ING-1, a monoclonal antibody targeting Ep-CAM in patients with advanced adenocarcinomas.

PURPOSE: To determine the feasibility of administration, safety, toxicity, immunogenicity, pharmacokinetics, maximum tolerated dose, and biodistribution of ING-1, a high-affinity, Human-Engineered monoclonal antibody (heMAb) to the Mr 40,000 epithelial cell adhesion molecule Ep-CAM, in patients with advanced adenocarcinomas. EXPERIMENTAL DESIGN: ING-1 was initially administered to patients as a 1-hour intravenous infusion every 3 weeks. Toxicity and pharmacokinetic data led to the evaluation of a weekly schedule. The distribution of iodine-131 (131I)-labeled ING-1 was studied. RESULTS: Twenty-five patients received 82 courses of ING-1. Minimal toxicity was initially observed at the 0.03-, 0.10-, and 0.30-mg/kg dose levels. A patient dosed at 1.0 mg/kg developed acute pancreatitis with severe abdominal pain, nausea, and vomiting. A patient dosed at 0.3 mg/kg had an asymptomatic amylase and lipase elevation to 502 units/L and 1,627 units/L, respectively. Both patients made uncomplicated recoveries. No other dose-limiting toxicities were observed. Regardless of dose, the volume of distribution (mean +/- SEM) was 46.6 +/- 1.6 mL/kg. ING-1 clearance decreased with increasing dose. To minimize toxicity and increase dose intensity, we then administered ING-1 weekly. No significant toxicity was observed in 7 patients dosed at 0.1 mg/kg. Studies of 131I-labeled ING-1 biodistribution showed radiolocalization to colorectal and prostate cancers. A patient with colorectal cancer had an 80% decrement in the levels of carcinoembryonic antigen. CONCLUSION: The recommended dose for ING-1 is 0.10 mg/kg by intravenous infusion weekly. The absence of severe toxicity at this dose, low immunogenicity, and preliminary evidence of ING-1 tumor localization and antitumor efficacy support the further clinical development of this antibody to treat Ep-CAM-positive malignant diseases.

Adenocarcinoma↗

A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT.

PURPOSE: The conventional single-isocenter and half-beam (SIHB) technique for matching supraclavicular fields with head-and-neck (HN) intensity-modulated radiotherapy (IMRT) fields is subject to substantial dose inhomogeneities from imperfect accelerator jaw/MLC calibration. It also limits the isocenter location and restricts the useful field size for IMRT. We propose a dynamic field-matching technique to overcome these limitations. METHODS AND MATERIALS: The proposed dynamic field-matching technique makes use of wedge junctions for the abutment of supraclavicular and HN IMRT fields. The supraclavicular field was shaped with a multileaf collimator (MLC), which was orientated such that the leaves traveled along the superoinferior direction. The leaves that defined the superior field border moved continuously during treatment from 1.5 cm below to 1.5 cm above the conventional match line to generate a 3-cm-wide wedge-shaped junction. The HN IMRT fields were optimized by taking into account the dose contribution from the supraclavicular field to the junction area, which generates a complementary wedge to produce a smooth junction in the abutment region. This technique was evaluated on a polystyrene phantom and 10 HN cancer patients. Treatment plans were generated for the phantom and the 10 patients. Dose profiles across the abutment region were measured in the phantom on films. For patient plans, dose profiles that passed through the center of the neck lymph nodes were calculated using the proposed technique and the SIHB technique, and dose uniformity in the abutment region was compared. Field mismatches of +/- 1 mm and +/- 2 mm because of imperfect jaw/MLC calibration were simulated, and the resulting dose inhomogeneities were studied for the two techniques with film measurements and patient plans. Three-dimensional volumetric doses were analyzed, and equivalent uniform doses (EUD) were computed. The effect of field mismatches on EUD was compared for the two match techniques. RESULTS: For a perfect jaw/MLC calibration, dose profiles for the 10 patients in the 3-cm match zone had an average inhomogeneity range of -1.6% to +1.6% using the dynamic-matching technique and -3.7% to +3.8% according to the SIHB technique. Measurements showed that dose inhomogeneities that resulted from 1-mm and 2-mm jaw/MLC calibration errors were reduced from as large as 27% and 45% with the SIHB technique to less than 2% and 5.7% with the dynamic technique, respectively. For -1-mm, -2-mm, +1-mm, and +2-mm jaw/MLC calibration errors, respectively, treatment plans for the 10 patients yielded average dose inhomogeneities of -5.9%, -3.0%, +2.7%, and +5.8% with the dynamic technique as compared to -22.8%, -11.1%, +9.8%, and +22.1% with the SIHB technique. Calculation based on a dose-volume histogram (DVH) showed that the SIHB technique resulted in larger changes in EUD of the PTV in the junction area than did the dynamic technique. CONCLUSION: Compared with the conventional SIHB technique, the dynamic field-matching technique provides superior dose homogeneity in the abutment region between the supraclavicular and HN IMRT fields. The dynamic feathering mechanism substantially reduces dose inhomogeneities that result from imperfect jaw/MLC calibration. In addition, isocenter location in the dynamic field-matching technique can be chosen for reproducible patient setup and for adequate IMRT field size rather than being dictated by the match position. It also allows angling of the supraclavicular field to reduce the volume of healthy lung irradiated, which is impractical with the SIHB technique. In principle, this technique should be applicable to any treatment site that requires the abutment of static and intensity-modulated fields.

