Search PubMed⌕ Search

Biomedical subjects

T Fleiter

Publications and source records attributed to T Fleiter.

At least 19 recordsLinked to original sources

Aspects of computer-aided detection (CAD) and volumetry of pulmonary nodules using multislice CT.

With the superb spatial resolution of modern multislice CT scanners and their ability to complete a thoracic scan within one breath-hold, software algorithms for computer-aided detection (CAD) of pulmonary nodules are now reaching high sensitivity levels at moderate false positive rates. A number of pilot studies have shown that CAD modules can successfully find overlooked pulmonary nodules and serve as a powerful tool for diagnostic quality assurance. Equally important are tools for fast and accurate three-dimensional volume measurement of detected nodules. These allow monitoring of nodule growth between follow-up examinations for differential diagnosis and response to oncological therapy. Owing to decreasing partial volume effect, nodule volumetry is more accurate with high resolution CT data. Several studies have shown the feasibility and robustness of automated matching of corresponding nodule pairs between follow-up examinations. Fast and automated growth rate monitoring with only few reader interactions also adds to diagnostic quality assurance.

Diagnosis, Differential↗

[Precision in standardized Iso-C-Arm based navigated boring of the proximal femur].

C-arm navigation is a new tool in computer assisted surgery. The aim of this study is to evaluate the accuracy of Iso-C-arm based drill holes in the proximal femur. In nine artificial proximal femura, two holes with an angle of 135 degrees and 100 degrees in relation to the shaft axis were drilled in the direction of the femoral head. The defined target of the 3.2 mm drillings was a 4 mm steel ball, which had previously been placed and fixed at the cranial center of the femoral head. All the drillings were standardized with a navigated drilling machine fixed to a frame which only allowed movement of the system in the direction of the drill. During navigation the positions of the drill before commencement and at the deepest point of the canal were recorded. After drilling all specimens were evaluated by CT, and the coordinates of the center of the start and the end of the drilled hole and the center of the ball were determined. Using vector calculation, the smallest distance between the straight line, defined by the center of the starting point and the end point of the drill hole, and the center of the ball was calculated. Additionally, the coordinates of the intersection between the perpendicular to the center of the ball and the straight line were determined (xv, yv, zv), to evaluate the direction of misplacement of the drilled canal in relation to the target. For the 135 degrees drill holes, a median of 2.5 mm for the smallest distance between the straight line, given by the center of the start and the end of the hole, and the center of the ball was investigated (range 1.6-3.7 mm). For the 100 degrees holes the median was 3.1 mm (range 1.8-4.2 mm). The main plane of deviation in all of the 135 degrees holes was posteriorly, whereas in the 100 degrees holes posterior deviation occurred in four cases, cranial in three cases, and in one case each caudal and anterior deviation occurred. In our opinion, the accuracy of fluoroscopy based navigation applied in the region of the proximal femur is sufficient and reproducible. This technique can be used for implant placement at the proximal femur in the future.

Equipment Design↗

[Computer-assisted surgery: developments and prospects in 2001. Results of a workshop at Schloss Reisenburg, 23-24 November 2000].

The progress in computer assisted surgery (CAS) is influenced by new technologies in imaging as well as by the input of the users. At present, CAS procedures are established in dorsal spine instrumentation, prosthetics and long bone surgery. Present status and future of CAS was a topic of an expert meeting at the Reisensburg castle. Imaging will speed up in the future using multi-detector techniques. C-arm navigation will gain more information using the 3D technology intraoperatively. CT based navigation procedures are standard in spine and will be established in pelvic surgery. CAS in robotics at the moment means the use of robot-assistance. A new concept is the modality-based navigated surgery, which can be used at various skeletal locations. Visualization of patient data will improve using 3D semi-transparencies with real time update. In the future it will be mandatory to find algorithms to fuse the different possibilities and techniques. A new concept of surgical training is necessary to teach CAS procedures. Therefore discussion must go on to improve these systems.

