Search PubMed⌕ Search

Biomedical subjects

T Caus

Publications and source records attributed to T Caus.

At least 19 recordsLinked to original sources

Nitric oxide pathway after long-term cold storage and reperfusion in a heterotopic rat heart transplantation model.

Recent studies have suggested the involvement of the nitric oxide (NO) pathway in ischemia-reperfusion injury related to cardiac transplantation. Herein, we assessed the NO pathway by quantifying endothelial (e) and inducible (i) nitric oxide synthase (NOS) expression and total NOS activity in a rat heart transplant model during cold ischemia with Celsior cardioplegia and reperfusion. Experiments were performed using a modified Lewis-Lewis heterotopic abdominal heart transplantation with 3 or 6 hours of ischemia with or without 1 hour of blood reperfusion. NOS expression and activity were determined using Western blotting and colorimetric assays, respectively, on freeze-clamped hearts after ischemia without (n = 10) or with reflow (n = 12) compared with basal values. Hearts submitted to 3 hours of ischemia and 1 hour of reperfusion showed a postischemic rate pressure product of 5190 +/- 3047 mm Hg/min (reversible ischemia), but no contractility was observed after 6 hours of ischemia. eNOS protein levels were lower after 3 hours of ischemia compared with the basal value (P = .0005) and were further decreased after 6 hours of ischemia (P < .0001 versus basal value and P = .0018 versus 3 hours of ischemia). Reperfusion did not further decrease eNOS protein levels. iNOS protein was not detected in any condition. NOS activity was increased after 3 hours of ischemia versus basal value (P = .0065) but not after 6 hours of ischemia without any effect of reperfusion. We concluded that eNOS expression was altered during ischemia and the amplitude of the alteration depended on the duration of ischemia. Reversible ischemia was associated with increased NOS activity at the end of ischemia with no variation at reperfusion.

Animals↗

Increased plasma levels of pro-brain natriuretic peptide in patients with cardiovascular complications following off-pump coronary artery surgery.

OBJECTIVE: To compare N-terminal pro-brain natriuretic peptide (NT-pro-BNP), procalcitonin (PCT), and troponin I (Tn I) concentrations during and after coronary artery surgery in patients with or without cardiovascular complications. DESIGN AND SETTING: Prospective, comparative study of 12 months in the cardiovascular intensive care unit in a university hospital. PATIENTS: 60 adult patients undergoing coronary artery bypass grafting with the off-pump technique. MEASUREMENTS AND RESULTS: Plasma NT-pro-BNP, PCT, and Tn I levels were measured before and immediately after the end of operation and on PODs 1, and 2 and 3. We defined complicated postoperative course as myocardial infarction, cardiogenic shock, arrhythmias, congestive heart failure, and death occurring after the fourth postoperative hour. Receiver operating characteristic (ROC) curve cutoff values were used to assess the ability of the three markers to predict future cardiac events. The area under ROC curve (AUC) using NT-pro-BNP to detect a cardiovascular complicated course was 0.780 at the preoperative time and 0.850 at the end of surgery. A preoperative NT-pro-BNP value of 397 pg/ml had a sensitivity of 76%, specificity of 67%, and accuracy of 74% for predicting a subsequent cardiovascular complication. An immediate postoperative NT-pro-BNP value of 430 pg/ml had a sensitivity of 80%, specificity of 77%, and accuracy of 76%. Patients with preoperative NT-pro-BNP levels less than 275 pg/ml had an excellent postoperative prognosis. Other two markers were less appropriate. CONCLUSIONS: NT-pro-BNP levels measured before and immediately after off-pump coronary artery bypass seem to be predictive of postoperative cardiac events.

Aged↗

Modulation of the NO pathway during short or prolonged blood reperfusion following ischaemia in a heterotopic rat heart transplantation model.

Ischemia-reperfusion injury plays a major role in graft dysfunction following transplantation. Extensive research has demonstrated that nitric oxide (NO) plays a fundamental role to protect the heart against this injury. Consequently, we quantified NO synthase (NOS) isoform protein levels in a rat heart transplant model during short and prolonged reperfusion following ischemia. Experiments were performed using a modified Lewis to Lewis heterotopic abdominal heart transplantation with a total ischemic time of 3 hours followed by 1 or 24 hours of blood reperfusion (n = 12). Heart function, as represented by the rate pressure product, increased from 7912 +/- 489 to 27067 +/- 9982 mm Hg/min (mean +/- SEM, short vs prolonged reperfusion, P = .0027). NOS isoform protein levels determined using Western blotting of freeze-clamped hearts were compared to baseline values. eNOS protein levels were significantly lower during short reperfusion compared to the basal value (P = .0077) or to prolonged reperfusion (P = .004), returning to the basal value after 24 hours of reflow. iNOS protein was not detected in the basal condition or after 1 hour of reflow, but was present after 24 hours of reflow (P = .0001 vs basal value and 1-hour reflow). nNOS protein was 69% lower after 1 hour of reflow compared with the baseline value (P = .0001), it was not restored after 24 hours of reflow (P = .002). These results suggest involvement of the NO pathway in ischemia-reperfusion injury with distinctive roles of NOS isoforms during short and prolonged reperfusion following ischemia.

