Search PubMed⌕ Search

Biomedical subjects

T Bende

Publications and source records attributed to T Bende.

At least 19 recordsLinked to original sources

[Impairment of mesopic vision following photorefractive keratectomy of myopia].

PURPOSE: Halos, glare disability and problems during night driving are significant side effects of photorefractive keratectomy, caused by increasing optical aberrations under reduced conditions of luminiscence. In a previously performed retrospective study an impairment of mesopic vision in most of the investigated eyes was found. To prove these results, a prospective study was conducted. METHODS AND PATIENTS: In a prospective, consecutive study mesopic function was investigated in 41 myopic patients, who were interested in PRK. 26 patients underwent surgery (Summit ExciMed UV200LA, optical zone 5 mm), which was performed in 30 eyes. Mesopic function (contrast vision, glare sensitivity) was measured by using the Mesoptometer II test in all 30 eyes preoperatively and 6 to 9 months postoperatively. Additionally, 21 eyes were examined after 12 to 15 months of follow up. RESULTS: There was a statistically significant reduction of contrast vision and increase of glare sensitivity after 6 to 9 and 12 to 15 months. The Mesoptometer II contrast level of 1:5 (with and without glare) can be used as a critical parameter for the decision, whether mesopic function is markedly reduced or not. Before surgery, contrast level of 1:5 without glare was not recognized in 30%, with glare in 40%. After 6 to 9 months, this contrast level was not recognized in 73% of the 30 eyes without glare, with glare in 80%. Out of these 30 eyes, 21 eyes were followed over 12 to 15 months. Whereas 38% of these eyes (with glare 48%) did not recognized the critical contrast level before surgery, this rate increased to 67% (with glare 81%) 12 to 15 months after surgery. CONCLUSIONS: Impairment of mesopic function has to be considered as a possible side effect of PRK (optical zone 5 mm). Although further investigations are needed, the indication for PRK in special professions (pilots, professional drivers) should be very critical discussed.

Adult↗

[Current status of infrared photoablation of the cornea].

BACKGROUND: IR-photothermal ablation has, for some time, been described as an alternative to UV photoablation with Excimer lasers. Both procedures are based on different laser-tissue-interactions. IR solid state lasers have cost advantages over UV laser technology and allow a broader clinical use. New beam shaping principals had to be developed. IN-VITRO: Systematic biophysical investigations, recently using tunable Free Electron Lasers, have described the ablation efficiency, the collateral thermal adverse effects, the surface properties and particle size, and the dynamic behaviour of the particle ejection, all as a function of wavelengths (and thus of different absorbers in the corneal tissue), of energy and of different pulselengths. The free running Er:YAG laser is suitable and well investigated, the optic parametrical oscillator (OPO) with supershort pulses a more recent alternative. IN VIVO: First in vivo photoablation with different Er:YAG lasers has proved the principle feasibility of IR photoablation. Histology of enucleated human eyes indicates that the wound healing and repair after IR photoablation is not principally different from UV-PRK. The evaluation of the achievable optical quality of the cornea in vivo as well as data on the stability resp. regression of the ablation profiles are still pending.

Animals↗

[Dielectric spectroscopy for noninvasive examination of corneal tissue].

Dielectric spectroscopy is a non-invasive contact technique that permits the in vivo measurement of the specific electrical properties of biological tissue induced by an external electrical field. Permittivity, relaxation time and specific conductivity as a function of corneal hydration (wet weight/dry weight) and temperature were measured in 10 porcine corneas. Variation of tissue hydration has a minor influence on the signal, with a significant variation of the signal being detectable only for relatively dry tissue. A much greater influence was found for temperature, in particular on relaxation times. Dielectric spectroscopy provides us with an opportunity to detect structural, in particular temperature-induced, changes in living tissue. In the frequency range investigated, hydration has only a small influence on the dielectric properties of the tissue.

Animals↗

Holmium:YAG thermokeratoplasty: treatment parameters for astigmatism induction based upon spherical enucleated human eyes.

