Miniature vibrating flow blood pump using a cross-slider mechanism for external shunt catheter.

The prototype of the miniature vibrating flow pump (VFP) is developed for the external shunt catheter. The cross-slider mechanism is applied to vibrate the tube, which causes the pumping effect. This mechanism results in successful development of the miniature and lightweight VFP. By the use of the prototype VFP, the experiment of the basic pump performance is made in detail based on the authorized procedure in the research field of fluids engineering. The typical H-Q curve of VFP, which is the relationship between the pump head and the flow rate, can be obtained. This result suggests that the miniature VFP developed here can be expected to be used as the booster pump for the external shunt catheter in clinical applications.

Arteriovenous Shunt, Surgical↗

Development of an implantable high-energy and compact battery system for artificial heart.

The purpose of this study was to demonstrate the feasibility of the use of an implantable, high-energy, and compact battery system for an undulation pump total artificial heart (UPTAH). The implantable battery system tested consists of six lithium-ion batteries in series, a charge unit, and a charge/discharge control unit. A lithium-ion battery is currently the best energy-storage device because it has more energy density, a better life cycle, and a smaller temperature rise than those of other secondary batteries. The performance of the implantable battery system was evaluated in an in vitro experiment using an electric load that simulated the UPTAH. Also, sufficiently reliable operation of a system for supplying energy to a UPTAH consisting of a transcutaneous energy transmission system (TETS) and an implantable battery system was confirmed in three experiments using goats. The results of the in vitro and in vivo experiments showed that the implantable battery system supplied sufficient current to the UPTAH for maintenance of physiological conditions in the goat with maximum rise in temperature to less than 43 degrees C.

Animals↗

Acute lymphoblastic leukemia accompanied by chromosomal abnormality of translocation (12;17).

This report concerns a female patient with B-precursor acute lymphoblastic leukemia with concomitant expression of CD13 and CD33. A rare chromosomal abnormality, t(2;17)(p13:q21), was detected in 70% of metaphases analyzed. A new subgroup of acute leukemia is proposed, consisting of our case and 12 reported cases with similar chromosomal abnormalities. This subgroup has a poor prognosis and a high incidence of biphenotypic characteristics.

Antigens, CD↗

One month survival with the undulation pump total artificial heart in a goat.

The undulation pump is a small continuous flow displacement-type blood pump. The undulation pump total artificial heart (UPTAH) is a unique implantable total artificial heart using undulation pumps. An adult female goat weighing 45.8 kg was used for implantation. The natural heart was replaced with the UPTAH under extracorporal circulation. The cardiac output (CO) was maintained to 100 ml/kg/min by controlling the right pump manually. To prevent lung edema, the left pump was controlled automatically to maintain the left atrial pressure below 20 mm Hg. The CO was maintained for 2 weeks. Thereafter, the CO gradually decreased. The goat suddenly died because of a brain stroke on the 31st postoperative day. At autopsy, the cavity of the left atrial cuff was almost occupied by the big pannus-like thrombus, which was thought to be the cause of death. Improvement of the atrial cuff is necessary to obtain longer survival and is being modified. No thrombus was found inside the pumps. However, temperature rise in a left motor was a problem. Improvement of the efficiency in a motor is necessary. Although many problems still remained, 1 month survival could be obtained with this unique implantable TAH using continuous flow displacement-type blood pumps.

Animals↗

[All-trans retinoic acid combined with low-dose cytosine arabinoside treatment for acute myelogenous leukemia with trilineage myelodysplasia--a case report].

AML with trilineage myelodysplasia (AML/TMDS) is recognized as having of poor prognosis due to its resistance to chemotherapy in comparison with de novo AML. An AML/TMDS patient who failed to respond to ordinary induction therapy achieved complete remission with combination therapy consisting of all-trans retinoic acid (ATRA) and low-dose Ara-C. No serious toxicity was observed. ATRA combined with low-dose Ara-C could be an alternative treatment for this kind of patient.

Antimetabolites, Antineoplastic↗

Analysis of hemodynamic response with 1/R control on biventricular bypass goat.

