Search PubMed⌕ Search

Biomedical subjects

T H Lim

Publications and source records attributed to T H Lim.

At least 73 records · Page 4Linked to original sources

Usual interstitial pneumonia: relationship between disease activity and the progression of honeycombing at thin-section computed tomography.

The authors estimate the relationship between the progression of honeycombing and disease activity of usual interstitial pneumonia (UIP) by open lung biopsy specimen and ground-glass opacity on thin-section computed tomography (CT). Open lung biopsy specimens and the initial and follow-up thin-section CT of 29 patients with proven UIP are reviewed. Follow-up thin-section CTs were performed from 2 to 61 months (mean, 15.3 months) after biopsy. The interval between the initial CT and open lung biopsy was from 2 to 30 days (mean, 10.0 days). Areas of ground-glass opacity and honeycombing were quantified respectively on each CT slice by using a 0%-100% scale with 10% increments. Each open lung biopsy specimen was scored semiquantitatively for alveolar desquamation, alveolar septal inflammation, inflammatory airway narrowing, obstructive pneumonitis, and lymphoid nodules. Patients were classified into either a mild or severe activity group according to the median value of the pathologic score and the median value of the area of ground-glass opacity. The authors compared the progression of honeycombing on follow-up thin-section CT between the groups. The progression of honeycombing in UIP was significantly faster in the severe activity group than in the mild group according to the pathologic score (p = 0.003) and the area of ground-glass opacity (p = 0.0024). In patients with UIP, more active inflammation of the pulmonary interstitium results in faster progression of honeycombing in long-term follow-up.

Adult↗

Oblique MRI as a useful adjunct in evaluation of cervical foraminal impingement.

Magnetic resonance (MR) imaging is considered the gold standard for soft-tissue disease. The traditional MR imaging series uses axial and sagittal views. The purpose of this study was to demonstrate that oblique MR imaging provides valuable information about the cervical foramen not available from the conventional MR imaging technique. Ten asymptomatic individuals volunteered for MR imaging. Measurements were taken of height, width, and area for the nerves and foramen at the entrance and mid zones. Nerves were graded as normal, contacted, or deformed. Normal foraminal morphology in asymptomatic individuals and characteristics that compromise the space available for the nerve root were identified. Nerves with minimal or no contact had significantly greater foraminal widths than nerves with significant contact. Although there was a correlation between nerve contact and foraminal width, regression analysis did not demonstrate a correlation between disc height and foraminal size.

Adult↗

Cross cultural adaptation and validation of the Chinese Health Assessment Questionnaire for use in rheumatoid arthritis.

OBJECTIVE: The Health Assessment Questionnaire - Disability Index (HAQ), used as a disability and outcome measurement in rheumatoid arthritis (RA), has been validated in several languages, but not in Chinese. Our aim was to validate the Chinese version of HAQ (Chinese-HAQ) to suit the needs of Chinese speaking patients with RA in an Asian setting. METHODS: The original HAQ was modified in the context of Chinese culture and translated into Chinese by 2 translators aware of the objective of the questionnaire. The Chinese HAQ was self-administered by 42 patients with RA during their routine followup visit and one week later. RESULTS: The test-retest reliability assessed using Spearman's correlation coefficient was 0.84. Between dimensions measured in the HAQ, the highest test-retest reliability was observed for walking (Spearman correlation coefficient rs=0.80) and the lowest was for eating (rs=0.54). The internal consistency of the scale using Cronbach's alpha was high at 0.86. In terms of criterion validity, the Chinese-HAQ score was found to correlate well with American College of Rheumatology functional status (rs=0.501, p=0.01). The Chinese-HAQ scores also correlated well with markers of disease activity such as patient's perception of pain measured on a visual analog scale (rs=0.55, p < 0.001), grip strength in mm Hg (rs=-0.55. p < 0.001 ), and physician's assessment of disease activity (rs=0.59, p < 0.001). CONCLUSION: The Chinese HAQ is a reliable and valid instrument for studies measuring disability of patients with RA in Singapore.

Adult↗

A noninvasive, three-dimensional spinal motion analysis method.

