Search PubMed⌕ Search

Biomedical subjects

T Chatterjee

Publications and source records attributed to T Chatterjee.

At least 37 records · Page 2Linked to original sources

Study of lipase-catalyzed hydrolysis of some monoterpene esters.

Studies of the hydrolysis of bornyl, citronellyl, geranyl, and terpenyl acetates by commercially available lipases of Candida rugosa, Rhizopus arrhizus, and Mucor miehei are presented. The hydrolysis of these monoterpene esters is investigated at various temperatures and pHs, and the time dependence of the percentage of esters hydrolysed is studied. The catalytic activities of the lipases in hydrolysing the esters are compared and, overall, it is observed that under the experimental conditions used the nonspecific lipase from C. rugosa produces the highest yields of the monoterpene alcohols in comparison to the primary-ester specific lipases such as R. arrhizus and M. miehei. A rate kinetic model has been used to understand the time dependence of the yield of the product acid.

Acetates↗

Reproductive health needs and care seeking behaviour of pavement dwellers of Calcutta.

An unabated growth of street dwellers in the city of Calcutta is reported to be due to twin reasons like, migration of rural poor people as well as uncontrolled fertility among these poor settlers of the city. A community-based study on reproductive health, fertility and related care seeking behaviour was studied among a sample of women of child bearing age living on streets of Calcutta. Besides, the quite common conditions like leucorrhoea (28.5%), menstrual irregularities (12.3%), infertility (2.5%) and STDs (1.3%) were also reported. But most of these illnesses (three-fourth) were uncared for, and the remaining one-fourth sought treatment from govemment institutions, private agencies or even from untrained practitioners (quacks). The reproductive behaviour of street dwelling women was characterised by early marriage, teenage pregnancies, and scarce use of contraceptives (32%) as well as frequent abortions (2.8%). Very few pregnant women received adequate antenatal care (3.8%). Coverage of tetanus toxoid immunisation (68.5%) and proper iron and folic acid supplementation (16.7%) were also poor. Whereas, antenatal care was received mostly from government health institutions (71%), home delivery (ie, on street) was a common practice and conducted mostly by untrained birth attendants (51.8%).

Adolescent↗

[Non-surgical closure of patent ductus arteriosus: acute and long-term results].

INTRODUCTION: Closure of a patent ductus arteriosus (PDA) even with small shunt volumes in asymptomatic patients is recommended because of the risk of endocarditis (1.5% per year) and the potential development of congestive heart failure or pulmonary hypertension. METHODS: 16 patients (9 adults [5 men/4 women] and 7 children [3 boys/4 girls]) underwent transcatheter closure of a PDA. The intervention was performed using the Rashkind umbrella in 12 cases, the Amplatzer duct occluder in 2 cases, a coil in 2 cases, and the Sideris self-adjusting device in one case. Echocardiographic controls were carried out one day, 6 months, 12 months and 24 months after the intervention. RESULTS: PDA closure was complete immediately following the intervention in 9 of 16 patients (56%). At follow-up (mean 19 months) complete closure was observed in 14 of 16 patients (87%). All residual shunts were trivial. The complete closure rate in adults was 100% and in children 71%. Complications such as device embolism, endarteritis and haemolysis did not occur. CONCLUSION: Non-surgical closure of a PDA is a safe and effective technique.

Adult↗

Percutaneous closure of patent foramen ovale in patients with paradoxical embolism: long-term risk of recurrent thromboembolic events.

BACKGROUND: Patients with a patent foramen ovale (PFO) and paradoxical embolism are at risk for recurrent thromboembolic events. This study investigated the long-term risk of recurrent thromboembolic events in patients with PFO and paradoxical embolism after percutaneous PFO closure. METHODS AND RESULTS: Since 1994, a total of 80 patients with PFO and at least 1 paradoxical embolic event (transient ischemic attack [TIA], cerebrovascular accident [CVA], peripheral embolism) have undergone percutaneous PFO closure with 5 different devices. There were 30 women and 50 men, with a mean age of 52+/-12 years. Sixty patients had only a PFO, whereas 20 patients had both a PFO and an atrial septal aneurysm. The implantation procedure was successful in 78 patients (98%). During 5 years of follow-up (mean, 1.6+/-1.4 years; range, 0.1 to 5.0 years), the actuarial annual risk to suffer a recurrent thromboembolic event was 2.5% for TIA, 0% for CVA, 0.9% for peripheral emboli, and 3.4% for the combined end point of TIA, CVA, or peripheral embolism. A postprocedural shunt was a predictor of recurrent paradoxical embolism (RR, 4.2; 95% CI, 1.1 to 17.8; P=0.03). The risk for recurrent thromboembolic events in patients with both atrial septal aneurysm and PFO was not significantly increased compared with patients with only PFO (RR, 1.0; 95% CI, 0.2 to 4.7; P=0.95). CONCLUSIONS: Percutaneous PFO closure appears to be a promising technique in the prevention of recurrent systemic thromboembolism in patients with a PFO after a first event. Prospective studies comparing percutaneous PFO closure with antithrombotic medications or surgery must define its therapeutic value.

