Search PubMed⌕ Search

Biomedical subjects

T A Ports

Publications and source records attributed to T A Ports.

At least 37 records · Page 2Linked to original sources

Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound.

BACKGROUND: Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intravascular ultrasound imaging after balloon angioplasty. METHODS AND RESULTS: Forty-one patients were studied with intravascular ultrasound after angioplasty in both peripheral and coronary arteries. Ultrasound images representing the target lesion cross section were digitized, stored on computer, and analyzed off-line. The presence of intralesional calcium and the relative size of dissection for each lesion was computed. Thirty-one patients (76%) had ultrasound evidence of significant dissection or plaque fracture immediately after balloon dilation. In 23 of 31 (74%) of the lesions, the ultrasound scans showed significant localized calcium deposits within the plaque substance. In 87% of these cases, the dissections were adjacent to the calcific portion of the vessel wall. In addition, the relative size of dissections referenced to the neolumen area were significantly larger (p less than or equal to 0.002) in the calcified vessels (27.5 +/- 12.3%) compared with the size of the dissections in lesions without calcium (11.2 +/- 5.8%). CONCLUSIONS: The presence of calcium within the vessel wall appeared to be significantly associated with both the location and size of the dissected tissue arm from the vessel wall. These data suggest that localized calcium deposits have a direct role in promoting dissection, presumably by increasing shear stresses within the plaque.

Angioplasty, Balloon, Coronary↗

Dipyridamole perfusion scintigraphy: the experience with its application in one hundred seventy patients with known or suspected unstable angina.

We evaluated the safety, accuracy, and potential clinical utility of intravenous dipyridamole perfusion scintigraphy with thallium-201 in 170 patients, 78 with suspected and 92 with known unstable angina. All had coronary angiography. Noncardiac side effects (26%), induced chest discomfort (44%), and ST segment changes (12%) were similar in the two groups. No significant arrhythmias occurred. Two patients had prolonged chest pain, both with extensive reversible image abnormalities and associated creatinine kinase-MB release. Both had elective bypass surgery. Twenty-eight patients had normal coronary arteries, and 35 had single-vessel disease. Scintigraphic per patient sensitivity and specificity were 91% and 79% with a per vessel sensitivity of 74% and a per vessel specificity of 78% without between-group differences. During a brief follow-up period, 62 patients with image abnormalities had coronary revascularization, and there were seven deaths without intergroup differences. In a similar patient group that did not have angiography, scintigraphic defects were less frequent and less extensive, revascularization was not performed, and subsequent deaths occurred less often. Dipyridamole perfusion scintigraphy is an accurate alternative to exercise testing in the evaluation of patients with unstable angina pectoris. Although not without risk, the method appears relatively safe and should be considered as a guide to diagnosis, and probably to prognosis and management.

Adult↗

Transvenous coronary ultrasound imaging. A novel approach to visualization of the coronary arteries.

BACKGROUND: Catheter-based ultrasound is a new imaging modality to examine endovascular detail in the coronary circulation. This technique requires direct placement of the catheter in the arterial segment of interest. METHODS AND RESULTS: We examined the feasibility of a less invasive approach by imaging the coronary arterial circulation by using a 5F (30 MHz) imaging catheter placed in the cardiac venous system. Using simultaneous fluoroscopy, we studied anesthetized closed-chest dogs (n = 6) and human subjects undergoing right heart catheterization (n = 11). After cannulation of the coronary sinus, the circumflex coronary artery (Cx) was visualized from the great cardiac vein (GCV), and on advancing the catheter into the anterior interventricular vein (AIV), the left anterior descending artery (LAD) was identified. Where artery and vein were parallel to each other, circular cross-sectional images of the coronary artery were obtained, whereas oblique and transverse orientation of artery to vein produced ellipsoid images or long-axis images. In the dogs, ultrasound-determined cross-sectional area of the coronary arteries (4.81 +/- 0.18 mm2) correlated closely with angiography (4.77 +/- 0.21 mm2) (r = 0.91, p less than 0.001). In humans, the Cx was readily visualized from the GCV in all subjects but because of anatomic variability, the LAD was seen less consistently from the AIV (73%). There was significant correlation between ultrasound-determined cross-sectional areas of the coronary arteries (8.25 +/- 0.34 mm2) with those from angiography (8.59 +/- 0.3 mm2) (r = 0.82, p = 0.001) in humans. In all subjects, the ultrasound transducer could be safely advanced into the AIV to the cardiac apex. Limitations of the technique include ultrasonic penetration problems, caused in part by the large size of human coronary veins and variability in artery-vein relations. CONCLUSIONS: We conclude that transvenous imaging of coronary arteries with intravascular ultrasound is a less invasive, promising new approach to the study of structure and morphology in the coronary vasculature.