STUDY DESIGN: A three-dimensional, noninvasive motion analysis method was developed by monitoring the orientation of the principal axes of each vertebra. OBJECTIVES: To develop a method of performing three-dimensional, noninvasive motion analysis of the spine using computed tomography data. SUMMARY OF BACKGROUND DATA: The concept of using principal axes of the moment of inertia tensor to measure the orientation and position of a rigid body has been applied to the wrist and subtalar joints, but has not yet been applied to the spine. METHODS: Scans were taken of two isolated vertebrae in various known positions. Centroids, area, moments, and product of inertia of each scan were determined using a commercial program. Custom software combined data using the parallel axis theorem to give three-dimensional data for each vertebra. Changes in the centroid and principal axes were used to calculate translation and rotation, respectively. RESULTS: The system accuracy was within 1.0 degree in rotation and 1.0 mm in translation. Some errors occurred in minor motions when a smaller number of scans were used. System resolution was 0.43 mm. CONCLUSIONS: A system has been developed capable of calculating three-dimensional spinal motion based on measurements of a series of computed tomography images. The system has an accuracy similar to that of current motion analysis methods, but future studies will be necessary to apply this system in vivo.

Cadaver↗

Laparoscopic assisted fusion of the lumbosacral spine. A biomechanical and histologic analysis of the open versus laparoscopic technique in an animal model.

STUDY DESIGN: An animal model for laparoscopic lumbosacral fusion. OBJECTIVES: To compare the biomechanical and histologic results of open to laparoscopic lumbosacral discectomy and fusion in an animal model. BACKGROUND DATA: Early clinical reports of laparoscopic lumbosacral fusions are encouraging, but animal experiments have not been reported. METHODS: Ten pigs (50-80 kg) were divided into two groups. Group 1 underwent an open anterior lumbosacral discectomy and fusion at L7-S1 using autologous bone graft and a titanium MOSS (DePuy Motech) cage. Group 2 was identical to Group 1 except that a laparoscopic technique was used. The animals were killed at 3 months, and the lumbosacral spines were harvested for biomechanical and histologic testing. RESULTS: Estimated blood loss and average length of operation, respectively, for the two groups were: Group 1, 50 mL, 2 hours 50 minutes; and Group 2, 40 mL, 3 hours 40 minutes. There were no perioperative or postoperative complications in either group. Motion analysis results showed less motion in lateral bending, flexion, and extension than in the intact specimen in both groups. Tensile testing showed that the stiffness was significantly greater in the open group than in the laparoscopic group (P < 0.004). Histologic examination showed a less extensive discectomy and less bone growth in the implant in the laparoscopic group. Inadequate decortication of end-plates occurred in two animals who underwent laparoscopy. CONCLUSIONS: Although lumbosacral discectomy and implant insertion can be performed using the laparoscopic technique, the construct may not have the same biomechanical strength as that attained with the open procedure. Laparoscopic-assisted lumbosacral fusion surgery requires additional investigation before it is widely used in clinical situations.

Animals↗

Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model.

STUDY DESIGN: Fresh calf lumbar spines were used to perform flexibility tests in multiple loading directions to compare the stabilizing effects of anterior and posterior rigid instrumentations. OBJECTIVE: To compare the biomechanical flexibility of anterior and posterior instrumentation constructs using an unstable calf spine model. SUMMARY OF BACKGROUND DATA: Unstable burst fractures of the thoracolumbar spine can be managed anteriorly or posteriorly. Controversy persists, however, on the merit of anterior fixation versus that of posterior fixation in terms of how much stability can be achieved. METHODS: Fifteen fresh calf spines (L2-L5) were loaded with pure unconstrained moments in flexion, extension, axial rotation, and lateral bending directions. After removal of L3-L4 disc and endplates to create an 1.5-cm anterior and middle column defect, testing was performed on five specimens after anterior Kaneda rod fixation, anterior University Plate fixation, or posterior ISOLA pedicle screw fixation (AcroMed, Cleveland, OH). Testing was repeated after inserting a polymethylmethacrylate block to stimulate an interbody anterior graft with instrumentation. RESULTS: All fixation devices provided a significant stabilizing effect in flexion and lateral bending. In extension, all constructs except ISOLA (AcroMed) without graft were stiffer than the intact specimen. In axial rotation with no graft, only the Kaneda device significantly reduced the flexibility from that of the intact specimen. The interbody graft provided additional rigidity to the ISOLA (AcroMed) instrumentation construct in flexion and extension and to the Kaneda construct in lateral bending. There was no significant effect of grafting in axial rotation. CONCLUSIONS: A short, transpedicular instrumentation, such as ISOLA (AcroMed), provided less rigid fixation in flexion and extension without the anterior structural graft. The Kaneda rod and University plate with grafting provided a significant stabilizing effect in all directions compared with the intact specimen. When no graft was inserted, the Kaneda device was more effective in preventing axial rotation than the other devices. In lateral bending, the University plate provided more rigid fixation than the Kaneda device without grafting.