Calibration↗

Dose errors due to inhomogeneities in balloon catheter brachytherapy for breast cancer.

PURPOSE: To evaluate dose errors in balloon catheter brachytherapy of breast cancer due to inhomogeneities, such as iodine-containing radiographic contrast medium in the balloon, the lack of scattering medium, and the low density of lung that are not considered by commercial treatment planning systems (TPS). METHODS AND MATERIALS: By accounting for these inhomogeneities in breast/lung phantoms, Monte Carlo simulations were performed to calculate doses in the breast and lung. Doses were also calculated by a commercial TPS. The Monte Carlo doses and the TPS doses were compared along the transverse and longitudinal axes of the source. RESULTS: The Monte Carlo doses were lower by 4-10% on the prescription line than the TPS doses, depending on the concentration (5-25% by volume) of the contrast medium, and on the direction from the source. The lack of scattering medium around the breast contributes to the differences more than the attenuation by the contrast medium. Attenuation contributed approximately 1.0-4.8% at the concentrations investigated in this study. CONCLUSIONS: Current treatment planning systems, which assume a source in a large homogeneous water-equivalent medium, significantly overestimate doses in breast brachytherapy.

Brachytherapy↗

Phase 1 trial of a novel anti-CD20 fusion protein in pretargeted radioimmunotherapy for B-cell non-Hodgkin lymphoma.

Pretargeted radioimmunotherapy (PRIT) has the potential to increase the dose of radionuclide delivered to tumors while limiting radiation to normal tissues. The purpose of this phase 1 trial is to assess safety of this multistep approach using a novel tetrameric single-chain anti-CD20-streptavidin fusion protein (B9E9FP) as the targeting moiety in patients with B-cell non-Hodgkin lymphoma (NHL), and to characterize its pharmacokinetics and immunogenicity. All patients received B9E9FP (160 mg/m(2) or 320 mg/m(2)); either 48 or 72 hours later, a synthetic clearing agent (sCA) was administered (45 mg/m(2)) to remove circulating unbound B9E9FP. (90)Yttrium ((90)Y; 15 mCi/m(2))/(111)In (5 mCi)-DOTA-biotin was injected 24 hours later. There were 15 patients enrolled in the study. B9E9FP had a mean plasma half-life (T(1/2)) of 25 +/- 6 hours with a reduction in plasma level of more than 95% within 6 hours of sCA administration. (90)Y/(111)In-DOTA-biotin infusion resulted in rapid tumor localization and urinary excretion. The ratio of average tumor to whole-body radiation dose was 49:1. No significant hematologic toxicities were noted in 12 patients. There were 2 patients who had hematologic toxicity related to progressive disease. There were 2 complete remissions (90 and 325 days) and one partial response (297 days). B9E9FP performs well as the targeting component of PRIT with encouraging dosimetry, safety, and efficacy. A dose escalation trial of (90)Y-DOTA-biotin in this format is warranted.

