Sodium measurements in the presence of paraproteins by four direct ISE methods and flame photometry compared.

Sodium was determined by flame photometry and by direct potentiometry using four different systems (Ektachem DT60, Corning 614, Orion 1020 and Nova-1) in serum samples from patients with normal proteins and paraproteins. Flame photometric and direct potentiometric differences (ISE-flame), showed the expected relationship with total protein whether or not the sample contained paraprotein, an exception being the Ektachem DT60 on normal protein. With the exception of the Ektachem DT60 with samples with normal protein levels, correlation between different ISE-flame estimates was good. Differences between direct potentiometric measurements are probably more attributable to efforts made by manufacturers to relate them to flame photometric measurements in 'normal samples', than to the volume occupied by increased protein content. The apparent lack of influence of protein on ISE-flame for the Ektachem DT60 was shown to relate to the original external reference electrode salt bridge used. A second study showed that changing this fluid to an equi-transferrant high salt content caesium chloride based reference fluid partially unmasked the protein effect.

Electrodes

Regional quality assessment of pH and blood gas analysers.

The performance of 41 pH and blood gas analysers in 20 hospitals was assessed using commercially available blood gas ampoules provided by seven manufacturers. The stability of the material and the effect of ambient temperature on Po2 was assessed. The overall mean values were outside the manufacturers' assigned values on eight out of 64 values. Using IL413 analysers as a basis for comparison, significant differences were found for Pco2 on ABL1, Corning 168 and 178 analysers and for Po2 on ABL1 and 2 and Corning 178. No significant differences were found for pH. Poor performers were identified in terms of imprecision. Analysers within or associated with clinical biochemistry departments gave better performance than those outside the laboratory. The five analysers that provided insufficient data for inclusion in the study were all situated outside the laboratory. Analysers from different manufacturers performed equally well provided they were used regularly and in accordance with manufacturers' instructions.

Blood Gas Analysis

Acceptance of values assigned to serum-based calibration materials.

A questionnaire sent to laboratories in the UK and Ireland elicited information on acceptance or otherwise of values assigned to serum-based calibration materials for 14 analytes. Overall, 33% of assigned values were changed by users. The reasons for change, together with the degree of magnitude and direction of change, were studied for each analyte. Unidirectional changes made to assigned values were related to particular batches and manufacturers. Detailed information is presented for protein (Beckman RIIC Ltd.) on Astras, and sodium, bicarbonate and bilirubin on SMACs and SMAs (Technicon Instrument Co. Ltd.).

Blood Chemical Analysis