Animals↗

ACC/AHA guidelines for cardiac catheterization and cardiac catheterization laboratories. American College of Cardiology/American Heart Association Ad Hoc Task Force on Cardiac Catheterization.

It is evident that the practice of cardiac catheterization has undergone, and continues to undergo, marked change. Most prominent are the recent very rapid proliferation of catheterization laboratories in general and the development of newer types of catheterization laboratory. No uniform definitions exist for these newer laboratories, so meaningful communication is difficult. The new settings are of particular concern because their location, mobility, organization, and ownership raise questions about the quality of patient care. Most difficult to address are the questions about patient safety and physician conflict of interest. There are no objective data in peer-reviewed literature to support the reported safety and cost savings of these newer settings. Through deliberations, surveys, interviews, and correspondence with the cardiology community embraced by the ACC and the AHA, the task force generally found that in freestanding catheterization laboratories, access to emergency hospitalization may be delayed, and appropriate oversight may be lacking. Additionally, opportunities for self-referral may be fostered and the perception of commercialism and entrepreneurial excess in practice created. All of these problems must be avoided. The growth and development of some freestanding facilities, particularly the mobile laboratories, do not seem to have been driven by an increased need in remote communities or for temporary support but rather almost exclusively by a desire to capture market share. Accordingly, a series of definitions, guidelines, and recommendations for the laboratories as well as for patient selection has been developed. The consensus was that a very restrictive and cautious attitude to the newer settings is appropriate at this time. The justification for development or expansion of cardiac catheterization services must be patient need. Documentation of this need must be based on objective estimates of the number of patients with known or suspected cardiac disease who meet generally accepted indications for laboratory study. Concerns about the lack of data from prospective clinical trials of patient safety in such a group necessitate a very cautious attitude toward any new catheterization services, in particular those without in-house cardiac surgical support. In view of the lack of appropriately controlled safety and need data for hospital-based, mobile, or freestanding laboratories operating without on-site (accessible by gurney) cardiac surgery facilities, the task force reaffirms the position that further development of these services cannot be endorsed at this time. In addition, there is reason for major concern that such proliferation in catheterization services may contribute to increasing costs and troubling ethical questions.

American Heart Association↗

Differentiation of abnormal blood flow patterns in coronary arteries based on Doppler catheter recordings.

Abnormal arterial blood flow patterns have been implicated as etiologic factors in thrombosis and atherosclerosis. Intravascular pulsed Doppler ultrasound techniques with fast-Fourier transform analysis offer the opportunity to measure these abnormalities. The authors hypothesized that statistical analysis of radial-directed beam spectra could be used to distinguish disturbed from non-disturbed flow and that analysis of conventional axial-directed beam spectra could then be used to distinguish laminar high-shear from laminar low-shear flow. They developed a scaled-up in-vitro model of coronary flow consisting of a glycerol/H2O test fluid flowing through an acrylic cylinder at Reynolds numbers spanning the typical physiologic range within the coronary arteries. A scaled-up Doppler catheter with the capacity for 90 degrees reflection of the beam was placed centrally. Disturbed flow was created by introducing a flow screen, and altered shear rates were produced by changing the Reynolds number. For the radial-directed beam studies, the coefficients of variation of the Doppler spectra for the disturbed flow states were significantly greater than for the nondisturbed flow states (p less than 0.01). For the axial-directed beam studies, the coefficients of variation of the Doppler spectra for the laminar high-shear flow states were significantly greater than for the laminar low-shear flow states (p less than 0.01). They conclude that abnormal blood flow patterns can be differentiated by the selective use of radial-directed and axial-directed Doppler catheter recordings.

