Search PubMed⌕ Search

Biomedical subjects

T Akasaka

Publications and source records attributed to T Akasaka.

At least 73 records · Page 4Linked to original sources

[Effects of imaging parameters on automated cardiac flow measurement using color Doppler echocardiography].

The color Doppler echocardiographic technique has been developed for automated cardiac flow measurement (ACM). This study evaluated the effect of imaging parameters on stroke volume measurement. Cardiac output derived from the ACM method was compared with that obtained from pulsed wave Doppler in 36 patients (26 men and 10 women, mean age 54 +/- 8 years) in whom clear two-dimensional and color Doppler images of the left ventricular outflow tract were obtained. The effects of frame rate, color gain and moving target indicator (MTI) filter on cardiac output were evaluated in 13 patients (8 men and 5 women, mean age 49 +/- 6 years). Using ACM at a frame rate of 30 Hz, optimal color gain setting and high-frequency MTI filter (cutoff frequency: 915 Hz), there was an excellent correlation in cardiac output between the ACM and pulsed wave Doppler methods (stroke volume: r = 0.91, SEE = 0.32 l/min). Using ACM at a frame rate of 30, 22 and 15 Hz, the differences in stroke volume were 4.4%, 5.2% and 8.6%, respectively. When color gain was reduced, left ventricular stroke volume reduction was 12.1% (-2 dB), 18.9% (-4 dB). In contrast, there was no significant change in stroke volume measurement when color gain was increased. There was a significant decrease in stroke volume using the low-frequency MTI filter [cutoff frequency: 467 Hz (-35.6%)] and medium-frequency MTI filter [cutoff frequency: 703 Hz (-13.4%)]. Color Doppler imaging parameters are extremely important for automated assessment of cardiac output.

Automation↗

[Recurrent transient increases in liver enzymes specifically after isoflurane anesthesia].

A 69 y-old female underwent orthopedic surgery 12 times in our hospital. A variety of agents were used for anesthesia. She developed episodes of transient increase in liver enzymes only after each of three isoflurane anesthesia (GOT : 311, 292, 328 IU.l-1, GPT: 341, 264, 274 IU.l-1). We suspected drug-induced liver dysfunction, but results of a lymphocyte stimulation test were negative. We conclude that her liver dysfunction was not severe enough to cause clinical symptoms. In such susceptible patients we should be careful of our choice of anesthetic drugs.

Aged↗

[B cell acute lymphocytic leukemia with marked leukocytosis and t(3;15)(q27;q2?2)].

We report on a 16-year-old boy with B cell acute lymphocytic leukemia presenting marked leukocytosis (388,000/microliter) and resistance to multidrug chemotherapy. Karyotypical analysis revealed a novel t(3;15)(q27;q2?2) chromosomal abnormality. Because 3q27 is known to be a locus of the bcl-6 gene, which is frequently involved in B cell malignancies, molecular biological analyses were performed. Although no rearrangement was detected in 5 genes including bcl-6 on 3q27 and 2 genes on 15q2, reverse transcriptase-polymerase chain reaction procedures detected relatively strong mRNA expression of the bcl-6, smrp, dvl3, and tpml genes. These results indicate that immature leukemic cells with CD10 and CD34 positivity and rearrangement of the T cell receptor beta gene may coexist with relatively mature subpopulations that are positive for CD19 and CD20 surface markers, bcl-6 expression, and rearrangement of the gene for immunoglobulin kappa.

Adolescent↗

[Measurement of left ventricular filling by automated contour tracking method in echocardiography: comparison with radionuclide ventriculography].

Recent development of an automated contour tracking (ACT) method using the energy minimization principle provides automated edge detection and tracking of the endocardial boundary of the left ventricle, without tracing a region of interest. This study determined whether left ventricular filling indexes obtained from the ACT method provide a reliable estimate of left ventricular diastolic filling. Fourteen patients were examined by the ACT method and equilibrium radionuclide ventriculography. The volume-time wave form for ACT measurements was obtained from the 4-chamber views. Peak filling rate and time to peak filling rate measured by the ACT method were compared with those determined by radionuclide ventriculography. Peak filling rate and time to peak filling rate by the ACT method were closely correlated with those determined by radionuclide ventriculography (peak filling rate: r = 0.88, y = 0.71x + 0.36, SEE = 0.54 ml/end-diastolic volume/sec, time to peak filling rate: r = 0.89, y = 0.72x + 30.0, SEE = 0.02 msec, respectively) The ACT method is useful for the assessment of left ventricular diastolic filling.

