Search PubMed⌕ Search

Biomedical subjects

Sunao Mizumura

Publications and source records attributed to Sunao Mizumura.

13 recordsLinked to original sources

[Clinical usage of parallel imaging of head three-dimensional MR image for analysis of VSRAD: a comparison of imaging statistical analytic results in SENSE acquisition method shortening acquisition time versus conventional acquisition method].

Voxel-based Specific Regional Analysis System for Alzheimer's Disease (VSRAD) has developed recently as an adjunctive diagnostic tool for early Alzheimer-type dementia (ATD), using three-dimensional (3D) MRI with statistical parametric mapping (SPM), and for the objective evaluation of brain atrophy. However, it takes more than five minutes to acquire MRI data by the 3D gradient echo method (3D FFE), resulting in low-throughput performance and motion artifact. These problems interrupt the application of daily MRI study. In this study, we recruited 20 patients suspected of having ATD who then underwent continuous 3D FFE MRI studies with and without the SENSE method. It was found that the VSRAD results of MRI data with SENSE were nearly to equal to those without SENSE, in spite of the prediction of a decline in source-to-noise ratio due to the reduction factor in the SENSE method.

Aged↗

Stereotactic statistical imaging analysis of the brain using the easy Z-score imaging system for sharing a normal database.

Statistical brain imaging analysis has good objectivity and reproducibility. In Japan, statistical parametric mapping (SPM) and three-dimensional stereotactic surface projections (3D-SSP) are used nationwide as statistical imaging analysis with standard brain coordinates. They often help to interpret brain single photon emission computed tomography (SPECT) images by avoiding possible pitfalls (e.g., effects of aging, atrophy) with which clinicians are unfamiliar. However, this type of analysis presents a problem: statistical processing requires many normal subject images. The easy Z-score imaging system (eZIS) is one of the statistical analysis methods that uses SPM processing in normalization and smoothing, and it has the function of image conversion leading to statistical analysis without a control database. Therefore, statistical analysis can be used in clinical practice by sharing a prepared normal database. By unifying the image quality by processing a shared database, this program has great potential for sharing patient imaging data in many hospitals. It is expected that the eZIS will help perform detailed analysis in many functional diseases in collaborative studies. This article describes the interpretation of brain SPECT images and suggests the usefulness and potential of eZIS.

Aging↗

Clinical applications of ECG-gated myocardial perfusion SPECT.

Erectrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) can be used to assess myocardial perfusion and left ventricular function simultaneously. Various clinical applications of gated SPECT and their usefulness have been reported. The functional variables that can be determined with gated SPECT have been limited to systolic indices. Therefore, we evaluated left ventricular diastolic function with gated SPECT using data obtained from various frames per cardiac cycle and found that date generated from 32-frames are suitable for clinical use. Serial assessment of left ventricular function was also performed during bicycle exercise and dobutamine stress by means of gated SPECT using short-time data collection. These techniques, therefore, have the potential to provide useful information for evaluating myocardial conditions, such as hibernation and residual ischemia in infarct areas. Recently, we have developed a new technique for three-dimensional registration of CT coronary angiography (CTCA) and ECG-gated myocardial perfusion SPECT. This technique of registration may assist the integration of information from gated SPECT and CTCA and may have clinical application for the diagnosis of ischemic heart disease. These various applications would contribute to the development of nuclear cardiology.

Coronary Angiography↗

Evaluation of no-reflow phenomenon using 201TlCl/123I-BMIPP dual-isotope myocardial SPECT.