Arthroplasty, Replacement, Knee↗

[Computer assisted surgery, 2001 development and prospects. Results of a congress at Reisensburg Castle, 23-24 November 2000]].

The progress in computer assisted surgery (CAS) is influenced by new technologies in imaging as well as by the input of the users. At present, CAS procedures are established in dorsal spine instrumentation, prosthetics and long bone surgery. Present status and future of CAS was a topic of an expert meeting at the Reisensburg castle. Imaging will speed up in the future using multi-detector techniques. C-arm navigation will gain more information using the 3D technology intraoperatively. CT based navigation procedures are standard in spine and will be established in pelvic surgery. CAS in robotics at the moment means the use of robot-assistance. A new concept is the modality-based navigated surgery, which can be used at various skeletal locations. Visualization of patient data will improve using 3D semi-transparencies with real time update. In the future it will be mandatory to find algorithms to fuse the different possibilities and techniques. A new concept of surgical training is necessary to teach CAS procedures. Therefore discussion must go on to improve these systems.

Forecasting↗

Geometric changes in aortic endografts over a 2-year observation period.

PURPOSE: To report geometric changes in bifurcated aortic endografts observed over a 2-year follow-up period. METHODS: Twenty-two patients (21 men; mean age 68 years, range 57-83) with abdominal aortic aneurysms were treated with an endovascular stent-graft. Follow-up examinations included spiral computed tomographic scanning postoperatively and at 3, 6, 9, 12, 18, and 24 months after treatment. Geometric changes were measured using 3-dimensional reconstructed images in anteroposterior (AP) and lateral projections. Locations for the measurements were the proximal neck, the midportion of the endograft, and the graft limbs at the origin of the iliac arteries. RESULTS: Lateral changes predominated, demonstrating maximum angles on the side of the inserted left limb. For the proximal neck, the stent angle changed by a mean -0.71 degrees in the AP and 4.0 degrees in the lateral projection. At the midgraft, changes were -0.56 degrees for AP and 12.5 degrees for lateral. The right limb showed an angle of 6.43 degrees in AP and -0.43 degrees in lateral, whereas the left limb angles changed 1.38 degrees in AP and 11.71 degrees in the lateral plane after 2 years. There was no statistically significance difference in these changes from baseline. CONCLUSIONS: Aortic endografts are exposed to a significant amount of movement after insertion, but the resultant changes are very inhomogeneous, unpredictable, and ongoing even after 2 years. The most vulnerable location seems to be the attachment zone of the modular graft limb. These geometric changes might be one cause for late complications, including leaks and limb dislocations.

Aged↗

Thrombus formation in aortic endografts.

PURPOSE: To examine the incidence of intraprosthetic thrombotic deposits in aortic endografts. METHODS: Transfemoral implantation of tube or bifurcated stent-grafts was performed in 82 patients (75 men; average age 67.7 years, range 25-88) for treatment of aneurysms of the abdominal (n = 73) or thoracic (n = 9) aorta in a 3.5-year period. Patients underwent 3-phase helical computed tomographic (CT) examinations at 3-month intervals. The length and cross-sectional area of any thrombotic deposits were measured from axial and 3-dimensional CT images. RESULTS: Over a 12.1-month mean follow-up, intraluminal deposits of thrombotic material were observed in 19 (23.2%) patients, all with infrarenal endografts that were predominately of a bifurcated design. The first signs of thrombus formation occurred on average 7 months postoperatively (range 1 week to 20 months). In 16 patients, nonocclusive deposits of thrombotic material were seen in the aortic segment of the endograft; a graft limb was involved in 5 patients. Three graft limbs occluded owing to kinking; no thrombus was seen on CT scans taken prior to occlusion. In 3 cases the thrombotic deposits disappeared completely from the prosthesis lumen during follow-up. CONCLUSIONS: Based on this small experience, nearly 1 in 5 patients may experience some degree of intraluminal thrombus following endovascular treatment of aortic aneurysms. Whether the deposition of thrombus is influenced by the geometry of the aortic stent-graft or by flow conditions within the prosthetic lumen must be determined in future studies.