Aged↗

[CD5 positive B cell leukemic lymphoma associated with BCL6 rearrangement].

A 59-year-old man was admitted in December 1995 because of general fatigue without lymphadenopathy. Increased abnormal lymphocytes (70%) were observed in peripheral blood. Bone marrow aspiration was a dry tap. Biopsy specimens revealed hypercellularity with infiltration of abnormal lymphocytes. Surface marker analysis of tumor cells was positive for CD5, CD19, CD20, HLA -DR, kappa, and sIgM and negative for CD10. Cytogenetic analysis disclosed a complex abnormal karyotype including t(3;22) and rearrangement of the BCL6 gene. The patient was given a diagnosis of CD5 positive B-cell lymphoma, but died in January 1997 despite repeated chemotherapy. This case was unique because BCL6 rearrangement has been reported in various types of B-cell lymphoma but rarely associated with leukemic types without lymphadenopathy.

CD5 Antigens↗

Molecular features of a new human lymphoma cell line carrying both BCL2 and BCL6 gene rearrangements.

Chromosomal translocations and/or their molecular equivalents involving the BCL6 gene on 3q27 band have been suggested to be involved in the development of non-Hodgkin's lymphoma of B-cell type (B-NHL). The rearrangement of BCL6 sometimes coexists with other translocations specific to B-NHL. Here, we report a novel B-cell lymphoma cell line, YM, established from a patient with diffuse large cell lymphoma. The YM cells expressed B-cell-associated antigens in addition to mu delta/kappa monoclonal immunoglobulin. Southern blot analysis of DNA from YM cells demonstrated rearrangement of the BCL2 gene within the 5' flanking region (5'-BCL2). Polymerase chain reaction (PCR) using primer pairs for the BCL2 exons 1 and 2, and for the constant region of the immunoglobulin kappa light chain gene (IGkappa) revealed PCR products encompassing the 5'-BCL2/IGkappa fusion, indicating that the YM cells had a t(2;18)(p11;q21) translocation. The BCL6 gene was rearranged at a point within the first intron, and cloning of the rearranged BCL6 revealed unidentified sequences juxtaposed to the 5' side of the gene. The isolated clones were mapped to 16p11.2 by high resolution fluorescence in situ chromosomal hybridization. Thus, the YM cells carried a 3q27 translocation involving 16p11.2 as a partner. Chromosome painting of metaphase spreads confirmed that the YM cells had both t(2;18) and t(3;16). Northern blot analysis using a fragment immediately adjacent to the breakpoint on 16p11.2 revealed transcriptional activity within this locus. The YM cells expressed abundant transcripts with aberrant sizes from BCL2 and BCL6, indicating deregulated overexpression of the two genes resulting from the t(2;18) and t(3;16). The YM cell line will therefore be useful to study whether BCL2 and BCL6 genes collaborate in the pathogenesis of B-NHL.

Base Sequence↗

Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography.

BACKGROUND: Coronary flow reserve has been considered an important diagnostic index of the functional significance of coronary artery stenosis. With Doppler technique, it has been assessed as the ratio of hyperemic to basal coronary flow velocity (coronary flow velocity reserve [CFVR]) by invasive or semiinvasive methods with a Doppler catheter, a Doppler guide wire, and a transesophageal Doppler echocardiographic probe. Recent technological advancement in transthoracic Doppler echocardiography (TTDE) provides measurement of coronary flow velocity in the distal portion of the left anterior descending coronary artery (LAD) and may be useful in the noninvasive CFVR measurement. The purpose of this study was to evaluate the value of CFVR determined by TTDE for the assessment of significant LAD stenosis. METHODS AND RESULTS: We studied 36 patients who underwent coronary angiography for the assessment of coronary artery disease. The study population consisted of 12 patients with significant LAD stenosis (group A) and 24 patients without significant LAD stenosis (group B). With TTDE, coronary flow velocities in the distal LAD were recorded at rest and during hyperemia induced by intravenous infusion of adenosine (0.14 mg x kg(-1) x min(-1)) under the guidance of color Doppler flow mapping. Adequate spectral Doppler recordings of coronary flow in the distal LAD for the assessment of CFVR were obtained in 34 of 36 study patients (94%). The peak and mean diastolic coronary flow velocities at baseline did not differ between groups A and B (23.6+/-10.3 versus 22.9+/-6.6 cm/s and 16.4+/-8.6 versus 14.5+/-4.0 cm/s, respectively). However, the peak and mean coronary flow velocities during hyperemia in group A were significantly smaller than those in group B (35.6+/-16.3 versus 54.2+/-16.3 cm/s and 24.7+/-13.1 versus 37.9+/-13.0 cm/s, respectively; P<.01). There were significant differences in CFVR obtained from peak and mean diastolic velocity between groups A and B (1.5+/-0.2 versus 2.4+/-0.4 and 1.5+/-0.2 versus 2.6+/-0.4, respectively; P<.001). A CFVR from peak diastolic velocity <2.0 had a sensitivity of 92% and a specificity of 82% for the presence of significant LAD stenosis. A CFVR from mean diastolic velocity <2.0 had a sensitivity of 92% and a specificity of 86% for the presence of significant LAD stenosis. CONCLUSIONS: CFVR determined by TTDE is useful in the noninvasive assessment of significant stenotic lesion in the LAD.