Blood Flow Velocity↗

Regression of coronary atherosclerosis during treatment of familial hypercholesterolemia with combined drug regimens.

We conducted a randomized, controlled trial in 72 patients with heterozygous familial hypercholesterolemia to test whether reducing plasma low-density lipoprotein levels by diet and combined drug regimens can induce regression of coronary lesions. Four hundred fifty-seven lesions were measured before and after a 26-month interval by computer-based quantitative angiography. The primary outcome variable was within-patient mean change in percent area stenosis. Mean low-density lipoprotein cholesterol levels decreased from 7.32 +/- 1.5 to 4.45 +/- 1.6 mmol/L. The mean change in percent area stenosis among controls was +0.80, indicating progression, while the mean change for the treatment group was -1.53, indicating regression (P = .039 by two-tailed t test for the difference between groups). Regression among women, analyzed separately, was also significant. The change in percent area stenosis was correlated with low-density lipoprotein levels on trial. We conclude that reduction of low-density lipoprotein cholesterol levels can induce regression of atherosclerotic lesions of the coronary arteries in patients with familial hypercholesterolemia. The anticipation of benefit from treatment applies to women and men alike.

Adult↗

Can lifestyle changes reverse coronary heart disease? The Lifestyle Heart Trial.

In a prospective, randomised, controlled trial to determine whether comprehensive lifestyle changes affect coronary atherosclerosis after 1 year, 28 patients were assigned to an experimental group (low-fat vegetarian diet, stopping smoking, stress management training, and moderate exercise) and 20 to a usual-care control group. 195 coronary artery lesions were analysed by quantitative coronary angiography. The average percentage diameter stenosis regressed from 40.0 (SD 16.9)% to 37.8 (16.5)% in the experimental group yet progressed from 42.7 (15.5)% to 46.1 (18.5)% in the control group. When only lesions greater than 50% stenosed were analysed, the average percentage diameter stenosis regressed from 61.1 (8.8)% to 55.8 (11.0)% in the experimental group and progressed from 61.7 (9.5)% to 64.4 (16.3)% in the control group. Overall, 82% of experimental-group patients had an average change towards regression. Comprehensive lifestyle changes may be able to bring about regression of even severe coronary atherosclerosis after only 1 year, without use of lipid-lowering drugs.

Adult↗

Ethics in cardiovascular medicine. Task Force II: The relation of cardiovascular specialists to patients, other physicians and physician-owned organizations.

1. The American College of Cardiology acknowledges the continuum of changing societal, medical and economic perspectives affecting traditional medical ethics. Primacy of patient responsibility remains paramount to the cardiovascular specialist who at the same time should participate in the development of broader societal programs. 2. Medical decisions should be freely and jointly formulated by the patient and the cardiovascular specialist with appropriate sensitivity to such matters as mental competence, pertinent medical information and standards of care, sufficient time for contemplation, informed consent, patient right of refusal, physician right to refuse to provide inappropriate care and the right of patient, physician or third party payer to seek consultation or additional opinions. 3. The cardiovascular specialist should make a special effort to clarify and document patient preferences regarding end-of-life treatment through some form of advance directive. 4. The cardiovascular specialist bears a moral obligation to provide medical care to any patient who is HIV positive or has AIDS. 5. A conflict of interest occurs when a cardiovascular specialist places personal or financial interest ahead of the welfare and health of a patient. Professional accountability should be established through local or regional peer review. 6. The American College of Cardiology encourages and supports a renewed dedication to the principles of medical ethics, particularly in the field of cardiovascular disease. Cardiovascular specialists are encouraged to participate in the promulgation of medical ethics by teaching and by example, individually and with others.