Adult↗

Vertebral body replacement with a bioglass-polyurethane composite in spine metastases--clinical, radiological and biomechanical results.

Metastatic spine lesions frequently require corpectomy in order to achieve decompression of the spinal cord and restoration of spinal stability. A variety of systems have been developed for vertebral body replacement. In patients with prolonged life expectancy due to an improvement of both systemic and local therapy, treatment results can be impaired by a loosening at the implant-bone interface or mechanical failure. Furthermore, early detection of a metastatic recurrence using sensitive imaging modalities like computed tomography (CT) and magnetic resonance imaging (MRI) is possible in these patients without artefact interference. The aim of our pilot study was to evaluate the clinical applicability and results of a new radiolucent system for vertebral body replacement in the lumbar spine. The system consists of bone-integrating biocompatible materials - a polyetherurethane/bioglass composite (PU-C) replacement body and an integrated plate of carbon-fibre reinforced polyetheretherketone (CF-PEEK) - and provides high primary stability with anterior instrumentation alone. In a current prospective study, five patients with metastatic lesions of the lumbar spine were treated by corpectomy and reconstruction using this new system. Good primary stability was achieved in all cases. Follow-up (median 15 months) using CT and MRI revealed progressive osseous integration of the PU-C spacer in four patients surviving more than 6 months. Results obtained from imaging methods were confirmed following autopsy by biomechanical investigation of an explanted device. From these data, it can be concluded that implantation of the new radiolucent system provides sufficient long-term stability for the requirements of selected tumour patients with improved prognosis.

Adult↗

[Possibilities of virtual gastrointestinal endoscopy].

Beside the technological development of the modalities, secondary image-reconstruction procedures are of increasing interest for diagnostic purposes and preoperative planning. Recently the simulation of endoscopic views--so called virtual endoscopy--has become available for presenting volume datasets. This new technique, usually based on CT and MRT data-sets, leads to new possibilities for examination of gastrointestinal organs and vasculature. Most interest has focussed on colon examinations, depending on a detailed knowledge of the technical procedure of the examination and additional experience of endoscopic techniques of the examiner. The procedures for the different parts of the gastrointestinal tract are explained.

Endoscopes, Gastrointestinal↗

[High-resolution virtual laryngoscopy based on spiral CT data].

This pilot study investigated the feasibility and clinical value of high-resolution virtual real-time laryngoscopy based on helical CT data sets. Nine patients with laryngeal pathology (three with tumors of the vocal cords, two laryngeal carcinomas, one with invasion of the larynx by thyroid carcinoma and six subglottic stenoses) underwent examination by helical CT at a collimation of 1 mm. Following acquisition, the images were processed at a workstation with standard visualization software, such that virtual endoscopy (VE) in real time was possible. The images were then compared with the findings of conventional endoscopy. Because of swallowing artifacts, reconstruction failed in 2 of 12 patients. None of the carcinomas of the vocal cords was recognized at VE or in the cross-sectional CT images. VE provided the correct diagnosis in 8 of 12 cases (laryngeal tumors, subglottic stenoses). Virtual laryngoscopy is capable of simulating the visual findings of endoscopy in cases of laryngeal tumors and subglottic stenoses. Small tumors of the vocal cords are not adequately visualized. The major problem affecting results is motion artifacts resulting from involuntary swallowing.

Aged↗

Coarctations of descending and abdominal aorta: long-term results of surgical therapy.