Animals↗

Protective effect of a low K+ cardioplegic solution on myocardial Na,K-ATPase activity.

Long duration ischemia in hypothermic conditions followed by reperfusion alters membrane transport function and in particular Na,K-ATPase. We compared the protective effect of two well-described cardioplegic solutions on cardiac Na,K-ATPase activity during reperfusion after hypothermic ischemia. Isolated perfused rat hearts (n = 10) were arrested with CRMBM or UW cardioplegic solutions and submitted to 12 hr of ischemia at 4 degrees C in the same solution followed by 60 min of reperfusion. Functional recovery and Na,K-ATPase activity were measured at the end of reperfusion and compared with control hearts and hearts submitted to severe ischemia (30 min at 37 degrees C) followed by reflow. Na,K-ATPase activity was not altered after 12 hr of ischemia and 1 hr reflow when the CRMBM solution was used for preservation (55 +/- 2 micromolPi/mg prot/hr) compared to control (53 +/- 2 micromol Pi/mg prot/hr) while it was significantly altered with UW solution (44 +/- 2 micromol Pi/mg prot/hr, p < 0.05 vs control and CRMBM). Better preservation of Na,K-ATPase activity with the CRMBM solution was associated with higher functional recovery compared to UW as represented by the recovery of RPP, 52 +/- 12% vs 8 +/- 5%, p < 0.05 and coronary flow (70 +/- 2% vs 50 +/- 8%, p < 0.05). The enhanced protection provided by CRMBM compared to UW may be related to its lower K+ content.

Adenosine↗

Late results of double-valve replacement with biologic or mechanical prostheses.

BACKGROUND: We previously showed that the risk of reoperation for structural degeneration of bioprostheses was higher in cases involving patients older than 65 years (p = 0.003) and double-valve replacement (p = 0.02). The purpose of this study was to compare late outcome of mitral-aortic valve replacement using bioprostheses or mechanical valves. METHODS: The bioprosthesis group included all mainland France residents (n = 48) between 55 and 65 years old operated on between 1980 and 1995 for mitral-aortic valve replacement using bioprostheses. The mechanical valve group was obtained by matching each of these patients with a patient operated on using mechanical valves at approximately the same time during the study. RESULTS: In the bioprosthesis group, 10-year survival was 45%+/-8% versus 62%+/-7% in the mechanical valve group (not significant). The linearized reoperation rate was 6.8 per patient-year versus 1.1 per patient-year (p = 0.001), and the linearized reoperative mortality rate was 1.8 per patient-year and 0.7 per patient-year (not significant), respectively. CONCLUSIONS: The reoperative mortality risk after mitral-aortic valve replacement using two bioprostheses does not significantly decrease overall survival after age 65 years.

Aged↗

Simultaneous study of metabolism and function following cardioplegic arrest: a novel method of evaluation of the transplanted heart in the rat.

BACKGROUND: Limitations of the isolated perfused rat heart model for heart preservation studies include short study time due to the lack of stability of the preparation. We aimed to develop a new experimental model based on heterotopic heart transplantation in the rat to achieve simultaneous (31)P magnetic resonance spectroscopy (MRS) and functional study of the transplanted heart during early and late blood reperfusion. METHODS: Twenty-five Lewis rats underwent heterotopic abdominal isograft heart transplantation and were randomized in two groups. Hearts were harvested after cardioplegic arrest induced with Centre de Résonance Magnétique Biologique et Médicale (CRMBM) solution and then stored at 4 degrees C for a total ischemic time of 3 hours. Graft contractility measurement and simultaneous (31)P MRS were performed after 1 hour and 24 hours of blood reperfusion, respectively, in groups I (n = 12) and II (n =13). RESULTS: Contractility improved during reperfusion. The mean rate pressure product plus or minus standard error of mean increased from 11,373 +/- 1,377 mm Hg/min in group I to 24,363 +/- 3,860 mm Hg/min in group II (P = 0.003), while mean dP/dtmax increased from 1,642 +/- 173 mm Hg/sec to 2,571 +/- 333 mm Hg/sec, respectively (p = 0.03). Simultaneously, both the phosphocreatine/adenosine triphosphate (ATP) and inorganic phosphate/ATP ratios decreased from group I to group II (p = 0.025 and p = 0.015, respectively), suggesting regeneration of the intracellular pool of ATP in group II. CONCLUSIONS: Simultaneous functional and metabolic studies of the transplanted heart are feasible in rats. Improvement in contractility during late reperfusion is contemporary with significant changes in energetic metabolism. Our model should be useful for the further improvement of heart preservation, which may result in significant clinical progress.

