Search PubMed⌕ Search

Biomedical subjects

Sunnie Myung

Publications and source records attributed to Sunnie Myung.

10 recordsLinked to original sources

Coupling desorption electrospray ionization with ion mobility/mass spectrometry for analysis of protein structure: evidence for desorption of folded and denatured States.

A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these proteins in solution. The ion mobility data show evidence for compact ion structures [when the surface is exposed to a spray that favors retention of "nativelike" structures (50:50 water:methanol)] or elongated structures [when the surface is exposed to a spray that favors "denatured" structures (49:49:2 water:methanol:acetic acid)]. The results suggest that the DESI experiment is somewhat gentler than ESI and under appropriate conditions, it is possible to preserve structural information throughout the DESI process. Mechanisms that are consistent with these results are discussed.

Absorption↗

DL-Proline.

In the structure of DL-proline, C5H9NO2, the molecules are connected via classical intermolecular N-H...O hydrogen bonds involving the amine and carboxyl groups [N...O = 2.7129 (15) and 2.8392 (16) A], and form chains along the b-axis direction and parallel to (-101). The chains are linked into sheets via weak non-classical hydrogen bonds. The conformation of the molecule and its packing are notably different from the monohydrated DL-proline form.

Crystallization↗

Evidence for unfolding and refolding of gas-phase cytochrome C ions in a Paul trap.

The folding pathways of gas-phase cytochrome c ions produced by electrospray ionization have been studied by an ion trapping/ion mobility technique that allows conformations to be examined over extended timescales (10 ms to 10 s). The results show that the +9 charge state emerges from solution as a compact structure and then rapidly unfolds into several substantially more open structures, a transition that requires 30-60 ms; over substantially longer timescales (250 ms to 10 s) elongated states appear to refold into an array of folded structures. The new folded states are less compact than those that are apparent during the initial unfolding. Apparently, unfolding to highly open conformations is a key step that must occur before +9 ions can sample more compact states that are stable at longer times.

Cytochromes c↗

Spontaneous anti-resolution in heterochiral clusters of serine.

Chirality plays an important role in the formation and stability of noncovalent clusters which are made of chiral molecules. It is shown that clusters can exhibit a preference for both homochirality and heterochirality. Serine cluster formation is dominated by the formation of heterochiral aggregates, with the exception of the previously observed homochiral serine octamer. Thus, the majority of serine clusters lead to chiral anti-resolution, or the racemic mixing of enantiomers.

Journal Article↗

Chiral enrichment of serine via formation, dissociation, and soft-landing of octameric cluster ions.

Chiral enrichment of serine is achieved in experiments that involve formation of serine octamers starting from non-racemic serine solutions. Serine octamers were generated by means of electrospray and sonic spray ionization of aqueous solutions of d(3)-L-serine (108 Da) and D-serine (105 Da) having different molar ratios of enantiomers. A cyclic process involving the formation of chirally-enriched octameric cluster ions and their dissociation, viz. Ser(1) --> Ser(8) --> Ser(1), allows serine monomers to be regenerated with increased enantiomeric excess as shown in two types of experiments: (1) Chiral enrichment in serine was observed in MS/MS/MS experiments in a quadrupole ion trap in which the entire distribution of serine octamers formed from non-racemic solutions was isolated, collisionally activated, and fragmented. Monomeric serine was regenerated with increased enantiomeric excess upon dissociation of octamers when compared with the enantiomeric composition of the original solution. (2) Chiral enrichment was observed in the products of soft-landing of mass-selected protonated serine octamers. These ions were generated by means of electrospray or sonic spray ionization, mass selected, and collected on a gold surface using ion soft-landing. Chiral enrichment of the soft-landed serine was established by redissolving the recovered material and comparing the intensities of protonated molecular ions of d(3)-L-serine and D-serine after APCI-MS analysis. Both of these experiments showed comparable results, suggesting that formation of serine octamers depends only on the enantiomeric composition of the serine solution and that the magnitude of the chiral preference is intrinsic to octamers formed from solutions of given chiral composition.

Ions↗

Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract.

A linear octopole trap interface for an ion mobility time-of-flight mass spectrometer has been developed for focusing and accumulating continuous beams of ions produced by electrospray ionization. The interface improves experimental efficiencies by factors of approximately 50-200 compared with an analogous configuration that utilizes a three-dimensional Paul geometry trap (Hoaglund-Hyzer, C. S.; Lee, Y. J.; Counterman, A. E.; Clemmer, D. E. Anal. Chem. 2002, 74, 992-1006). With these improvements, it is possible to record nested drift (flight) time distributions for complex mixtures in fractions of a second. We demonstrate the approach for several well-defined peptide mixtures and an assessment of the detection limits is given. Additionally, we demonstrate the utility of the approach in the field of proteomics by an on-line, three-dimensional nano-LC-ion mobility-TOF separation of tryptic peptides from the Drosophila proteome.