Adult↗

Attenuation of intracavitary applicators in 192Ir-HDR brachytherapy.

Unlike the penetrating monoenergetic 662 keV gamma rays emitted by 137Cs LDR sources, the spectrum of 192Ir used in HDR brachytherapy contains low-energy components. Since these are selectively absorbed by the high-atomic number materials of which intracavitary applicators are made, the traditional neglect of applicator attenuation can lead to appreciable dose errors. We investigated the attenuation effects of a uterine applicator, and of a set of commonly used vaginal cylinders. The uterine applicator consists of a stainless steel source guide tube with a wall thickness of 0.5 mm and a density of 8.02 g/cm3, whereas the vaginal cylinders consist of the same stainless steel tube plus concentric polysulfone cylinders with a radius of 1 or 2 cm and a density of 1.40 g/cm3. Monte Carlo simulations were performed to compute dose distributions for a bare 192Ir-HDR source, and for the same source located within the applicators. Relative measurements of applicator attenuation using ion-chambers (0.125 cm3) confirmed the Monte Carlo results within 0.5%. We found that the neglect of the applicator attenuation overestimates the dose along the transverse plane by up to 3.5%. At oblique angles, the longer photon path within applicators worsens the error. We defined attenuation-corrected radial dose and anisotropy functions, and applied them to a treatment having multiple dwell positions inside a vaginal cylinder.

Algorithms↗

Comparison of biodistribution, dosimetry, and outcome from clinical trials of radionuclide-CC49 antibody therapy.

CC49 is a second-generation murine antibody with anti-TAG-72 (tumor-associated antigen) reactivity. For cancer therapy, it has the advantage of being expressed on adenocarcinomas but not on most normal tissues. CC49 has been utilized in phase I and II clinical trials at multiple institutions. Therapeutic applications to date have included (131)I-, (90)Y-, and (177)Lu-CC49, with tracer amounts of (111)In-CC49 as a dosimetry surrogate for (90)Y-CC49 therapy. Dosimetry methods and details of their description vary between studies. Biodistribution to normal organs and the effective plasma T(1/2) for various radionuclides were relatively consistent among patients with different diseases and treatment at several institutions. As expected with marrow suppression being the dose-limiting toxicity, higher doses of (177)Lu-CC49 were tolerated via intraperitoneal than IV administration. The biologic response modifier interferon enhanced TAG-72 expression and resulted in a trend of increased uptake of (131)I-CC49 by tumors. Tumor dose estimates were more variable than that of normal organs. Standardization and improved dosimetry may be helpful for comparison among patients in various studies and for establishing dose/toxicity relationships that are useful for predicting safe levels of radioimmunoconjugates.

Antibodies, Monoclonal↗

Comparison of methods for predicting myelotoxicity for non-marrow targeting I-131-antibody therapy.

Although marrow suppression is usually the dose-limiting toxicity in non-marrow ablative radionuclide therapy, calculated marrow dose has rarely been used for prescribing the radioactivity to be administered. This study assesses the correlation of myelotoxicity with mCi/m(2), patient-specific lean body dose, marrow dose from blood and body of reference man, or from blood and body using the patient-specific mass. Fourteen prostate cancer patients were treated with (131)I-CC49. Radioactivity in blood and body was determined and used to calculate their contributions to the marrow dose. Platelet nadir expressed as percentage (%) of the initial baseline was used as an indicator for myelotoxicity. Correlation between platelet nadir (%) and myelotoxicity predictors was evaluated. Platelet nadirs (%) varied substantially (5-33%) for a small range of injected radioactivity/m(2) (68-78 mCi/m(2), 2.5-2.9 GBq/m(2)). Patient-specific total body dose based on lean body mass exhibited a weak correlation (r = 0.48) with platelet nadir. Marrow dose from blood and body of reference man had a better correlation (r = 0.73). Patient-specific marrow dose from blood and body (or lean body) had a similar correlation (r = 0.74 or 0.73). Radioactivity in the remainder of the body contributed only 28% of the total dose, and thus changes to this dose component had small impact on total marrow dose. Marrow dose was a better predictor for myelotoxicity than mCi/m(2) or lean total body dose in this non-marrow targeting (131)I-antibody therapy with high blood contributions to total dose.