PURPOSE: Nonarteriosclerotic and nonarteritic descending and abdominal aortic coarctation (DAAC) is a rare disease with a great variety of morphologic findings. The additional affliction of renal and other splanchnic arteries often affords complex corrective procedures. We report on our single-center long-term experiences with operative treatment of this malformation. METHODS: Over a period of 21 years, 15 patients (10 female and 5 male patients; age range, 8 to 57 years) were operated on for DAAC. Six patients had additional stenoses of eight renal arteries, and three had splanchnic arterial obstructions. At 4 to 25 years after the operation, all surviving patients underwent a clinical and a spiral computed tomography examination. RESULTS: There was one intraoperative death due to exsanguination after the rupture of a poststenotic aneurysm of the infrarenal aorta. Fourteen patients were discharged free of symptoms. During follow-up, four repeated operations were necessary for renal arterial bypass stenoses or aneurysms. One late death occurred as the result of an unrelated disease. CONCLUSIONS: Complete operative correction of DAAC usually can be accomplished as a single-stage procedure with low morbidity and mortality rates. The reconstruction of all renal arteries is essential to cure hypertension. Consequent follow-up is recommended for detection of late postoperative complications.

Adolescent↗

Comparison of virtual and fiberoptic bronchoscopy.

Preoperative diagnostic procedures in the treatment of non-small-cell lung carcinoma (NSCLC) include fiberbronchoscopy (FBS) and CT scanning of the thorax and abdomen. The introduction of double-detector helical computed tomography has led to improved image resolution which allows three-dimensional reconstruction of the bronchial tree. A special computer simulation provides a virtual endoscopic view into the inner surface of the bronchial system. In order to determine whether the so-called virtual bronchoscopy (VBS) accurately reflects the anatomic situation of the bronchial tree, neoplastic lesion, and postoperative control of sleeve resections, we performed a virtual bronchoscopy in 24 patients with NSCLC and in 6 patients following sleeve resections and compared the results with the findings of fiberoptic bronchoscopy. An anatomic computer simulation of the bronchial tree was created in 100% of the investigated patients. Central tumor stenosis or occlusion was visualized by VBS as well as by FBS. In peripheral tumorous lesions VBS revealed the correct diagnosis in only 75%. VBS, however, enables viewing beyond the stenosis. FBS remains the gold standard in the endoscopic diagnostic procedures, showing not only airway patency but also mucosal changes in the vicinity of the tumorous lesion. VBS, however, gives further information about the poststenotic area in occlusive main bronchus stenosis. Furthermore, adequate control investigation of airway patency in patients following sleeve resections or stent implantation can be performed by VBS.

Bronchoscopy↗

[A new method in the determination of individual delay time in bolus application in spiral CT].

Helical-CT examinations, particularly CT angiography, require precise timing between the examination procedure and the individual dynamics of contrast medium distribution in the arteriovenous system of the patient. The necessary delay between contrast medium injection and onset of has usually been either estimated or determined by means of an additional helical CT examination. The present paper introduces a new technique which allows bolus analysis without an additional scan. Prior to a CT angiography with 10 patients, two techniques for bolus analysis (BA) were compared. Prior to diagnostic contrast medium enhanced examination, a native (BA I) and a dynamic (BA II) examination were performed. Ten seconds prior to the start of each examination, a 10 ml test bolus was applied with an injection flow rate of 3 ml/s. Both examinations lasted for 30 s. During BA I, increase in attenuation in the aorta was compared at different sites, during BA II consistently at the same site. Comparison of the individual peak times yielded a coefficient of correlation of r = 0.926. The median value for BA I was 18.4 +/- 5.4 s and 19.2 +/- 4.5 s for BA II. The difference between measurement of peak time was 1.2 +/- 1.16 s. This modified technique for bolus analysis during the primary native scan of the upper abdominal organs permits calculation of the required individual delay time between contrast medium application and scan start: no additional examination is required and the method can be performed with any helical CT unit.

Adult↗

Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations.

