Search PubMed⌕ Search

Biomedical subjects

Suneel Gupta

Publications and source records attributed to Suneel Gupta.

14 recordsLinked to original sources

Single- and multiple-dose pharmacokinetics of dapoxetine hydrochloride, a novel agent for the treatment of premature ejaculation.

Dapoxetine is a serotonin transporter inhibitor currently in development for the treatment of premature ejaculation. This randomized, 2-sequence, 2-treatment crossover study assessed the single- and multiple-dose pharmacokinetics of dapoxetine following once-daily administration of dapoxetine 30 mg and 60 mg to healthy male volunteers. Dapoxetine was rapidly absorbed following oral administration, with peak plasma concentrations reached approximately 1 hour after dosing; plasma concentrations after single doses of dapoxetine decreased rapidly to approximately 5% of peak concentrations by 24 hours. Elimination was biphasic, with an initial half-life of approximately 1.4 hours and a terminal half-life of approximately 20 hours. Dapoxetine showed time-invariant pharmacokinetics and dose proportionality between doses, and its pharmacokinetics was unaffected by multiple dosing. The pharmacokinetics of dapoxetine metabolites, desmethyldapoxetine and dapoxetine-N-oxide, was similarly unaffected by multiple dosing. There were no serious adverse events; the most commonly reported adverse events were diarrhea, dizziness, and nausea.

Administration, Oral↗

Effect of the proton pump inhibitor omeprazole on the pharmacokinetics of extended-release formulations of oxybutynin and tolterodine.

This study assessed the effect of the proton pump inhibitor omeprazole on the bioavailability of the extended-release formulations of oxybutynin and tolterodine. Forty-four healthy volunteers received each of 4 treatments in a 4-period crossover design. The treatments consisted of osmotically controlled extended-release oxybutynin chloride tablets at 10 mg/d or extended-release tolterodine tartrate capsules at 4 mg/d, with and without preceding treatment with 20 mg omeprazole daily for 4 days. Blood samples collected predose and at scheduled time points for 36 hours postdose were analyzed for oxybutynin and its active metabolite, N-desethyloxybutynin, or tolterodine and its active 5-hydroxymethyl metabolite, as appropriate. The AUCinfinity ratios for oxybutynin and its metabolite with and without prior omeprazole fell within the 80% to 125% range (accepted as the criterion for bioequivalence), as did those for tolterodine and its active moiety. The peak concentration ratios for oxybutynin and metabolite also conformed to this range; those for tolterodine did not. Increasing gastric pH with omeprazole does not substantially alter the pharmacokinetic properties of extended-release oxybutynin but may alter those of extended-release tolterodine.

Adolescent↗

Evaluation of the bioequivalence of two transdermal fentanyl systems following single and repeat applications.

OBJECTIVE: Transdermal delivery of fentanyl has potential benefits over slow-release morphine, being largely preferred by patients owing to the combination of effective pain relief, a good safety profile and easy, pain-free dosing. The new drug-in-adhesive Durogesic D-TRANS fentanyl Matrix Delivery System (DDTDF) has improved pharmaceutical characteristics and patient acceptability compared to the original Durogesic transdermal reservoir system (fentanyl transdermal reservoir), whilst still providing reliable and consistent delivery of fentanyl. The bioequivalence of these two systems was evaluated in two studies. RESEARCH DESIGNS AND METHODS: Eighty healthy volunteers received single (72 h) or multiple (288 h) applications of DDTDF and the transdermal reservoir system (100 microg/h) in two separate randomised, crossover bioequivalence studies. Bioequivalence was assessed by calculating the ratio of least squares means based on log-transformed data following single system application and at steady-state during the fourth application. RESULTS: Both transdermal systems were bioequivalent with respect to all tested pharmacokinetic parameters. Inter-subject variability was comparable between the two systems and was greater than intra-subject variability. Transdermal delivery was well tolerated in both groups. CONCLUSIONS: The pharmacokinetic results demonstrate that DDTDF is bioequivalent to the original fentanyl transdermal reservoir system after single and multiple applications.

