Search PubMed⌕ Search

Biomedical subjects

T B Borak

Publications and source records attributed to T B Borak.

At least 19 recordsLinked to original sources

Comparisons of LET distributions for protons with energies between 50 and 200 MeV determined using a spherical tissue-equivalent proportional counter (TEPC) and a position-sensitive silicon spectrometer (RRMD-III).

Experiments have been performed to measure the response of a spherical tissue-equivalent proportional counter (TEPC) and a silicon-based LET spectrometer (RRMD-III) to protons with energies ranging from 50-200 MeV. This represents a large portion of the energy distribution for trapped protons encountered by astronauts in low-Earth orbit. The beam energies were obtained using plastic polycarbonate degraders with a monoenergetic beam that was extracted from a proton synchrotron. The LET spectrometer provided excellent agreement with the expected LET distribution emerging from the energy degraders. The TEPC cannot measure the LET distribution directly. However, the frequency mean value of lineal energy, y(-)(f), provided a good approximation to LET. This is in contrast to previous results for high-energy heavy ions where y(-)(f) underestimated LET, whereas the dose-averaged lineal energy, y(-)(D), provided a good approximation to LET.

Linear Energy Transfer↗

NOREC, a Monte Carlo code for simulating electron tracks in liquid water.

The work reported here was originally motivated by a discussion of Monte Carlo computer codes for electron transport in water given in Report No. 130 by the National Council on Radiation Protection and Measurements (NCRP). It was pointed out (correctly) that a published depth-dose distribution calculated by the Oak Ridge electron transport code, OREC, for 800 keV electrons normally incident on a water slab was apparently in error, possibly due to inadequate treatment of elastic scattering. In this paper we describe the replacement of the original OREC elastic cross sections by current ones from the National Institute of Standards and Technology (NIST). This investigation led also to the critical examination and revision of some other parts of the program, as described here. The revised code, which we have renamed NOREC, represents the first substantial review and modification of the Oak Ridge code in a number of years. We also present some comparisons of results calculated with the old and new versions and discuss their implications with respect to earlier studies. We have also written a version of NOREC in C++ language, which is available to other investigators. This paper provides a record of a response to the NCRP published statement and documentation for the revised code, NOREC.

Algorithms↗

The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon.

The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.

Cosmic Radiation↗

Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III).

Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.

Cosmic Radiation↗

A method for determining leakage of 133Xe gas from septum-sealed glass vials.

We have developed a method for determining the leakage of 133Xe gas from septum-sealed glass vials that are supplied for medical examinations. Twenty vials each originally containing 370 MBq of 133Xe and 20 vials each originally containing 740 MBq 133Xe were measured daily for 26 d. Retention of 133Xe within the vial was modeled as a first order process with a constant rate coefficient, lambdaT. The value of lambdaT was estimated for each vial using a regression analysis. The leakage rate, lambdaL, was then determined assuming that lambdaT = lambdaL + lambda(r) where lambda(r) represents the physical decay of 133Xe. Monte Carlo simulations were performed using uncertainties in the estimates of each vial to obtain the mean and tails of the distribution for the average leakage rate, lambdaL. The average leakage rate for the complete sample of vials was 0.00007 d(-1) with an upper, one-sided, 95% confidence limit of 0.0011 d(-1). Uncertainties in the published values of lambda(r) for 133Xe made a significant contribution to the uncertainties of the leakage rate for this sample of vials. The methods described can be applied to other situations where leakage of radioactive materials may be of concern.

Glass↗

Continuous measurements of outdoor 222Rn concentrations for three years at one location in Colorado.

