Search PubMed⌕ Search

Biomedical subjects

Sylviane Metairon

Publications and source records attributed to Sylviane Metairon.

2 recordsLinked to original sources

Automated target preparation for microarray-based gene expression analysis.

DNA microarrays have rapidly evolved toward a platform for massively paralleled gene expression analysis. Despite its widespread use, the technology has been criticized to be vulnerable to technical variability. Addressing this issue, recent comparative, interplatform, and interlaboratory studies have revealed that, given defined procedures for "wet lab" experiments and data processing, a satisfactory reproducibility and little experimental variability can be achieved. In view of these advances in standardization, the requirement for uniform sample preparation becomes evident, especially if a microarray platform is used as a facility, i.e., by different users working in the laboratory. While one option to reduce technical variability is to dedicate one laboratory technician to all microarray studies, we have decided to automate the entire RNA sample preparation implementing a liquid handling system coupled to a thermocycler and a microtiter plate reader. Indeed, automated RNA sample preparation prior to chip analysis enables (1) the reduction of experimentally caused result variability, (2) the separation of (important) biological variability from (undesired) experimental variation, and (3) interstudy comparison of gene expression results. Our robotic platform can process up to 24 samples in parallel, using an automated sample preparation method that produces high-quality biotin-labeled cRNA ready to be hybridized on Affymetrix GeneChips. The results show that the technical interexperiment variation is less pronounced than with manually prepared samples. Moreover, experiments using the same starting material showed that the automated process yields a good reproducibility between samples.

Animals↗

[2H/H] Isotope ratio analyses of [2H5]cholesterol using high-temperature conversion elemental analyser isotope-ratio mass spectrometry: determination of cholesterol absorption in normocholesterolemic volunteers.

This paper validates the use of high-temperature conversion elemental analyser isotope-ratio mass spectrometry (TC-EA/IRMS) for measuring the [(2)H/H] enrichment of plasma [(2)H(5)]cholesterol. From a molecular point of view, the free cholesterol is initially separated from plasma by thin-layer chromatography (TLC) and then injected onto the TC-EA reactor which converts cholesterol molecules into CO and H(2) gases. The slope of the curve of the experimental mole percent excess (MPE((exp.))) versus MPE((theor.)) was very close to 1, demonstrating that no significant isotopic fractionation was observed during all processing of the samples (i.e., isolation of plasma free cholesterol by TLC and pyrolysis in the TC-EA reactor). Excellent linearity (r(2) = 0.9994, n = 4) of delta ( per thousand ) of [(2)H/H] isotopic measurements versus mole percent (MP) was assessed over the range 0 to 0.1 MP. The precision of the [(2)H/H] measurement, evaluated with two calibration points processed with TLC, was delta(2)H(V-SMOW) = -192.5 +/- 3.4 per thousand and delta(2)H(V-SMOW) = -136.9 +/- 2.9 per thousand. The standard deviations of the within-assay and between-assay repeatabilities of the analytical process, evaluated using the quality control (QC) of plasma samples, were 4.6 and 6.1 per thousand, respectively. Plant sterols are known to reduce cholesterol absorption and therefore were used as a positive control in a clinical study performed with normocholesterolemic volunteers. This present method produces biological results consistent with those already reported in the literature.

Administration, Oral↗