Search PubMed⌕ Search

Biomedical subjects

Steven A Jones

Publications and source records attributed to Steven A Jones.

13 recordsLinked to original sources

Progress toward the culture and transformation of chicken blastodermal cells.

Chicken blastodermal cells can be cultured for short periods of time and retain the ability to contribute to somatic and germline tissues when injected into gamma-irradiated stage X embryos. Such a method has yet to yield a germline transgenic bird, in part due to the low rate of transgene integration into the avian genome. In addition, the short culture period precludes the identification and expansion of those cells that carry an integrated transgene. In this study, two methods were developed that produced blastodermal cells isolated from stage X Barred Plymouth Rock embryos bearing an integrated transgene. Addition of chick embryo extract to the culture medium enabled expansion of single colonies for multiple passages. Southern blot analysis indicated that the transgenes had integrated as a single copy in most of the clones. Cells from passaged, transgenic embryo cells were injected into irradiated stage X White Leghorn embryos, producing hatched chicks that bore the donor cells in their somatic tissues. Transgene sequences were detected in sperm DNA; however, breeding of chimeras did not result in germline transmission of the transgene, indicating that the contribution of the transgenic cells to the germline was either nonexistent or very low.

Animals↗

Mathematical model for pressure losses in the hemodialysis graft vascular circuit.

Stenosis-induced thrombosis and abandonment of the hemodialysis synthetic graft is an important cause of morbidity and mortality. The graft vascular circuit is a unique low-resistance shunt that has not yet been systematically evaluated. In this study, we developed a mathematical model of this circuit. Pressure losses (deltaPs) were measured in an in vitro experimental apparatus and compared with losses predicted by equations from the engineering literature. We considered the inflow artery, arterial and venous anastomoses, graft, stenosis, and outflow vein. We found significant differences between equations and experimental results, and attributed these differences to the transitional nature of the flow. Adjustment of the equations led to good agreement with experimental data. The resulting mathematical model predicts relations between stenosis, blood flow, intragraft pressure, and important clinical variables such as mean arterial blood pressure and hematocrit. Application of the model should improve understanding of the hemodynamics of the stenotic graft vascular circuit.

Animals↗

Biocompatibility of layer-by-layer self-assembled nanofilm on silicone rubber for neurons.

Electrostatic layer-by-layer (LbL) self-assembly, a novel method for ultrathin film coating has been applied to silicone rubber to encourage nerve cell adhesion. The surfaces studied consisted of precursor layers, with alternating cationic poly(ethyleneimine) (PEI) and anionic sodium poly(styrenesulfonate) (PSS) followed by alternating laminin and poly-D-lysine (PDL) layers or fibronectin and PDL layers. Film growth increased linearly with the number of layers. Every fibronectin/PDL and laminin/PDL bilayer was 4.4 and 3.5 nm thick, respectively. All layers were more hydrophilic than the unmodified silicone rubber surface, as determined from contact angle measurements. Of the coatings studied, a PDL layer was the most hydrophilic. A multilayer film with composition [PSS/PEI]3+[fibronectin/PDL]4 or [PSS/PEI]3+[laminin/PDL]4 was highly favorable for neuron adhesion, in contrast to bare silicone rubber substrate. The film coated on silicone rubber is biocompatible for cerebellar neurons with active viability, as shown by lactate dehydrogenase (LDH) assay and fluorescence cellular metabolism observations. These results demonstrate that LbL self-assembly provides an effective approach to apply films with nanometer thickness to silicone rubber. Such only few nanometer thick films are biocompatible with neurons, and may be used to coat devises for long-term implant in the central nervous system.

Animals↗

Nano-encapsulation of furosemide microcrystals for controlled drug release.

Furosemide microcrystals were encapsulated with polyions and gelatin to control the release of the drug in aqueous solutions. Charged linear polyions and gelatin were alternatively deposited on 5-microm drug microcrystals through layer-by-layer (LbL) assembly. Sequential layers of poly(dimethyldiallyl ammonium chloride) (PDDA) and poly(styrenesulfonate) (PSS) were followed by adsorption of two to six gelatin/PSS bilayers with corresponding capsule wall thicknesses ranging from 45 to 115 nm. The release of furosemide from the coated microparticles was measured in aqueous solutions of pH 1.4 and 7.4. At both pH values, the release rate of furosemide from the encapsulated particles was reduced by 50-300 times (for capsules coated with two to six bilayers) compared to uncoated furosemide. The results provide a method of achieving prolonged drug release through self-assembly of polymeric shells on drug microcrystals.

Crystallization↗

In vivo validation of glucose pump test for measurement of hemodialysis access flow.

