Search PubMed⌕ Search

Biomedical subjects

Susana Marcos

Publications and source records attributed to Susana Marcos.

21 records · Page 2Linked to original sources

Increase in corneal asphericity after standard laser in situ keratomileusis for myopia is not inherent to the Munnerlyn algorithm.

PURPOSE: Standard refractive surgery for myopia induces a shift in corneal asphericity toward positive values, resulting in an increase of spherical aberration. Analytical studies of changes in theoretical corneal shape after application of standard algorithms have yielded controversial conclusions. This study tries to resolve this controversy and discusses causes of optical degradation after refractive surgery. METHODS: Computationally, we subtracted from real preoperative corneas the ablation depth given by the Munnerlyn equation and the parabolic approximation of the Munnerlyn equation. We compared the predicted postoperative corneal asphericity (and corneal spherical aberration) with real postoperative corneal asphericities of the same eyes, after laser in situ keratomileusis (LASIK). RESULTS: Corneal asphericity increased after LASIK in real eyes, with an increase proportional to the amount of correction. This increase was not predicted by the computational application of the Munnerlyn algorithm, which predicted a slight decrease of corneal asphericity. The parabolic approximation of the Munnerlyn algorithm produced an increase in corneal asphericity that correlated with the amount of correction, but was less than the clinical findings. CONCLUSION: Potential causes for increased asphericity (radial changes in laser efficiency, epithelial healing, and biomechanical response) are discussed. These conclusions are important for the design of optimized and customized ablation algorithms, since the theoretical performance of a given ablation algorithm (ie, Munnerlyn algorithm) can differ drastically from real outcomes.

Adult↗

Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.

PURPOSE: To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS: Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measured using laser ray tracing) and corneal aberrations (estimated from a videokeratoscope) were described using Zernike terms. Root-mean-square wavefront error for both total and corneal aberrations, and through-focus Strehl ratio for the point spread function of the whole eye were used to assess optical changes induced by surgery. RESULTS: Third and higher order aberrations increased significantly after hyperopic LASIK (by a factor of 2.20 for total and 1.78 for corneal aberrations, for a 6.5-mm pupil). Spherical aberration changed to negative values (corneal average decreased by -0.85 +/- 0.48 microm and total average by -0.70 +/- 0.30 microm). Best Strehl ratio for the whole eye decreased by a factor of 1.84. Hyperopic LASIK induced larger changes than myopic LASIK, compared to an equivalent group of myopic eyes from a previous study. Induced corneal spherical aberration was six times larger after hyperopic LASIK, for a similar range of correction, and of opposite sign. As with myopic LASIK, changes in internal spherical aberration are of opposite sign to those induced on the corneal anterior surface. CONCLUSIONS: Hyperopic LASIK induced significant amounts of aberrations. The largest increase occurred in spherical aberration, which showed a shift (toward negative values) of opposite sign; increase was greater than for myopic LASIK.

Adult↗

Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses.

PURPOSE: To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs). METHODS: Corneal, total, and internal aberrations were measured in 19 eyes implanted with spherical (n=9) and aspheric (n=10) IOLs. Corneal aberrations were estimated by virtual ray tracing on corneal elevation maps, and total aberrations were measured using a second-generation laser ray tracing system. Corneal and total wave aberrations were fit to a Zernike polynomial expansion. Internal aberrations were measured by subtracting corneal from total wave aberrations. Optical performance was evaluated in terms of root-mean-square (RMS) wavefront error and Strehl ratio (estimated from the modulation transfer function). Depth-of-field was obtained from through-focus Strehl estimates from each individual eye. RESULTS: Corneal aberrations increased after IOL implantation, particularly astigmatism and trefoil terms. Third and higher order RMS (and the corresponding Strehl ratio) were significantly better in eyes with aspheric IOLs than with spherical IOLs; however, this tendency was reversed when astigmatism was included. Spherical aberration was not significantly different in eyes with aspheric IOLs, whereas it was significantly positive in eyes with spherical IOLs. Third order aberrations were not significantly different across groups. Depth-of-field was significantly larger in eyes with spherical IOLs. Spherical IOLs showed better absolute optical quality in the presence of negative defocus >1.00 D. CONCLUSIONS: Our study shows a good degree of compensation of the corneal spherical aberration in eyes implanted with aspheric IOLs, as opposed to eyes implanted with spherical IOLs. Other sources of optical degradation, both with aspheric and spherical IOLs, are non-symmetric preoperative corneal aberrations, incision-induced aberrations, and third order internal aberrations. Although best corrected optical quality is significantly better with aspheric IOLs, tolerance to defocus tended to be lower.

Adult↗