Adult↗

Refinement of the BCL2/immunoglobulin heavy chain fusion gene in t(14;18)(q32;q21) by polymerase chain reaction amplification for long targets.

The t(14;18)(q32;q21) translocation, involving the BCL2 gene and junctional segments (JH) of the immunoglobulin heavy chain gene (IGH), constitutes the most common chromosomal translocation in non-Hodgkin's lymphoma of B-cell type. Although the breakpoints in BCL2 are largely clustered within the major breakpoint region (MBR) and minor cluster region (mcr), it is known that some breakpoints map away from these regions, resulting in negative amplification of the junctional sequence by polymerase chain reaction (PCR) for < 1 kb targets. To circumvent this problem, we applied a novel PCR technology for long DNA targets, long-distance (LD-) PCR, to the detection of t(14;18) in clinical materials. Oligonucleotide primers were designed to be quite distant from the two known cluster regions in BCL2, and those for the corresponding IGH were complementary to the enhancer and constant regions. In all 52 cases identified as carrying BCL2/JH fusion by conventional Southern blot analysis, LD-PCR successfully amplified fragments encompassing the junctions, which were readily identifiable on ethidium bromide-stained gel. The size of the LD-PCR products ranged from 3.9 kb to 10.7 kb in MBR/IGH fusion and 1.9 kb to 16 kb in mcr/IGH fusion. Furthermore, we established an LD-PCR protocol for > 20 kb targets, which covered the intervening region between the MBR and mcr. Restriction analysis of the LD-PCR products revealed that breakpoints in 33 cases fell within the 150 bp-MBR region, and in 3 cases were within the mcr determined previously by others. In contrast, the breakpoints of the remaining 16 cases were distributed over a large region from the MBR through mcr. Nucleotide sequence analysis of a potential cluster region revealed the presence of an Alu repeat sequence. Restriction analysis of LD-PCR products with BstEII demonstrated a predominant usage of the JH6 segment (71%) at the BCL2/JH junctions. LD-PCR using primers for the constant region genes showed that class switch recombination occurred in more than 80% of the IGH genes on the der(14) chromosome. Our study showed that LD-PCR was capable of detecting virtually any t(14;18) that occurred within the approximately 30 kb region downstream of the MBR, and thus is suitable for initial diagnosis of lymphoma tissues. Furthermore, as amplified fragments obtained by the LD-PCR contained distinctive regions of BCL2 and IGH, restriction analysis and nucleotide sequencing of the products refined the characteristics of t(14;18).

Base Sequence↗

Flow dynamics of angiographically no-flow patent internal mammary artery grafts.

