Search PubMed⌕ Search

Biomedical subjects

T F Lang

Publications and source records attributed to T F Lang.

29 records · Page 2Linked to original sources

Advances in the noninvasive assessment of bone density, quality, and structure.

Recent advances in the development of methods to assess the skeleton noninvasively have contributed to screening for risk of osteoporosis, early detection of the disease, and effective monitoring of its progression and response to therapy. The capability now exists to evaluate the peripheral, central, or entire skeleton as well as the trabecular bone or cortical bone envelopes accurately and precisely, with the capacity to determine bone strength and predict fracture risk. In this article we examine the current and future capabilities of quantitative computed tomography (QCT), quantitative ultrasound (QUS), and magnetic resonance microscopy (muMR) to assess architectural and densitometric properties of the skeleton to enhance the prediction of fracture risk.

Female↗

Evidence for a rapid, direct effect on epithelial monolayer integrity and transepithelial transport in response to Salmonella invasion.

In cultured monolayers of high-resistance Madin-Darby Canine Kidney (MDCK) cells, infection with Salmonella typhimurium SL1344 resulted in a dose- and time-dependent increase in transepithelial conductance (Gt) and short-circuit current (Isc). There was a direct linear relationship between the S. typhimurium-induced increments in Isc and Gt suggesting that this early change in epithelial parameters is, in part, the result of a cellular conductance change most probably at the apical membrane. An additional wild-type S. typhimurium strain, SR11, and an invasion-deficient isogenic mutant SB111 carrying a non-polar mutation in invA were used to confirm that the S. typhimurium-induced change in epithelial electrical parameters is directly linked to the invasion process. The S. typhimurium-induced change in epithelial electrical parameters was markedly attenuated in Na+-free choline medium. Addition of piretanide (10(-4) M, basal side) failed to affect the increased epithelial conductance and Isc after a 40-min incubation with S. typhimurium. NPPB (5x10(-4) M) added to the apical medium reduced the S. typhimurium-stimulated Isc by 28%, but Gt was not significantly reduced. It is unlikely that the S. typhimurium-induced Isc is due to Cl- secretion. Staining of S. typhimurium-infected MDCK I monolayers with TRITC-phalloidin revealed marked alterations of F-actin; diffuse intracellular accumulations of F-actin corresponding to the presence of invading bacteria were observed by 15 min. After 60 min, prominent extrusions of the apical membrane corresponding to previously described "membrane ruffles" were noted. Marked accumulations of perijunctional F-actin in infected cells corresponded to contraction of the perijunctional actin ring at the apical pole. In adjacent cells marked distortion and stretch of the apical surface was evident. The invasion-deficient invA mutant SB111 failed to induce these morphological changes. These data demonstrate that S. typhimurium invasion induces increased transcellular conductance which does not result from stimulation of Cl- secretion but instead appears to be predominantly due to increased Na+ permeability. The increased membrane conductance is coincident with increased transepithelial inulin permeability indicating that the increment in Gt has an additional "paracellular" component. The S. typhimurium-induced alterations in epithelial parameters may be related to "membrane ruffling" and/or to the accompanying changes in cell shape.

Animals↗

Iterative concurrent reconstruction algorithms for emission computed tomography.

Direct reconstruction techniques, such as those based on filtered backprojection, are typically used for emission computed tomography (ECT), even though it has been argued that iterative reconstruction methods may produce better clinical images. The major disadvantage of iterative reconstruction algorithms, and a significant reason for their lack of clinical acceptance, is their computational burden. We outline a new class of 'concurrent' iterative reconstruction techniques for ECT in which the reconstruction process is reorganized such that a significant fraction of the computational processing occurs concurrently with the acquisition of ECT projection data. These new algorithms use the 10-30 min required for acquisition of a typical SPECT scan to iteratively process the available projection data, significantly reducing the requirements for post-acquisition processing. These algorithms are tested on SPECT projection data from a Hoffman brain phantom acquired with a 2 x 10(5) counts in 64 views each having 64 projections. The SPECT images are reconstructed as 64 x 64 tomograms, starting with six angular views. Other angular views are added to the reconstruction process sequentially, in a manner that reflects their availability for a typical acquisition protocol. The results suggest that if T s of concurrent processing are used, the reconstruction processing time required after completion of the data acquisition can be reduced by at least 1/3T s.

Algorithms↗

Noise propagation in SPECT images reconstructed using an iterative maximum-likelihood algorithm.