Animals↗

Effects of Bufo marinus skin toxins on human fetal extracorporeal blood vessels.

The effects of extracts of Bufo marinus toad skin toxin on human isolated umbilical arterial rings and the fetal vessels of perfused placentae were examined and compared with those of ouabain, an inhibitor of Na+/K(+)-ATPase. Umbilical artery rings and fetal vessels of the perfused placenta responded to extracts, or ouabain, with constriction which persisted after the removal of each agent. Extraction of the skin, using various solvents, revealed that the umbilical artery constriction was due mainly to the effects of water-soluble, polar compounds. Fractionation of a water extract and bioassay on the rat isolated aorta revealed maximum vasoconstrictor activity in a low mol. wt fraction. During Na+/K(+)-ATPase inactivation in the fetal circulation of the human placenta, by perfusion with K(+)-free Kreb's solution, reactivation of the enzyme by K+ infusion caused vasodilatation. This effect was inhibited both by water extracts of load skin and by ouabain. Thus, properties of some of the endogenous compounds in B. marinus skin resemble those of ouabain, by causing persistent constriction of human fetal blood vessels. A component of the vasoconstrictor response probably results from inhibition of vascular smooth muscle Na+/K(+)-ATPase, but it is likely that a contribution is also made by additional vasoconstrictor substances contained in B. marinus toxin.

Animals↗

Changing indications for penetrating keratoplasty: a newly developed country's experience.

PURPOSE: To study the changing indications for penetrating keratoplasty in Singapore and compare local indications with developed countries with established corneal graft programs. METHODS: A descriptive study of all penetrating keratoplasty cases performed in the Singapore National Eye Center over a 5 year period, from 1 January 1991 to 31 December 1995 using records of the Singapore Eye Bank registry. RESULTS: A total of 327 penetrating keratoplasties were performed. Bullous keratopathy was the indication in more than a quarter of all cases (26.3%). Aphakic bullous keratopathy (11.6%) and pseudophakic bullous keratopathy (11.3%) accounted for the majority of the bullous keratopathy cases. The other leading indications were regrafts (11.9%), corneal dystrophies (10.4%), traumatic scarring (10.1%) and keratoconus (9.8%). A higher proportion of aphakic and pseudophakic bullous keratopathy as well as regrafts was noted in this series compared to a previous report on corneal transplantation in the 1980s. A rising indication rate of pseudophakic bullous keratopathy, in conjunction with a declining indication rate of herpetic keratitis was observed over the 5 year study period. CONCLUSIONS: The indications for penetrating keratoplasty in Singapore appear to follow the trend seen in developed Western countries over the past few decades.

Adolescent↗

Pseudomyopia in a patient with blocked ventriculo-peritoneal shunt--a case report.

Accommodative spasm usually encompasses a classical triad of pseudomyopia, esodeviation and pupillary constriction. Accommodative spasm is most often psychogenic in nature; however, it may be associated with other organic diseases of which a rare cause is that of intracranial catheter complications. We report a case of dorsal midbrain syndrome with pseudomyopia in a patient with a blocked ventriculo-peritoneal shunt inserted for aqueductal stenosis. Clinical presentation was unusual in this patient as pseudomyopia occurred with exodeviation and without pupillary constriction.

Adult↗

Penetrating keratoplasty in the Singapore National Eye Centre and donor cornea acquisition in the Singapore Eye Bank.