Antigens, Neoplasm↗

Impact of interpatient pharmacokinetic variability on design considerations for therapy with radiolabeled MAbs.

Radionuclides provide biologically-distributed vehicles for radiotherapy of multifocal cancer. Two algorithms, fixed vs individualized, have been used to prescribe the therapeutic dose of radionuclide (GBq) for the patient. The individualized method for prescribing radionuclide dose takes variations in drug pharmacokinetics into consideration, whereas the fixed method depends, in part, on documentation that there is little interpatient pharmacokinetic variability for the radiolabeled drug. Two data bases, selected to compare iodine-131((131)I) and indium-111((111)In) labeled MAbs, were used to assess interpatient pharmacokinetic variability and its impact on radionuclide dose prescription. Pharmacokinetic data obtained over 7 days for non-Hodgkins lymphoma (NHL) patients given (131)I-Lym-1 (n = 46) or (111)In-Lym-1 (n = 13) were used to obtain cumulated activities. Although (131)I-Lym-1 often showed greater interpatient variability, (111)In-Lym-1 showed several-fold variability for many tissues. Both (131)I- and (111)In-Lym-1 had sufficient interpatient variability to be significant for radionuclide dose prescription, depending on the dose-limiting critical tissue. Interpatient variability exceeded intra- and interoperator variability and intrapatient variability over time for a single institution. In summary, the magnitude of interpatient pharmacokinetic variability for (131)I- and (111)In-Lym-1 suggested that an optimally safe and effective therapy can be best achieved when radionuclide dose is influenced by estimated radiation dose, if the latter is reproducible from institution to institution.

Adult↗

A novel monoclonal antibody design for radioimmunotherapy.

The generation of chimeric and complementary-determining region (CDR) grafted monoclonal antibodies (MAb) have reduced the immunogenicity problem in the clinical application of radioimmunotherapy with monoclonal antibodies. However, humanization (Hu) has prolonged the circulation (plasma T1/2) of radiolabeled antibodies, resulting in an increased normal tissue exposure to radioactivity and greater dose-limiting bone marrow suppression. To overcome this problem, a tumor-associated glycoprotein (TAG)-72-specific CDR grafted MAb with C(H)2 domain deletion (DeltaC(H)2) was developed from the MAb CC49. Preclinical studies have demonstrated that HuCC49 DeltaC(H)2 clears more rapidly from the plasma of mice than HuCC49. This preliminary report describes the initial human experience with HuCC49 DeltaC(H)2 radiolabeled with 131I and administered to patients with metastatic colorectal carcinoma. In this pilot study we enrolled four patients who received a single infusion of 20 mg of HuCC49 DeltaC(H)2 (total protein dose) labeled with 10 mCi of 131I. Pharmacokinetics, biodistribution, dosimetry, and immune response were evaluated over 2-6 weeks. No toxicity was observed in this group of patients. A one-compartment bolus model using the non-linear (NLIN) procedures in Statistical Analysis Software (SAS; SAS, Incorporated, Cary, NC) best describes the pharmacokinetics of the 131I-HuCC49 DeltaC(H)2 with a plasma mean T1/2 of 20 +/- 3 hours, a mean residence time (MRT) of 29 +/- 4 hours and a clearance rate (Cl) of 1.5 +/- 0.1 mL/hours/kg. The whole body and marrow radiation dose estimates were 0.55 +/- 0.06 rad/mCi and 1.00 +/- 0.14 rad/mCi, respectively. All patients had positive localization of antibody to metastatic tumor sites. The 131I-HuCC49 DeltaC(H)2 biodistribution was similar to murine CC49. Three patients had no evidence of antibody response to HuCC49 DeltaC(H)2 over 6 weeks of observation, and one patient had a marginal response by week 6. Intravenous administration of HuCC49 DeltaC(H)2 is safe and well tolerated. The deleted C(H)2 construct has a shorter half-life compared with prior studies of murine CC49 but with similar biodistribution and low immunogenicity. These studies support the further clinical investigation of this agent in phase I trials by intravenous and intraperitoneal routes.