OBJECTIVES: This study sought to assess the flow dynamics of internal mammary artery grafts (IMAGs) in no-flow situations by use of a Doppler guide wire. BACKGROUND: Functionally no-flow and anatomically patent IMAGs have been reported by angiography in patients with a patent recipient coronary artery. METHODS: The study included 12 patients with an IMAG to the left anterior descending coronary artery (LAD) in whom no-flow patency of the graft was suspected angiographically. Thirteen patients with a normally functioning IMAG whose LAD was occluded in the proximal portion and was supplied only from the graft served as control patients. Phasic flow velocities were recorded in the distal portion of the graft and the recipient LAD using a 0.014-in., 15-MHz Doppler guide wire at rest and during hyperemia (0.14-mg/kg body weight per min intravenous adenosine infusion). RESULTS: There were no significant differences in systolic (15+/-3 vs. 19+/-6 cm/s, p = NS), diastolic (35+/-11 vs. 37+/-7 cm/s, p = NS) and time-averaged peak velocities at rest (20+/-5 vs. 21+/-5 cm/s, p = NS), during hyperemia (51+/-12 vs. 54+/-8 cm/s, p = NS) and in coronary flow velocity reserve (2.8+/-0.9 vs. 2.7+/-0.3, NS) in the native LAD in patients with a no-flow patent graft versus control patients. Within the graft, to and fro signals with systolic reversal and diastolic anterograde flow were seen in the no-flow patent grafts, although anterograde flow signals were recorded in systole and diastole in control patients. Systolic (-28+/-19 vs. 22+/-9 cm/s, p < 0.01), diastolic (18+/-17 vs. 44+/-14 cm/s, p < 0.01) and time-averaged (-2+/-6 vs. 26+/-9 cm/s, p < 0.01) peak velocities at rest were significantly smaller in the no-flow patent grafts than in control grafts. During hyperemia, anterograde flow became predominant, with a reduction in retrograde systolic flow signal and an increase in diastolic flow velocity and time-averaged peak velocity in the no-flow patent grafts, and no-flow situations disappeared temporarily. CONCLUSIONS: Functionally no-flow situations of IMAGs manifesting to and fro signals with systolic flow reversal and diastolic antegrade low flow velocity are temporary conditions in certain hemodynamic circumstances, and these grafts function as conduits during hyperemic states.

Adolescent↗

Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography: comparison with invasive technique.

OBJECTIVES: The purpose of this study was to evaluate whether transthoracic Doppler echocardiography (TTDE) can reliably measure coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the left anterior descending coronary artery (LAD) in the clinical setting. BACKGROUND: Coronary flow velocity measurement has provided useful clinical and physiologic information. Advancement in TTDE provides noninvasive measurement of CFV and CFVR in the distal LAD. METHODS: In 23 patients, CFV in the distal LAD was measured by TTDE (5 or 3.5 MHz) under the guidance of color Doppler flow mapping at the time of Doppler guide wire (DGW) examination. Coronary flow velocity in the distal LAD were measured at baseline and hyperemic conditions (intravenous administration of adenosine 0.14 mg/kg/min) by both TTDE and DGW techniques. Coronary flow velocity reserve was defined as the ratio of peak hyperemic to basal averaged peak velocity in the distal LAD. RESULTS: Clear envelopes of basal and hyperemic CFV in the distal LAD were obtained in 18 (78%) of 23 study patients by TTDE. There were excellent correlations between TTDE and DGW methods for the measurements of CFV (averaged peak velocity: r=0.97, y=0.94x + 0.40; averaged diastolic peak velocity: r=0.97, y=0.94x + 0.69; systolic peak velocities: r=0.97, y=0.91x + 0.87; diastolic peak velocity: r=0.98, y=0.95x + 1.10). Coronary flow velocity reserve from TTDE correlated highly with those from DGW examinations (r=0.94, y=0.95x + 0.21). CONCLUSIONS: Noninvasive measurement of CFV and CFVR in the distal LAD using TTDE accurately reflects invasive measurement of CFV and CFVR by DGW method.

Adenosine↗

Restricted coronary flow reserve in patients with mitral regurgitation improves after mitral reconstructive surgery.