A conductance and arterial pressure based method (1/R control) to determine the cardiac output (CO) of a total artificial heart (TAH) was developed to provide a central nervous system with control over the output of TAH. In order to clarify the deference in hemodynamic response between natural heart and 1/R control, biventricular bypass was introduced in the goat. After 2 pneumatically driven sac-type blood pumps were connected to the natural heart, the pulmonary artery was totally clamped to acquire 100% right heart bypass, and the ascending aorta was stenosed to acquire about 60 to 90% left heart bypass; 1/R control was performed substituting the output of the right artificial heart for the CO. The results demonstrated that stable control could be achieved. A discrepancy was often seen between the pulse rate (PR) of the artificial heart and the heart rate (HR) in absolute value. However, the relative changes of PR were quite similar to that of HR for the most part, indicating that the responses of 1/R control were the duplication of natural cardiac responses in normal daily activity.

Animals↗

Development of a miniature undulation pump for the distributed artificial heart.

Research of the distributed artificial heart is important not only to acquire the means of individual organ perfusion but also to clarify the characteristics of the organ and the mechanism of blood distribution. To investigate the distributed artificial heart, the miniature undulation pump was developed. The outer diameter and the thickness of the developed pump were 38 mm and 11 mm, respectively. The priming volume of the pump was 3.2 ml. The total size including the motor unit was 38 mm in diameter and 32 mm in length. The total weight was 67.5 g. The total volume was 27.5 ml. The pump was driven with pulse width modulation by using a 1 chip motor controller. More than 5 L/min of continuous output could be obtained. The results showed that the developed miniature undulation pump system had enough performance for individual organ perfusion.

Biomechanical Phenomena↗

Using one rotary blood pump to produce separate pulsatile circulations in the upper and lower halves of the body.

Separate systemic circulations with pulsatile flow were obtained using 1 rotary blood pump as a left ventricular assist device. The outlet of the pump was divided into 2 conduits, 1 connected to the upper half of the body and the other connected to the lower half. An electric actuator that clamped the 2 outlet conduits alternately provided pulsatile flows. An in vitro experiment showed that the pulsatility phases of the upper and lower halves of the body were complementary with pulsatile flow, and an in vivo experiment showed that controlled flow distributions of continuous flows could be obtained.

Animals↗

Tumor-like splenic extramedullary hematopoiesis in a patient with myelofibrosis.

A 61-year-old woman, who was diagnosed in 1982 as having polycythemia vera, was admitted to our hospital in July 1998 because of a splenic tumor in an enlarged spleen due to myelofibrosis. As it was difficult to identify the etiology of the splenic tumor, partial splenectomy was carried out. The resected tumor proved to be an extremely proliferative lesion as the result of extramedullary hematopoiesis. Since it is difficult to diagnose the etiology of splenic tumor, the collection and analysis of reports of relevant cases may well facilitate diagnosis.

Diagnosis, Differential↗

Reverse motion of organelles with myosin molecules along bundles of the actin filaments in a Characean internodal cell.

We have visualized bundles of the actin filaments of a Characean internodal cell and investigated the sliding motion of organelles with myosin on the bundles. The investigation revealed that a power spectrum of the sliding velocity time series of the organelle has two remarkable peaks near 4 and 7.5 Hz. This suggests that myosin molecules attached to the organelle not independently but cooperatively produce the sliding force. Moreover, we have found that some organelles move in the opposite direction of their sliding motion for several hundred milliseconds along the bundles. The fluctuation analysis of that motion showed that a power spectrum profile of the reverse velocity time series almost agreed with that of the sliding velocity time series. This result suggests that the dynamics of the reverse motion is the same as that of the sliding motion.

Actin Cytoskeleton↗

Implantation of the undulation pump total artificial heart in the goat.

The undulation pump total artificial heart (UPTAH) was developed by using small-size continuous-flow displacement-type blood pumps (undulation pump). To clarify and improve the problems accompanied by the implantation in the chest, 14 animal experiments were performed on goats weighing 41.3-79.2 kg. The UPTAH could be implanted in the chest of all goats and was driven with a modulation pulsatile mode. The first problem was the atrial suction effect. This problem could be prevented to some extent by developing the soft disk and by improving atrial cuffs. An automatic detection and releasing of the atrial suction effect was also tried. The next problem was acute lung edema accompanied by the postural change of the animal. Development of the automatic control of left atrial pressure could prevent this problem. Small blood leakage from a pinpoint hole in the seal membrane was the next problem. Improvement of the manufacturing procedure of the membrane prevented this. With these improvements, a 10 day survival could be obtained with this unique implantable total artificial heart.

