Search PubMed⌕ Search

Biomedical subjects

T Buczkowski

Publications and source records attributed to T Buczkowski.

5 recordsLinked to original sources

Influence of mobile phones on accuracy of ECG interpretation algorithm in automated external defibrillator.

BACKGROUND: Automated External Defibrillators (AED) are a recommended tool for out-of-hospital emergency medical services. Mobile phones (GSM) are a potential source of electromagnetic interference which may cause failure of ECG interpretation and subsequent inappropriate action of AED's. METHODS: We evaluated the influence of 900 MHz GSM phones on the accuracy of automatic ECG interpretation with a GSM Mobile Station Tester with adjustable power and mode of transmission (Hewlett-Packard HP5515A), GSM phones (Alcatel, Ericsson, Nokia, Panasonic), ECG simulator (Metron) and four AEDs (Fore Runner-Hewlett-Packard, Heartstart 3000-Laerdal, Cardio-Aid 100-Artema, Heartstream XLT-Agilent). The protocol included 18 different ECG patterns, different ECG voltages, and different power and mode of transmission. RESULTS: The first stage of the protocol included minimal power of signal transmitted from GSM Mobile Station Tester and maximum power of GSM phone's signal--hence maximal potential interference to AED. The protocol was based on close direct contact between the GSM phone and the AED device. Regardless of the ECG pattern, with both 0.5 and 1.0 mV ECG voltage, and the GSM phone placed on various parts of AED device or at the patient cable, no failure of AED algorithm occurred. No detectable noise was seen at AED's ECG display. CONCLUSION: AEDs seems to be well protected against clinically significant failure caused by noise from 900 MHz GSM phones.

Electric Countershock↗

[Cefamandole for perioperative prophylaxis in total hip alloplasty].

The aim of this paper was to present the use of Cefamandole as one of the elements in perioperative prophylactics in total hip replacement. One hundred patients operated between 1993 and 1995 were followed-up for mean 13.5 months. There were 33 males and 67 females, mean age was 61.4 years. Cefamandole was administered according to fixed protocol for three days (first dose along with premedication). Mono-antibiotic therapy was sufficient in most cases. No septic complication occurred, no side-effects of Cefamandole were recorded. The patients are still being followed-up. Results achieved resemble these from the literature so conclusion can be made, that Cefamandole is safe and efficient drug for peri-operative prophylactics in total hip replacement.

Antibiotic Prophylaxis↗