Acquired Immunodeficiency Syndrome↗

Myocardial oxygen supply and demand.

The supply of oxygen to the myocardium is determined by coronary blood flow and oxygen carrying capacity. Coronary blood flow is a dynamic process modulated via multiple parameters. Cardiac metabolism is also affected by several factors. Under normal physiologic conditions, the demand is easily met by the supply of oxygen. In fact, there is a significant reserve on the supply side. Under certain pathologic states such as coronary artery disease, the supply of oxygen may be exhausted and an imbalance between supply and demand occurs which is translated into ischemia. The area of myocardium most susceptible to ischemia is the subendocardium due to mechanical and metabolic forces. In therapy of coronary artery disease, attention should be directed to directional changes in factors influencing supply and demand to improve blood flow to the most susceptible area.

Coronary Circulation↗

Long-term clinical results after vasodilator evaluation in patients with primary (unexplained) and secondary precapillary pulmonary hypertension: acute hemodynamic comparisons and long-term survival.

Acute hemodynamic and long-term clinical effects of 6 different vasodilators (oxygen, isoproterenol, isosorbide, phentolamine, diazoxide, and hydralazine) were evaluated in 16 consecutive patients with precapillary pulmonary hypertension. Acute symptomatic and quantitative hemodynamic responses to different vasodilators in different patients were nonuniform and unpredictable. For the whole patient group, cardiac outputs increased slightly after all drugs except oxygen. Mean pulmonary pressure decreased after oxygen and increased after isoproterenol. In general, the hemodynamic effects of vasodilators in primary and secondary precapillary pulmonary hypertension were similar. In 10 patients, an acute increase in cardiac output (4.4 to 5.4 l/min, P less than 0.005) was associated with a small but significant decrease in the mean pulmonary artery pressures (59 to 53 mm Hg, P less than 0.05) after one of the oral vasodilators, and continued treatment with this drug transiently decreased symptoms in 6 of these 10 patients. However, only 1 patient could be continued on treatment beyond 5 months. Long-term survival was related to initial New York Heart Association Functional Class (P less than 0.02) and the initial cardiac output (r2 = 0.84, P less than 0.002). Patient stratification according to these variables may be useful in future clinical trials treating patients with precapillary pulmonary hypertension.

Adult↗

Assessment of severity of coronary stenoses using a Doppler catheter. Validation of a method based on the continuity equation.

The coronary Doppler catheter has been used primarily in the measurement of coronary vasodilator reserve, most often as the ratio of peak to resting velocity in response to an intracoronary dose of papaverine. We have developed a new method based on the continuity equation using a Doppler catheter for the assessment of stenosis severity in the coronary circulation by means of quantitative velocity measurements obtained by complex spectral analysis of the Doppler signal. With this system we have been able to detect a high-velocity stenosis jet in a canine model of coronary stenosis of known cross-sectional area. Using the peak velocity obtained by complex spectral analysis, we found a strong correlation between cross-sectional areas determined by the continuity equation and known cross-sectional areas (r = 0.93, SEE = 0.23 mm2). We also found a strong correlation between the ratio of peak stenosis velocity to proximal vessel velocity and percent diameter and percent area stenosis (r = 0.91 and 0.92, respectively). When the velocity was determined with conventional zero-crossing methods for these parameters, there was no correlation between calculated and known values for cross-sectional area and percent diameter or area stenosis. Measurements of the vasodilator reserve in response to intracoronary papaverine before and after implantation of the stenosis did not correlate with any of the anatomic parameters of stenosis severity regardless of the method of signal analysis (zero-crossing or complex spectral analysis). The measurement of quantitative peak coronary velocity with a Doppler catheter using complex spectral analysis may provide an accurate method for determining the severity of a coronary stenosis.

Animals↗

Segmental evaluation of left ventricular wall motion after myocardial infarction: magnetic resonance imaging versus echocardiography.

