Search PubMed⌕ Search

Biomedical subjects

T Chatterjee

Publications and source records attributed to T Chatterjee.

At least 37 records · Page 2Linked to original sources

Percutaneous closure of patent foramen ovale in patients with paradoxical embolism: long-term risk of recurrent thromboembolic events.

BACKGROUND: Patients with a patent foramen ovale (PFO) and paradoxical embolism are at risk for recurrent thromboembolic events. This study investigated the long-term risk of recurrent thromboembolic events in patients with PFO and paradoxical embolism after percutaneous PFO closure. METHODS AND RESULTS: Since 1994, a total of 80 patients with PFO and at least 1 paradoxical embolic event (transient ischemic attack [TIA], cerebrovascular accident [CVA], peripheral embolism) have undergone percutaneous PFO closure with 5 different devices. There were 30 women and 50 men, with a mean age of 52+/-12 years. Sixty patients had only a PFO, whereas 20 patients had both a PFO and an atrial septal aneurysm. The implantation procedure was successful in 78 patients (98%). During 5 years of follow-up (mean, 1.6+/-1.4 years; range, 0.1 to 5.0 years), the actuarial annual risk to suffer a recurrent thromboembolic event was 2.5% for TIA, 0% for CVA, 0.9% for peripheral emboli, and 3.4% for the combined end point of TIA, CVA, or peripheral embolism. A postprocedural shunt was a predictor of recurrent paradoxical embolism (RR, 4.2; 95% CI, 1.1 to 17.8; P=0.03). The risk for recurrent thromboembolic events in patients with both atrial septal aneurysm and PFO was not significantly increased compared with patients with only PFO (RR, 1.0; 95% CI, 0.2 to 4.7; P=0.95). CONCLUSIONS: Percutaneous PFO closure appears to be a promising technique in the prevention of recurrent systemic thromboembolism in patients with a PFO after a first event. Prospective studies comparing percutaneous PFO closure with antithrombotic medications or surgery must define its therapeutic value.

Actuarial Analysis↗

Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale.

OBJECTIVE: During recent years, transcatheter closure has become an alternative to operations for the treatment of atrial septal defects and patent foramen ovale. However, this procedure may be unsuccessful or complicated and requires surgical treatment. METHODS: We retrospectively analyzed the outcomes of patients who needed surgical treatment after failed or complicated transcatheter closure of an atrial septal defect or a patent foramen ovale. RESULTS: Between April 1994 and March 1999, 124 patients were treated with transcatheter closure of an atrial septal defect or a patent foramen ovale at our institution. We report the results of 10 (8%) patients of this series who required operations after transcatheter closure attempts. In 8 of these 10 patients a significant shunt caused by malposition or dislocation of the device persisted, leading to surgical closure of the defect. In 2 patients injury of the femoral artery at the puncture site required surgical repair. In one patient the device had to be removed surgically from the iliac vein after retraction. One patient died of left ventricular perforation after dislocation of the device and several surgical attempts to close the left ventricular rupture. All other patients recovered well. CONCLUSION: An operation was required after transcatheter closure of an atrial septal defect or a patent foramen ovale in 8% of patients. After device complications, the atrial septal defect and the patent foramen ovale can still successfully be closed surgically with good results and low morbidity. However, serious complications like cardiac perforation may have a fatal outcome. Residual shunt, dislocation, or vascular complications are the most frequent problems that require surgical interventions.

Adolescent↗

Transesophageal echocardiography to evaluate success of transcatheter closure of large secundum atrial septal defects in adults using the buttoned device.

OBJECTIVES: To determine the success rate of transcatheter closure of secundum atrial septal defects (ASDs) in adults and to characterize anatomical structures predisposing to unsatisfactory results. PATIENTS AND METHODS: Preinterventional and follow-up transesophageal echocardiography of 17 consecutive patients treated with a Sideris buttoned device was reviewed. Residual jet size of 5 mm or smaller was considered an adequate result; jet size larger than 5 mm was inadequate. Maximal ASD diameter, ASD area, and anterior, posterior, superior, and inferior septal rims were measured. RESULTS: The 7 patients with adequate results (41%) had smaller defects before implantation of a buttoned device (mean +/- SD maximal ASD diameter, 12 +/- 4 vs 19 +/- 5 mm; P<.005). Total rim length (mean +/- SD) was longer in patients with an adequate result (71 +/- 8 vs 46 +/- 11 mm; P<.001). The ASD size and length of the superior septal rim were independent predictors for an adequate result. Only 3 patients, all with ASD diameter less than 13 mm, had completely closed defects. All patients with ASD diameter greater than 20 mm had inadequate results and an unsatisfactory device position. The defect size (mean +/- SD) was similarly reduced in patients with adequate and inadequate results (9 +/- 3 vs 8 +/- 4 mm). CONCLUSION: Adults with a small ASD are more likely to have an adequate result after treatment with the buttoned device. A sufficiently large superior septal rim is particularly important for an adequate result. Most patients with a large ASD have inadequate results, although their ASD size is reduced by a similar absolute area as in patients with an adequate result.