OBJECTIVES: We assessed the usefulness of (201)thallous chloride (TlCl)/(123)I-beta-methyl iodophenyl pentadecanoic acid (BMIPP) dual-isotope single-photon emission computed tomography (SPECT) to identify the "no-reflow phenomenon," defined as inadequate myocardial perfusion through a given segment of the coronary circulation without angiographic evidence of mechanical vessel obstruction. METHODS: (201)TlCl/(123)I-BMIPP SPECT was performed in 73 patients within approximately 1 week of initial acute myocardial infarction (AMI) after percutaneous coronary intervention (PCI). We divided the left ventricular myocardium into 17 segments on each SPECT image and scored tracer accumulation in each segment with a five-point scoring system according to the American Heart Association criteria. Total severity scores were calculated by summing the scores for all 17 segments. The mismatch ratio between myocardial perfusion and metabolism was derived from the (201)TlCl and (123)I-BMIPP total severity scores: mismatch ratio=((123)I-BMIPP total severity score -(201)TlCl total severity score)/(123)I-BMIPP total severity score. Patients were classified according to Thrombolysis in Myocardial Infarction (TIMI) flow grade as having TIMI reflow grade 0-I (TIMI 0-I reflow group; n=11), II (TIMI II reflow group; n=17) and III (TIMI III reflow group; n=45). The TIMI III reflow group was subdivided into two groups with (201)TlCl total severity scores of < or =13 (TIMI III (A) reflow group; n=36) and > or =14 (TIMI III (B) reflow group; n=9), respectively. RESULTS: The mismatch ratios in the TIMI II (0.4 +/- 0.3) and TIMI III (0.4 +/- 0.2) reflow groups were significantly higher than that in the TIMI 0-1 reflow group (0.1 +/- 0.1, p<0.05). Although coronary angiography revealed TIMI III flow after reperfusion, the mismatch ratios in the TIMI III (B) reflow group (0.2 +/- 0.1) and in the TIMI 0-I reflow group (0.1 +/- 0.1) were significantly lower than that in the TIMI III (A) reflow group (0.4 +/- 0.2, p<0.01), reflecting noneffective recanalization (so called no-reflow phenomenon). CONCLUSION: (201)TlCl/(123)I-BMIPP dual-isotope myocardial SPECT reveals the biochemical degree of the no-reflow phenomenon, whereas coronary angiography shows recanalized vascular flow only. Dual-isotope myocardial SPECT might be useful for evaluating reperfusion therapy.

Adult↗

Assessment of contractile response to dobutamine stress by means of ECG-gated myocardial SPECT: comparison with myocardial perfusion and fatty acid metabolism.

UNLABELLED: The present study assessed left ventricular performance during dobutamine stress measured using gated SPECT, and compared the results to myocardial perfusion and fatty acid metabolism. METHODS: Thirty-six patients with myocardial infarction given (99m)Tc-sestamibi or (99m)Tc-tetrofosmin were examined by gated SPECT at rest and during dobutamine stress (4-20 microg x kg(-1) x min(-1)). After acquiring data at the highest dose, 201TlCl was injected and dual-isotope SPECT was performed to assess myocardial ischemia. Thirty of 36 patients also underwent myocardial SPECT with 123I-BMIPP. Regional wall motion changes during dobutamine infusion were determined from the gated SPECT data and classified as: (1) Improvement, (2) Worsening, (3) No change, and (4) Biphasic response. For myocardial segments of each infarct area, stress 201Tl, rest (99m)Tc and (123)I-BMIPP uptakes were graded on a five-point scoring system of defects from 0 (normal) to 4 (grossly defective). RESULTS: Rest 99mTc defect score index (DSI) in No change area was significantly higher than that in Biphasic area. The ADSI (stress 201Tl - rest (99m)Tc) in Biphasic area was significantly higher than those in Improvement and No change areas. The deltaDSI (BMIPP - (99m)Tc) in Worsening area tended to be higher than that in No Change area. CONCLUSIONS: Regional contractile response to dobutamine stress analyzed by gated SPECT showed that the response in-myocardial infarct areas could be classified by rest and stress myocardial perfusion and BMIPP accumulation.

Coronary Vessels↗

Three-dimensional display in staging hemodynamic brain ischemia for JET study: objective evaluation using SEE analysis and 3D-SSP display.