BACKGROUND: The refractive outcome of thermokeratoplasty for astigmatism correction depends upon the optical zone diameter (OZD) and coagulation angle (CA; distance between two coagulation spots around the flat meridian). METHODS: Astigmatism was induced in 36 spherical human eye-bank eyes (Ho:YAG laser, 15 Hz, 20 mJ/pulse, 25 pulses per coagulation spot) with different OZDs and CAs. Thirty eyes received free-hand laser application (marked positions). Six eyes were treated using a suction mask, providing a constant OZD of 8.1 mm and an angle of 22.5 degrees between the laser spots. To compare the results, silicone replicas of the eyes were made pre- and postoperatively and analyzed by video-topometery. RESULTS: With an average decrease of 4 D/mm the refractive change is inversely linear to the OZD. Changes of the CA showed significant variations between 22.5 degrees and 45 degrees, only. Mask guidance leads to the same amount of average refractive change. The deviation is +/- 3.4 D for the freehand application but only +/- 0.8 D for mask guidance. CONCLUSION: The data obtained in this in vitro study are transferred to a treatment nomogram describing the immediate postoperative refractive change, not identical with the final refraction. The results of the study are limited by the fact that astigmatism was induced in spherical corneas, rather than correcting preexisting ones.

Astigmatism↗

Mesopic vision in myopia corrected by photorefractive keratectomy, soft contact lenses, and spectacles.

PURPOSE: To evaluate contrast vision and glare sensitivity under mesopic conditions in eyes having uncomplicated excimer laser photorefractive keratectomy (PRK) for myopia and in eyes corrected by disposable soft contact lenses, soft contact lenses, and spectacles. SETTING: Division of Experimental Ophthalmic Surgery, University of Tübingen, Germany. METHODS: The Mesoptometer II test was used to evaluate mesopic vision (glare sensitivity and contrast vision) in 28 eyes of 14 patients wearing disposable soft contact lenses, 20 eyes of 10 patients wearing soft contact lenses, 39 eyes of 20 patients wearing spectacles, 30 eyes of 15 emmetropic patients, and 33 eyes of 22 patients after PRK with 5.0 mm optical zone. Follow-up was between 15 and 60 months after PRK (mean 34.5 months). RESULTS: The guidelines of the German Ophthalmologic Society state that patients must recognize Mesoptometer II contrast levels of 1:5 or better with and without glare to meet the minimum legal night-driving standards for private cars. All eyes with disposable soft contact lenses and soft contact lenses, all emmetropic eyes, and 38 eyes corrected by spectacles recognized contrast levels of 1:5 or better without glare. In contrast, 18 eyes in the PRK group were unable to recognize contrast level 1:5 without glare. With glare, 1 eye in the disposable soft contact lens group, 1 in the soft contact lens group, and 7 with spectacles were unable to recognize the 1:5 contrast level. All emmetropic eyes recognized contrast levels of 1:5 or better; 22 PRK eyes were unable to recognize contrast level 1:5 with glare. CONCLUSION: Myopic PRK may lead to long-term impairment of mesopic vision, while soft contact lens use does not seem to markedly influence mesopic vision in eyes with low to moderate myopia.

Adolescent↗

Automated compensation of defocusing errors in videokeratography.

PURPOSE: The reproducibility of videokeratography measurements is mainly dependent on the accuracy of manual adjustment in the focal plane. Videokeratoscopes having small Placido cones show a considerable amount of error when the required working distance between cornea and keratoscope is not maintained. The advantages of small cones (optimal illumination and the reduction of anatomically caused shadows) are in no proportion to the disadvantage-poor depth of focus, resulting in poor reproducibility. METHODS: The Tubingen Color Ellipsoid Topometer compensates with software and hardware for defocusing errors by means of a triangulation measurement. An 8.0 mm sphere (42 D) was measured in a distance range of +/- 1.5 mm around the focal plane with and without compensation. Five measurements were acquired at each position to evaluate the reproducibility of the calculated data. RESULTS: Defocusation in the range of +/-1.5 mm leads to deviation smaller than 0.05 mm (0.25 D). Without compensation, the maximal deviation is increased up to 0.7 mm (3.0 D), and thus is considerably greater. DISCUSSION: Automated compensation of defocusing errors in videokeratography actively compensates for defocusation errors, enhancing precision and avoiding measuring artifacts.

Cornea↗

Dynamic mechanical spectroscopy of the cornea for measurement of its viscoelastic properties in vitro.