Administration, Cutaneous↗

Characterisation of the pharmacokinetics of the fentanyl HCl patient-controlled transdermal system (PCTS): effect of current magnitude and multiple-day dosing and comparison with IV fentanyl administration.

INTRODUCTION: The fentanyl HCl patient-controlled transdermal system (PCTS) is a self-contained, preprogrammed, noninvasive analgesic delivery system for acute pain management. We carried out three studies with the following objectives: study I to evaluate the relationship between fentanyl absorption and the magnitude of current applied to the system; study II to determine dose-proportionality for the fentanyl HCl PCTS (25 and 40 microg); and study III to describe the effects of single- and multiple-day administration on the pharmacokinetics of fentanyl delivered by the PCTS. METHODS: All studies were open-label, crossover studies with washout periods between treatments. In study I, randomised participants (n = 36) received three of a potential five fentanyl HCl PCTS prototypes, each of which used a different current magnitude, and each of which was evaluated for 24 hours. In study II, participants (n = 40) received fentanyl (25 microg) from the PCTS for 23.33 hours, followed by fentanyl (40 microg) from the PCTS for 23.33 hours. Intravenous (IV) fentanyl (80 microg/h) was administered intermittently over 24 hours as a reference treatment in Studies I and II. In study III, participants (n = 28) received fentanyl (40 microg) from the PCTS for 20 hours, followed by fentanyl (40 microg) from the PCTS for 68 hours. Pharmacokinetic parameters, including maximum serum fentanyl concentration (Cmax), time to Cmax (tmax), area under the serum concentration-time curve (AUC) and terminal half-life (t(1/2)), were determined for each treatment. RESULTS: The amount of fentanyl absorbed from the PCTS was linearly dependent on the magnitude of current applied to the system, with a current of 170 microA resulting in the absorption of 39.5 microg of fentanyl at hour 23. Mixed-effect ANOVA indicated no significant difference (p > 0.1) in the dose-normalised pharmacokinetics of the fentanyl HCl PCTS 25 and 40 microg. No significant difference existed between the corrected AUC(0-5) of the fentanyl HCl PCTS during the single- and multiple-day treatment periods (0.40 and 0.54 microg x h/L, respectively; p = 0.133). The system was well tolerated, with headache and mild application site erythema being the most common treatment-related adverse events. CONCLUSIONS: A linear relationship exists between the amount of current applied to the fentanyl HCl PCTS and the amount of fentanyl absorbed. There is dose-proportionality in the pharmacokinetics of the fentanyl HCl PCTS 25 and 40 microg. Multiple-day administration does not affect the pharmacokinetics of the fentanyl HCl PCTS 40 microg. The system was well tolerated, even after repeated application.

Administration, Cutaneous↗

The effect of dosing frequency on the pharmacokinetics of a fentanyl HCl patient-controlled transdermal system (PCTS).