Adult↗

Dosimetric effect of respiration-gated beam on IMRT delivery.

Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study was to investigate the effect of leaf lag on the accuracy of doses delivered in gated IMRT. We first determined the effective leaf delay time by measuring the dose in a stationary phantom delivered by wedge-shaped fields. The wedge fields were generated by a DMLC at various dose rates. The so determined delay varied from 88.3 to 90.5 ms. The dosimetric effect of this delay on gated IMRT was studied by delivering wedge-shaped and clinical IMRT fields to moving and stationary phantoms at dose rates ranging from 100 to 600 MU/min, with and without gating. Respiratory motion was simulated by a linear sinusoidal motion of the phantom. An ionization chamber and films were employed for absolute dose and 2-D dose distribution measurements. Discrepancies between gated and nongated delivery to the stationary phantom were observed in both absolute dose and 2-D dose distribution measurements. These discrepancies increased monotonically with dose rate and frequency of beam interruptions, and could reach 3.7% of the total dose delivered to a 0.6 cm3 ion chamber. Isodose lines could be shifted by as much as 3 mm. The results are consistent with the explanation that beam hold-offs in gated delivery allowed the lagging leaves to catch up with the delivered monitor units each time that the beam was interrupted. Low dose rates, slow leaf speeds and low frequencies of beam interruptions reduce the effect of this delay-and-catch-up cycle. For gated IMRT it is therefore important to find a good balance between the conflicting requirements of rapid dose delivery and delivery accuracy.

Dose-Response Relationship, Radiation↗

Custom step wedge blocking using dynamic multileaf collimation for parametrial pelvic boost irradiation following brachytherapy for carcinoma of the cervix.

Carcinoma of the cervix is typically treated with a combination of intracavitary brachytherapy and external beam radiation. The external beam dose is delivered with whole pelvis fields followed by split fields that protect midline organs at risk (bladder and rectum) while treating the parametria. Three approaches have been developed to shield midline structures: a simple rectangular block, a block customized to a single brachytherapy isodose line, and a step wedge filter constructed to conform to multiple brachytherapy isodose lines. A customized step wedge filter has the potential to produce a more homogeneous dose distribution but has not achieved widespread use due to labor intensive construction. We have developed a simple, novel method to produce a custom midline step wedge using dynamic multileaf collimation (dMLC). A comparison of film measurements in a phantom with the dose calculated by a commercial treatment planning system demonstrated agreement within 3% or 3 mm. The technique requires delivery times comparable to conventional techniques.

Algorithms↗

Validation of target volume and position in respiratory gated CT planning and treatment.

The capability of a commercial respiratory gating system based on video tracking of reflective markers to reduce motion-induced CT planning and treatment errors was evaluated. Spherical plastic shells (2.8-82 cm3), simulating the gross target volume (GTV), were placed in a water-filled body phantom that was moved sinusoidally along the longitudinal axis of the CT scanner and the accelerator for +/- 1 cm at 15-30 cycle/min. During gated CT imaging, the x-ray exposure was initiated by the gating system shortly before the end of expiration (so that the imaging time would be centered at the end of expiration); it was terminated by the scanner after completion of each slice. In nongated CT images, the target appeared distorted and often broken up. GTVs volume errors ranged 16%-110% in axial scans, and 7%-36% in spiral scans. In gated CT images, the spheres appeared 3 and 5 mm longer than their actual diameters (volume errors 2%-16%), at the respective respiration rates of 15 and 20 cycles/min. At 30 cycles/min the target appeared 1 cm longer, and volume error ranged 25%-53%. During treatment, gating kept the beam on for a duration equal to the CT acquisition time of 1 s/slice. The difference in positional errors between gated CT and portal films was 1 mm, regardless the size of residual motion errors. Because of the potential of suboptimal placement of the gating window between CT imaging and treatment, an extra 1.5-2.5 mm safety margin can be added regardless of the size of residual motion error. For respiratory rates > or = 30 cycles/min, the effectiveness of gating is limited by large residual motion in the 1 s CT acquisition time.

Humans↗

Tumor control probability for selective boosting of hypoxic subvolumes, including the effect of reoxygenation.