Cylindric samples (3 mm in diameter) of explanted human corneas were biomechanically characterized in the frequency range from 0.1 mHz to 100 Hz with a specially modified viscoelasticity spectrometer. Such spectra of the shear compliance J (the reciprocal value of the shear modulus G) were measured as a function of corneal hydration and temperature. Variation of the hydration from 0.20- to 1.00-mm sample thickness (5-fold) changed the shear compliance 600-fold. Such a strong effect means that the shear-compliance spectra are highly sensitive to changes in the biomechanical properties of the cornea. This is demonstrated by three examples. A myopic cornea (-3D) was significantly softer (by a factor of 7 at lower frequencies and a factor of 4 at higher frequencies) than an emmetropic cornea. An increasing post mortem interval decreased the shear-compliance values (stiffening) obtained at higher frequencies (by a factor of 0.7 per day), whereas the values obtained at lower frequencies were reproduced. The biomechanics of thermal coagulation were studied in detail. The temperature was increased step by step, and at 48 degrees C a first irreversible decrease in the compliance was recorded at lower frequencies (0.8-fold). A further stiffening by a factor of 1/6 at lower frequencies and 1/5 at higher frequencies ended at 64 degrees C with a minimum in the compliance. To provide a new diagnostic tool, the biomechanical spectra of the cornea have to be measured in vivo. Equipment suitable for the megahertz range has been developed.(ABSTRACT TRUNCATED AT 250 WORDS)

Biomechanical Phenomena↗

[Moist ablation of the corneal surface with the Er:YAG laser. Results of optimizing ablation].

The Er:YAG laser, emitting light at 2.94 microns, may be an alternative to the 193 nm excimer laser for photorefractive keratectomy. Compared to the excimer laser, the ablation rate is very high. Surface roughness is also more pronounced than for the excimer laser. Using a precorneal liquid film, these two factors can be reduced, as shown in ablation experiments performed on porcine corneas. Thermal damage of the remaining corneal tissue is another side effect. There is no significant decrease in the amount of thermal damage with this new technique,--not even when the pulse length is reduced.

Animals↗

[Effect of pulse duration of the Er:YAG laser on photoablation in ocular tissue (cornea and sclera)].

After photoablation in corneal and scleral tissue with the Er:YAG laser, two zones of thermal damage can be detected: The first zone (about 3 microns thick) consists of thermally denatured debris. The second zone (about 30 microns thick) shows a slightly more intense staining (H&E) compared to the non-influenced tissue. Variation of laser pulse duration between 100 microseconds and 1300 microseconds does not influence the extension of these two thermal damage zones. Furthermore, ablation rate and ablation volume remain nearly constant within this range of pulse durations. These data were obtained by histology (H&E staining) and with a recently published silicon cast replica method. All experiments have been performed on corneas and sclera of pig eyes.

Animals↗

Silicone replica technique and automatic confocal topometry for determination of corneal surface roughness.

No method for the objective measurement of corneal surface roughness has thus far been available for experimental and clinical investigations. The surface roughness of photoablated porcine corneas was investigated with the silicone-cast method and automatic confocal topometry. Photoablation was performed with the 193-nm excimer laser. Surface roughness was determined as a function of the repetition rate (2-60 Hz; fluence, 180 mJ/cm2; beam diameter, 2 mm; 300 laser pulses/experiment). Immediately after photoablation, a silicone replica of the ablated surface was made and analyzed later using confocal topometry. The surface roughness for excimer laser ablation was found to be frequency-dependent: 0.4-0.6 +/- 0.08 micron (2-30 Hz) and 1.2 +/- 0.12 micron (60 Hz). The silicone cast of the cornea of a healthy eye gave an exact image of the profile and curvature: the difference between radius measurements of the cornea (Zeiss ophthalmometer) and of the silicone cast (laser topometer) was about 0.5%. As the silicone-cast method can also be used for in vivo animal experiments, the correlation between surface roughness and laser repetition rate can be studied with regard to photorefractive keratectomy.

Animals↗

Noncontact photoacoustic spectroscopy during photoablation with a 193-nm excimer laser.

