Search PubMed⌕ Search

Biomedical subjects

T Fuerst

Publications and source records attributed to T Fuerst.

At least 37 records · Page 2Linked to original sources

Factors affecting broadband ultrasound attenuation results of the calcaneus using a gel-coupled quantitative ultrasound scanning system.

This study aimed to assess the factors that may influence the distribution and description of broadband ultrasound attenuation (BUA) and to identify specific criteria for diagnostic consideration when collecting BUA reference data. Two hundred Caucasian women (aged 20-79 years) without a history of atraumatic fractures or medicines known to affect bone metabolism were selected for this study. Medical and menstrual history, medication usage, family history of osteoporosis (FHO), physical activity, activities of daily living (ADL), dietary calcium intake, as well as smoking and alcohol consumption were obtained. Broadband ultrasound attenuation (BUA, dB/MHz) was determined in the right foot using a new gel-coupled ultrasound system. BUA was significantly associated with age (p<0.001), body weight (p<0.001), level of physical activity (p = 0.024) and dietary calcium intake (p = 0.023). Smoking, alcohol and coffee consumption and ADL were not associated with BUA (p>0.05). There were no differences in BUA (p>0.05) between those women who reported taking medications or had diseases (known to not affect bone metabolism), were using contraceptives, taking vitamin/mineral supplements and/or had traumatic fractures and their counterparts who did not report these characteristics. Premenopausal women with a FHO had significantly lower BUA values compared with those without a FHO (p = 0.013). When those participants with a FHO were removed from the sample, the peak BUA value was 1.1-4.4% higher and the variability (SD) was reduced by about 3.3-9.3% depending on which age range was used to define the peak BUA value. Consequently, an additional 4.5% of the population were classified as having a T-score <-2. Our results suggest that the impact on BUA of risk factors such as a FHO, body weight, physical activity and dietary calcium intake is similar to that on bone mineral density obtained by dual-energy X-ray absorptiometry (DXA), and thus provides further information on the comparability of quantitative ultrasound and DXA for assessment of risk of fracture. The criteria for calculating the T-score need further study to determine whether young adults with FHO should be included and what cutoff age range should be used in collecting peak values of quantitative ultrasound parameters.

Adult↗

Radiation exposure in bone mineral density assessment.

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue which leads to diminished biomechanical competence of the skeleton and low-trauma or atraumatic fractures. Due to increased awareness of the impact of osteoporosis on the elderly population, the use of bone densitometric techniques is becoming more widespread. Considerable progress has been made in the development of non-invasive methods for the assessment of the skeleton. While DXA and QCT are commonly used techniques, the popularity of other approaches such as RA, SXA and QUS is gaining grounds. QCT has an advantage over the other techniques in its ability to measure the true volumetric density of trabecular or cortical bone. We therefore present an overview of these current techniques for bone mineral density (BMD) measurements. In the second section we discuss the radiation doses incurred in BMD measurements by patients and methods for reducing patient and staff radiation exposure are given. Studies of radiation dose to patient from DXA confirms that patient dose is small (0.08-4.6 muSv) compared to that given by many other investigations involving ionizing radiation. Fan beam technology with increased resolution has resulted in increase patient dose radiation dose (6.7-31 muSv) but this is still relatively small. Carrying vertebral morphometry using DXA also incurs less radiation dose (< 60 muSv) than standard lateral radiographs QCT has radiation dose (25-360 muSv) comparable to simple radiological examination such as chest X-ray but lower than imaging CT. Radiation dose from other techniques such as RA and SXA are in the same order of magnitude as pencil beam DXA. For pencil beam DXA and SXA systems the time average dose to staff from scatter is very low even with the operator sitting as close as 1 m from the patient during measurement. However the scatter dose from fan beam DXA systems is considerable higher and approaches limits set by regulator bodies for occupational exposure.

Absorptiometry, Photon↗

An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen.