Measurements were made of 222Rn concentrations outdoors in Ft. Collins, Colorado, using a continuously sampling scintillation flask between January 1993 and December 1995. These data were analyzed for hourly, daily, and seasonal variations. The average 222Rn concentration at 1 m above the ground was 18 +/- 10 Bq m(-3) with a geometric mean of 15 Bq m(-3) and a geometric standard deviation of 1.7. Hourly averaged data indicated a diurnal pattern with the outdoor 222Rn concentration reaching a maximum in the early morning between 4:00 a.m. and 6:00 a.m. and a broad minimum between 1:00 p.m. and 4:00 p.m. in the afternoon. An analysis also indicated that the outdoor 222Rn concentrations were consistently lowest during the spring (March and April) and highest during the late summer (July-September).

Air Pollution, Radioactive↗

Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles.

Tissue-equivalent proportional counters (TEPCs) have been used to measure energy deposition in simulated volumes of tissue ranging in diameter from 0.1 to 10 microm. There has been some concern that the wall used to define the volume of interest could influence energy deposition within the sensitive volume because it has a density significantly greater than that of the cavity gas. These effects become important for high-velocity heavy ions. Measurements of energy deposition were made for 1 GeV/nucleon iron particles in a TEPC simulating a 1-microm-diameter sphere of tissue. The TEPC was nested within a particle spectrometer that provided identification and flight path of individual particles. Energy deposition was studied as a function of pathlength through the TEPC. Approximately 30% of the energy transfer along trajectories through the center of the detector escapes the sensitive volume. The response of the TEPC, for trajectories through the detector, is always larger than calculations for energy loss in a homogeneous medium. This enhancement is greatest for trajectories near the cavity/wall interface. An integration of the response indicates that charged-particle equilibrium is essentially achieved for a wall thickness of 2.54 mm. However, estimates of the linear energy transfer for the incident particles are influenced by these wall effects.

Gases↗

Effects of volume irradiated on the function of the canine ureter.

This study was designed to investigate the influence of the volume irradiated on the probability of ureteral complications and to provide data for volume modeling. One hundred thirty-four purpose-bred beagle dogs received single intraoperative doses of 6 MeV electrons ranging from 12 to 54 Gy to three lengths of ureter: 2, 4 or 8 cm. The response was evaluated by excretory urography. The ED50 was 21.9 Gy (95% CI 13.3-30 Gy) for 8 cm 3 years after treatment. The estimated ED50's were greater than 43 Gy for 4 cm and 85 Gy for 2 cm. Reducing the length of ureter irradiated from 8 cm to 4 cm increased the ED50 for ureteral dilation by at least a factor of 2, while reduction from 8 cm to 2 cm increased the ED50 by at least a factor of 4. The ED50 for renal injury secondary to stenosis was 30.5 Gy (95% CI 17.2-232 Gy) when an 8-cm field was irradiated. There was a significant effect of volume irradiated on the frequency of ureteral stenosis. Reducing the length of ureter included in the treatment field should allow delivery of higher doses to tumors without increased complications.

Animals↗

Effects of intraoperative irradiation and intraoperative hyperthermia on canine sciatic nerve: neurologic and electrophysiologic study.

PURPOSE: Late radiation injury to peripheral nerve may be the limiting factor in the clinical application of intraoperative radiation therapy (IORT). The combination of IORT with intraoperative hyperthermia (IOHT) raises specific concerns regarding the effects on certain normal tissues such as peripheral nerve, which might be included in the treatment field. The objective of this study was to compare the effect of IORT alone to the effect of IORT combined with IOHT on peripheral nerve in normal beagle dogs. METHODS AND MATERIALS: Young adult beagle dogs were randomized into five groups of three to five dogs each to receive IORT doses of 16, 20, 24, 28, or 32 Gy to 5 cm of surgically exposed right sciatic nerve using 6 MeV electrons and six groups of four to five dogs each received IORT doses of 0, 12,16, 20, 24, or 28 Gy simultaneously with 44 degrees C of IOHT for 60 min. IOHT was performed using a water circulating hyperthermia device with a multichannel thermometry system on the surgically exposed sciatic nerve. Neurologic and electrophysiologic examinations were done before and monthly after treatment for 24 months. Electrophysiologic studies included electromyographic (EMG) examinations of motor function, as well as motor nerve conduction velocities studies. RESULTS: Two years after treatment, the effective dose for 50% complication (ED50) for limb paresis in dogs exposed to IORT only was 22 Gy. The ED50 for paresis in dogs exposed to IORT combined with IOHT was 15 Gy. The thermal enhancement ratio (TER) was 1.5. Electrophysiologic studies showed more prominent changes such as EMG abnormalities, decrease in conduction velocity and amplitude of the action potential, and complete conduction block in dogs that received the combination of IORT and IOHT. The latency to development of peripheral neuropathies was shorter for dogs exposed to the combined treatment. CONCLUSION: The probability of developing peripheral neuropathies in a large animal model was higher for IORT combined with IOHT, than for IORT alone. The dose required to produce the same level of late radiation injury to the sciatic nerve was reduced by a factor of 1.5 (TER) if IORT was combined with 44 degrees C of IOHT for 60 min.