PURPOSE: To study the effect on tumor control probability of selectively boosting the dose to hypoxic subvolumes. METHODS AND MATERIALS: A Monte Carlo model was developed that separates the tumor into two compartments, one of which receives a primary dose, and one of which receives a higher boost dose. During radiation delivery, each compartment consists of three clonogen subpopulations: those that are well oxygenated, those that are temporarily hypoxic (geometrically transient hypoxia), and those that are permanently hypoxic (geometrically stable hypoxia). The spatial location of temporary hypoxia within the tumor volume varies over time, whereas, the spatial location of permanent hypoxia does not. The effect of reoxygenation was included. Clonogen proliferation was not included in the model. RESULTS: A modest boost dose (120%-150% of the primary dose) increases tumor control probability to that found in the absence of permanent hypoxia. The entire hypoxic subvolume need not be included to obtain a significant benefit. However, only tumors with a geometrically stable hypoxic volume will have an improved control rate. CONCLUSIONS: Tumors with an identifiable geometrically stable hypoxic volume will have an improved control rate if the dose to the hypoxic volume is escalated. Further work is required to determine the spatiotemporal evolution of the hypoxic volumes before and during the course of radiotherapy.

Algorithms↗

Model prediction of treatment planning for dose-fractionated radioimmunotherapy.

BACKGROUND: Clinical trials of radioimmunotherapy (RIT) often use dose fractionation to reduce marrow toxicity. The dosing scheme can be optimized if marrow and tumor cell kinetics following radiation exposure are known. METHODS: A mathematic model of tumor clonogenic cell kinetics was combined with a previously reported marrow cell kinetics model that included marrow stromal cells, progenitor cells, megakaryocytes, and platelets. Reported values for murine tumor and marrow cellular turnover rates and radiosensitivity were used in the model calculation. RESULTS: Given a tolerated level of thrombocytopenia, there is a fractionation scheme in which total radioactive dose administration can be maximized. Isoeffect doses that had different numbers of fractions and total radioactivity, but induced identical platelet nadirs of 20%, were determined. Assuming identical tumor uptake for all dose fractions, six tumor types were examined: early-responding tumors, late-responding tumors, and tumors that lacked a late-responding effect, with either constant or accelerated doubling time. For most tumor types, better tumor control (tumor growth delay and nadir of survival fraction) was predicted for a dosing scheme in which total radioactive dose was maximized. For late-responding tumors with accelerated doubling time, tumor growth delay increased, but the nadir of survival fraction became shallower as the number of fractions increased. CONCLUSIONS: A mathematic model has been developed that allows prediction of the nadir and duration of thrombocytopenia as well as tumor clonogenic cell response to various RIT doses and fractionation schemes. Given a maximum tolerated level of thrombocytopenia, the model can be used to determine a dosing scheme for optimal tumor response.

Abnormalities, Radiation-Induced↗

Assaying 192Ir line sources using a standard length well chamber.

The strength of intravascular 192Ir sources is typically measured by the manufacturer before shipment, and treatment planning is based on that assay. However, in-house verification of source strength is required at some institutions by state law or internal policy, is recommended by the AAPM TG 60 report on intravascular brachytherapy, and is considered a necessity by many medical physicists. To accommodate the long sources used in intravascular therapy, special well chambers with extended regions of constant response have been designed. To allow assays using a widely available standard well chamber, we have measured its position dependent sensitivity and derived from it a table of correction factors that account for the extended length of intravascular sources. An experimental verification shows that application of these correction factors yields assays with sufficient accuracy for routine quality assurance tests.

Brachytherapy↗

Improved prediction of myelotoxicity using a patient-specific imaging dose estimate for non-marrow-targeting (90)Y-antibody therapy.