To measure the speed of sound (SOS), most quantitative ultrasound (QUS) devices use the transmission mode, whereby two transducers are placed on opposite sides of the sample. This mode is limited to a few specific skeletal sites because of the varying configuration of bone geometry and varying amounts of overlying soft tissue at most other sites. The aim of this study was to address the dependence of SOS measured along the sample on the thickness and composition of the bone sample. Bovine samples from mid-femur and trochanter, and perspex phantoms were used. We prepared the perspex samples in the shapes of blocks and cylinders to investigate the effect of wall thickness on SOS. The thickness of the blocks was decreased in decrements of 1 mm; a 22 mm diameter hole was drilled through the cylindrical samples and the hole size was gradually increased. The second configuration was also used with the bovine samples. For each experimental set-up five SOS measurements were acquired, with the probe aligned along the sample and a mean value computed. All measurements were taken with castor oil as the coupling agent, and in the cylindrical cases, the oil was used to fill the tube. The measurement precision determined as the root mean square coefficient of variation (RMSCV) was determined to be 0.14% and 0.65% for perspex and bovine samples respectively. The measured SOS on the perspex phantom (2760+/-4 m/s) was within the published values for bulk velocity. It was observed that for both perspex and bovine samples the SOS was independent of sample wall thickness greater than the wavelength (2.2 mm, 2.7 mm and 3.5 mm for perspex, trochanter and mid-femur respectively). The SOS decreased with sample wall thickness smaller than the wavelength in concordance with theoretical predictions. The SOS values obtained for bovine samples reflected either totally cortical (mid-femur) or a composite of cortical and cancellous bone (trochanter).

Animals↗

Validity of fan-beam dual-energy X-ray absorptiometry for measuring fat-free mass and leg muscle mass. Health, Aging, and Body Composition Study--Dual-Energy X-ray Absorptiometry and Body Composition Working Group.

The aim of the study was to examine the accuracy of fan-beam dual-energy X-ray absorptiometry (DEXA) for measuring total body fat-free mass (FFM) and leg muscle mass (MM) in elderly persons. Participants were 60 men and women aged 70-79 yr and with a body mass index of 17.5-39.8 kg/m(2). FFM and MM at four leg regions were measured by using DEXA (Hologic 4500A, v8.21). A four-compartment body composition model (4C) and multislice computed tomography (CT) of the legs were used as the criterion methods for FFM and MM, respectively. FFM by DEXA was positively associated with FFM by 4C (R(2) = 0.98, SE of estimate = 1.6 kg). FFM by DEXA was higher [53.5 +/- 12.0 (SD) kg] than FFM by 4C (51.6 +/- 11.9 kg; P < 0.001). No association was observed between the difference and the mean of the two methods. MM by DEXA was positively associated with CT at all four leg regions (R(2) = 0.86-0.96). MM by DEXA was higher than by CT in three regions. The results of this study suggest that fan-beam DEXA offers considerable promise for the measurement of total body FFM and leg MM in elderly persons.

Absorptiometry, Photon↗

An evaluation of a new gel-coupled ultrasound device for the quantitative assessment of bone.

Quantitative ultrasound (QUS) is now being accepted as a tool in the assessment of bone status. Most QUS devices measure broadband ultrasound attenuation (BUA) and speed of sound (SOS). A newly introduced device, the Acoustic Osteo-Screener (AOS-100), measures both SOS and an attenuation related parameter called the transmission index (TI) and provides a derived parameter called osteo sono-assessment index (OSI). The purpose of this study was to examine the reproducibility of this new device, compare the results with the UBA 575+ and evaluate the effect of using two platforms to compensate for different foot sizes on the measured values. 83 subjects aged 21-89 years, who gave informed consent, were recruited. Subjects were assigned to three different groups determined by age and health status. The short-term measurement precision (expressed as root mean square coefficient of variation) of SOS (0.13-0.16%) and TI (1.18-1.96%) was similar to and better than that obtained for the UBA 575+. Significant negative correlations were found between the differences in SOS measured with the two platforms (adaptors to adjust the position of the foot relative to the foot plate) and foot length (p < 0.0001). This implies that small feet are more influenced by the differences of measured location. All QUS parameters measured with the small platform were found to be significantly smaller than those with the large platform (p < 0.0001). The mean percentage differences were 0.6% in SOS, 2.8% in TI and 4.3% in OSI with the large foot platform giving larger value results. Proper use of the platforms resulted in more reproducible SOS and TI. This study demonstrated that the newly developed AOS-100 parameters TI and OSI were highly reproducible. This study also demonstrated that the use of an inappropriate platform can cause discrepancies in QUS readings and poor reproducibility.

Adult↗

Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women.