Animals↗

Alpha pulse height distributions with ZnS(Ag) scintillator.

A flask coated with ZnS(Ag) scintillator is one of the most accurate detectors available for measuring 222Rn. To maintain this accuracy, the counting system consisting of a photomultiplier tube and associated electronics must be checked on a regular basis. A combination of an alpha source and a ZnS(Ag) scintillator is commonly used for these purposes. This paper compares the pulse height distributions of 4 alpha sources with the pulse height distribution from a 100 cm3 scintillation flask containing 222Rn. The source that most closely reproduced the distribution from an actual 222Rn sample in a 100 cm3 scintillation flask consisted of a sealed flask, of the same type, which contains a small piece of uranium-ore.

Alpha Particles↗

In-situ determination of the diffusion coefficient of 222Rn in concrete.

Measurements of the effective diffusion coefficient, De, of 222Rn in concrete are important for accurate determination of transport mechanisms and computer modeling of radon entry into structures. A method for in-situ determination of De as well as the emanation fraction, F, is described. It is based on continuous measurement of the radon flux from an intact slab and the concentrations on both sides. A non-linear regression algorithm was used to fit these data to the steady state solution to Fick's law. The regression output includes estimates of both De and F. The method has the advantage over typical laboratory procedures since it measures an undisturbed surface area of concrete where the samples exhibit moisture, temperature, and loading conditions that are experienced in a real structure. Effective diffusion coefficients ranged from 1.1 x 10(-8) to 4.4 x 10(-8) m2 s-1 for measurements of concrete floor slabs in two structures. The measured emanation fraction of radon in concrete in one structure was 0.2 +/- 0.02. A sensitivity analysis indicated that the values of De and F estimated by the regression procedure are strongly dependent on the thickness of the slab. The porosity of the concrete had little affect on the regression results.

Air Pollutants, Radioactive↗

A method for computing the decision level for samples containing radioactivity in the presence of background.

It is often necessary to make a decision whether or not a sample contains radioactivity in excess of background. The most common procedure is a deterministic approach that compares the result from each sample against a critical level, Lc. Originally Lc was derived from the case where each sample is paired with a blank or control that is known not to contain excess radioactivity. However, most analytic laboratories do not process a blank with each and every sample. Another approach computes Lc using a collection of measurements to form a "well defined" background. This paper presents a method for determining a decision level, L delta, that includes the uncertainties in both the mean and variance of background and how these combine to form uncertainties in estimating the tails of the background distribution. The values of L delta are greater than Lc for a given Type I error. It can be applied whenever the true distribution of background is either normal or log normal. The process is not restricted to counting statistics and is valid for identifying excess contamination of any type providing that unknown samples are processed identically to background samples.

Biological Assay↗

Intraoperative radiation (IORT) injury to sciatic nerve in a large animal model.