UNLABELLED: For calculation of radiation dose to the marrow, standard dosimetry for radiopharmaceuticals that do not bind to the marrow includes dose contributions from radioactivity in blood and the remainder of the body. For a pure beta -emitter such as (90)Y, marrow dose is usually determined by the blood contribution. However, myelotoxicity from (90)Y-antibody therapy often correlates poorly with marrow dose estimated using the blood method. This study proposes a method to address 2 possible factors affecting marrow dose estimates. These include (a) recycled (90)Y in bone/marrow space after (90)Y-antibody has been processed in the liver and (b) use of the marrow mass of Reference Man for individual patients. METHODS: Thirty-three patients with advanced non-small cell lung cancer were treated with (90)Y-anti-TAG-72 murine antibody (CC49). TAG-72 is often expressed in epithelial-derived tumors but not in normal marrow. (111)In-CC49 was used as a tracer. The marrow doses from blood were calculated on the basis of radioactivity concentrations in blood. Marrow dose in the lumbar vertebrae was estimated from images for (111)In-CC49 uptake in L2-L4. In 20 patients who had CT images, trabecular bone volumes of L2-L4 were measured from CT images to estimate patient-specific marrow mass in L2-L4. The fraction of baseline platelet counts at nadir was used as an indicator of myelotoxicity. RESULTS: Marrow dose per unit injected radioactivity estimated from blood was lower than that from L2-L4 uptake values. Prediction of myelotoxicity using marrow dose estimated from blood was poorer than that using injected dose per body surface area (GBq/m(2)) (r = 0.31 vs. 0.51). Prediction was improved using marrow dose estimated from L2-L4 uptake, assuming the marrow mass of Reference Man (r = 0.67 for n = 33; r = 0.70 for n = 20). Prediction was worse if reference marrow mass was adjusted by body weight (r = 0.56 for n = 33; r = 0.63 for n = 20). Prediction was not improved if adjusted by body surface area or lean body mass but was improved if adjusted by height (r = 0.72 for n = 33; r = 0.78 for n = 20). The best prediction was obtained (r = 0.85 for n = 20) using patient-specific L2-L4 marrow mass estimated from CT. CONCLUSION: Marrow dose estimated from the blood radioactivity method was not a good predictor of myelotoxicity for non-marrow-targeting (90)Y-antibody therapy. Thrombocytopenia in this group of patients correlated much better with dose estimated from lumbar vertebrae imaging and patient-specific marrow mass than with that estimated from GBq/m(2) or standard marrow dose based on blood.

Adult↗

A Phase I study of combined modality (90)Yttrium-CC49 intraperitoneal radioimmunotherapy for ovarian cancer.

PURPOSE: The purpose of this study was to determine the feasibility and maximum tolerated dose of (90)Yttrium-CC49 ((90)Y-CC49) as the radioimmunotherapy (RIT) component of an i.p. combined modality treatment for recurrent ovarian cancer. EXPERIMENTAL DESIGN: A Phase I trial of (90)Y-CC49 RIT was conducted in ovarian cancer patients who had persistent or recurrent intra-abdominal disease, had failed one or two prior chemotherapy regimens, and demonstrated TAG-72 expression. Patients were treated with a previously established combined modality treatment protocol of s.c. IFN alpha2b, i.p. paclitaxel, and increasing dosages of i.p. (90)Y-CC49. Patients were monitored for toxicity, generation of human antimouse antibody response, and clinical efficacy. RESULTS: Twenty eligible patients were treated per study specifications. All patients had been treated with debulking and paclitaxel/carboplatin-based chemotherapy at initial diagnosis. The patients included 11 patients with persistent disease at the time of second look laparotomy and 9 patients with delayed recurrence. Patients were treated with i.p. (90)Y-CC49 given in combination with s.c. IFN alpha2b (dose of 3 x 10(6) units for a total of four doses) and i.p. paclitaxel (dose of 100 mg/m(2)). RIT treatment was associated with primarily hematological toxicity. The maximum tolerated dose of i.p. (90)Y-CC49 was established at 24.2 mCi/m(2) in this combined regimen. Of nine patients with measurable disease, two had partial responses lasting 2 and 4 months. Of 11 patients with nonmeasurable disease, median time to progression was 6 months in 7 patients who recurred; 4 of these patients remain no evidence of disease at 9+, 18+, 19+, and 23+ months. CONCLUSIONS: (90)Yttrium-CC49-based RIT in combination with IFN alpha2b and i.p. paclitaxel is feasible and well tolerated at a dose of < or =24.2 mCi/m(2).

Adenocarcinoma↗