The Japanese EC-IC bypass trial (JET study) was established to evaluate the validity of MCA-STA anastomosis in intracranial arterial occlusive disease aiming at stroke prevention. This study must use an objective method to reliably estimate hemodynamic brain ischemia. We devised a method of objectively classifying the severity of hemodynamic ischemia using quantitatively analytical and display software, stereotactic extraction estimation for stereotactic brain coordinates and three-dimensional stereotactic surface projections (3D-SSP). We analyzed data from 16 patients registered in the JET study. Our method offers quantitative information and 3-dimensional displays of the CBF at rest and after Diamox challenge, vascular reserve and the severity of the hemodynamic brain ischemia. We compared the maximal projection counts with ROI data from tomographic images in the anterior commissure-posterior commissure plane. The maximal counts data correlated closely with the ROI data of rest and with Diamox SPECT images (both p < 0.0001). The slopes of the linear regression line were 1.15 and 1.12, respectively. The results of this study indicated that our method could simply and objectively evaluate the severity of impaired brain circulation. This procedure should support the evaluation of hemodynamic ischemia in the JET study although validation is required by several institutions using more study subjects.

Aged↗

Radio-guided brain tumorectomy using a gamma detecting probe and a mobile solid-state gamma camera.

BACKGROUND: We herein report a technique to distinguish brain tumors from normal brain tissue during surgery using a gamma probe and a solid-state mobile gamma camera after (99m)Tc-hexakis-2-methoxy-isobutyl-isonitrile ((99m)Tc-MIBI) is administered to patients immediately before operation. METHODS: We examined 13 patients with brain tumors. Before the operation, (99m)Tc-MIBI single photon emission computed tomography (SPECT) was performed to assess accumulation in the tumors. On the day of the operation, (99m)Tc-MIBI was administered intravenously and craniotomy for tumor resection was performed. During the operation, the tumor was localized with a gamma probe and preremoval scintigraphy images were taken with a mobile gamma camera. After tumor resection was completed, residual tumors were confirmed using it again. We compared accumulation found in the preoperative SPECT images and intraoperative scintigraphy images, performed a histologic examination of adjacent tissues, and measured the dose the personnel was exposed to per operation. RESULTS: In all patients, tumors were confirmed by a gamma probe and scintigraphy during the operation. Intraoperative accumulation in tumors was significantly related to accumulation found in the preoperative (99m)Tc-MIBI SPECT images. In 9 out of 13 patients, accumulation disappeared in the postremoval scintigraphy images, and no tumor tissue was found by histologic examination. Residual tumor tissue was found in 4 patients. Average exposure of the personnel per operation was 22.9 +/- 4.0 microSv. CONCLUSION: Resection of brain tumors with a gamma probe and a mobile gamma camera was very useful since the area to be removed was easily identified and residual tumors could be detected.

Adult↗

Development of quantitative analysis method for stereotactic brain image: assessment of reduced accumulation in extent and severity using anatomical segmentation.

Through visual assessment by three-dimensional (3D) brain image analysis methods using stereotactic brain coordinates system, such as three-dimensional stereotactic surface projections and statistical parametric mapping, it is difficult to quantitatively assess anatomical information and the range of extent of an abnormal region. In this study, we devised a method to quantitatively assess local abnormal findings by segmenting a brain map according to anatomical structure. Through quantitative local abnormality assessment using this method, we studied the characteristics of distribution of reduced blood flow in cases with dementia of the Alzheimer type (DAT). Using twenty-five cases with DAT (mean age, 68.9 years old), all of whom were diagnosed as probable Alzheimer's disease based on NINCDS-ADRDA, we collected I-123 iodoamphetamine SPECT data. A 3D brain map using the 3D-SSP program was compared with the data of 20 cases in the control group, who age-matched the subject cases. To study local abnormalities on the 3D images, we divided the whole brain into 24 segments based on anatomical classification. We assessed the extent of an abnormal region in each segment (rate of the coordinates with a Z-value that exceeds the threshold value, in all coordinates within a segment), and severity (average Z-value of the coordinates with a Z-value that exceeds the threshold value). This method clarified orientation and expansion of reduced accumulation, through classifying stereotactic brain coordinates according to the anatomical structure. This method was considered useful for quantitatively grasping distribution abnormalities in the brain and changes in abnormality distribution.

