current (DC) stimulation on the activity of cochlear nerve fibers. When AC and DC stimulation of the same fiber were compared, a greater current intensity was required to change the spike rate with AC stimulation than DC stimulation. While positive DC stimulation reduced activity, negative DC stimulation increased the spike rate. AC stimuli excited fibers in a manner similar to that observed with negative DC stimulation. Thresholds increased with stimulus frequency, suggesting that the effects of AC stimulation on the discharge rate are independent of the CF (characteristic frequency) of a fiber. The effects of short-time AC and DC stimulation on cochlear fiber activity lasted only during the stimulation, and the spontaneous activity did not significantly differ before and after electrical stimulation.

Animals

[Electroconduction system for implantable tinnitus suppressor].

The purpose of this study was to introduce the electroconduction system for an implantable tinnitus suppressor. This system is a modification of the extracochlear implant system, which was developed at Hokkaido University. This system consists of a stimulator and two coils. One of the coils is implanted inside the temporal bone and its size, including the current limiter, is 9 mm long, 6.4 mm wide and 6 mm thick. Another is contained in the plastic case which is used for hearing aids. The efficacy of conduction depends on the wave frequency. The most effective frequency was about 30 kHz. The maximum current required to relieve tinnitus is 100 microA when using this system. The heat emitted from the coil inside the case is so minimal at an intensity of 100 microA as to be negligible systemically. The electromagnetic coupling system works well for more than 4 months in saline.

Cochlear Implants

[A tinnitus case with an implanted electrical tinnitus suppressor].

An electrical tinnitus suppressor, which was developed at Hokkaido University, was implanted in a female tinnitus patient. She had suffered from bilateral chronic otitis media and her bilateral hearing was seriously impaired. The electrical tinnitus suppressor consists of a stimulator, a coil inside the plastic hearing aid case and an implanted coil in the mastoid. The auditory nerve is stimulated at home twice. Using the system, her hearing ability and emotion improved in addition to tinnitus suppression. Her hearing level and tinnitus also improved in the ear contralateral to the stimulated side.

Cochlear Implants

Recording eye movement during stepping in place with a CCD (charge-coupled device) imagesensor.

A new system for recording eye movements using a charge-coupled device (CCD) imagesensor in a video camera, in which less than 0.5 degree of horizontal and vertical eye movements can be recorded, was applied in 7 subjects. Eye movements were recorded while they stepped in place. We observed 5 normal subjects, a patient with horizontal and vertical oscillopsia during walking, and one with a chronic limp. In the normal adults, the amplitude of vertical eye movement was less than 0.5 degree, and the horizontal eye movement was less than 2 degrees. The mean amplitude of horizontal and vertical eye movements in the subject who limped was larger than that of normal subjects. The patient who complained of vertical oscillopsia during walking showed the largest amplitude of vertical eye movement among any subject tested. The vertical oscillopsia in the patient was due to the largest amplitude of vertical eye movement. This system for recording eye movements will be useful in analyzing the mechanism of gaze fixation during walking.

Adult