This study investigated the effect of different sized regions of interest (ROIs) on quantitative ultrasound (QUS) variables of the calcaneus. The effect on QUS of using a fixed ROI as opposed to an ROI adjusted for foot length was also assessed. Eighty Caucasian women, aged 50-57 yr (mean 53 +/- 2) who were healthy and within 0. 5-5 yr of the onset of menopause participated in this study. Using the QUS-1(trade mark) Ultrasonometer (Metra Biosystems, Mountain View, CA), we assessed broadband ultrasound attenuation ([BUA] and UBI-4, dB/MHz), the average transit time through the heel ([TTH], mus) and a multiple-factor index (UBI-4T = UBI-4/TTH, dB/[MHz. mus]). The QUS measurement results were calculated from three different sizes of ROI as well as one in a fixed location and one adjusted for foot size. Bone thickness, bone width, bone mineral content ([BMC], g/cm), bone mineral density area ([BMD(a)], g/cm(2)), and bone mineral density volume ([BMD(v)], g/cm(3)) were measured by single-energy photon absorptiometry. Lateral radiography of the foot was used to ensure the QUS scanning location in a subgroup. The results showed that there was a 1.4-5.9% difference in QUS parameters among different ROIs (p = 0.076-0.001). No significant differences between fixed and adjusted location were found regarding the mean values of QUS. The correlation between the fixed and adjusted locations was very strong, although there was a 12-42% unexplained variation. On the other hand, QUS in the size-adjusted ROI increased the correlation with BMC/BMD compared to the fixed QUS assessments. After controlling for body weight and height, a significant correlation between QUS and bone mass variables remained, and in some cases correlations became stronger. Lateral radiography showed that when using a fixed location to scan a large foot, the scanning area might be close to the bone edge, an area of higher BMD and potential acoustic artifacts. When scanning a small foot, the scanning area was confined to the middle of the calcaneus. Our results indicate that bone size has a modest effect on BUA. There is a better correlation with BMD when the measurement region is appropriately located in the calcaneus. This suggests that measurement location based on foot size may improve the accuracy of the measurements, resulting in good diagnostic sensitivity.

Bone Density↗

Factors influencing the speed of sound through the proximal phalanges.

The amplitude-dependent speed of sound (AD-SOS) in the proximal phalanges is reported to be sensitive to osteoporotic changes. We investigated the influence of bone thickness and cortical thickness on AD-SOS. Phantoms made of Perspex were designed to simulate different bone width (11-16 mm) and cortical thickness (3-7.5 mm). The phantoms were designed with two opposing flat and cylindrical surfaces. The effect of cortical thickness was examined by drilling holes (simulating the medullary canal) of different diameters (1-7 mm) in the middle of the Perspex cylinders. The effect of sample thickness was investigated on solid Perspex phantoms of varied lengths. The standardized precision errors of AD-SOS measurement in vivo and in vitro on volunteers and phantoms were 2.8 and 0.9%, respectively. AD-SOS was influenced by the bone width, cortical thickness, and location along the phalanx. A decrease in either cortical width or cortical thickness resulted in a decrease in AD-SOS. The effect is dependent on whether the contact surface is curved or flat. It is possible that a curved surface has a focusing effect on the wave through the porous core, whereas for a flat surface, the path of the waves might not pass through the center. When cortical thickness and bone width were expressed as a ratio, there was a linear relationship between this ratio and AD-SOS through the phantoms. AD-SOS was independent of thickness for samples greater than 11 mm.

Adult↗

Quantitative bone mineral assessment at the forearm: a review.

Bone mineral density and geometric properties of the human forearm can be measured to determine the amount of bone or bone loss at the scanning site and to predict the risk of forearm fractures. These forearm measurements are also used to estimate bone mass at remote anatomical locations and thereby estimate the risk for spine, hip and other fractures. The peripheral location of the human forearm, with its relatively small amount of surrounding soft tissue, improves the accuracy and the precision of bone mass measurement and has made this site an early choice for the assessment of a subject's bone mineral status. Furthermore, the anatomy of the human radius enables the examination of both cortical and cancellous bone. This review describes the procedures for non-invasive bone assessment at peripheral sites including some of the more recently developed systems dedicated to assessment of the distal radius. The accuracy, precision and normative values they provide are presented. Responses to different forms of therapies as well as the ability to discriminate or predict osteoporotic fractures are also assessed. Low radiation dose, comfortable and fast handling, moderate cost, and a strong association with the risk of non-spine fractures, promote the use of forearm scanning as a widely applied screening procedure for the detection of generalised osteoporotic bone loss. However, a higher accuracy of fracture risk prediction at the spine or at the hip can be achieved by a direct bone density measurement at these sites. The monitoring of treatment at the distal forearm appears to require a longer follow-up time due to its decreased responsiveness compared with such highly trabecular load-bearing sites as the spine and the proximal femur.