Photoablation with the 193-nm excimer laser in organic and inorganic material generates an audible sound wave; in a clinical context, this helps to determine when effective photoablation is taking place. We investigated whether the acoustic phenomenon would qualify as a quantitative parameter of photoablation during non-contact photoacoustic spectroscopy (NCPAS). Photoablation was performed with a 193-nm excimer laser at a fluence of 80-330 mJ/cm2 and ablation-zone diameters ranging between 1.2 and 5.13 mm. A capacitor microphone (Broel & Kjaer) emitted a time signal that was processed for Fourier transformation (FT, spectrum of frequency). The following elements of the FT-signal were studied: the integral, the amplitude, the half-value, and the location of the center frequency. The integral and the amplitude were correlated linearly with the fluence. Variation of the ablation-zone diameter between 1.2 and 5.13 mm was found to produce a squared increase of the integral and the amplitude (fluence, 180 mJ/cm2). The half-value and the center of frequency of the FT signal were constant for the same target material but varied between materials. NCPAS may qualify for the future control of various photoablation and laser parameters such as incision depth, ablation-zone diameter, fluence, and target-material identification and discrimination. Its advantage over competing optical methods is its independence from optical target properties (e.g., fluorescence, surface roughness, reflectivity).

Acoustics↗

[Silicone impression procedure. Principles for determining ablation and healing parameters in vitro and in vivo].

Topometry and measurement of photoablation patterns are key questions for keratorefractive photoablation. So far, ablation rates have been determined either by tissue perforation or histological micrometry. A cast of irradiated cornea was made by using a 2-component silicon that polymerizes within minutes, thus preserving the corneal topography immediately after photoablation. The silicon surface is extremely smooth and the accuracy of the cast better than 1 micron. Reproducibility and long-term stability were proven for casts of photoablated PMMA. Thus ablation rates and profile, volumetry and topometry can be determined at any time. The method was applied for 193 nm excimer and 2.94 microns Er:YAG laser in vitro irradiation of the human cornea. Ablation rates in Bowman's layer and stroma were observed for various radiant energies and distinct pulse numbers. The average ablation rates are in agreement with published data. It could be demonstrated that there was an incubation effect for the first pulses. The method feasibility for in vivo measurement was also proven in an animal model. After excimer photoablation in rabbit eyes (beam diameter 3.5 mm, radiant energy 185 mJ/cm3, ablation rate 0.3 micron/pulse), wound healing was recorded: for the right eye silicon casts were molded at three different moments. For the left eye only photographs were taken. There was no difference in the time course of wound healing, so the silicon does not seem to interfere with repair mechanisms of the corneal epithelium. No side effects were observed.

Animals↗

[Laser coagulation of the cornea with a holmium:YAG laser for correction of hyperopia].

We present a new technique of hyperopic correction similar to radial thermokeratoplasty. A pulsed Ho: YAG laser was used that emitted radiation at 2.06 microns and was guided by a quartz fiber and a focusing hand piece. The penetration depth of this light in the cornea is about 400 microns. Eight or 16 concentric point coagulations result in steepening in the central cornea. This refractive change is inverse related to the distance to the cornea center, and it increases linearly with increasing laser pulse energy. In four blind eyes it was demonstrated that the parameters evaluated in cadaver eyes can be transferred to living eyes. Surprisingly, the refractive change so created of up to 5 dpt is stable within a period of 4 months. Immediately after surgery, concentric descemet folds can be detected, which gradually decrease within the period reported.

Cornea↗

[Photoablation with the Er:YAG laser in ocular tissues].

Photoablation of ocular tissues is not restricted to the excimer laser. Alternative tools are erbium lasers. As there is maximum absorption in ocular tissue at about 3 microns, two types of erbium lasers are capable of photoablation. One is the Er:YAG laser working at a wavelength of 2.94 micron; the other is the Er:YSGG laser emitting light with a wavelength of 2.79 microns. Both lasers produce higher ablation rates than the excimer laser. In comparison to the excimer laser (thermal damage of less than 1 micron), there is more thermal damage in the remaining tissue (3 microns). The lower ablation rate of the Er:YSGG laser due to the greater distance of the wavelength from the absorption maximum can be compensated by a higher output energy and a higher repetition rate (25 Hz). Wound-healing studies in rabbit corneas show no significant differences between the excisions performed with the Er:YAG laser and 193 nm excimer laser.

Cornea↗