INTRODUCTION: The fentanyl HCl patient-controlled transdermal system (PCTS) is a noninvasive, needle-free, credit card-sized drug delivery system designed for the on-demand management of acute pain in a medically supervised setting. The objective of these studies was to determine the effect of dosing frequency on the pharmacokinetics of fentanyl delivered by the PCTS. METHODS: All three studies were single-centre, open-label, randomised, crossover studies. The fentanyl HCl PCTS was applied to the upper outer arm of all participants. In the first study, participants (n = 30) received three fentanyl HCl PCTS 25 microg treatments: two sequential doses hourly for 23.33 hours, six sequential doses every 3 hours for 22 hours, and 72 doses continuously over 12 hours. Participants (n = 31) in the second study received three fentanyl HCl PCTS 40 microg treatments: two sequential doses hourly over 23.33 hours, six sequential doses every 3 hours over approximately 10 hours, and 80 doses continuously over 13.33 hours. In the third study, participants (n = 28) received four fentanyl HCl PCTS 40 microg treatments: 6, 18, 36 and 80 doses over 1, 3, 6 and 13.33 hours, respectively. Naltrexone was used to block the opioid effects of fentanyl. Pharmacokinetic parameters, including maximum serum fentanyl concentration (Cmax), time to Cmax (tmax), area under the serum concentration-time curve (AUC) and terminal half-life (t(1/2)) were determined. RESULTS: In the first study, the dose-normalised AUC (AUCn) values for the 2- and 6-dose sequence treatments were not significantly different (p = 0.937), suggesting that the frequency of dosing has little effect on the amount of fentanyl absorbed; however, the AUCn for the 72-dose treatment was significantly lower than that of the other treatments (p = 0.001), which were of longer duration. The results of the second study paralleled those from the first, suggesting that the bioavailability of fentanyl delivered by the PCTS increases as a function of time and is likely to be independent of dosing frequency. Results from the third study suggested that approximately 40% of the nominal 40 microg fentanyl dose is absorbed during the first hour of treatment, with the full nominal dose absorbed after approximately 10 hours. The fentanyl HCl PCTS was well tolerated. CONCLUSION: The amount of fentanyl absorbed from the PCTS increases as a function of time and is independent of both dosing frequency and total number of doses delivered. The fentanyl HCl PCTS is generally safe and well tolerated.

Administration, Cutaneous↗

Pharmacodynamics of controlled release verapamil in patients with hypertension: an analysis using spline functions.

AIMS: To use a nonparametric approach involving longitudinal splines to model the baseline blood pressure profile and investigate the impact of this modelling on the pharmacodynamic analysis for verapamil in patients with angina or hypertension. METHODS: Dose ranging studies were conducted in patients with hypertension and with angina. Subjects received doses of 120, 180, 360 or 540 mg racemic verapamil. Pharmacodynamic data were created by subtracting the (systolic) blood pressure following active drug from the placebo response, either by direct subtraction or after modelling the baseline with a longitudinal spline model fitted to the placebo data by nonlinear mixed effects modelling. An Emax model was then used to describe the relationship between change in blood pressure and (R-)verapamil plasma concentration. RESULTS: The maximum decrease in systolic blood pressure was found to be 57.6 (+/- 26.1) mm and the C50 was 420 (+/- 349) microg/l for the data obtained by direct subtraction of the placebo data. Similar results were obtained when a cubic spline model was used to describe each individual's placebo response. However, the use of a population spline model only allowed a linear pharmacodynamic model to be fitted to the resulting data. Sparse data were created by randomly removing 66% of the data from the placebo and active phases. The population spline model gave very similar parameter estimates for the linear model applied to the sparse data to those obtained from the complete data set. CONCLUSIONS: The use of a longitudinal spline model together with nonlinear mixed effects modelling to account for baseline blood pressure response can be very powerful in a sparse data environment.

Adult↗

A population pharmacokinetic model with time-dependent covariates measured with errors.

We propose a population pharmacokinetic (PK) model with time-dependent covariates measured with errors. This model is used to model S-oxybutynin's kinetics following an oral administration of Ditropan, and allows the distribution rate to depend on time-dependent covariates blood pressure and heart rate, which are measured with errors. We propose two two-step estimation methods: the second-order two-step method with numerical solutions of differential equations (2orderND), and the second-order two-step method with closed form approximate solutions of differential equations (2orderAD). The proposed methods are computationally easy and require fitting a linear mixed model at the first step and a nonlinear mixed model at the second step. We apply the proposed methods to the analysis of the Ditropan data, and evaluate their performance using a simulation study. Our results show that the 2orderND method performs well, while the 2orderAD method can yield PK parameter estimators that are subject to considerable biases.

Biometry↗

Development of a new once-a-day formulation of methylphenidate for the treatment of attention-deficit/hyperactivity disorder: proof-of-concept and proof-of-product studies.