To assess relative capabilities of magnetic resonance (MR) imaging and two-dimensional echocardiography (2DE) for evaluating regional contractile dysfunction in the left ventricle after a myocardial infarction, results from 22 concurrent MR (orthogonal-transaxial, ECG-gated, multiphasic, single-spin echo) and 2DE examinations were compared. By means of the same 11-segment LV description, MR and 2DE examinations were independently scored segment by segment for residual wall motion (point scores: 2 = normal, 1 = hypokinesia, 0 = akinesia, and -1 = dyskinesia). Significant correlation between MR and 2DE scoring was found throughout most of the left anterior descending (LAD) distribution, but right coronary artery (RCA) distribution (i.e., middle-posterior segment not well seen) could not be fully evaluated by MR imaging. When cumulative scores for the 10 segments mutually evaluated were used to derive measures of global residual LV function (i.e., score quotient [SQ] = accumulated points divided by 20 total possible points), MR SQ correlated well overall with both 2DE SQ (r = 0.82; p less than 0.05) and ejection fraction (EF) from ventriculography (r = 0.86, p less than 0.05 vs r = 0.88, p less than 0.05 for 2DE SQ compared with EF). MR evaluation of segmental wall motion was relatively stronger in the LAD distribution (MR SQ compared with 2DE SQ: r = 0.86, p less than 0.05; MR SQ compared with EF: r = 0.96, p less than 0.05) than in the RCA distribution (r = 0.06, p greater than or equal to 0.05 and r = 0.62, p greater than or equal to 0.05, respectively). For 2DE, regional variations were not as evident (2DE SQ compared with EF: r = 0.90, p less than 0.05 for LAD and r = 0.81, p less than 0.05 for RCA). For segmental evaluation of wall motion after myocardial infarction, MR imaging (transaxial, multiphasic) appears to be comparable to 2DE overall but superior in LAD distribution and inferior in RCA distribution.

Adult↗

Estimation of the functional and anatomic extent of myocardial infarction using magnetic resonance imaging.

This study assesses magnetic resonance (MR) imaging for the evaluation of both the functional and anatomic extent of damage to the left ventricle (LV) from myocardial infarction (MI). This was accomplished by blinded region-of-interest analysis of 36 MR examinations (orthogonal-transaxial, electrocardiographically-gated, multiphasic, single spin-echo) for determination of ejection fraction (EF) and relative MI volume (i.e., percent of total LV myocardial volume). Comparison of the results was then made with a measure of global residual LV function (i.e., score quotient or SQ) derived from segmental scoring of LV wall motion on a two-dimensional echocardiogram (Echo) and with an EF value from a left ventriculogram (LVG), both performed relatively concurrently with MR. Significant (p less than 0.01) overall correlations were noted between MR-EF and both Echo-SQ (r = 0.56) and LVG-EF (r = 0.78), and these relationships were relatively stronger when MI was located in the right coronary artery (RCA) than when it was found in the left anterior descending (LAD) distribution (e.g., MR-EF compared with LVG-EF: r = 0.87, p less than 0.05 for RCA; and r = 0.48, p = NS for LAD). The best expression of relative MI volume appeared to be based upon absolute volume of regionally-thinned LV wall multiplied by a correction factor for its residual contractility and then the addition of a volume correcting for the amount of regional wall thinning by necrosis (i.e., "total-Fxn" MI volume).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Evaluation of left ventricular thrombi by contrast-enhanced computed tomography and two-dimensional echocardiography.

Contrast-enhanced computed tomography (CT) was compared with 2-dimensional echocardiography (2-D echo) for evaluation of left ventricular (LV) thrombus. Thirteen patients with coronary artery disease who had LV thrombus initially documented by 1 of the 2 techniques were then studied with the other technique. The findings of the studies were concordant in 8 of 13 patients, with a similar description of the presence, location and size of the LV thrombus and associated regional LV wall abnormalities. In 5 of 13 patients, the 2 techniques produced discordant data. Of these, 2 patients had false-negative results on 2-D echo owing to poor visualization of the LV apex; 1 patient had a false-positive result on 2-D echo related to misinterpretation of a prominent papillary muscle; 2 patients had false-negative CT results, 1 related to insufficient contrast infusion. The findings demonstrate that CT is a useful technique for evaluating LV thrombus, and may be particularly helpful when 2-D echo is technically limited or equivocal.