We analyzed all penetrating keratoplasties performed in the Singapore National Eye Centre from 1 January 1991 to 31 December 1995, using records of the Singapore Eye Bank Registry, evaluating the indications, complications, causes of graft failure, visual outcome and graft survival rate. We also looked into donor cornea acquisition in the Singapore Eye Bank and its influence on the development of corneal transplantation in the Singapore National Eye Centre. A total of 327 penetrating keratoplasties were performed during the 5-year period. Bullous keratopathy was an indication in 26.3% of cases. Of these, aphakic bullous keratopathy accounted for 11.6% of all cases, while pseudophakic bullous keratopathy accounted for 11.3%. Other indications were regrafts (11.9%), corneal dystrophies (10.4%), traumatic corneal scarring (10.1%) and keratoconus (9.8%). Graft rejection was a complication in 20% of all cases. Of these, 40.9% led to graft failure. Other major complications were raised intraocular pressure (18%), epithelium-related problems (7.3%), wound dehiscence (4.3%), cataract (3.3%) and microbial keratitis (3.1%). The main causes of graft failure were graft rejection (8.2%), endothelial failure (2.4%), infection (2.4%) and glaucoma (2.1%). Of the 327 grafts, 40.3% achieved best corrected visual acuity of 6/12 or better; 70.8% achieved vision of 6/24 or better. The overall graft survival rate was 82.3% after a mean follow-up period of 2 years. Donor corneas for the penetrating keratoplasties were obtained from foreign eye banks as well as locally, with the local donation rate steadily increasing from 1991 to 1996, with the establishment of proper eye banking facilities and the Singapore Eye Bank. These results show that the indications and outcome of penetrating keratoplasty in the Singapore National Eye Centre are similar and comparable to that of other centres with established corneal grafting programmes. The establishment of the Singapore Eye Bank has ensured the proper co-ordination of acquisition of donor material which has been vital to the development of corneal transplantation in the Singapore National Eye Centre.

Adolescent↗

Ophthalmic manifestations in human immunodeficiency virus infection in Singapore.

The paper retrospectively reviews the spectrum of ophthalmic manifestations in human immunodeficiency virus (HIV) infection in Singapore between May 1995 and October 1996. One hundred and eighteen patients were examined for ocular abnormalities. Criteria for examination were 1) visual complaints, 2) absolute CD4 count of less than 50 cells/ul, 3) patients with acquired immunodeficiency syndrome-defining illness or 4) any relevant systemic illnesses which may have ocular involvement. Only 25 patients (21.2%) had visual symptoms. Eighteen patients (15.3%) had abnormalities associated with microvasculature. Forty-four patients (37.3%) had opportunistic infection involving the eye of which 37 were that of cytomegalovirus retinitis (CMVR). Seven patients (5.9%) had neuro-ophthalmic disorders. One patient presented with proptosis due to orbital lymphoma. Four patients (3.4%) had episcleritis and 3 patients (2.5%) had symptomatic dry eyes. It is still not known if episcleritis and dry eyes are associated with HIV infection or are coincidental. Fifty-one patients (43.2%) had no ocular pathology and remained so throughout the period of study. Nine patients (7.6%) had more than one pathology. The major cause of visual loss was due to ocular infections, with CMVR being most prevalent. Recognising the ophthalmic signs in HIV patients will facilitate early diagnosis. Prompt treatment of eye involvement can prevent or delay blindness, which is psychologically and functionally important to these patients.

AIDS-Related Opportunistic Infections↗

Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement.

STUDY DESIGN: A cadaveric study was done to analyze the dimensional changes in the spinal canal and intervertebral foramen of the lumber spine with flexion and extension movements. OBJECTIVES: To investigate the relationship between flexion and extension movements and morphologic changes in the spinal canal and the intervertebral foramen. SUMMARY OF BACKGROUND DATA: Previous studies have reported that the dimensions of the spinal canal and the intervertebral foramen may change significantly with motion. The purpose of this study was to assess the quantitative changes in the spinal canal and the intervertebral foramen with segmental flexion-extension movements. METHODS: Nineteen fresh cadaveric spines yielding 25 motion segments were used. The lumbar motion segments were frozen and then imaged in axial and sagittal projections by a computed tomography scanner. They were thawed then, and the motion segments were loaded to 5.7 Nm in flexion (13 motion segments) and in extension (12 motion segments) specimens. While in flexion or extension, the specimens again were frozen and imaged by computed tomography scan. The frozen specimens than were sliced using a cryomicrotome in the sagittal plane to study the dimensions of the intervertebral foramen. Eighteen other fresh cadaveric spines were sliced sagittally for study in the neutral position. RESULTS: The axial computed tomography scans showed that extension significantly decreased the canal area, midsagittal diameter, and subarticular sagittal diameter, whereas flexion had the opposite effects. The sagittal computed tomography scans showed that extension decreased all the foraminal dimensions significantly, whereas flexion increased all the foraminal dimensions significantly. The translational changes were associated with the bulging of the disc and the presence of traction spurs. The cryomicrotome sections showed the cross-sectional area of the foramen to be 12% greater for the flexion group and 15% smaller for the extension group than the cross-sectional area of the neutral group. Nerve root compression in the foramen was found to be 21.0% in neutral, 15.4% in flexion, and 33.3% in extension groups. CONCLUSIONS: The study supports the concept of dynamic spinal stenosis. In addition to static anatomic changes, careful dynamic studies may be required to evaluate better the central canal and the foramen.