Acute Disease↗

Present status of the total artificial heart at the University of Tokyo.

At the University of Tokyo, various types of total artificial heart (TAH) systems have been studied since 1959. At the present time, 2 types of implantable TAH have been developed. One is an undulation pump TAH (UPTAH) and the other is a flow transformed pulsatile TAH (FTPTAH). Using the UPTAH, 14 cases of implantation were performed in goats and 10 days' survival obtained. The new type of FTPTAH is under a prototype study. To prevent ring thrombus, a polyurethane membrane valve, a jellyfish valve, has been developed. The longest in vivo experiences with this valve in the TAH blood pump have been 312 days in the left side blood pump and 414 days in the right side blood pump. Conductance and arterial pressure based control (1/R control) can realize the physiological control of the TAH. Using 1/R control, 532 days of survival could be obtained in a goat with a paracorporeal TAH. The technique required to apply this control method to a implantable TAH is under development. We have proposed a new 5 year research project of the implantable TAH entitled "Comprehensive Basic Research on the Development of a Japanese Original Implantable Total Artificial Heart" to The Ministry of Welfare.

Animals↗

[Dorsal root identification using spinal endoscopy and electro-physiology].

We aimed to develop a method of accurately identifying the dorsal root for the corresponding peripheral afferent nerve under endoscopic observation. We developed an endoscope with an external diameter of 1.8 mm. After small laminectomy on the lower thoracic vertebrae, we inserted this endoscope carefully into the epidural and then subarachnoid spaces. We observed structures in these spaces with the endoscope. We tried to determine the spatial relationship between these electrodes and dorsal root. After identifying each space, we inserted two electrodes into the visualized space to record evoked potentials; a bipolar electrode (protocol 1) and a catheter-type eight polar electrode (protocol 2). Each pole could be distinguished by marks. To stimulate peripheral nerves, we inserted needle-type electrodes into Th 10, 11 and 12 intercostal nerves. We attempted to record potentials from dorsal surface of the cord generated by intercostal nerve stimulus. Protocol 1: We moved the position of the bipolar recording electrodes between Th 9 and L 1 by 1 cm increment, and obtained evoked potentials correspondingly. Protocol 2: We chose the neighboring pairs of poles sequentially from the tip of the catheter for bipolar recording. At the end of each experiment, we dissected the animal and checked the intercostal nerve originating from the root. With the endoscope, we could clearly observe structures in the epidural and subarachnoid spaces. We could record evoked potentials from the dorsal spinal cord with the electrodes located either in epidural or in subarachnoid spaces. Shapes of evoked potentials changed characteristically according to the relative position between the root and the electrode. The largest potentials were obtained when the electrode was nearest to the dorsal root, of which the peripheral nerve was being stimulated. By combining endoscopy with the electrophysiological technique, we could accurately identify the dorsal roots for the corresponding peripheral afferent nerves. This method may be used for the selective dorsal root blockade under the visual field.

Animals↗

Physiological control of a total artificial heart: conductance- and arterial pressure-based control.

To obtain a physiological response by a total artificial heart (TAH), while eliminating the hemodynamic abnormalities commonly observed with its use, we proposed the use of a conductance- and arterial pressure-based method (1/R control) to determine TAH cardiac output. In this study, we endeavored to make use of a variable more closely tied to central nervous system (CNS) efferents, systemic conductance, to provide the CNS with more direct control over the output of the TAH. The control equation that calculates the target cardiac output of the TAH was constructed on the basis of measurement of blood pressures and TAH flow. The 1/R control method was tested in TAH-recipient goats with an automatic method by using a microcomputer. In 1/R control animals, the typical TAH pathologies, such as mild arterial hypertension and substantial systemic venous hypertension, did not occur. Cardiac output varied according to daily activity level and exercise in a manner similar to that observed in natural heart goats. These results indicate that we have determined a control method for the TAH that avoids hemodynamic abnormalities exhibited by other TAH control systems and that exhibits physiological responses to exercise and daily activities under the conditions tested. The stability of the control and the complete lack of inappropriate excursions in cardiac output is suggestive of CNS involvement in stabilizing the system.