Coronary Disease↗

Feasibility, reliability, and advantage of utilizing low contrast dose digital subtraction ventriculography in a conventional catheterization laboratory.

Ventriculography was performed with conventional biplane fluoroscopic equipment; a 1:4 dilution of contrast medium in a standard injectate volume was delivered by a power injector. The biplane images were acquired with two video tape recorders and enhanced by means of a portable digital image processor. By a simple modification and calibration of our standard light pen-computer system, volumes could be calculated and global and segmental wall motion analysis performed. Fifteen patients underwent conventional and low-dose left ventriculography. Good correlation was found in end-diastolic volume (EDV), in end-systolic volume (ESV), and in ejection fraction (EF) (r = 0.90, r = 0.93, and r = 0.92, respectively). The quality of the images enabled a frame-by-frame analysis of a cardiac cycle to be performed (r = 0.99 when compared in one patient) and regional wall motion abnormalities identified (21 out of 23 abnormal segments). Although conventional ventriculography caused a rise in left ventricular end-diastolic pressure (17 +/- 8 vs 23 +/- 11, p less than 0.002) and no change in systolic blood pressure (132 +/- 23 vs 135 +/- 23, p greater than 0.5), low-dose ventriculography had no effect on left ventricular end-diastolic pressure (18 +/- 7 vs 21 +/- 10, p greater than 0.05) and produced a rise in systolic blood pressure (144 +/- 20 vs 149 +/- 22, p less than 0.05). A system of digital enhancement that is capable of producing high-quality ventriculograms with lessened contrast morbidity can be assembled with minimal expense and adapted to any conventional catheterization laboratory.

Cardiac Catheterization↗

The effects of coronary angioplasty and reperfusion on distribution of myocardial flow.

To assess the effects of angioplasty (PTCA) and intracoronary streptokinase (ICSK) on relative myocardial perfusion, we administered 99mTc-macroaggregated albumin (MAA) to the uninvolved coronary artery before successful PTCA in 33 patients and before successful infusion of ICSK in eight patients and of 111In-MAA into the same vessel after the intervention. In 10 patients who underwent PTCA, MAA was injected into the involved, instrumented coronary artery. Computer-processed images were acquired in registry and compared. Similar scintigraphic studies were performed in six control patients and in 11 in whom planned interventions were not performed or were unsuccessful. Distribution of MAA was also compared with angiographic results and with the distribution of 201Tl on images obtained in patients at rest or on redistribution images obtained before and soon after intervention in 22 patients. In control patients and those studied after aborted or unsuccessful intervention, scintigraphic results showed excellent correlation with the angiographic anatomy and were without serial change. When MAA was injected into the uninvolved vessel, the scintigram revealed evidence of collateral perfusion with retraction of the perfusion zone from that of the involved coronary in 19 of 33 patients undergoing PTCA and in three of eight of those receiving ICSK. When MAA was injected into the involved artery, a relative increase in perfusion was seen in eight of 10 patients after PTCA. Although 30 patients demonstrated scintigraphic evidence of collateral vessels, only 10 patients had angiographic evidence of collateral circulation before intervention. The distribution of 201Tl demonstrated little change in its global pattern and regions previously supplied by collaterals were generally well perfused after intervention. Coronary collateral perfusion may be inapparent angiographically and regress rapidly after angioplasty or reperfusion. Native perfusion is generally and quickly restored after successful PTCA or ICSK infusion, which obviates the need for collaterals. After intervention, the distribution of total perfusion may not change, but its regional source may demonstrate beneficial alterations, shifting from collateral to native circulation.

Angioplasty, Balloon↗