Search PubMed⌕ Search

Biomedical subjects

Stephen Santangelo

Publications and source records attributed to Stephen Santangelo.

3 recordsLinked to original sources

Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair.

BACKGROUND: Recent technical improvements have led the way to a resurgence of the single-incision approach for repair of distal biceps tendon injuries. There has been no biomechanical evaluation of all these techniques with comparison to the standard 2-incision bone tunnel technique. HYPOTHESIS: There will be no difference under cyclic loading and ultimate failure between the 2-incision bone tunnel technique, suture anchor repair, interference screw, and EndoButton techniques for the repair of distal biceps tendon ruptures. STUDY DESIGN: Controlled laboratory study. METHODS: Sixty-three fresh-frozen cadaveric elbows were randomly assigned to 4 treatment groups (bone tunnel, EndoButton, suture anchor, interference screw). Cyclic loading was then performed from 0 degrees to 90 degrees at 0.5 Hz for 3600 cycles with a 50-N load. A differential variable reductance transducer was placed between the radius and distal tendon to determine displacement. The construct was then pulled to failure at 120 mm/min. RESULTS: A multiple analysis of variance revealed no statistically significant difference for displacement among the 4 repair techniques. Displacement using the bone tunnel was 3.55 mm, EndoButton was 3.42 mm, suture anchor was 2.33 mm, and interference screw was 2.15 mm. There was a statistically significant greater load to failure with EndoButton (440 N) than suture anchor (381 N), bone tunnel (310 N), or interference screw (232 N) (P < .001). CONCLUSION: The EndoButton technique had the highest load to failure. CLINICAL RELEVANCE: These data demonstrate the EndoButton to be the strongest repair technique, with no failures during cycling at physiologic loads and with the largest load to failure. These findings are important in maximizing surgical results and stability and suggest that the construct can tolerate early postoperative active range of motion.

Arm↗

Fetal pain.

Explore the source record for details and available documents.

Analgesia↗

The biomechanical evaluation of four fixation techniques for proximal biceps tenodesis.

PURPOSE: The purpose of this study was to compare the cyclic displacement and ultimate failure strength of 4 proximal biceps tendon tenodesis fixation methods: the open subpectoral bone tunnel (SBT) biceps tenodesis, the arthroscopic suture anchor (SA) tenodesis, the open subpectoral interference screw (SIS) fixation technique, and the arthroscopic interference screw (AIS) technique. TYPE OF STUDY: Biomechanical experimental control. METHODS: Twenty fresh-frozen cadaver shoulders were dissected free of soft tissues, leaving the proximal humerus and the proximal biceps tendon as a free graft. Specimens were randomized to 1 of 4 groups with 5 total specimens in each group. A proximal biceps tenodesis was performed according to the techniques listed above. The specimens were mounted for an axial pull of the biceps tendon on a servohydraulic materials testing system with a 100-N load cycled at 1 Hz for 5,000 cycles, followed by an axial load to failure test. Cyclic displacement, ultimate load to failure, and site of failure were recorded for each specimen. RESULTS: The mean cyclic displacement recorded for each experimental group was as follows: SBT group, 9.39 +/- 2.82 mm; AIS group, 5.26 +/- 2.60 mm; SIS group, 1.53 +/- 0.60 mm; and SA group, 3.87 +/- 2.11 mm. The mean ultimate failure loads after 5,000 cycles were as follows: SBT group, 242.4 +/- 51.33 N; AIS group, 237.6 +/- 27.58 N; SIS group, 252.4 +/- 68.63 N; and SA group, 164.8 +/- 37.47 N. Each specimen failed at the tenodesis site. CONCLUSIONS: The SBT group showed statistically significant greater displacement than the other tenodesis methods. There were no statistically significant differences in ultimate failure strength between any of the biceps tenodesis methods tested. CLINICAL RELEVANCE: The data serve as a guide to the surgeon performing a proximal biceps tenodesis in choosing a fixation method.

Aged↗