Clinical predictors of defibrillation thresholds with an active pectoral pulse generator lead system.

Active pectoral pulse generators are used routinely for initial ICD placement because they reduce DFTs and simplify the implantation procedure. Despite the common use of these systems, little is known regarding the clinical predictors of defibrillation efficacy with active pulse generator lead configurations. Such predictors would be helpful to identify patients likely to require higher output devices or more complicated implantations. This was a prospective evaluation of DFT using a uniform testing protocol in 102 consecutive patients with an active pectoral can and dual coil transvenous lead. For each patient, the DFT was measured with a step-down protocol. In addition, 34 parameters were assessed including standard clinical echocardiographic and radiographic measures. Multivariate stepwise regression analysis was performed to identify independent predictors of the DFT. The mean DFT was 9.3 +/- 4.6 J and 93% (95/102) of patients had a DFT < or = 15 J. The QRS duration, interventricular septum thickness, left ventricular mass, and mass index were significant but weak (R < 0.3) univariate predictors of DFT. The left ventricular mass was the only independent predictor by multivariate analysis, but this parameter accounted for < 5% of the variability of DFT measured (adjusted R2 = 0.047, P = 0.017). The authors concluded that an acceptable DFT (< 15 J) is observed in > 90% of patients with this dual coil and active pectoral can lead system. Clinical factors are of limited use for predicting DFTs and identifying those patients who will have high thresholds.

Aged↗

Lack of benefit of an active pectoral pulse generator on atrial defibrillation thresholds.

INTRODUCTION: Atrial defibrillation can be achieved with standard implantable cardioverter defibrillator leads, which has led to the development of combined atrial and ventricular devices. For ventricular defibrillation, use of an active pectoral electrode (active can) in the shocking pathway markedly reduces defibrillation thresholds (DFTs). However, the effect of an active pectoral can on atrial defibrillation is unknown. METHODS AND RESULTS: This study was a prospective, randomized, paired comparison of two shock configurations on atrial DFTs in 33 patients. The lead system evaluated was a dual-coil transvenous defibrillation lead with a left pectoral pulse generator emulator. Shocks were delivered either between the right ventricular coil and proximal atrial coil (lead) or between the right ventricular coil and an active can in common with the atrial coil (active can). Delivered energy at DFT was 4.2 +/- 4.1 J in the lead configuration and 5.0 +/- 3.7 J in the active can configuration (P = NS). Peak current was 32% higher with an active can (P < 0.01), whereas shock impedance was 18% lower (P < 0.001). Moreover, a low threshold (< or = 3 J) was observed in 61% of subjects in the lead configuration but in only 36% in the active can configuration (P < 0.05). There were no clinical predictors of the atrial DFT. CONCLUSION: These results indicate that low atrial DFTs can be achieved using a transvenous ventricular defibrillation lead. Because no benefit was observed with the use of an active pectoral electrode for atrial defibrillation, programmable shock vectors may be useful for dual-chamber implantable cardioverter defibrillators.

Atrial Fibrillation↗

Influence of QRS duration on the prognostic value of T wave alternans.

INTRODUCTION: T wave alternans (TWA) is a promising new noninvasive marker of arrhythmia vulnerability that quantifies beat-to-beat changes in ventricular repolarization. Secondary repolarization abnormalities are common in subjects with wide QRS complexes. However, the relationship between TWA and QRS prolongation has not been evaluated. The goal of this study was to determine if QRS prolongation influences the prevalence or prognostic value of TWA. METHODS AND RESULTS: The study consisted of 108 consecutive patients with coronary artery disease and left ventricular ejection fraction < or = 40% who were referred for electrophysiologic studies. Patients underwent TWA testing using bicycle ergometry in the absence of beta-blockers or antiarrhythmic drugs. The primary endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator therapy. The prognostic value of TWA was assessed in the entire cohort and in two subgroups: QRS < 120 msec (normal, n = 62) and QRS > or = 120 msec (prolonged, n = 46). TWA (hazard ratio 2.2, P = 0.03) and QRS prolongation (hazard ratio 2.2, P = 0.01) were both significant and independent predictors of arrhythmic events. QRS prolongation had no effect on the prevalence of positive TWA tests (QRS < 120 msec: 48%, QRS > or = 120 msec: 50%, P = NS). TWA was a highly significant predictor of events in patients with a normal QRS (hazard ratio 5.8, P = 0.02). In contrast, TWA was not useful for risk stratification in subjects with QRS prolongation (hazard ratio 1.1, P = 0.8). CONCLUSION: TWA is useful only for risk stratification in the absence of QRS prolongation. The presence of QRS prolongation and left ventricular ejection fraction < or = 40% may be sufficient evidence of an adverse prognosis that additional risk stratification is not useful or necessary.

Adult↗

Exercise is superior to pacing for T wave alternans measurement in subjects with chronic coronary artery disease and left ventricular dysfunction.