BACKGROUND: The duration of action of the immediate-release formulation of methylphenidate hydrochloride is short (3 to 4 hours), and 3 times daily dosing is thought to maximize effectiveness across a 12-hour day. The initial sustained-release formulations of methylphenidate had reduced efficacy compared with immediate-release methylphenidate and were not well accepted. Tachyphylaxis was hypothesized to account for the reduced effects, and an ascending drug delivery pattern was proposed to overcome this acute tolerance. METHODS: Children with attention-deficit/hyperactivity disorder were evaluated in a laboratory school to characterize onset and duration of the effect of a variety of methylphenidate regimens. In a proof-of-concept study, an experimental ascending profile was established by an initial bolus followed by small increasing doses of immediate-release methylphenidate in capsules administered every 30 minutes for 8 hours. Two proof-of-product studies of a new oral once-a-day formulation to deliver methylphenidate by an osmotic pump process based on OROS (ALZA Corp, Mountain View, Calif) technology (hereafter referred to "OROS-methylphenidate") were conducted: a pharmacokinetic study and a pharmacodynamic study. RESULTS: The experimental ascending profile matched the effect of the standard regimen of methylphenidate, 3 times daily. In the pharmacokinetic study, OROS-methylphenidate treatment produced a rapid rise followed by increasing plasma concentrations that peaked 7 to 9 hours after administration. In the pharmacodynamic study, OROS-methylphenidate treatment matched the 3 times daily dosing of methylphenidate for onset and duration of efficacy. CONCLUSIONS: These studies demonstrate the translation of a basic science finding (acute tolerance to clinical doses of methylphenidate) into clinical application (the selection of a new drug delivery pattern for methylphenidate). This approach produced a new product (OROS-methylphenidate or Concerta), which proved to have the predicted rapid onset (with 1-2 hours) and long duration of efficacy (10-12 hours) after a single administration in the morning.

Administration, Oral↗

Pharmacokinetics of controlled-release verapamil in healthy volunteers and patients with hypertension or angina.

AIMS: To study the dose-ranging population pharmacokinetics of controlled release verapamil in healthy subjects and patients with angina or hypertension. To characterize the pharmacodynamics of controlled-release verapamil in patients with hypertension. METHODS: Dose-ranging studies were conducted in healthy volunteers and patients with hypertension and angina. Subjects received doses of 120, 180, 360, or 540 mg racemic verapamil as an osmotic controlled-release formulation. A population pharmacokinetic model involving zero-order release of verapamil into the gastrointestinal tract with first-order absorption and elimination was used to describe the steady-state plasma concentration profile for R- and S-verapamil. A population sigmoid E(max) pharmacodynamic model was used to describe the effect of R- and S-verapamil on mean arterial blood pressure. RESULTS: S-verapamil had an approximate 4-fold greater apparent clearance than R-verapamil in both healthy volunteers and patients. The apparent plasma clearance of R- and S-verapamil in healthy volunteers decreased over the dose range of 120-540 mg. A similar dose-dependent decrease in apparent plasma clearance was also noted in patients. None of the patient demographic variables examined (age, total body weight, lean body weight, body mass index, and height) explained the variability in verapamil pharmacokinetics. The pharmacodynamic model describing the relationship between verapamil plasma concentration and mean arterial blood pressure indicated that the S-verapamil had a 3.6-fold lower estimated EC(50) compared to R-verapamil. CONCLUSIONS: The results from this dose-ranging pharmacokinetic investigation in healthy volunteers and patients are consistent with previous reports in healthy subjects. S-verapamil is cleared more rapidly than R-verapamil and the estimated EC(50) for S-verapamil was 3.6-fold lower than for R-verapamil. Estimated EC(50) values for R- and S-verapamil decreased with increasing age and decreasing weight.

Adult↗

New perspectives on the overactive bladder: pharmacokinetics and bioavailability.