Animals↗

Development of LC-IMS-CID-TOFMS techniques: analysis of a 256 component tetrapeptide combinatorial library.

Recent improvements in ion mobility/time-of-flight mass spectrometry techniques have made it possible to incorporate nano-flow liquid chromatography and collision induced dissociation techniques. This combination of approaches provides a new strategy for detailed characterization of complex systems--such as, combinatorial libraries. Our work uses this technology to provide a detailed analysis of a tetrapeptide library having the general form Xxx1-Xxx2-Xxx3-Xxx4 where Xxx1 = Glu, Phe, Val, Asn; Xxx2 = Glu, Phe, Val, Tyr; Xxx3 = Glu, Phe, Val, Thr; and Xxx4 = Glu, Phe, Val, Leu--a system that is expected to contain 256 different peptide sequences. The results corroborate the presence of many expected peptide sequences and indicate that some synthetic steps appear to have failed. Particularly interesting is the observation of a t-butyl protecting group on the tyrosine (Tyr) residue. It appears that most Tyr containing peptides that have this t-butyl group attached favor formation of [2M + 2H]2+ dimers, which can be readily distinguished from [M + H]+ monomers based on differences in their gas-phase mobilities. In this case, we demonstrate the use of the mobility differences between [2M + 2H]2+ and [M + H]+ ions as a signature for a failure of a synthetic step.

Amino Acid Sequence↗

Pressure assisted chelating extraction: a novel technique for digesting metals in solid matrices.

This work describes a novel technique for the digestion of metals in solid matrices. The technique is called pressure assisted chelating extraction (PACE). In a typical procedure, a solid sample is placed in a stainless steel cell and is mixed with appropriate chelating agents. Using a programmed sequence of temperature, static time, pressure and thermal equilibration available in ASE 200, the metal is removed under moderate temperature (up to 200 degrees C) and pressure (up to 3000 psi). PACE achieves metal recovery that is equivalent to that of wet digestion techniques and also provides for a clean and safe operation by substituting the strong acids commonly used during wet digestion with chelating agents. It uses less solvents and significantly less time (minutes vs. hours) for metal digestion. PACE has been validated using certified standard reference materials (SRMs) including industrial sludge, buffalo river sediments and coal fly ash. The total time required to remove metals was approximately 20 min. Results show that the PACE system provides an ideal platform for efficient, rapid, and safe metal digestion. Good agreement between measured and reference values for Pb, Mn, and Cu were found with recoveries averaging between 80 and 101% and a relative standard deviation of less than 5%. This approach may provide an alternative digestion technique for environmental samples, alloys, biological materials and samples of geological importance. The potential advantage offered lies in non-destruction of the sample, automation and the exclusion of concentrated mineral acids during the digestion procedure.

Chelating Agents↗

Nanoflow LC/ion mobility/CID/TOF for proteomics: analysis of a human urinary proteome.

A prototype linear octopole ion trap/ion mobility/tandem mass spectrometer has been coupled with a nanoflow liquid chromatography separation approach and used to separate and characterize a complicated peptide mixture from digestion of soluble proteins extracted from human urine. In this approach, two dimensions of separation (nanoflow liquid chromatography and ion mobility) are followed by collision induced dissociation (CID) and mass spectrometry (MS) analysis. From a preliminary analysis of the most intense CID-MS features in a part of the dataset, it is possible to assign 27 peptide ions which correspond to 13 proteins. The data contain many additional CID-MS features for less intense ions. A limited discussion of these features and their potential utility in identifying complicated peptide mixtures required for proteomics study is presented.

Amino Acid Sequence↗

Development of field modulation in a split-field drift tube for high-throughput multidimensional separations.

A field modulation approach for high-throughput ion mobility/time-of-flight analyses of complex mixtures has been developed using a split-field drift tube. In this approach, complex mixtures of peptides, such as those that arise from tryptic digestion of protein mixtures, are separated by nanocolumn liquid chromatography, ionized by electrospray ionization, and analyzed by ion mobility/time-of-flight techniques. The split-field drift tube allows parent ions to be separated based on differences in their low-field mobilities through the first-field region before entering the second region. For increased throughput, the magnitude of the field in the second region can be modulated throughout an LC separation in order to favor transmission of different types of ions: parent ions at low fields; fragments from primarily [M+3H]3+ peptides at moderate fields; or, fragmentation of [M+3H]3+ and [M+2H]2+ species at higher fields. We demonstrate the approach with two examples: a mixture of tryptic peptides from digestion of hemoglobin; and a complex mixture of tryptic peptides from digestion of human plasma.

Blood Proteins↗