Actuarial Analysis↗

Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale.

OBJECTIVE: During recent years, transcatheter closure has become an alternative to operations for the treatment of atrial septal defects and patent foramen ovale. However, this procedure may be unsuccessful or complicated and requires surgical treatment. METHODS: We retrospectively analyzed the outcomes of patients who needed surgical treatment after failed or complicated transcatheter closure of an atrial septal defect or a patent foramen ovale. RESULTS: Between April 1994 and March 1999, 124 patients were treated with transcatheter closure of an atrial septal defect or a patent foramen ovale at our institution. We report the results of 10 (8%) patients of this series who required operations after transcatheter closure attempts. In 8 of these 10 patients a significant shunt caused by malposition or dislocation of the device persisted, leading to surgical closure of the defect. In 2 patients injury of the femoral artery at the puncture site required surgical repair. In one patient the device had to be removed surgically from the iliac vein after retraction. One patient died of left ventricular perforation after dislocation of the device and several surgical attempts to close the left ventricular rupture. All other patients recovered well. CONCLUSION: An operation was required after transcatheter closure of an atrial septal defect or a patent foramen ovale in 8% of patients. After device complications, the atrial septal defect and the patent foramen ovale can still successfully be closed surgically with good results and low morbidity. However, serious complications like cardiac perforation may have a fatal outcome. Residual shunt, dislocation, or vascular complications are the most frequent problems that require surgical interventions.

Adolescent↗

Transesophageal echocardiography to evaluate success of transcatheter closure of large secundum atrial septal defects in adults using the buttoned device.

OBJECTIVES: To determine the success rate of transcatheter closure of secundum atrial septal defects (ASDs) in adults and to characterize anatomical structures predisposing to unsatisfactory results. PATIENTS AND METHODS: Preinterventional and follow-up transesophageal echocardiography of 17 consecutive patients treated with a Sideris buttoned device was reviewed. Residual jet size of 5 mm or smaller was considered an adequate result; jet size larger than 5 mm was inadequate. Maximal ASD diameter, ASD area, and anterior, posterior, superior, and inferior septal rims were measured. RESULTS: The 7 patients with adequate results (41%) had smaller defects before implantation of a buttoned device (mean +/- SD maximal ASD diameter, 12 +/- 4 vs 19 +/- 5 mm; P<.005). Total rim length (mean +/- SD) was longer in patients with an adequate result (71 +/- 8 vs 46 +/- 11 mm; P<.001). The ASD size and length of the superior septal rim were independent predictors for an adequate result. Only 3 patients, all with ASD diameter less than 13 mm, had completely closed defects. All patients with ASD diameter greater than 20 mm had inadequate results and an unsatisfactory device position. The defect size (mean +/- SD) was similarly reduced in patients with adequate and inadequate results (9 +/- 3 vs 8 +/- 4 mm). CONCLUSION: Adults with a small ASD are more likely to have an adequate result after treatment with the buttoned device. A sufficiently large superior septal rim is particularly important for an adequate result. Most patients with a large ASD have inadequate results, although their ASD size is reduced by a similar absolute area as in patients with an adequate result.

Adolescent↗

[Acromegaly].

Explore the source record for details and available documents.

Acromegaly↗

A prospective, randomized evaluation of nonsurgical closure of femoral pseudoaneurysm by compression device with or without ultrasound guidance.

Femoral artery pseudoaneurysm (PA) is a significant complication following diagnostic or therapeutic catheterization. The treatment of choice for femoral artery PA is freehand ultrasound-guided compression repair (UGCR). An alternative method is compression by mechanical devices. The study evaluated the mechanical compression device (FemoStop) with (G1) or without (G2) ultrasound guidance for initial placement in a randomized fashion. Thirty-eight patients (20 women, 18 men) age 40 to 85 (mean 54) years with clinical signs of PA underwent diagnostic color Doppler ultrasound. Randomization yielded 19 patients each for G1 and G2. PA occurred after 12 diagnostic cardiac catheterizations, 18 coronary stent implantations or balloon angioplasties, 2 electrophysiology procedures, and 6 peripheral percutaneous transluminal angioplasties. The G1 protocol was successful in 15 of 19 patients (79%), with a mean compression time of 28 min. The three other patients were treated successfully with UGCR. Only one patient needed vascular surgery. The G2 protocol was successful in 14 of 19 patients (74%) with a mean compression time of 33 min. The failed patients were treated successfully: three with UGCR and two with the same mechanical compression device now positioned under ultrasound control. Compression therapy with the compression device (FemoStop) for iatrogenic femoral pseudoaneurysm does not require ultrasound guidance for positioning. Cathet. Cardiovasc. Intervent. 47:304-309, 1999.

Aged↗