Search PubMed⌕ Search

Biomedical subjects

T Azami

Publications and source records attributed to T Azami.

22 records · Page 2Linked to original sources

Surgical treatment for aneurysms of the descending aorta using temporary perfusion by a centrifugal pump: clinical analysis of 33 cases.

Since 1987, 33 patients have undergone surgery at Kobe University Hospital for aneurysm of the descending aorta using left heart bypass with a heparin-coated centrifugal pump and heparin-coated tubes. Sixteen patients had true aneurysms of the descending thoracic aorta, 7 had thoracoabdominal aneurysms, and 10 had aortic dissection (DeBakey's Type III). Heat exchangers and oxygenators were not included in the bypass circuit in any of the cases. Perfusion time was from 42 to 205 min (average 90 min). Left heart bypass was established with 1 mg/kg of systemic heparinization in 5 cases, 0.5 mg/kg in 5 cases, and 0 mg/kg in 23 cases. There were no complications such as perioperative embolism, acidosis, or hypothermia. During aortic cross-clamping, the arterial pressure of the lower extremity was maintained above 70 mm Hg, but there was no relationship between the distal perfusion pressure and bypass flow. The urine output during left heart bypass was related to the distal perfusion flow by centrifugal pump. Of 23 patients who underwent bypass with less than 40 ml/kg/min of distal perfusion flow, 7 showed transient renal dysfunction postoperatively, and 1 developed postoperative renal failure. The other patients who were bypassed with over 40 ml/kg/min of pump flow stayed in the normal range of renal function. Postoperative paresis occurred in 2 patients, who were also perfused with less than 40 ml/kg/min of bypass flow. It could be concluded that left heart bypass by centrifugal pump is safe and acceptable as a circulatory support in the surgical treatment of aneurysm of the descending aorta.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Beneficial circulatory support by left heart bypass with a centrifugal (BioMedicus) pump for aneurysms of the descending thoracic aorta.

A comparative study between left heart bypass with a centrifugal (BioMedicus) pump and with a temporary external shunt was performed to assess the efficacy of distal organ perfusion in the surgical treatment of 31 patients with aneurysm of the descending thoracic aorta. Eighteen patients were supported with a centrifugal pump, and the remaining 13 were supported by temporary shunt with either a Gott shunt or a Dacron graft. Heparinless bypass with a centrifugal pump provided a significant decrease of intraoperative blood loss and blood transfusion by the combined application of Cell-Saver. The pressure difference between upper and lower extremities decreased (p < 0.05) in the centrifugal pump group even with aortic cross-clamping, and the urine output increased during operation. Among 13 patients supported with the temporary shunt, 3 had postoperative renal failure, and 2 died of it. All patients with a centrifugal pump survived without any complications. It could be concluded that the left heart bypass with a centrifugal (BioMedicus) pump was safe and was favorable for support of the distal circulation during aortic cross-clamping and to prevent ischemic complications such as renal failure and spinal cord injury.

Adult↗

[A case of left atrial ball thrombus].

A 76-year-old man admitted to one hospital complaining of transient left hemiparesis. Because of arrhythmia, he was examined by an echocardiogram and found to have an oval free-floating thrombus in his left atrium concomitant with mitral stenosis. He was transferred to our hospital for emergency surgery. On operation, a 3 x 4 cm ball thrombus was removed and diseased mitral valve was replaced with a SJM prosthetic valve. His postoperative course was relatively uneventful. Though left atrial ball thrombus is rarely found among the patients with mitral valve disease, when left atrial ball thrombus is found, immediate surgical intervention is recommended to avoid sudden death.

Heart Atria↗