BACKGROUND: The glucose pump test (GPT) is a recently introduced method of measuring hemodialysis access blood flow (Qa). A validation of GPT during dialysis has not yet been done, and performance characteristics of the method have not yet been fully analyzed. METHODS: The authors studied 33 patients (25 synthetic grafts, 8 autogenous arteriovenous fistulae). Qa measurements by ultrasound dilution (UD) and GPT were done in triplicate during dialysis. In GPT, a baseline blood sample (C(1)) was obtained, followed by infusion of a 10% glucose solution (C(i)) through the arterial needle into the access at 16 mL/min (Q(i)). After 11 seconds, a downstream blood sample (C(2)) was aspirated from the venous needle. C(1) and C(2) glucose were measured by glucometer. Qa was computed by the equation: Qa = Q(i)(C(i) - C(2))/(C(2) - C(1)). A model of the access vascular circuit was used to determine the influence of C(2) aspiration on the Qa measurement. RESULTS: Mean Qa was 1413 mL/min by UD versus 1,496 mL/min by GPT (P = 0.11). There was a strong linear correlation between the 2 methods (r = 0.905; P <0.001). The pooled coefficient of variation was 6.4% for UD and 9.6% for GPT. The circuit model showed that aspiration of C(2) causes an increase in Qa (DeltaQa) that depends on the aspiration rate (Q(ASP)) and fraction of resistance in the circuit that is downstream to the venous needle: DeltaQa = Q(ASP)(Downstream resistance)/(Total resistance). The model predicts the overestimate is approximately 62 mL/min for grafts and 120 mL/min for fistulae but may vary depending on the balance of resistances upstream and downstream to the venous needle. CONCLUSION: This study shows that GPT closely correlates with UD, and the method has adequate precision. GPT is an inexpensive method that may help make Qa measurements more widely available than previously possible.

Arteriovenous Shunt, Surgical↗

Coating and selective deposition of nanofilm on silicone rubber for cell adhesion and growth.

A recently developed method for surface modification, layer-by-layer (LbL) assembly, has been applied to silicone, and its ability to encourage endothelial cell growth and control cell growth patterns has been examined. The surfaces studied consisted of a precursor, with alternating cationic polyethyleneimine (PEI) and anionic sodium polystyrene sulfonate (PSS) layers followed by alternating gelatin and poly-D-lysine (PDL) layers. Film growth increased linearly with the number of layers. Each PSS/PEI bilayer was 3 nm thick, and each gelatin/PDL bilayer was 5 nm thick. All layers were more hydrophilic than the unmodified silicone rubber surface, as determined from contact angle measurements. The contact angle was primarily dictated by the outermost layer. Of the coatings studied, gelatin was the most hydrophilic. A film of (PSS/PEI)4/(gelatin/PDL)4/ gelatin was highly favorable for cell adhesion and growth, in contrast to films of (PSS/PEI)8 or (PSS/PEI)8/PSS. Cell growth patterns were successfully controlled by selective deposition of microspheres on silicone rubber, using microcontact printing with a silicone stamp. Cell adhesion was confined to the region of microsphere deposition. These results demonstrate that the LbL self-assembly technique provides a general approach to coat and selectively deposit films with nanometer thickness on silicone rubber. Furthermore, they show that this method is a viable technique for controlling cellular adhesion and growth.

Animals↗

Biomedical applications of electrostatic layer-by-layer nano-assembly of polymers, enzymes, and nanoparticles.

The introduction of electrostatic layer-by-layer (LbL) self-assembly has shown broad biomedical applications in thin film coating, micropatterning, nanobioreactors, artificial cells, and drug delivery systems. Multiple assembly polyelectrolytes and proteins are based on electrostatic interaction between oppositely charged layers. The film architecture is precisely designed and can be controlled to 1-nm precision with a range from 5 to 1000 nm. Thin films can be deposited on any surface including many widely used biomaterials. Microencapsulation of micro/nanotemplates with multilayers enabled cell surface modification, controlled drug release, hollow shell formation, and nanobioreactors. Both in vitro and in vivo studies indicate potential applications in biology, pharmaceutics, medicine, and other biomedical areas.

Biomimetic Materials↗

Reduction of coherent scattering noise with multiple receiver Doppler.

Doppler ultrasound (US) velocity estimates are inherently subject to error as a result of both Doppler ambiguity and coherent scattering. The coherent scattering error is a result of changes in the phase of the returned echo as particles enter and leave the sample volume. This phase depends on the distance from the transmitter to the scatterer and then to the receiver. This distance, in turn, depends on the angle of the receiver. A numerical simulation has been used to determine whether velocity estimates obtained from receiver probes at different angles are independent of one another. If so, then it is possible to obtain an improved velocity estimate from the combination of several receivers at different angles. The simulation results show that the cross-correlation between velocity estimates is reduced to 0.3 when receiver probes are oriented 5 degrees apart. These results suggest a new Doppler method that can significantly reduce velocity estimation error.

Fourier Analysis↗

Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses.