In the United States alone, approximately 17 million men and women have symptoms of overactive bladder (OAB). For many years, oxybutynin was the drug of choice for treating OAB. Although it provided effective treatment, multiple daily doses were required, and adverse events, such as dry mouth and constipation, were decided drawbacks. Controlled drug delivery systems seen in commercially available OAB formulations alter the pharmacokinetics of antimuscarinic medications in ways that maintain efficacy and allow once-daily dosing and reduction of adverse events. In the future, OAB medications will not only incorporate new chemical entities, such as the S-enantiomer of oxybutynin, but will also use novel drug delivery technologies, including transdermal patches and bladder implants.

Administration, Cutaneous↗

Determination of an optimal dosage regimen using a Bayesian decision analysis of efficacy and adverse effect data.

One of the aims of Phase II clinical trials is to determine the dosage regimen(s) that will be investigated during a confirmatory Phase III clinical trial. During Phase II, pharmacodynamic data are collected that enables the efficacy and safety of the drug to be assessed. It is proposed in this paper to use Bayesian decision analysis to determine the optimal dosage regimen based on efficacy and toxicity of the drug oxybutynin used in the treatment of urinary urge incontinence. Such an approach results in a general framework allowing modeling, inference and decision making to be carried out. For oxybutynin, the repeated measurement efficacy and toxicity data were modeled using nonlinear hierarchical models and inferences were based on posterior probabilities. The optimal decision in this problem was to determine the dosage regimen that maximized the posterior expected utility given the prior information on the model parameters and the patient response data. The utility function was defined using clinical opinion on the satisfactory levels of efficacy and toxicity and then combined by weighting the relative importance of each pharmacodynamic response. Markov chain Monte Carlo (MCMC) methodology implemented in Win-BUGS 1.3 was used to obtain posterior estimates of the model parameters, probabilities and utilities.

Aged↗

Efficacy of a new pattern of delivery of methylphenidate for the treatment of ADHD: effects on activity level in the classroom and on the playground.

OBJECTIVES: To evaluate the pharmacodynamic effects of an experimental (EXP) delivery of methylphenidate (MPH) in children with attention-deficit/hyperactivity disorder and to investigate the situational nature of effects in laboratory classroom and playground settings. METHOD: A "sipping" study methodology was used to deliver a bolus followed by small but increasing MPH doses as the EXP regimen. A randomized, double-blind crossover design was used to compare the EXP regimen to a thrice-daily (TID) regimen and a placebo (PLA) regimen. Measures of efficacy were obtained from a Motionlogger actigraph to quantify activity and from the Swanson, Kotkin, Agler, M-Flynn, and Pelham (SKAMP) rating scale to quantify two domains of behavior (attention and deportment). RESULTS: Compared with PLA, both EXP and TID delivery of MPH produced large, significant reductions in activity and inappropriate behavior in the classroom, but the two MPH regimens did not differ in onset or duration of effects across the day. The MPH effects were situationally dependent and were smaller for the playground than for the classroom settings. CONCLUSIONS: The findings of this "proof of concept" study support the efficacy of a continuous, ascending delivery of MPH. The situational effects of MPH provide support for the theory of selective effects of stimulants, dependent on the demands of the environment.

Attention Deficit Disorder with Hyperactivity↗

Estimation and inference for a spline-enhanced population pharmacokinetic model.

This article is motivated by an application where subjects were dosed three times with the same drug and the drug concentration profiles appeared to be the lowest after the third dose. One possible explanation is that the pharmacokinetic (PK) parameters vary over time. Therefore, we consider population PK models with time-varying PK parameters. These time-varying PK parameters are modeled by natural cubic spline functions in the ordinary differential equations. Mean parameters, variance components, and smoothing parameters are jointly estimated by maximizing the double penalized log likelihood. Mean functions and their derivatives are obtained by the numerical solution of ordinary differential equations. The interpretation of PK parameters in the model and its flexibility are discussed. The proposed methods are illustrated by application to the data that motivated this article. The model's performance is evaluated through simulation.

Biometry↗