Absorptiometry, Photon↗

Ultrasound characterization of bone demineralization.

Quantitative ultrasound (QUS) assessment of bone may permit an assessment of bone properties currently not available by bone densitometry techniques. To explore the effects of the quantity of bone mineral on acoustic parameters, we carried out an in vitro study of the impact of demineralization on attenuation of ultrasound in trabecular bone. Ten fresh cubes of trabecular bone obtained from bovine distal femurs were progressively demineralized using formic acid solution. The progression of demineralization was controlled by monitoring the specimen bone mineral density (BMD) using dual x-ray absorptiometry (DXA). At five stages of demineralization-0% (baseline), 25%, 50%, 75%, and 100% (all mineral removed)-the US properties of the specimens were assessed (Walker Sonix UBA 575+). The US parameters investigated were broadband ultrasound attenuation (BUA) and ultrasound attenuation in bone (UAB). Both DXA and QUS measurements were made along the three orthogonal axes of each cube. Our results demonstrated significant variability in both BUA and UAB along the three principle axes of the cubes whereas BMD did not differ in the different directions. A strong but nonlinear correlation was found between BMD and US attenuation. A reduction in BMD to 50% of the baseline values resulted in BUA (UAB) reduction to 25% and 19%, respectively. A random effect model analysis supported a multiplicative relationship between BMD and the US parameters. US attenuation is a sensitive indicator of bone mineral changes with nonlinear dependence on bone mineral loss. Bone collagen structure reinforced by hydroxyapatite crystal accounts for fundamental US characteristics. Ultrasound attenuation associated with trabecular orientation is basically dominated by the mineral spread in a collagen framework.

Absorptiometry, Photon↗

How can we measure bone quality?

Osteoporosis is a systematic skeletal disease characterized by low bone mass and microarchitectural deterioration of bone tissue. This leads to diminished biomechanical competence of the skeleton and is associated with low-trauma or atraumatic fractures. In the past decade, considerable progress has been made in the development of methods for assessing the skeleton non-invasively, so that osteoporosis can be better managed. While dual X-ray absorptiometry (DXA) is still the preferred methodology, several limitations will be addressed. Another densitometric technique which is widely accepted for diagnosis of spinal osteoporosis is single energy QCT. Measurements of vertebral trabecular bone mineral density (BMD) demonstrate larger percentage decrements between vertebrally-fractured subjects and normal controls, and confer higher relative risks for vertebral fracture than either anteroposterior or lateral DXA measurements. As an emerging alternative to photon absorptiometry techniques, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non-invasive assessment of osteoporotic fracture risk in the management of osteoporosis. The attractiveness of QUS lies in the fact that indirect and in vitro experience has suggested that ultrasound may give information not only about BMD but also about architecture and elasticity. Whether or not combining QUS and DXA improve fracture prediction is still unclear and needs further analysis. Due to the growing evidence supporting the use of QUS in osteoporosis and the large number of QUS devices already on the market, a general clinical consensus on the application of QUS is urgently needed. Other techniques that are less widely used for the management of osteoporosis. For example, peripheral quantitative computed tomography, quantitative magnetic resonance (QMR) and magnetic resonance microscopy are promising tools for the evaluation of the skeleton. For example, the ability of QMR and high resolution magnetic resonance imaging has been explored and shows promise as a technique for assessing trabecular bone structure in osteoporosis.

Absorptiometry, Photon↗

Expression, characterization, and immunoreactivities of a soluble hepatitis E virus putative capsid protein species expressed in insect cells.