OBJECTIVES: The purpose of this study was to assess coronary flow characteristics in patients with chronic mitral regurgitation (MR). BACKGROUND: Coronary flow reserve (CFR) has been reported to be restricted in cases with left ventricular (LV) volume overload caused by aortic regurgitation and increased LV preload. METHODS: The study populations consisted of 31 patients with nonrheumatic chronic MR. Eleven with chest pain and normal coronary arteries served as control subjects. Phasic coronary flow velocities were obtained in the proximal segment of the angiographically normal left anterior descending coronary artery at rest and during hyperemia (0.14 mg/kg/min adenosine infusion intravenously) using a 0.014-in. (0.036 cm), 15-MHz Doppler guide wire. Coronary flow reserve was obtained from the ratio of hyperemic/baseline time-averaged peak velocity (APV). Thirteen cases who underwent mitral valve reconstructive surgery were also studied 1 month after surgery. RESULTS: Compared with control subjects, CFR was significantly reduced in cases with MR (2.1+/-0.5 vs. 33+/-0.6, respectively, p < 0.01) because baseline APV was significantly greater (28+/-8 vs. 19+/-6 cm/s, respectively, p < 0.01), although maximal hyperemic APV was not significantly different (56+/-14 vs. 61+/-16 cm/s, respectively, p = NS). Significant correlations were obtained between CFR and LV end-diastolic pressure (LVEDP) (r = 0.70, p < 0.01), LV mass index (r = 0.42, p < 0.01), LV end-diastolic volume (r = 038, p = 0.04) and MR volume (r = 0.39, p = 0.03), and stepwise regression analysis showed LVEDP was the most important determinant of CFR in MR (r2 = 0.49, p < 0.0001). This restricted CFR improved significantly after mitral valve reconstructive surgery (2.1+/-0.5 vs. 3.1+/-0.6, respectively, p < 0.01) because of reduction of baseline APV (28+/-8 vs. 21+/-8 cm/s, respectively, p < 0.01). CONCLUSIONS: Coronary flow reserve is limited in cases with MR because of elevation of baseline resting flow velocity. This reduction of CFR correlates well with increase in LV preload, mass and volume overload, especially with increase in LV preload, and this restricted CFR improves after mitral valve surgery.

Adult↗

Visualization of clear echocardiographic images with near field noise reduction technique: experimental study and clinical experience.

BACKGROUND: With transthoracic echocardiography, it is sometimes difficult to obtain a clear image of the apical portion of the heart because of noise near the transducer. To reduce this artifact, we have developed a new technique (near field noise reduction, NFNR) based on the digital filtering by using radiofrequency signals. This technique may be useful for the accurate measurement of the wall thickness of the myocardium in the near field. The objectives of these studies were (1) to determine the accuracy of this new technique for the measurement of wall thickness in the experimental study and (2) to determine whether the improvement in the image quality in the apical portion can be obtained in the clinical setting by using the NFNR technique. EXPERIMENTAL STUDY: By using the NFNR technique, we measured wall thickness of three kinds of phantoms (wall thickness 9.0, 14.0, and 21.0 mm) moving at various velocities (5 to 80 mm/sec) in the water bath with artifact produced by a single probe. It was difficult to obtain clear echocardiographic images of the phantom and measure its wall thickness because of the artifact. By using the NFNR technique, on the other hand, the same phantom was clearly imaged. It was possible to measure the wall thickness of each phantom at each moving velocity with the NFNR technique. Mean differences between the echocardiographic measurement and actual value of wall thickness in each phantom model (9.0, 14.0, and 21.0 mm) were 0.04 +/- 0.58 mm, 0.09 +/- 0.58 mm, and -0.02 +/- 0.24 mm, respectively. CLINICAL STUDY: We studied 25 initial patients in whom the near field was not clearly imaged in apical views by conventional echocardiography because of near field noise. Apical four-chamber or two-chamber views were obtained with and without the NFNR technique. Two observers independently graded endocardial visualization for the 50 segments by using a three-point scale (0 = endocardium not seen, 1 = seen in part but not all of the segment, 2 = endocardium seen along entire segment). The mean segment score in the imaging with the NFNR technique was significantly higher than that without the NFNR technique (observer 1: 1.8 +/- 0.7 vs 1.2 +/- 0.8, p < 0.01; observer 2: 1.6 +/- 0.7 vs 1.2 +/- 0.8, p < 0.01). CONCLUSIONS: The newly developed NFNR technique provides clear echocardiographic images and accurate wall thickness measurement in the experimental model even when it is difficult to obtain clear images because of the artifact. This new technique will be useful in the reduction of near field noise in the clinical setting.

Echocardiography↗

Detection of t(8;14)(q24;q32) by polymerase chain reaction for long DNA targets: a report of two patients with B-cell non-Hodgkin's lymphoma.

We developed a novel technique for long-distance polymerase chain reaction (LD-PCR) to detect t(8;14)(q24;q32). LD-PCR can amplify up to 12 kb of DNA encompassing the c-MYC and constant regions of the immunoglobulin heavy chain gene. In this report, we present two patients with B-cell non-Hodgkin's lymphoma. Clinical materials obtained from these patients were examined by LD-PCR. One patient had small noncleaved cell lymphoma (case 1) and the other had diffuse large cell lymphoma (case 2). Both patients showed central nervous system involvement. LD-PCR using appropriate primer pairs and a newly available Taq polymerase for longer product synthesis detected a 9.6 kb (case 1) and a 2.4 kb (case 2) c-MYC/C gamma fusion product indicative of t(8;14) in all materials in which lymphoma cells were shown positive by microscopic examination. LD-PCR provides an advantage in rapid detection of lymphoma cells carrying t(8;14).