Animals↗

[Acute transformation of chronic myelomonocytic leukemia with t(1;3) (p36;q21) abnormality].

A 66-year-old man was given a peripheral blood test because of low grade fever. Leukocytosis was detected, and the blood and bone marrow findings were consistent with those of chronic myelomonocytic leukemia. Three months later the hematological findings were: WBC 58,800/microliter (19% blastoid cells, 22% monocytes), Hb 9.0 g/dl, and a platelet count of 116 x 10(4)/microliters. A bone marrow examination revealed the presence of 52.6% blastoid cells and dysmegakaryocytopoiesis, including micromegakaryocytes. Serum and urinary lysozyme levels were elevated. Karyotypic analysis detected t(1; 3) (p36;q21), but not major bcr/abl mRNA. The patient was given a diagnosis of acute transformation of chronic myelomonocytic leukemia. Despite treatment, he died about 3 months later. t(1;3) is occasionally observed in cases of myelodysplastic syndrome (MDS) and leukemia. Patients with t(1;3) often exhibit dysmegakaryocytopoiesis; furthermore, acute leukemia develops more readily in those who also have MDS. Cases of long-term survival are rare.

Aged↗

Development of the undulation pump total artificial heart.

The undulation pump is a small size continuous flow displacement type blood pump that has been developed for an artificial heart. Using undulation pumps, 2 types of implantable total artificial hearts (TAHs), the undulation pump TAH (UPTAH) type 1 (UPTAH 1) and UPTAH type 2 (UPTAH 2) were developed. Both UPTAHs were designed to be small enough to implant into the chest of a goat, the experimental animal. UPTAH 1 could be reduced in size to 75 mm in diameter and 78 mm in length. The weight was 520 g. UPTAH 2 could be reduced in size to 75 mm in diameter and 80 mm in length. The weight was 650 g. UPTAH 2 could be tested in an animal experiment using an adult female goat weighing 52.3 kg. The UPTAH 2 could be implanted successfully into the goat's chest with a good fit. The goat stood after the surgery and extubation and survived for 3 h and 40 min; thus, the potential of the UPTAH for a practical implantable TAH was demonstrated.

Animals↗

Use of a catecholamine sensor in the control of an artificial heart system.

An electrochemical sensor system to allow real-time measurement and feedback of catecholamine concentrations was developed for use in the control of artificial hearts. Electrochemical analyses were carried out using a carbon fiber working electrode, an Ag-AgCl reference electrode, and a potentiostat. The operating parameters of the pneumatically-driven artificial heart system were altered in accordance with the algorithm for changes in the catecholamine concentration. The minimum detectable concentrations of both adrenaline and noradrenaline in a mock circulatory system using a phosphate-buffered solution were approximately 1-2 ng/ml (10(-8) mol/L). An artificial heart control system utilizing this set-up performed satisfactorily without delay, although sensor sensitivity decreased when placed in goat plasma instead of a phosphate-buffered solution, due to the adsorption of various substances such as plasma proteins onto the electrodes. This study demonstrated the future feasibility of a feedback control system for artificial hearts using catecholamine concentrations.

Adsorption↗

A percutaneously accessible pulsatile left ventricular assist device: modified assist device type 5.

To provide percutaneous access, a new circulatory assist system was developed. We call this newly developed system the modified assist device (MAD). The system is composed of a sac-type blood pump and cannula. Inflow and outflow valves are mounted in the apex and at the side wall 10 cm from the apex of the cannula, respectively. During systole, the blood is sucked from the left ventricle through the inflow valve of the cannula connected to the blood pump, and during diastole, the blood is ejected to the root of the aorta through the outflow valve. In vitro and in vivo evaluations of the pump performance were performed. The maximum flow rate of 1.9 L/min was obtained in the mock circulatory system. In our animal experiment, effective systolic unloading and diastolic augmentation were observed by activation of this system during regular sinus rhythm. In conclusion, the MAD-5 is thought to be percutaneously accessible and increases systemic and coronary flow.