The hepatitis E virus (HEV) open reading frame-2 (ORF-2) is predicted to encode a 71-kDa putative capsid protein involved in virus particle formation. When insect Spodoptera frugiperda (Sf9) cells were infected with a recombinant baculovirus containing the entire ORF-2 sequence, two types of recombinant proteins were produced; an insoluble protein of 73 kDa and a soluble protein of 62 kDa. The 62-kDa species was shown to be a proteolytic cleavage product of the 73-kDa protein. N-terminal sequence analysis of the 62-kDa protein indicated that it lacked the first 111 amino acids that are present in the full-length 73-kDa protein. A soluble 62-kDa protein was produced without the proteolytic processing by inserting the coding sequence of amino acids 112 to 660 of ORF-2 in a baculovirus expression vector and using the corresponding virus to infect Sf9 cells. The two recombinant 62-kDa proteins made by different mechanisms displayed immunoreactivities very compatible to each other. The 62-kDa proteins obtained by both proteolytic processing and reengineering demonstrated much higher sensitivities in detecting anti-HEV antibodies in human sera than the antigens made from bacteria, as measured by enzyme-linked immunosorbent assay. The data suggest that the soluble 62-kDa protein made from insect cells contains additional epitopes not present in recombinant proteins made from bacteria. Therefore, the 62-kDa protein may be useful for HEV diagnostic improvement and vaccine development. The reengineered construct allows for the consistent large-scale production of the soluble 62-kDa protein without proteolytic processing.

Amino Acid Sequence↗

Advances in the noninvasive assessment of bone density, quality, and structure.

Recent advances in the development of methods to assess the skeleton noninvasively have contributed to screening for risk of osteoporosis, early detection of the disease, and effective monitoring of its progression and response to therapy. The capability now exists to evaluate the peripheral, central, or entire skeleton as well as the trabecular bone or cortical bone envelopes accurately and precisely, with the capacity to determine bone strength and predict fracture risk. In this article we examine the current and future capabilities of quantitative computed tomography (QCT), quantitative ultrasound (QUS), and magnetic resonance microscopy (muMR) to assess architectural and densitometric properties of the skeleton to enhance the prediction of fracture risk.

Female↗

Bone density and quality measurement using ultrasound.

Techniques for measuring bone mineral density have been widely accepted for the diagnosis and management of osteoporosis. These techniques are clinically feasible, and their fracture prediction capability has been proven in numerous studies. However, it has been demonstrated that bone strength and fracture risk are affected not only by the density of bone but also by other skeletal features including bone composition and microarchitecture. Available techniques for measuring bone mineral density have some disadvantages because they offer limited ability to assess bone quality, are relatively expensive, and use ionizing radiation.

Bone Density↗

Quantitative CT assessment of the lumbar spine and radius in patients with osteoporosis.

OBJECTIVE: We undertook this study to quantify the relationship between bone mineral assessments of the lumbar spine using quantitative CT (QCT) and of the radius using peripheral QCT (pQCT) and to test the sensitivity of both techniques in detecting changes in bone mass that are related to age and osteoporosis. SUBJECTS AND METHODS: Forty-two healthy premenopausal, 38 healthy postmenopausal, and 97 osteoporotic postmenopausal women were examined with pQCT of the distal radius and with QCT of the lumbar spine (L1-L4). The bone mineral density (BMD), bone mineral content (BMC), and a cross-sectional area of cortical bone were assessed at the distal radius. The BMD of trabecular and total bone and the BMC of total bone were assessed at the midvertebral bodies of the lumbar spine. RESULTS: In the healthy women, correlations of radial BMD with spinal trabecular and total BMD were modest (r = .39 and r = .49, respectively) but were higher for total BMC (r = .79). All correlations in osteoporotic women (r = .19 for trabecular BMD, r = .31 for total BMD, and r = .47 for total BMC) were lower than those in healthy women. For measurement of spinal bone mass in healthy women, trabecular BMD showed a higher correlation with age (r = .81) and a larger relative annual decrease (1.2%) than did total BMD (r = .75, .78%) or total BMC (r = .54, .55%). At the radius, the highest correlations with age were found for total BMC (r = .57, .53%), cortical area (r - .52, .67%), and cortical BMC (r = .48, .78%). Age-adjusted odds ratios for prevalent vertebral fractures were highest for total (4.5) and trabecular (4.4) spinal BMD. For radial measurements, odds ratios were highest for both total BMD (2.3) and cortical area (2.3). CONCLUSION: QCT of spinal trabecular bone showed the strongest capability for assessment of age-related bone loss and for discrimination of osteoporotic vertebral fractures. In comparison, pQCT of radial trabecular bone showed the weakest capability for these applications, and pQCT of radial cortical or total bone showed intermediate capability.

Aged↗