BACKGROUND: Intimal hyperplastic thickening (IHT) is a frequent cause of prosthetic bypass graft failure. Induction and progression of IHT is thought to involve a number of mechanisms related to variation in the flow field, injury and the prosthetic nature of the conduit. This study was designed to examine the relative contribution of wall shear stress and injury to the induction of IHT at defined regions of experimental end-to-side prosthetic anastomoses. METHODS AND RESULTS: The distribution of IHT was determined at the distal end-to-side anastomosis of seven canine Iliofemoral PTFE grafts after 12 weeks of implantation. An upscaled transparent model was constructed using the in vivo anastomotic geometry, and wall shear stress was determined at 24 axial locations from laser Doppler anemometry measurements of the near wall velocity under conditions of pulsatile flow similar to that present in vivo. The distribution of IHT at the end-to-side PTFE graft was determined using computer assisted morphometry. IHT involving the native artery ranged from 0.0+/-0.1 mm to 0.05+/-0.03 mm. A greater amount of IHT was found on the graft hood (PTFE) and ranged from 0.09+/-0.06 to 0.24+/-0.06 mm. Nonlinear multivariable logistic analysis was used to model IHT as a function of the reciprocal of wall shear stress, distance from the suture line, and vascular conduit type (i.e. PTFE versus host artery). Vascular conduit type and distance from the suture line independently contributed to IHT. An inverse correlation between wall shear stress and IHT was found only for those regions located on the juxta-anastomotic PTFE graft. CONCLUSIONS: The data are consistent with a model of intimal thickening in which the intimal hyperplastic pannus migrating from the suture line was enhanced by reduced levels of wall shear stress at the PTFE graft/host artery interface. Such hemodynamic modulation of injury induced IHT was absent at the neighboring artery wall.

Anastomosis, Surgical↗

Gelatin-glutaraldehyde cross-linking on silicone rubber to increase endothelial cell adhesion and growth.

Silicone is a biomaterial that is widely used in many areas because of its high optical clarity, its durability, and the ease with which it can be cast. However, these advantages are counterbalanced by strong hydrophobicity. Gelatin cross-linking has been used as a hydrophilic coating on many biomaterials but not on silicone rubber. In this study, two gelatin glutaraldehyde (GA) cross-linking methods were used to coat a hydrophilic membrane on silicone rubber. In method I, gelatin and GA were mixed in three different proportions (64:1, 128:1, and 256:1) before coating. In method II, a newly formed 5% gelatin membrane was cross-linked with a 2.5% GA solution. All coatings were hydrophilic, as determined from the measurement of contact angle for a drop of water on the surface. Bovine coronary arterial endothelial cells were shown to grow well on the surface modified by method II at 72 h. In method I, the cells grew well for gelatin-GA proportions of 64:1 and 128:1 at 72 h. No cell attachment on untreated silicone rubber was observed by the third d of seeding. The results indicated that both methods of gelatin-GA cross-linking provided a hydrophilic surface on silicone for endothelial cell adhesion and growth in vitro.

Animals↗

Electrostatic layer-by-layer nanoassembly on biological microtemplates: platelets.

Platelets were coated with 78-nm silica nanoparticles, 45-nm fluorescent nanospheres, or bovine immunoglobulin G (IgG) through layer-by-layer assembly by alternate adsorption with oppositely charged linear polyions. Sequential deposition on platelet surfaces of cationic poly(dimethyldiallylammonium chloride) and anionic poly(styrene sulfonate) was followed by adsorption of nanoparticles or immunoglobulins. Nano-organized shells of platelets were demonstrated by transmission electron microscopy and fluorescence microscope images. Bovine IgG was assembled on platelets, as verified with anti-bovine IgG-FITC labeling. Localized targeting of anti-IgG shelled platelets was also demonstrated. An ability to coat blood cells with nano-organized shells can have applications in cardiovascular research and targeted drug delivery.

Adsorption↗

Thresholds for significant decrease in hemodialysis access blood flow.

During hemodialysis access surveillance, referral for evaluation and correction of stenosis is based upon determination that a significant decrease in blood flow (Q) has occurred. However, criteria for determining when a decrease is statistically significant have not yet been established. In this study we established such criteria by analyzing Q variation with the glucose pump test (GPT). We took nine Q measurements in each of 25 patients (18 grafts, 7 fistulas) during three dialysis sessions within a 2-week period (predialysis and during hours 1 and 3). We determined thresholds that define a significant percentage decrease in Q (deltaQ) for various p values. In order to confirm the general applicability of these thresholds, we computed the average within-patient Q variation during the three sessions (computed as a coefficient of variation and referred to as short-term variation). We then determined the relative influences of biological (true) variation and analytical error on short-term variation. We found that deltaQ must be > 33% to be significant at p < 0.05, whereas the threshold is > 17% for p < 0.20. Measuring Q at uniform versus different times during the sessions did not significantly reduce these thresholds. We also found that biological variation was nearly as large as short-term Q variation, whereas analytical error contributed minimally to short-term variation. In conclusion, this study defines thresholds for a significant deltaQ that have wide application in determining access referral for evaluation and correction of stenosis. Selection of a particular threshold should consider the relative importance of avoiding thrombosis versus avoiding unnecessary procedures. If avoiding unnecessary procedures is a priority, then we recommend a threshold of > 33%. These thresholds apply to other methods of measuring Q, provided analytical error is significantly less than biological variation.

Arteriovenous Shunt, Surgical↗