Aged↗

Assessment of left ventricular function using solid-state gamma camera equipped with a highly-sensitive collimator.

PURPOSE: The solid-state gamma camera 2020tc Imager (Digirad, CA) is now commercially available and has been clinically applied. The present study evaluates the feasibility of equilibrium radionuclide ventriculography (ERNV) within a 3 min period using this camera equipped with a highly sensitive collimator. MATERIALS AND METHODS: ERNV was performed from the best septal position (left anterior oblique view) in 20 patients with cardiac disease using a single detector anger-type gamma camera equipped with a low-energy, high-resolution collimator. Immediately thereafter, we performed a second ERNV using the solid-state gamma camera equipped with a highly sensitive collimator. Acquisition periods were 10 and 3 min, respectively. RESULTS: Significantly more counts were collected from over the left ventricle with the solid-state gamma camera over 3 min than those with the anger-type gamma camera over 10 min (817.1 +/- 387.8 k counts vs. 668.2 +/- 327.4 k counts, p < 0.01). The left ventricular ejection fraction obtained from ERNV data using the solid-state gamma camera correlated closely with those acquired by the anger-type gamma camera (r = 0.94, p < 0.0001, SEE = 5.93%). CONCLUSION: The results showed that the solid-state gamma camera could assess left ventricular function with excellent data collection efficiency and high reliability.

Equipment Failure Analysis↗

Regional cerebral blood flow in vascular depression assessed by 123I-IMP SPECT.

OBJECTIVE: As the prevalence of white matter hyperintensities detected on T2 weighted MRI scans in patients with late-onset depression is higher than that in nondepressed patients, the concept of"vascular depression" (VDep) was introduced in 1997. However, the pathology of vascular depression has not been clarified. This study examined the differences in functional imaging between vascular and non-vascular depression (non-VDep). METHODS: We utilized (123)I-IMP single photon emission computed tomography (SPECT) to compare regional cerebral blood flows (rCBF) between 9 patients with VDep (Krishnan criteria) and 11 age- and sex-matched patients with non-VDep in both depressed and remitted states. RESULTS: In both VDep and non-VDep patients, mean rCBF increased significantly as depression improved, partially aided by changes in left anterior temporal blood flow. In addition, compared to non-VDep patients, the left anterior frontal rCBF for VDep patients was significantly lower in both depressed and remitted states. CONCLUSIONS: Left anterior temporal rCBF therefore appears to represent a state marker that increases as symptoms associated with late-onset depression improve, regardless of vascular changes. Furthermore, in VDep patients, left anterior frontal rCBF was low in both states compared to non-VDep patients, and might not only represent a trait marker, but also correlated with the duration of disease and likelihood of recurrence and relapse.

Aged↗

Serial assessment of left ventricular performance at rest and during bicycle exercise by ECG-gated myocardial perfusion SPECT.

UNLABELLED: The present study evaluates left ventricular performance during exercise by ECG-gated myocardial perfusion SPECT with short-time data collection. METHODS: The study population consisted of 10 healthy volunteers (Group N) and 9 patients with ischemic heart disease (Group I). Seven patients in Group I had a history of prior myocardial infarction. Rest ECG-gated SPECT was performed 40 min after an injection of Tc-99m-tetrofosmin (555-740 MBq). After resting data acquisition, Group N underwent up to two 5-min stages of exercise (75 and 125 watts) on a detachable bicycle ergometer. The Group I patients all underwent symptom-limited, maximal testing on the ergometer. ECG-gated SPECT data were acquired from both groups for 3 min at rest and during the last 3 min of each exercise stage. RESULTS: Significant increases occurred in LVEF from rest to peak stress in both groups (from 55.4 +/- 5.8 to 66.6 +/- 4.1% in group N, p < 0.0001; from 49.0 +/- 12.8 to 56.7 +/- 13.8% in Group I, p < 0.001). The LVESV values significantly decreased to peak stress in Group N (from 49.9 +/- 13.1 to 37.8 +/- 10.0 ml, p < 0.0001), whereas LVEDV did not change (from 110.6 +/- 18.9 to 112.0 +/- 19.0 ml). In contrast, the LVESV values at rest and under peak stress were similar in Group I (from 52.6 +/- 23.9 to 51.7 +/- 31.4 ml) and LVEDV in Group I at peak exercise tended to increase (from 102.8 +/- 36.7 to 111.3 +/- 39.0 ml). The changes in LVESV from rest to peak stress were significantly different between Groups N and I (-12.1 +/- 6.3 vs. -0.9 +/- 11.6 ml, p < 0.02). CONCLUSION: ECG-gated SPECT with short-time data collection can assess left ventricular function during exercise and may offer useful information for evaluating patients with ischemic heart disease.