Adenosine Triphosphate↗

Late complications after prosthetic replacement of the ascending aorta: what did we learn from routine magnetic resonance imaging follow-up?

OBJECTIVE: Advances in surgical technique have improved early survival after surgery of the ascending aorta. However, follow-up data document serious late complications, mainly evolutive peri-prosthetic false aneurysms. Magnetic resonance imaging (MRI) has proved to be highly effective for monitoring these complications. This study evaluates 10 years of experience with routine MRI for follow-up. METHODS: Since January 1988, 114 patients with replacement of the ascending aorta either for type A acute dissection (group I, 45 patients) or aneurysms (group II, 69 patients) were followed up with annual MRI. Prosthetic replacement was either limited to supra-coronary ascending aorta (45%, 51/114) or extended to the aortic root and/or the aortic arch (55%). Biological glue was always utilized. MRI focused on peri-prosthetic haematoma, analyzing signal intensity changes and volume augmentation for early detection of false aneurysms, and on persistent residual dissection with or without evolutive aortic aneurysm distant to the prosthesis. RESULTS: Peri-prosthetic hematomas were almost equally found in both groups (26 (58%) in group I and 42 (61%) in group II) and were detected within the first year. Peri-prosthetic false aneurysms developed in 15 patients (group I, seven; group II, eight) as a complication of pre-existing hematomas and were indicated for elective reoperation. Forty-three (96%) of patients in group I had persistent residual dissection. Five patients in group I and two in group II needed reoperation for evolutive aortic aneurysm. In total, 22 of 114 (19%) patients were reoperated on during follow-up (12 (27%) in group I and ten (15%) in group II). Operative mortality was 13% (3/22). Freedom from reoperation at 1 year/5 years was: group I, 93%/84%; group II, 98%/88%. CONCLUSION: Peri-prosthetic haematoma occurs equally after aneurysm or dissection repairs and is a pre-existing condition for peri-prosthetic false aneurysm; biological glue or extended repair do not prevent late complications. Long-term MRI follow-up allows successful elective reoperation for life-threatened but asymptomatic patients.

Adult↗

Centrifugal pumps and heparin-coated circuits in surgical treatment of giant cerebral aneurysms.

Giant cerebral aneurysms may be untreatable by conventional neurosurgical techniques. Early attempts to use circulatory assistance and deep hypothermia were abandoned due to hemorrhagic complications. More recently, interest in circulatory support for complex neurosurgical procedures has been renewed. A consecutive series of 8 patients were operated on for giant cerebral aneurysms with the combined use of deep hypothermia. The protocol included careful preoperative cardiovascular assessment, perfect intraoperative synergy between neurosurgical and cardiac teams, minimally invasive peripheral vascular access including two femoral vein (21 F) and single arterial (17 F) femoral cannulation, use of total Carmeda coating on BioMedicus pumps in closed circuits, and reduced heparinization without Protamine reversal. All cerebral aneurysms were successfully treated through deep hypothermia (15-18 degrees C) as assessed by intraoperative fluoroscopic controls and Doppler vascular assessment. Mean circulatory support time was 174.2 +/- 29.6 min. Circulatory arrest period was 20 +/- 12 min. All patients survived and were extubated within 48 h. No major deficit was observed clinically or on postoperative CT scan. No hemorrhagic complications occurred (mean transfusions was 2.2 blood units). This work supports an extensive use of heparin-coated surfaces for complex circulatory assist techniques, either for cardiac or extra cardiac complex procedures.

Adolescent↗

Clinical evaluation of heparin-coated circuits for routine coronary artery bypass grafting surgery: a prospective randomized study.

The aim of this study was to demonstrate the clinical and biological benefits of heparin-coated circuits in routine coronary artery bypass grafting (CABG). A prospective, randomized study was conducted in 80 patients undergoing routine CABG. Patients were randomized to either noncoated circuits (Group 1) or heparin-coated circuits (Group 2). A complete clinical evaluation was performed preoperatively at Days 0, 1, 2, and 3 and at discharge day and combined with extensive laboratory tests for hemostasis and inflammatory response. This study did not prove any major statistically significant clinical benefit of heparin-coated circuits in low risk patients. Postoperative bleeding, significantly less in the heparin-coated group, did not decrease significantly the number of transfused patients. Biological values were not changed significantly except for factor II and monocytes, which were higher in Group 2. Heparin-coated circuits offer minimal clinical and biological benefits for routine CABG surgery. However, they may prove beneficial for complex procedures or at-risk patients.

