Search PubMed⌕ Search

Biomedical subjects

T E Oh

Publications and source records attributed to T E Oh.

At least 91 records · Page 5Linked to original sources

Maternal and fetal levels of propofol at caesarean section.

Twenty women were given a bolus induction of propofol 2.0 mg.kg-1 for elective caesarean section. Induction to delivery times ranged from five to fourteen minutes. At delivery the maternal venous (MV) concentrations of propofol ranged from 0.53 to 1.48 micrograms.ml-1 umbilical vein (UV) 0.39 to 1.4 micrograms.ml-1 and umbilical artery (UA) 0.34 to 0.68 micrograms.ml-1 MV propofol concentrations were always higher than corresponding UV concentrations. The mean (95% confidence interval) UV/MV ratio was 0.65 (0.56-0.74) and the mean UA/UV ratio was 1.07 (0.99-1.15). Neither ratio was shown to be correlated with induction to delivery time. Distribution of propofol is rapid across the placenta and in the fetus. Apgar scores were higher with shorter incision to delivery times but were not correlated to umbilical levels of propofol.

Adult↗

Tubeless anaesthesia for microlaryngeal surgery.

An anaesthetic technique for laryngeal microsurgery is described and evaluated using intravenous propofol infusion and topical lignocaine with the patient breathing spontaneously without an endotracheal tube. Eighty adult patients divided into two groups according to their ASA status (Group A; 58 ASA I and II; Group B; 22 ASA III and IV) were analysed. Operating conditions were good in all but one case. Good anaesthesia was achieved in about 70% of patients. The requirement for propofol was less in Group B. Blood pressures decreased significantly following induction (P less than 0.001) but returned towards the preoperative values after ten minutes in Group A patients whereas the recovery was slower in Group B. Apnoea occurred on induction in about 40% of patients overall. PaCO2 showed a similar small increase in both groups. Oxygenation was adequate. The results show that propofol as an infusion in this simple tubeless technique is satisfactory. As the technique was considered potentially hazardous in those patients with upper airway obstruction, such patients were not included in this study.

Adult↗

The addition of fentanyl to epidural bupivacaine in first stage labour.

Epidural analgesia was studied in 100 healthy Chinese women with uncomplicated pregnancies in first stage labour. Patients were randomly allocated to receive 8 ml of one of the following five solutions: bupivacaine 0.125% with fentanyl 50 micrograms or fentanyl 100 micrograms, bupivacaine 0.25% plain, bupivacaine 0.25% with fentanyl 50 micrograms or fentanyl 100 micrograms. There was no difference in quality of analgesia among groups as measured by the reduction of visual analogue pain scores 20 minutes after the epidural dose. The duration of analgesia was similar among groups with the overall median duration being 105 minutes. There was no difference in method of delivery or neonatal Apgar scores. The least concentrated mixture providing good quality analgesia for the first stage of labour was the combination of bupivacaine 0.125% with fentanyl 50 micrograms.

Adult↗

The effect of H2 antagonists on duration of action of suxamethonium in the parturient.

Fifteen patients who underwent elective Caesarean section were given sodium citrate, either alone or combined with oral cimetidine or ranitidine, as antacid premedication. No significant differences in time to 25 or 50% recovery of the first twitch of a train-of-four after administration of suxamethonium were found between any of the groups. It is concluded that H2-antagonists do not significantly affect the duration of action of suxamethonium in parturients, in contrast to the findings of a study in nonpregnant patients.

Anesthesia, General↗

Oxygen therapy.

Explore the source record for details and available documents.

Humans↗

Ventilation--matching man, mode and machine.

Mechanical ventilation has a number of clinical applications but is used principally to maintain gas exchange in anaesthesia and cardiorespiratory failure. This paper will discuss the clinical applications of ventilators and various modes of ventilation.

High-Frequency Ventilation↗

Pharmacokinetics of ranitidine in critically ill patients.