Adult↗

[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].

UNLABELLED: Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS: Thirty-five patients with cardiac disease were enrolled. Following intravenous bolus injection of 740 MBq of 99mTc human serum albumin-DTPA, first-pass radionuclide angiography (FP) and 25-gated interval planar multi-gated blood pool scintigraphy (PMUGA) were performed for the measurement of right ventricular ejection fraction (RVEF; %) and left ventricular ejection fraction (LVEF; %), respectively. Subsequently TMUGA data set was acquired with a dual-head gamma camera (16 gated intervals). Then, alternative LVEF and RVEF were measured using TMUGA with QBS. Regional left ventricular wall motion for both PMUGA and TMUGA were assessed with a 4-point scoring system respectively. RESULTS: Automatic biventricular border detection using QBS was feasible in 27 of 35 patients (70.7%). Measurements of TMUGA LVEF and RVEF were well reproducible, with interobserver correlation coefficient of 0.98 and 0.97, respectively. TMUGA LVEF showed excellent correlation with PMUGA LVEF (r = 0.98, SEE = 3.92%). The agreement of LV wall motion score between TMUGA and PMUGA was 88.1% (214 of 243 segments), with a kappa value of 0.82. On the other hand, RVEF determined by QBS had a 12.4% average overestimate compared to the same value obtained by FP. Moreover 95% confidential interval of TMUGA RVEF (-28.8 to +4.0%) was wider than that of TMUGA LVEF (-10.7 to +10.7%). CONCLUSION: TMUGA with QBS analysis provided accurate and reproducible data for global and regional left ventricular function. However, the results of RVEF with TMUGA were not satisfying as a replacement for those with FP and modifying the algorithm were needed to improve accuracy of quantification.

Adult↗

[Cardiac pool scintigraphy using the solid-state Digirad 2020tc Imager--comparison with the conventional anger-type gamma camera using moving cardiac phantom].

UNLABELLED: Movable gamma camera, 2020tc Imager, was light miniaturized using Si photodiode as a semiconductor sensor instead of photomultiplier tubes. To validate performance of this new camera in cardiac pool scintigraphy, multigated equilibrium radionuclide ventriculography using the moving cardiac phantom was performed with 2020tc Imager and a conventional Agner-type gamma camera (PRISM 3000). METHOD: Both measured cardiac functional values were compared with the set-up ones for the phantom. Five-, 7.5-, and 10-minute-multigated data were acquired using both cameras under constant contractile condition. Constant 5-minute-multigated data acquisitions using 2020tc Imager were also carried out with varied contractile conditions. RESULTS: Measured ejection fraction (EF) derived from 2020tc Imager and an Anger-type camera were 68.5 +/- 0.6 and 70.3 +/- 1.4%, respectively. Both of these values were absolutely close to the set-up EF value of 70%. Both of end-diastolic volume and EF showed excellent correlation between set-up and measured values with the correlation coefficient of 0.97 and 0.99, respectively. CONCLUSION: This new movable camera could provide comparative cardiac functional values with an Anger-type camera and it can be useful to evaluate acute cardiac function in a coronary care unit.

Gamma Cameras↗