Peripheral nerve appears to be a dose-limiting normal tissue in the clinical application of intraoperative radiation therapy (IORT). To assess IORT injury to peripheral nerve, three groups of five beagle dogs received doses of 12, 20 or 28 Gy to the surgically exposed and isolated right sciatic nerve in the mid-femoral region using 6 MeV electrons. The left sciatic nerve of each dog served as its own control. As a surgical control five dogs received surgical exposure of the nerve only. Monthly neurologic exams, electromyogram and nerve conduction studies were performed following treatment for 12 months. After that dogs were euthanatized and histologic studies of nerves were done to define the degree of axon and myelin loss as well as presence of fibrosis and vascular lesions for different doses of IORT. Results showed that the threshold dose most likely related to expression of severe radiation damage to the nerve in this model is between 20 and 25 Gy. Radiation injury to peripheral nerve appears to be the result of direct radiation effects on Schwann cells and nerve vasculature and secondary effects resulting from damage to regional muscle and vasculature. A theoretical mechanism of radiation injury to peripheral nerve is proposed.

Animals↗

Partitioning of 222Rn entry into a structure surrounded by soil.

This paper describes the entry rate of 222Rn into a basement structure surrounded by a sandy clay loam soil. The highest indoor radon concentrations occurred when the rate of entry was lowest. Data from in-situ measurements were used to identify the entry pathways and also the origins of the radon during periods when the entry rate was low. Results indicated that 25% of the radon entered through the floor-wall joint and 75% through the floor and walls. About 30% of the radon originated in the concrete. Diffusion was the primary transport mechanism. However, radon entry through the floor-wall joint was a combination of diffusion and a convective flow between the subslab region and the interior of the structure.

Air Pollutants, Radioactive↗

A method for computing random chord length distributions in geometrical objects.

A method is described that uses a Monte Carlo approach for computing the distribution of random chord lengths in objects traversed by rays originating uniformly in space (mu-randomness). The resulting distributions converge identically to the analytical solutions for a sphere and satisfy the Cauchy relationship for mean chord lengths in circular cylinders. The method can easily be applied to geometrical shapes that are not convex such as the region between nested cylinders to simulate the sensitive volume of a detector. Comparisons with other computational methods are presented.

Monte Carlo Method↗

Characterization of 222Rn entry into a basement structure surrounded by low-permeability soil.

An experimental facility has been developed to monitor the entry rate and concentration of 222Rn in a basement-type structure surrounded by soil having a permeability on the order of 10(-11) m2. A data acquisition system recorded environmental conditions outside and inside the structures, plus basement air exchange rate information, every 15 min. Indoor 222Rn concentrations ranged from 400 to 1,400 Bq m-3. The observed 222Rn entry rate is highly variable and has two primary components; a constant input rate caused by diffusion of 222Rn through the concrete walls and floor, and a variable rate that depends upon indoor-soil pressure differentials of only a few pascals. Pressure differentials are dependent upon wind speed and wind direction. Stack effect was not significant. During a 2-wk period, with relatively calm winds, diffusion through the concrete walls and floor plus the floor-wall joint accounted for more than 80% of the total 222Rn entry.

Air Pollutants, Radioactive↗

Determination of time-varying 222Rn concentrations using flow-through scintillation flasks.

This paper describes a method to obtain time-varying 222Rn concentrations from the series of gross alpha measurements recorded with a flow-through scintillation detector. The continuous input of 222Rn into the detector is treated as a series of independent pulses. The response of the detector to a single pulse containing 222Rn can be measured in the laboratory and is used to determine a normalized detector response function (NDRF). The NDRF contains information on the combined effects of detector design, operating parameters, and the presence of 222Rn progeny. The estimation of individual plate-out or counting efficiencies is not needed, as they are appropriately included in the NDRF. The equation describing the response function can be inverted to yield the actual 222Rn concentration in terms of detector output. The technique was applied to actual indoor monitoring data and the results presented.

Air Pollutants, Radioactive↗