Adult↗

The ideal amount of lumbar foraminal distraction for pedicle screw instrumentation.

STUDY DESIGN: A cadaveric study was performed to analyze the changes of foraminal dimensions of the lumbar spine and also to estimate the amount of foraminal distraction, achieved with pedicle screw instrumentation, that will create the greatest improvement in foraminal dimensions. OBJECTIVES: To establish the ideal amount of lumbar foraminal distraction using pedicle screw instrumentation and to investigate the changes of adjacent segments and lumbar lordosis with distraction maneuvers. SUMMARY OF BACKGROUND DATA: In patients undergoing fusions and instrumentation for foraminal stenosis, distraction of the lumbar spine may improve the dimensions of the intervertebral foramen. Results of previous studies have shown that anterior interbody distraction of the lumbar spine significantly increased the space in the lumbar foramen. No previous study has assessed the ideal amount of distraction, changes in the adjacent segments, or the effect on lumbar lordosis using posterior pedicle screw instrumentation. METHODS: Six fresh frozen human cadaveric spines from 15 to the sacrum were used. The ISOLA instrumentation system (Acromed Inc., Cleveland, OH) was applied using pedicle screws at L4, L5, and S1, L4-L5 and L5-S1 rods were contoured to the same degree of lumbar lordosis as in the specimen. The spine was potted in the upright position with the sacrum secured in the mold, and an axial load of 40 pounds was applied to the specimen. Radiographs were used to measure the posterior disc height, foraminal height, foraminal area, and lumbar lordosis. Two mm, 4 mm, 6 mm, 8 mm, and 10 mm of single level distraction were added to L4-L5 and L5-S1. The dimensions of the specimen were digitized and calculated after each distraction. RESULTS: The posterior disc height, foraminal height and foraminal area increased with distraction. The greatest incremental change in the foraminal area was noted at 6 mm of distraction. The L4-L5 foraminal area increased 22.6% at 6 mm of L4-L5 distraction, and the L5-S1 foraminal area increased 39.2% at 6 mm of L5-S1 distraction. With distraction above 6 mm, the foraminal change plateaued. The greatest decrease in lumbar lordosis was only 4.6 degrees and occurred at 10 mm of distraction. There was no significant effect of distraction on the foramina of adjacent levels. CONCLUSION: Posterior distraction using pedicle screws increased foraminal dimensions. The ideal amount of distraction on the rod, or the minimal amount of distraction necessary for improving foraminal dimensions, may be 6 mm using pedicle screw instrumentation.

Aged↗

Biomechanics of transfixation in pedicle screw instrumentation.

STUDY DESIGN: The biomechanical role of transfixation in pedicle screw instrumentation was investigated using flexibility tests and finite element analyses. OBJECTIVE: To assess the stabilizing effect of use and position of transfixators. SUMMARY OF BACKGROUND DATA: Transfixation is common in pedicle screw instrumentation, however, its biomechanical role and optimal position are not completely understood. METHODS: Specimens underwent nondestructive flexibility tests using a three-dimensional motion analysis system. Tests compared the intact spine with instrumentation with and without transfixators Rotational angles of the superior vertebra, resulting from the maximum moment of 6.4 Nm, were compared. Three-dimensional finite element models investigated transfixator position. Rotations of the superior vertebra were compared for cases with and without transfixators to determine the position providing the greatest stability. RESULTS: Biomechanical test showed that only axial rotational stability significantly improved with transfixators compared with instrumentation alone. Pimte element models predicted improvement in lateral bending and axial rotation with transfixators compared with the case with no transfixator. With one transfixator, the greatest improvement in axial rotation stability occurred with the transfixator at the proximal 1/4 position of the rods. When two transfixators were used, the optimal locations were with one transfixator in the middle and the second at the proximal 1/8 position. CONCLUSIONS: Transfixators improved the stabilizing effects of pedicle screw instrumentation. The greatest axial rotation stability was obtained with two transfixators; one in the middle and the other at the proximal 1/8 position of the longitudinal rods.

Animals↗

Sub-Tenon's versus retrobulbar anesthesia for cataract surgery.

