Search PubMedSearch

Biomedical subjects

T Estlander

Publications and source records attributed to T Estlander.

At least 19 recordsLinked to original sources

Occupational IgE-mediated asthma, rhinoconjunctivitis, and contact urticaria caused by Easter lily (Lilium longiflorum) and tulip.

BACKGROUND: We report on IgE-mediated asthma, rhinoconjunctivitis, and contact urticaria to two Liliaceae plants, tulip and Easter lily (Lilium longiflorum), diagnosed in a floral shop worker. METHODS: Occupational asthma was diagnosed according to patient history, PEF monitoring, and a work-simulating provocation test. Flower-specific IgE was studied, and RAST inhibition tests were performed. RESULTS: Skin prick testing showed positive reactions to tulip, Easter lily, and chrysanthemum. Total IgE was 180 kU/I, and specific IgE to tulip was 2.6 and to Easter lily 6.5 kU/I. In the RAST-inhibition test, no cross-reactivity was found. Occupational asthma was diagnosed by peak flow monitoring at work and at home, as well as specific inhalation challenge with Easter lily, with an immediate 18% reduction in PEF. In addition, contact urticaria and conjunctivitis were diagnosed. After a 9-year follow-up without exposure to lilies, the skin prick tests to L. longiflorum and tulip were still positive, but the specific IgE had disappeared. CONCLUSIONS: A case of IgE-mediated occupational asthma, rhinoconjunctivitis, and contact urticaria caused by L. longiflorum and tulip is presented. RAST inhibition tests indicated concomitant sensitization to the two Liliaceae plants.

Allergens

Occupational allergic contact dermatitis from unsaturated polyester resin in a car repair putty.

BACKGROUND: Unsaturated polyester (UP) resins are widely used as cements in car repair painting to produce a smooth surface before the final painting. We report two car painters with hand and face dermatitis who were sensitized to a UP resin used for car repair cements. METHODS: Patch testing with commercial substances and ingredients and extracts from UP resins was used to verify the sensitivity. RESULTS: Both patients showed an allergic patch test reaction to a UP resin. They also had an allergic patch test reaction to diethyleneglycol maleate (DEGM), an extract of a UP resin. CONCLUSIONS: Both patients had been patch tested elsewhere with negative results because UP resins had not been used for patch testing. Accordingly, patients with dermatitis who have been exposed to UP resins need to be patch tested with UP resins. The specific chemical causing allergic contact dermatitis in our patients was DEGM.

Automobiles

Patch-test reactions to plastic and glue allergens.

Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.

Acrylic Resins

Increase in occupational skin diseases of dental personnel.

Occupational diseases of dentists and dental nurses were compiled from the Finnish Register of Occupational Diseases. The cases were recorded during 3 3-year observation periods, namely 1982-1984, 1986-1988, and 1992-1994 (i.e., 9 observation years). The relative risk of developing occupational allergic contact dermatitis in different occupations was calculated from the statistics of the years 1986-1991, and was expressed as the age-standardized rate ratio (SRR). During the 9 observation years, the majority of registered occupational diseases of dentists and dental nurses were skin diseases (221/312; 70.8%), followed by occupational repetitive strain injuries (61/312; 19.6%) and occupational respiratory diseases (20/312; 6.4%). The incidence rate (IR) for allergic contact dermatoses/10,000 workers (contact urticaria included) increased from 26 (95% confidence interval (CI) 16-40) in 1982-1984 to 79 (95%, CI 64-97) in 1992-1994. The IR/10,000 of allergic contact dermatoses increased especially for dentists, from 5.4 (95% CI 0.7-19) in 1982 to 67 (95% CI 45-95) in 1992-1994. The increase of the IR/10,000 dental nurses was smaller: from 43 (95%, CI 26-66) in 1982-1984 to 87 (95% CI 67-111) in 1992-1994. There was no increase in the IR/10,000 cases of irritant dermatoses. The most common causes of allergic contact dermatitis were plastics, disinfectants and antimicrobials, rubber chemicals, and mercury/mercury salts. The most common causes of irritant contact dermatitis were detergents, wet and dirty work, plastic chemicals and antimicrobials. Currently, Finnish dentists have the highest risk and dental nurses have the 4th highest risk of any occupation for developing occupational allergic contact dermatitis: the risk was 6.4-fold (SRR 6.4) in dentists and 6.1-fold in dental nurses, as compared to the general working population. It is evident that safer acrylics and protective gloves, better product declarations and material safety data sheets, as well as more information about protective measures, including non-touch working techniques, are needed.

Confidence Intervals

Occupational respiratory hypersensitivity caused by preparations containing acrylates in dental personnel.

BACKGROUND: Allergic contact dermatitis caused by acrylate compounds is common in dental personnel; they also often complain of work-related respiratory or conjunctival symptoms. OBJECTIVE: The aim of the present study was to report the cases of acrylates induced respiratory hypersensitivity in dental personnel diagnosed in Finland during the last 6 years. METHODS: Occupational asthma, rhinitis, laryngitis and pharyngitis cases were diagnosed according to patient history, PEF monitoring, and a work-simulating provocation test. RESULTS: Twelve cases of respiratory hypersensitivity caused by acrylates diagnosed in dental personnel (six dentists and six dental nurses) in 1992-97 are reported. During this period one case of conjunctivitis and one of laryngitis have been published separately. Nine cases of occupational asthma, two rhinitis cases, and one laryngitis case were verified according to the challenge tests with dental acrylate compounds (acrylates, methacrylates and epoxy acrylates). Only three patients had positive skin-prick test reactions to common environmental allergens, and none reacted to acrylates in the skin-prick tests. Five patients had an elevated total IgE (>110 kU/L). PEF follow-up showed an occupational effect in all examined eight patients with diagnosed asthma. The mean duration of exposure to acrylates was 22 years, and the duration of respiratory symptoms 8 years. CONCLUSIONS: The results indicate that acrylates constitute an important hazard for dental workers. The mechanism of respiratory hypersensitivity is still unknown, and it is probably not IgE-mediated.

Acrylates

Active sensitization and occupational allergic contact dermatitis caused by para-tertiary-butylcatechol.

Para-tertiary-butylcatechol (PTBC) is a rare allergen which is used in the rubber, paint and petroleum industries. We present 9 patients who were sensitized to PTBC and examined at the Finnish Institute of Occupational Health (FIOH) between 1974 and 1995. 3 of the patients had been exposed to PTBC in their work. 2 of them also had allergic reactions to para-tertiary-butylphenol (PTBP)-formaldehyde resin and to PTBP. 5 of the patients became sensitized to PTBC from patch testing. PTBC was found to be one of the most common causes of active sensitization in our clinic. Accordingly, at the FIOH, the patch test concentration of PTBC was lowered to 0.25% and this lower concentration is recommended for general use.

Adhesives