The plasma pharmacokinetics of ranitidine (50 mg i.v.) have been studied in 17 critically ill patients in an intensive care unit. Measurements of gastric aspirate pH were also made in 16 of these patients. Ranitidine therapy was part of the patients' normal drug regimen. Ranitidine plasma concentration was measured by high performance liquid chromatography and appropriate polyexponential equations were fitted to concentration-time data to enable calculation of relevant pharmacokinetic parameters. Values of the volume of the initial dilution space (median = 89 ml kg-1) and volume of distribution at steady state (median = 1.54 l kg-1) were about 60% of corresponding mean literature values for healthy controls. Plasma clearance (median = 4.22 ml min-1 kg-1) and terminal half-life (median = 4.7 h) were about 2-3 fold less and 2-3 fold greater, respectively, than values for healthy controls. There was wide interpatient variation in all the pharmacokinetic parameters. Renal impairment was considered to be largely responsible for the low plasma clearance. Gastric aspirate pH was measured at 0, 1 and 7 h after ranitidine administration and 58% of samples were found to be above pH 4. Four patients had gastric pH values which were consistently below pH 4 despite average trough plasma ranitidine concentrations equal to or greater than those required for a 50% suppression of gastric acid secretion in normal volunteers.

Adult↗

PEEP and CPAP.

Positive end-expiratory pressure (PEEP) maintains airway pressure above atmospheric at the end of expiration, and may be used with mechanical ventilation or spontaneous breathing. CPAP, or continuous positive airway pressure, refers to spontaneous ventilation with a positive airway pressure being maintained throughout the whole respiratory cycle. PEEP/CPAP primarily improves oxygenation by increasing functional residual capacity, and may increase lung compliance and decrease the work of breathing. PEEP/CPAP may be applied using endotracheal tubes, nasal masks or prongs, or face masks or chambers to treat a wide range of adult and paediatric respiratory disorders. Complications associated with their use relate to the pressures applied and include pulmonary barotrauma, decreased cardiac output and raised intracranial pressure.

Airway Resistance↗

Newer modes of mechanical ventilatory support.

Recent modes of ventilatory support aim to facilitate weaning and minimise the physiological disadvantages of intermittent positive pressure ventilation (IPPV). Intermittent mandatory ventilation (IMV) allows the patient to breathe spontaneously in between ventilator breaths. Mandatory minute volume ventilation (MMV) ensures that the patient always receives a preset minute volume, made up of both spontaneous and ventilator breaths. Pressure supported (assisted) respiration is augmentation of a spontaneous breath up to a preset pressure level, and is different from 'triggering', which is a patient-initiated ventilator breath. Other modes or refinements of IPPV include high frequency ventilation, expiratory retard, differential lung ventilation, inversed ratio ventilation, 'sighs', varied inspiratory flow waveforms and extracorporeal membrane oxygenation. While these techniques have useful applications in selective situations, IPPV remains the mainstay of managing respiratory failure for most patients.

Humans↗

New generation ventilators.

Desirable features of new generation intensive care ventilators include the ability to ventilate a wide range of patient sizes, an uncomplicated control panel, an appropriate but not excessive variety of ventilatory patterns, adequate patient monitoring and alarm functions, and simplicity of cleaning and routine maintenance. Examples of currently available ventilators include the Servo 900-C, CPU-1, Engstrom Erica, Bear 5, Drager EV-A and Hamilton Veolar. The incorporation of microcomputer control into some of these ventilators has resulted in improved flexibility and a limited number of automatic responses to detected patient changes. However, the function of components provided to allow spontaneous ventilation, such as demand valves, requires considerable improvement. Current trends in ventilator design include further refinement of computer control and the provision of graphic displays showing the results of continuous sophisticated analysis of respiratory function. The extent to which these developments will prove clinically useful will require careful evaluation.

Critical Care↗

A comparison of continuous flush devices.

Six different makes of continuous flush device were compared for reliability of flow rate and ease of use. All of the devices tested were considered suitable for flushing of vascular pressure monitoring catheters. However, flow rates were considered too variable for control of drug infusions or flushing of intracranial pressure monitoring systems.

Blood Pressure Determination↗

Pharmacokinetics of cimetidine in critically ill patients.

Cimetidine disposition was studied after rapid (1 min) intravenous infusion in eight critically ill patients aged between 20 years and 77 years; one patient was studied on two occasions. Cimetidine dose was 300 mg in seven patients and 400 mg in the remaining patient. Arterial plasma cimetidine concentrations at the end of the infusion were very high and ranged from approximately 15-35 mg/l. Pharmacokinetic parameters displayed wide interpatient variability (coefficients of variation of 30-50%) and significant relationships emerged between some of these parameters and certain patient characteristics. Most notable, total systemic plasma clearance of cimetidine was directly related to estimated creatinine clearance (p less than 0.01). This relationship might prove to be a useful method of individualizing cimetidine dosage in critically ill patients.

Adult↗