BACKGROUND AND OBJECTIVE: A prospective, randomized, double-blind study was conducted to compare sub-Tenon's anesthesia with retrobulbar anesthesia. PATIENTS AND METHODS: One hundred six patients undergoing cataract extraction received either sub-Tenon's anesthesia (55 patients) or retrobulbar anesthesia (51 patients). The number of injections required, time until adequate akinesia was achieved, degree of pain experienced, and complications of the anesthetic injection were compared. The depth of the akinesia after sub-Tenon's injection was graded. RESULTS: There was no significant difference between the two study groups with respect to time of onset of adequate akinesia, the need for a second top-up injection, and the effectiveness of the akinesia. The sub-Tenon's injection group reported less pain during the anesthetic injection, as well as during the postoperative injection of subconjunctival gentamicin. CONCLUSION: Sub-Tenon's anesthesia is a safe technique that is comparable to retrobulbar anesthesia.

Aged↗

Occult lumbar lateral spinal stenosis in neural foramina subjected to physiologic loading.

PURPOSE: To measure the effect of extension, flexion, lateral bending, and axial rotation loads applied to the spine on the anatomic relationship of the spinal nerves in the neural foramen to the ligamentum flavum and the intervertebral disk, anc to determine the effect of disk degeneration on the response to loading. METHODS: Cadaveric lumbar motion segments were examined with CT and MR imaging, loaded with pure moment forces, frozen in situ, reexamined with CT, and sectioned with a cryomicrotome. The morphology of the intervertebral disks was classified on the basis of the appearance of the cryomicrotome sections. The neural foramina were classified as having no evident stenosis, as being stenotic, as having occult stenosis, or as showing resolved stenosis on the basis of the images and sections before and after loading. The stenotic and nonstenotic foramina were stratified by disk level, intervertebral disk classification, and type of loading applied. The effect of spinal level, disk type, and load type on the prevalence of stenosis was studied. RESULTS: On average, extension, flexion, lateral bending, and axial rotation resulted in the ligamentum flavum or intervertebral disk contacting or compressing the spinal nerve in 18% of the neural foramina. Extension loading produced the most cases of nerve root contact, and lateral bending produced the fewest cases. Each of the loading types resulted also in diminished contact between the spinal nerve and the intervertebral disk or ligamentum flavum in some cases. Disk degeneration significantly increased the prevalence of spinal stenosis. All foramina associated with advanced disk degeneration and half of the foramina associated with disks having radial tears of the annulus fibrosus either developed occult stenosis or were stenotic before loading. CONCLUSIONS: The study supports the concept of dynamic spinal stenosis; that is, intermittent stenosis of the neural foramina. Flexion, extension, lateral bending, and axial rotation significantly changed the anatomic relationships of the ligamentum flavum and intervertebral disk to the spinal nerve roots.

Adult↗

Prediction of fatigue screw loosening in anterior spinal fixation using dual energy x-ray absorptiometry.

STUDY DESIGN: A biomechanical study was performed to investigate a relation between the bone mineral density of the vertebral body and the number of loading cycles to induce fatigue loosening of an anterior vertebral screw. OBJECTIVES: The objective of this study was to investigate the potential usefulness of dual energy x-ray absorptiometry of measuring bone mineral density of the vertebral body in predicting the fatigue loosening of th anterior vertebral screw. SUMMARY OF BACKGROUND DATA: Loosening of the vertebral body screw is a well know failure in spinal instrumentation, and more commonly observed than pullout failure. The relation between bone mineral density and pullout strength of the screw has been investigated previously, but no studies are available on the fatigue loosening in anterior spinal fixation. METHODS: Bone mineral density was measured using dual energy x-ray absorptiometry and the screw loosening was produce by a cyclic loading in the cephalad-caudal direction. Screw loosening was defined as 1 mm displacement of the screw relative to bone, and the number of loading cycles to induce the screw loosening was obtained and statistically correlated with bone mineral density. RESULTS: There was a positive correlation between the number of loading cycles to induce screw loosening and bone mineral density (R = 0.8, P < 0.01). The average number of loading cycles to induce screw loosening was significantly less for specimens with bone mineral density < 0.45 g/cm2 compared to those with bone mineral density > or = g/cm2. CONCLUSIONS: These findings suggest that bone mineral density may be a good predictor of anterior vertebral screw loosening. Bone mineral density < 0.45 g/cm2 may be critical value of loosening of the anterior vertebral body screw. However, further biomechanical and clinical studies are required before using threshold value clinically.

Absorptiometry, Photon↗