The effects of photon noise in the emission projection data and uncertainty in the attenuation map on the image noise in attenuation-corrected SPECT images reconstructed using a maximum-likelihood expectation-maximization algorithm were investigated. Emission projection data of a physical Hoffman brain phantom and a thorax-like phantom were acquired from a prototype emission-transmission computed tomography (ETCT) scanner being developed at UCSF. Computer-simulated emission projection data from a head-like phantom and a thorax-like phantom were also obtained using a fan-beam geometry consistent with the ETCT system. The simulation assumed a 99Tcm source, included collimator blurring but ignored photon scatter. For each phantom, a region of interest (ROI) at the centre of the reconstructed image was chosen for the purpose of noise analysis. In all cases, the mean value (m) in the ROI approached a constant value after approximately 20 iterations. The standard deviation (sigma) generally increased with the number of iterations. The ratio (sigma/m) was found to be inversely proportional to the square root of the total detected counts and proportional to the relative uncertainty in the attenuation maps. These two noise components contributed independently towards the noise in the reconstructed image. In the ETCT system employing an x-ray tube for attenuation map acquisition, the uncertainty in the reconstructed radionuclide distribution is limited mainly by photon noise in the emission projection data. Our results are expected to be generally applicable to other emission-transmission systems, including those using external radionuclide sources for the acquisition of attenuation maps.

Algorithms↗

Description of a prototype emission-transmission computed tomography imaging system.

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

Algorithms↗

Sex- and race-related differences in cross-sectional geometry and bone density of the femoral mid-shaft in older adults.

BACKGROUND: Femoral shaft fracture incidence increases in older adults and is associated with low-energy trauma. Apart from bone density, the distribution and size of bone contributes to its strength. AIM: To examine if bone geometry and density of the femoral mid-shaft in older adults differs by sex and race, we studied 197 White women, 225 Black women, 242 White men, and 148 Black men aged 70-79 years participating in the Health, Aging, and Body Composition study; a prospective cohort study in the USA. A secondary purpose of the study was to examine the association of site-specific muscle and fat to bone geometry and density. SUBJECTS AND METHODS: Subjects were community-dwelling and reported no difficulty walking one-quarter of a mile or climbing stairs. Mid-femoral volumetric bone mineral density (vBMD, mg cm(-3)), total area (TA), cortical area (CA), medullary area (MA), cross-sectional moments of inertia (CSMI: I(x), I(y), J), and muscle and fat areas (cm(2)) were determined by computed tomography (CT; GE CT-9800, 10 mm slice thickness). RESULTS: vBMD was greater in men than women with no difference by race (p < 0.001). Bone areas and area moments of inertia were also greater in men than women (p < 0.001), with Black women having higher values than White women for TA and CA. Standardizing geometric parameters for body size differences by dividing by powers of femur length did not negate the sex difference for TA and MA. Significant differences (p < 0.05) among the four groups also remained for I(x) and J. Mid-thigh muscle area was an independent contributor to TA in all groups (Std beta = 0.181-0.351, p < 0.05) as well as CA in women (Std beta = 0.246-0.254, p < 0.01) and CSMI in White women (Std beta = 0.175-0.185, p < 0.05). Further, muscle area was a significant contributor to vBMD in Black women. CONCLUSION: These results indicate that bone geometry and density of the femoral diaphysis differs primarily by sex, rather than race, in older well-functioning adults. In addition, site-specific muscle area appears to have a potential contributory role to bone geometry parameters, especially in women.

Aged↗

Assessment of trabecular structure using high resolution CT images and texture analysis.

PURPOSE: Our goal was to use high resolution (HR) CT images combined with texture analysis to investigate the trabecular structure of human vertebral specimens and to compare these techniques with bone mineral density (BMD) in the prediction of bone strength. METHOD: HR CT images with a slice thickness of 1 mm were obtained of 28 bone cubes. Four different groups of texture analysis techniques were used to assess these images. In addition, quantitative CT (QCT) was performed and elastic modulus (EM) was determined biomechanically. RESULTS: R2 between EM and BMD was 0.78 (p < 0.01). R2 values for EM versus most of the texture measures were also significant. Texture measures in addition to measures of BMD in a multivariate regression model significantly increased R2 up to 0.87. CONCLUSION: In an experimental setting, texture parameters calculated using HR CT images correlated significantly with EM. Combining texture measures with BMD improved the prediction of EM significantly.

Adult↗

Assessment of vertebral bone mineral density using volumetric quantitative CT.

PURPOSE: The purpose of this work was to determine the precision and diagnostic efficacy of bone mineral density (BMD) measures based on volumetric quantitative CT (QCT) of the spine. METHOD: Volumetric CT scans of L1 and L2 (GE-9800Q; 80 kVp, 140 mAs, 3 mm slices) were acquired in a cohort of 62 osteoporotic women (mean age 70.4 years, T(DXA hip or spine) < -2.5), of whom 20 had vertebral fractures and 42 were nonfractured control subjects. An image analysis technique delineated trabecular, cortical, and integral regions in reference to a vertebra-fixed coordinate system. We computed precision values and fracture control differences for these new regions and for single-slice QCT and dual X-ray absorptiometry (DXA) measures synthesized from the volumetric data. RESULTS: Volumetric trabecular BMD showed higher precision (1.3%) than the synthesized single-slice measures (2.1-2.8%). Volumetric and single-slice trabecular BMD showed equivalent decrements between fractured and nonfractured subjects (17-19%), with integral BMD showing smaller and less significant differences (7-8%). CONCLUSION: Volumetric and single-slice QCT techniques are equivalent for vertebral fracture risk estimation, but volumetric techniques should be superior for monitoring therapy efficacy.

Absorptiometry, Photon↗