Search PubMed⌕ Search

Biomedical subjects

T Creasy

Publications and source records attributed to T Creasy.

4 recordsLinked to original sources

Computer-assisted venous occlusion plethysmography in the diagnosis of acute deep venous thrombosis.

Suspicion of deep venous thrombosis (DVT) is a common reason for acute medical admission. The clinical diagnosis is difficult, and thus significant numbers are investigated and found to be normal. Provision of 24-h radiology is costly, and there may be a delay in investigation. We assessed computer-assisted venous occlusion plethysmography as a screening test for DVT, compared with standard radiology. The test has the advantage of being performed on the ward and if reliable would significantly reduce the number of radiological investigations required. We enrolled 215 consecutive patients presenting with the possible diagnosis of DVT, of whom 144 had technically adequate plethysmography results. Plethysmography had a sensitivity of 96% (95%CI 88-99%) and a negative predictive value of 97% (95%CI 91-99%). Patients excluded because of technically inadequate results were older (by a mean 7 years, p=0. 003). Computer-assisted venous occlusion plethysmography is a non-invasive method of rapidly screening for DVT which may be safely used as an initial screening test. The test is less useful in older patients, or patients unable to keep still for a period of 2 min.

Acute Disease↗

Caval umbrella causing obstructive uropathy.

A 49-year-old woman had a vena caval filters inserted having suffered multiple pulmonary emboli and a large upper gastrointestinal bleed. She re-presented five years later with loin pain and obstructive uropathy. She was found to have a right pelvi-ureteric obstruction due to inferior vena caval wall perforation from the vena caval filter.

Female↗

Arterial oxygen saturation during upper gastrointestinal endoscopy: influence of sedation and operator experience.

In order to compare the effects of Diazemuls and midazolam on arterial oxygen saturation during upper gastrointestinal endoscopy, 120 patients were randomly allocated to receive Diazemuls, midazolam, or normal saline. Endoscopy was performed by one consultant or one of four residents. Arterial oxygen saturation was monitored continuously during endoscopy by means of a Biox III pulse oximeter and ear probe. Oxygen saturation fell during endoscopy in all three groups, but no significant differences between the groups were detected at any stage of the procedure. When all groups were combined, there was significantly less desaturation when the consultant performed the endoscopy, and he was also significantly faster in carrying out endoscopy than the residents in each group. When an inexperienced resident was compared with one with at least 6 months of experience, there were significant differences in degree of desaturation, lowest value during endoscopy and tolerance score. It is suggested that the patient at risk of hypoxemia should, if possible, be endoscoped by an experienced endoscopist.

Clinical Competence↗