Multi-layered PZT/polymer composites to increase signal-to-noise ratio and resolution for medical ultrasound transducers part II: thick film technology.

Increasing transducer bandwidth and signal-to-noise ratio (SNR) is fundamental to improving the quality of medical ultrasound images. In previous work, we have proposed the use of multi-layer 1-3 PZT/polymer composites to increase both, but have encountered significant fabrication challenges [19]. These difficulties include making the bond thickness between the layers small relative to the ultrasound wavelength and aligning the posts of the composite to increase coupling coefficient. Thus, we have developed a multi-layer composite hybrid array that will not require post alignment. Starting from a 2-MHz, three-layer PZT-5H, thick film transducer designed for 1.5-D arrays, cuts are made only through the top layer and back-filled with epoxy, forming a composite layer on top of two ceramic layers. Finite element (PZFlex) simulations show that for a 2-MHz phased-array element with a single matching layer, the three-layer hybrid structure increases the pulse echo SNR by 11 dB versus a single layer PZT element and improves -6 dB pulse echo fractional bandwidth by a factor of 1.4. Composite hybrid arrays fabricated in our laboratory showed an improvement in SNR of 6 to 11 dB over a PZT control and an increase in -6 dB bandwidth by a factor of 1.1. Images from a phased-array scanner confirmed these improvements.

Ceramics↗

Finite element comparison of single crystal vs. multi-layer composite arrays for medical ultrasound.

Finite element (PZFlex; Weidlinger Assoc., New York, NY and Los Altos, CA) simulations predict that for a 2-MHz phased array element with a single matching layer, the three-layer hybrid structure [1] increases the pulse echo signal-to-noise ratio (SNR) by 16 dB over that from a single layer PZT element and -6 dB pulse echo fractional bandwidth from 58% for the PZT element to 75% for the hybrid element. Analogous finite element method (FEM) simulations of single crystal material [lead zinc niobate (PZN)-8% lead titanate (PT)] showed increased SNR by only 3.1 dB, but a -6 dB bandwidth of 108%.

Ceramics↗

Feasibility study for real time three dimensional Doppler intracardiac echocardiography.

Using catheter-mounted two-dimensional array transducers, we have obtained real-time three-dimensional color flow and spectral Doppler ultrasound images in phantoms. We have constructed several transducers operating at 5 MHz with up to 137 channels inside a 12 French catheter lumen. The transducer configuration may be side scanning or beveled with respect to the long axis of the catheter lumen. We have also included six electrodes to acquire simultaneous electrocardiograms. We have measured Doppler signals in two phantoms, a string phantom and a pulsatile flow phantom. Using an open chest sheep model, we inserted the catheter into the cardiac chambers to study the utility of in vivo 3D intracardiac Doppler echocardiography.

Animals↗

Guidance of cardiac pacemaker leads using real time 3D ultrasound: feasibility studies.

We investigated the feasibility of the guidance of pacemaker lead implantation using the pacemaker lead stylet as an acoustic wave-guide combined with real time 3D ultrasound imaging. In one approach, with a 2.5 MHz transducer coupled to a stylet of a pacemaker lead, we used the stylet as a transmitter to track the vibrating tip in a 3D ultrasound scan. In another approach, we connected the stylet to a piezoelectric actuator vibrating in the range 0.5-5 kHz so that the tip of the stylet was imaged using the color Doppler feature of the real time 3D ultrasound scanner. In both approaches, tracking of the isolated stylet showed good accuracy. However, neither approach offered sufficient signal-to-noise ratio to detect the vibration within the lumen of an intact pacemaker lead.

Animals↗