Adolescent↗

[Acromegaly].

Explore the source record for details and available documents.

Acromegaly↗

A prospective, randomized evaluation of nonsurgical closure of femoral pseudoaneurysm by compression device with or without ultrasound guidance.

Femoral artery pseudoaneurysm (PA) is a significant complication following diagnostic or therapeutic catheterization. The treatment of choice for femoral artery PA is freehand ultrasound-guided compression repair (UGCR). An alternative method is compression by mechanical devices. The study evaluated the mechanical compression device (FemoStop) with (G1) or without (G2) ultrasound guidance for initial placement in a randomized fashion. Thirty-eight patients (20 women, 18 men) age 40 to 85 (mean 54) years with clinical signs of PA underwent diagnostic color Doppler ultrasound. Randomization yielded 19 patients each for G1 and G2. PA occurred after 12 diagnostic cardiac catheterizations, 18 coronary stent implantations or balloon angioplasties, 2 electrophysiology procedures, and 6 peripheral percutaneous transluminal angioplasties. The G1 protocol was successful in 15 of 19 patients (79%), with a mean compression time of 28 min. The three other patients were treated successfully with UGCR. Only one patient needed vascular surgery. The G2 protocol was successful in 14 of 19 patients (74%) with a mean compression time of 33 min. The failed patients were treated successfully: three with UGCR and two with the same mechanical compression device now positioned under ultrasound control. Compression therapy with the compression device (FemoStop) for iatrogenic femoral pseudoaneurysm does not require ultrasound guidance for positioning. Cathet. Cardiovasc. Intervent. 47:304-309, 1999.

Aged↗

Comparative mutagenic and genotoxic effects of three antimalarial drugs, chloroquine, primaquine and amodiaquine.

Comparative mutagenic and genotoxic effects of three antimalarial drugs, chloroquine, primaquine and amodiaquine, were assessed in the Ames mutagenicity assay (in strains TA97a, TA100, TA102 and TA104) and in vivo sister chromatid exchange (SCE) and chromosome aberration (CA) assays in bone marrow cells of mice. These are the most commonly used antimalarial drugs available at present throughout the world. The results of the bacterial mutagenicity assays showed a very weak mutagenic effect of all three drugs in Salmonella strains TA97a and TA100 both with and without S9 mix and in TA104 only with S9 mix. The results of the in vivo SCE and CA assays indicate that these three drugs are genotoxic in bone marrow cells of mice.

Amodiaquine↗

Pseudoaneurysm of femoral artery after catheterisation: treatment by a mechanical compression device guided by colour Doppler ultrasound.

BACKGROUND: Femoral artery pseudoaneurysm is a significant complication in patients undergoing diagnostic or therapeutic catheterisation. First choice treatment for pseudoaneurysm is freehand ultrasound guided compression repair, which is time consuming and uncomfortable for the patient and operator. AIM: To explore a mechanical compression device (FemoStop) as an alternative treatment for iatrogenic femoral artery pseudoaneurysm. METHODS: Fourteen patients with pseudoaneurysm were considered for treatment with FemoStop after a brief freehand ultrasound guided compression repair to confirm the compressibility of the lesion. The FemoStop compression was applied for 20 minutes. The result was controlled with colour Doppler ultrasound, and a second cycle of 20 minutes followed if necessary. RESULTS: FemoStop compression was successful in 13 of the 14 patients. The mean compression time was 33 minutes (range, 20-60). The mean number of compression periods was 1.6 (range 1-3). FemoStop compression was successful in all 11 patients not taking anticoagulants and in two of three patients receiving anticoagulants. The mean compression time in patients given oral or intravenous anticoagulants was longer (50 v 27 minutes). Colour Doppler ultrasound 12 hours after the procedure indicated no recurrence of pseudoaneurysm in the 13 patients with initial success. CONCLUSIONS: FemoStop compression for iatrogenic pseudoaneurysm is feasible, and as safe and effective as freehand ultrasound guided compression repair. It is more comfortable for the patient and operator, and probably more economical than freehand compression.

Adult↗