Computer processing of oxygen dissociation curves.

Oxygen dissociation curves (ODC) plotted by a semi-automatic analyzer are subsequently processed by a digital computer. This computer processing provides a complete determination of the ODC, hence offering more information than the single P50 generally used. The programs consist of three successive modules each with a higher degree of sophistication in the processing. The mass handling of the curves is also described.

Computers↗

Hemodynamic effects of lidoflazine during graded levels of bicycle exercise in normal subjects.

The hemodynamic effects of lidoflazine were studied in 12 young healthy subjects who received the drug orally (240 mg daily) for 8 weeks. During exercise after lidoflazine, heart rate (-2.6%), mean arterial pressure (-3.1%), arterio-venous oxygen (A-V02) difference (-3.4%), pressure rate product (-6.2%), and systemic vascular resistance (-8.6%) were significantly lower, while cardiac output (+5.4%) and stroke volume (+8.3%) were significantly greater. The maximal heart rate was lower after lidoflazine (-6 beats/min) but the maximal oxygen intake (VO2max) was not affected by the drug. The major hemodynamic effects of lidoflazine appear to be, on the one hand, an unexplained decrease in heart rate, and on the other, a decrease in systemic vascular resistance; the latter, which was expected from a vasodilator, could account for the greater stroke volume and contributes to the decrease of the pressure rate product. Lidoflazine has another unexplained effect, i.e. a decrease of the A-VO2 difference, suggesting a decreased peripheral extraction of oxygen at rest as well as during submaximal and maximal exercise.

Adult↗

Smoking and pulmonary diffusing capacity.

The pulmonary diffusing capacity (DLCO SB) and its two components, the capillary blood volume (Vc) and the diffusing capacity of the membrane (DMCO), expressed in absolute values and per litre of alveolar volume (VA'), were measured at rest and on exercise in healthy male smokers and nonsmokers of similar age and height, and with identical values for haemoglobin and spirographic data. DLCO, DLCO/VA', DMCO and DMCO/VA' are significantly lower in smokers, at rest and on exercise; the decrease in Vc and thetaVc/VA' in smokers at rest is due to a higher level of carboxyhaemoglobin. The decrease of DLCO, DLCO/VA', DMCO and DMCO/VA' is apparently not due to carboxyhaemoglobin or distributional factors but to anatomical lesions, probably of emphysematous nature, altering the pulmonary membrane. Formulas predicting DLCO, DMCO, Vc, DLCO/VA', DMCO/VA' and thetaVc/VA' in terms of age and height were established in smokers and in nonsmokers.

Adult↗

[Blood gas measurements and automatization (author's transl)].

The Corning 175, a fully automatic new blood-gas analyzer, was tested and compared with manual analyzers (Eschweiler-Radiometer). The precision was evaluated by means of tonometered bloods and precision gas mixtures. With the Corning 175 four parameters are measured: pH, PCO2, PO2, barometric pressure, and four computed: HCO3-, BE, oxygen content, oxygen saturation. These are automatically corrected for patient hemoglobin and temperature. A microprocessor controls the sequencing of all operations during the calibrations and the measurements and continuously checks the performances of the electrodes and the entire system. The operator part is limited to the introduction of blood. The advantages and the fiability of the automatism in clinical routine are described.

Autoanalysis↗