OBJECTIVE: Both helical CT and fiberoptic bronchoscopy are used in the staging of pulmonary tumors for therapeutic decision making. The improved resolution offered by helical CT has led to the clinical use of three-dimensional reconstruction techniques such as virtual bronchoscopy. We tested this new simulated endoscopic view of inner organ surfaces and compared it with corresponding fiberoptic examinations of the tracheobronchial system. SUBJECTS AND METHODS: Twenty patients with malignancies of the lung and mediastinum were examined with both virtual bronchoscopy and fiberoptic bronchoscopy. Both examinations were reviewed by radiologists and surgeons familiar with fiberoptic bronchoscopy. Virtual bronchoscopy was calculated and reconstructed from the cross-sectional images on a separate workstation. Stenoses and tumor infiltration were classified from the fiberoptic examination. These results were compared with the virtual bronchoscopy findings. RESULTS: Virtual bronchoscopy of diagnostic quality was achieved in 19 of 20 patients. High-grade stenoses were revealed equally well with virtual and fiberoptic techniques. Virtual bronchoscopy offered the advantage of being able to visualize areas beyond even high-grade stenoses. However, on virtual bronchoscopy discrete infiltration or extraluminal impression was not visible in five patients. In another patient, strong heart pulsation produced motion artifacts that prevented evaluation of the reconstruction. CONCLUSION: Virtual bronchoscopy represents a new noninvasive method for evaluating helical CT findings. In comparison with fiberoptic bronchoscopy, virtual bronchoscopy offers the advantage of being able to visualize areas beyond even high-grade stenoses. In addition to the limited view of fiberoptic bronchoscopy, extraluminal causes of lumen compressions can be analyzed in the cross-sectional images and evaluated together with the virtual representation. However, it was not possible to detect small infiltrations with virtual bronchoscopy. This new representation of helical CT data might be helpful for postoperative follow-up examinations, such as after stent implantation, and can be carried out without additional risk to the patient. Radiologists do need special fiberoptic bronchoscopy knowledge and experience with three-dimensional-reconstructions to differentiate between real stenoses and artificial stenoses that might be caused by pulsation artifacts.

Artifacts↗

[Atypical aortic coarctations in type I neurofibromatosis].

From 1971 through 1996, 16 patients were operated on for atypical aortic coarctation. Three of them (two women, 18 and 27 years old, one boy, 13 years old) had typical signs of neurofibromatosis type I (NF1). All had renovascular hypertension due to suprarenal and/or interrenal aortic stenosis. Two had additional bilateral renal artery stenoses, one with a poststenotic aneurysm. In all patients a thoraco-abdominal aorto-aortic bypass was implanted. The renal artery stenoses were bridged by two aorto-renal, a prothesio-renal, and a spleno-renal bypass. Only one kidney had to be explanted 13 years after revascularization for a recurring hilar aneurysm after ex-situ reconstruction was found to be impossible. At their last follow-up examination (at 16, 14, and 9 years) all patients were normotensive without medication and had normal serum-creatinine measurements. Angiography or spiral-CT done in all patients showed normal function of all bypasses. In literature we found another 27 patients with neurofibromatosis operated on for atypical aortic coarctation. In these young and otherwise healthy patients, even complex reconstructions can be performed with a low rate of complications and excellent long-term results. Surgical therapy of all relevant stenoses (at best in a single procedure) is necessary for complete relief of renovascular hypertension. Consequent follow-up is advised for the detection of possible late complications, especially after exclusion of aneurysms.

Adolescent↗

[Virtual cystoscopy based on spiral CT data].

Simulation of three-dimensional cystoscopy based on helical CT scan data in real-time in patients with tumours of the urinary bladder. In three patients with histologically confirmed carcinoma of the urinary bladder, a helical CT scan with double detector technology was carried out preoperatively. A native scan was first performed, followed by an examination in the early contrast medium enhanced phase. After adequate contrasting of the urinary bladder (30 minutes latency), further images were acquired. These data were transferred to a separate graphic computer workstation and reconstructed. The results were then compared with the cystoscopic and pathohistological findings. All tumours of the urinary bladder identified at fiberoptic cystoscopy were also visualised by virtual cystoscopy. The best reconstruction results were obtained from data acquired after the 30-minute latency period. Virtual cystoscopy represents an interesting option in helical CT scanning, which is able to visualise polypoid tumours of the urinary bladder. Its clinical relevance, however, must be demonstrated in studies with a larger number of patients examined.

Aged↗