Measurement of 129Xe T1 in blood to explore the feasibility of hyperpolarized 129Xe MRI.

OBJECTIVE: The major obstacle to the use of 129-xenon (I = 1/2) as a new source of contrast in magnetic resonance is its low sensitivity. The hyperpolarized 129Xe-MRI technique using laser optical pumping of rubidium promises to resolve this problem. The potential of xenon-based MRI for the body tissues other than the lung air spaces depends on the 129Xe polarization lifetime (T1) in the blood at a magnetic field of commonly available clinical MRI systems. MATERIALS AND METHODS: Xenon with natural abundance of 129Xe (26%) was dissolved in human blood and studied at 36 degrees C in a 2.35 T 40 cm bore MRI spectrometer (27.6 MHz). Zeeman relaxation (T1) of six blood samples was measured by the progressive saturation method for periods of 4-8 h each. RESULTS: NMR spectra revealed two peaks at 216.0 ppm (A) and 194.0 ppm (B) relative to the xenon gas above the blood volume. Assignment and 129Xe T1 values were 4.5 +/- 1 s for red blood cells (A), 9.6 +/- 2 s for plasma (B) and 11.9 +/- 1.6 s for xenon gas at atmospheric oxygen pressure. Xenon dissolved in distilled water appears at 189.8 ppm and has T1 = 26.3 +/- 1.4 s. CONCLUSION: These relaxation times, though shorter than expected, are comparable to the transport time of blood, and are long enough to encourage use of hyperpolarized xenon for MRI studies in tissues, in addition to lung.

Humans↗

Alignment of volume MR images and high resolution [18F]fluorodeoxyglucose PET images for the evaluation of patients with brain tumors.

PURPOSE: The goal of the study was to investigate the use of automated registration techniques for interpretation of volume MR and high resolution FDG-PET images that were obtained from patients with brain tumors. METHOD: Twenty-one patients with brain tumors were studied on one or more occasions using MRI and high resolution FDG-PET. The data were aligned using automated volume- and surface-matching algorithms. Composite images comprising the resliced pre- and postgadolinium spoiled GRE, T2-weighted SE, and PET data were constructed to correlate intensities of regions on the PET images with regions that corresponded to normal gray matter, white matter, and gadolinium enhancement. RESULTS: The accuracy of registration between the MR and PET images was estimated to be within 1-2 mm based upon the distance between surfaces of the outside of the head. In 12 of the 24 examinations, there were diagnoses of recurrent tumor, with only 5 of these exhibiting regions of higher FDG uptake than normal gray matter. For 19 of the 24 studies, the anatomic context provided by the registered MR images was found to be important in distinguishing recurrent tumor from necrosis based upon FDG uptake. CONCLUSION: The automated alignment was found to be an important factor in interpreting the high resolution PET images. This was particularly true for small lesions close to the cortex and for situations where FDG uptake had been reduced by prior treatment with radiation therapy.

Adult↗

Strategies for extraction of quantitative data from volumetric dynamic cardiac positron emission tomography data.

The ability of positron emission tomography (PET) to serve as a useful myocardial perfusion indicator is well established. We describe a methodology for obtaining reliable quantitative kinetic parameters from dynamic cardiac PET data. Reconstructed images of the myocardium are subdivided into three-dimensional volumes of interest which are used to obtain quantitative measures of myocardial perfusion over physiologically meaningful anatomical regions. The quantitation technique rigorously models the uncertainty of estimated parameters while compensating for effects such as patient motion and partial volumes to arrive at model parameters with well-established confidence intervals.

Coronary Angiography↗