Adolescent↗

Expression of the PAX5/BSAP transcription factor in haematological tumour cells and further molecular characterization of the t(9;14)(p13;q32) translocation in B-cell non-Hodgkin's lymphoma.

The PAX5 gene encodes the BSAP (B-cell-specific activator protein) which is a key regulator of B-cell development and differentiation. A recurring translocation t(9;14)(p13;q32) in non-Hodgkin's lymphoma moves the PAX5 on 9p13 within close proximity of the immunoglobulin heavy chain gene (IGH). KIS-1 cell line was established from a patient with diffuse large cell lymphoma of B-cell type carrying t(9;14). We analysed PAX5/BSAP expression by Northern and Western blotting in a panel of haematological tumour cell lines with other chromosome abnormalities in comparison with that of KIS-1. PAX5 mRNA and BSAP expression were detected in all B-cell lines tested, and the high level in KIS-1 was confirmed. However, a diffuse large B-cell lymphoma cell line and an acute B-lymphoid/myeloid leukaemia cell line expressed the PAX5/BSAP at levels comparable with KIS-1. PAX5 transcripts were readily detectable in clinical materials with a wide variety of B-cell neoplasms by reverse transcriptase-mediated polymerase chain reaction (PCR). Thus, PAX5/BSAP activation in haematological tumour cells is not necessarily associated with t(9;14). Although binding sites for BSAP have been identified in the promoters of CD19, this study failed to find clear correlation between the level of PAX5/BSAP expression and that of CD19. In contrast to KIS-1 in which the E mu enhancer of IGH was juxtaposed to PAX5, cloning of t(9; 14) from another case by long-distance PCR revealed that the PAX5 promoter was linked to a Cgamma constant region in divergent orientation, suggesting that the mechanism of PAX5 activation through recombination with IGH varies among individual cases. Breakpoints on 9p13 of the two translocations were clustered upstream of PAX5, leaving the PAX5 coding region intact.

Base Sequence↗

Occult basal cell carcinoma arising in seborrheic keratosis.

The present study reports a case of an occult basal cell carcinoma that arose in seborrheic keratosis. The patient was a fifty-six-year-old male who presented with a dark brown plaque on his back. Clinically, the lesion demonstrated no nodules or ulcerations suggesting that it was malignant. However, histopathological analysis of the lesion revealed an atypical basaloid cell mass that appeared to be a solid basal cell carcinoma beneath and surrounded by a seborrheic keratosis lesion. Thus, the coexistence of basal cell carcinoma and seborrheic keratosis is possible and should be considered when a malignant change in seborrheic keratosis is apparent.

Basal Cell Carcinoma↗

Antibacterial activities and inhibitory effects of sitafloxacin (DU-6859a) and its optical isomers against type II topoisomerases.

The in vitro inhibitory effects of sitafloxacin (DU-6859a) and its three stereoisomers on bacterial DNA gyrase from Escherichia coli, topoisomerase IV from Staphylococcus aureus, and topoisomerase II from human placenta were compared. No correlation was observed between the inhibitory activities of quinolones against bacterial type II topoisomerases and those against human topoisomerase II. Sitafloxacin showed the most potent inhibitory activities against bacterial type II topoisomerases and the lowest activity against human type II topoisomerase.

Anti-Infective Agents↗

Non-Hodgkin's lymphoma involving bilateral breasts.

We describe here two cases of diffuse large cell type non-Hodgkin's lymphoma affecting the bilateral breasts. The contralateral tumor in one case appeared 17 months after the first mastectomy, whereas the bilateral tumors occurred concurrently in the other patient who was pregnant and showed widespread dissemination at initial presentation. Lymphoma cells from both cases showed the mature B-cell immunophenotype and had rearrangements of the BCL6 gene. Both patients developed progressive disease despite chemo-radiotherapy and died of leukemic manifestations. There were no apparent pathological features of lymphomas of mucosa-associated lymphoid tissue origin.

Adult↗