Aged↗

Rescue revascularization for acute coronary occlusion late after radiotherapy.

Because radiation-induced coronary artery stenoses are frequently severe and located proximally, some patients are admitted in emergency. This report describes the case of a 47-year-old woman with radiation-induced stenosis of the left main coronary artery who presented with cardiac arrest during angiography. The patient was successfully treated using circulatory assistance and percutaneous transluminal coronary angioplasty as a bridge to coronary artery bypass grafting.

Angioplasty, Balloon, Coronary↗

Optimized cardiac graft preservation: a comparative experimental study using P-31 magnetic resonance spectroscopy and biochemical analyses.

BACKGROUND: The University of Wisconsin (UW), St. Thomas (ST) and Broussais (B) solutions were compared to the CRMBM solution, that we developed for long term heart preservation. METHODS: Isolated isovolumic rat hearts were arrested with each cardioplegic solution (n = 5) to 8 hearts in each group), submitted to 12 hours of cold storage (4 degrees C) in the same solution and then reperfused for 60 minutes at 37 degrees C. Function was measured during control and reflow. High energy phosphates and intracellular pH were monitored by P-31 magnetic resonance spectroscopy. Analyses were performed by biochemical assays and HPLC in coronary effluents (CK, Pi, lactate, purines) and in freeze-clamped hearts (amino acids, nucleotides, CK, LDH) at the end of reperfusion. RESULTS: Functional recovery was significantly improved with the new cardioplegic solution (50+/-12% recovery for the rate pressure product at the end of reflow vs 8+/-3% with UW, 0% with B and with ST). This result was correlated with the best metabolic and cellular protection as assessed in particular by higher PCr levels during reflow (30+/-3% vs 10+/-3% with UW, 8+/-4% with B, and 7+/-1% with ST) as well as reduced creatine kinase leakage during reflow (110+/-15 IU/60 minute vs 270 +/- 57 IU/60 minute with UW, 323+/-36 IU/60 minute with Broussais solution and 237+/-18 IU/60 minute with ST). CONCLUSION: This new solution is more effective in prolonged myocardial protection than the three most widely used solutions.

Acid-Base Equilibrium↗

Asymptomatic intracardiac thrombi and primary antiphospholipid syndrome.

Intracardiac thrombi have rarely been reported in patients with the antiphospholipid syndrome. We describe a new case revealed by systematic echocardiography in an asymptomatic woman who consulted for mild thrombocytopenia. Our case is characterized by a past history of migraine, fetal loss and psychiatric disturbances and by a high level of antiphospholipid antibodies (anticardiolipin, anti-beta(2)-glycoprotein I and lupus anticoagulant). Echography, in the absence of any cardiovascular symptom, showed bulky right intra-atrial thrombi requiring surgical excision. Histopathological analysis revealed the fibrino-cruoric nature of the lesion without myxoma. This case shows that, when faced with a mild thrombocytopenia associated with antiphospholipid antibodies, echocardiography may reveal a life-threatening and completely asymptomatic intracardiac thrombosis.

Adult↗

Multiple valve replacement increases the risk of reoperation for structural degeneration of bioprostheses.

BACKGROUND AND AIM OF THE STUDY: The study aim was to analyze the results of reoperations for structural degeneration of bioprostheses, and to define a high-risk population for reoperative procedures. METHODS: A series of 524 consecutive patients who had undergone a first reoperative replacement for a failed bioprosthesis between 1978 and 1998 was reviewed retrospectively. The reoperative procedure comprised 363 single valve replacements, and 161 multiple valve replacements. During the original procedure, 648 bioprostheses had been implanted in the mitral (n = 403), aortic (n = 220) and tricuspid (n = 25) positions. RESULTS: The mean interval between the original procedure and reoperation was 8.8 +/- 3.3 years. Tissue valve failure was revealed by recurrence of cardiac insufficiency in 70% of cases. The overall early mortality rate was 8%, but early mortality rates for elective single mitral and aortic reoperative valve replacements were only 3.9% and 4%, respectively. Early mortality following reoperation for single and multiple valve replacement was 6.0% and 12.4% respectively (p = 0.02). Other significant multivariable predictors for early mortality were old age (p = 0.003), NYHA functional class (p = 0.007), presence of ascites (p = 0.02) and reoperation performed before 1988 (p = 0.013). CONCLUSIONS: The risk of reoperation for structural degeneration of bioprostheses is acceptable for elective single reoperative valve replacement as opposed to multiple reoperative valve replacement. This may limit the use of bioprostheses during the original procedure when multiple valve replacement is required.

Bioprosthesis↗