INTRODUCTION: T wave alternans (TWA) is a heart rate-dependent marker of vulnerability to ventricular arrhythmias. Atrial pacing and exercise both are used as provocative stimuli to elicit TWA. However, the prognostic value of the two testing methods has not been compared. The aim of this prospective study was to compare the prognostic value of TWA measured during bicycle exercise and atrial pacing in a large cohort of high-risk patients with ischemic heart disease and left ventricular dysfunction. METHODS AND RESULTS: This was a prospective study of 251 patients with coronary artery disease and left ventricular dysfunction who were referred for electrophysiologic studies (EPS) for standard clinical indications. Patients underwent TWA testing using bicycle ergometry (exercise TWA, n = 144) and/or atrial pacing (pacing TWA, n = 178). The primary endpoint was the combined incidence of death, sustained ventricular arrhythmias, and appropriate implantable cardioverter defibrillator therapy. The predictive value of exercise and pacing TWA for EPS results and for endpoint events was determined. Exercise and pacing TWA both were significant predictors of EPS results (odds ratios 3.0 and 2.9 respectively, P < 0.02). Kaplan-Meier survival analysis of the primary endpoint revealed that exercise TWA was a significant predictor of events (hazard ratio 2.2, P = 0.03). In contrast, pacing TWA had no prognostic value for endpoint events (hazard ratio 1.1, P = 0.8). CONCLUSION: TWA should be measured during exercise when it is used for clinical risk stratification. EPS results may not be an adequate surrogate for spontaneous events when evaluating new risk stratification tests.

Aged↗

Advanced rhythm discrimination for implantable cardioverter defibrillators using electrogram vector timing and correlation.

INTRODUCTION: Discrimination of ventricular and supraventricular arrhythmias remains one of the major challenges for appropriate implantable defibrillator (ICD) therapy delivery. The electrogram vector timing and correlation (VTC) algorithm was developed for such rhythm discrimination. The VTC algorithm differentiates normally conducted supraventricular beats from abnormally conducted ventricular beats by comparing the timing and correlation of rate and shock channel electrograms. METHODS AND RESULTS: Rate and shock channel electrograms of sinus rhythm and induced arrhythmias were collected from 93 patients during ICD placement. The algorithm was developed using data from 50 patients and prospectively tested in a software model with the remaining 43 patients. A sinus rhythm reference was formed by averaging complexes of the shock channel signal aligned by the peak amplitude of the rate channel. Eight features measuring the amplitude and timing of shock channel signal characteristics were extracted from the reference for comparison. When a high-rate rhythm was detected, the VTC algorithm computed the correlation of the arrhythmia complex features with the reference. Rhythms with a sufficient number of uncorrelated beats were classified as ventricular tachycardia (VT). In a dual-chamber implementation, the VTC algorithm is integrated with ventricular and atrial rate comparison (V>A) and stability above an atrial fibrillation rate threshold. The test set consisted of 117 arrhythmias. Dual-chamber sensitivity was 100% (81/81 VT) and specificity was 97% (35/36 supraventricular tachycardia). Single-chamber analysis demonstrated 99% sensitivity and 97% specificity. CONCLUSION: The VTC algorithm demonstrated high sensitivity and specificity in discriminating between ventricular and supraventricular arrhythmias.

Aged↗

Cardiovascular responses to repetitive defibrillation during implantable cardioverter-defibrillator testing.

OBJECTIVE: To study the effects of electrical applications and subsequent postshock hypotension on myocardial performance and vascular tone during implantable cardioverter-defibrillator (ICD) placement. DESIGN: Prospective, blinded, observational investigation. SETTING: Single, university-affiliated institution. PARTICIPANTS: Twenty patients undergoing elective ICD placement and testing under general anesthesia. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Serial measurements were made of hemodynamic variables, left ventricular end-systolic (ESA) and end-diastolic (EDA) areas, fractional-area-of-contraction (FAC), time of hypoperfusion (when mean arterial pressure < or =50 mmHg postshock), and applied conversion energy. Multiple linear regression was performed to determine correlations among collected variables, and repeated measures analysis of variance was used to compare mean values. Minimal changes were detected in mean values of arterial, pulmonary, and central venous pressures; cardiac output; heart rate; and mixed venous saturation during repeated testing. Percentage changes in cardiac index (CI) rose and systemic vascular resistance index (SVRI) fell, however, as the number of shocks increased, reaching significance at the seventh and eighth shocks (v baseline; both p = 0.015). The percentage change in CI was linearly related to hypoperfusion time and accumulated energy (%deltaCI = 1.553 + [0.068 x sigma hypoperfusion time [sec]], r = 0.92, p < 0.001; %deltaCI = 0.326 + [0.125 x sigma Energy [J]], r = 0.94, p < 0.001). The percentage change in SVRI was inversely related to hypoperfusion time and accumulated energy (%deltaSVRI = 2.195 - [0.122 x sigma energy [J]], r = 0.79, p = 0.004; %deltaSVRI = 0.542 - [0.0634 - sigma hypoperfusion time [sec]], r = 0.73, p = 0.01). Echocardiographic EDA, ESA, and FAC were not significantly changed but showed substantial variability. CONCLUSION: Hemodynamic stability was generally well maintained during ICD placement and testing. Increases in CI were associated with concurrent reductions in systemic afterload, rather than enhanced FAC. Increasing postshock hypotension and applied energy were associated with decreases in CI and systemic afterload. Insignificant, but highly variable, changes were noted echocardiographically.

Adult↗

Effect of shock polarity on the efficacy of transthoracic atrial defibrillation.

BACKGROUND: The energy requirement for internal ventricular defibrillation is reduced by reversal of shock polarity. The influence of shock polarity on the efficacy of transthoracic atrial defibrillation is unknown. METHODS: This prospective, randomized study enrolled 110 consecutive patients who were referred for elective cardioversion of persistent atrial fibrillation (AF). The electrodes were placed in the anteroposterior position. The patients were randomized to receive either standard (anterior pad = cathode) or reversed polarity (anterior pad = anode) shocks with a damped sinusoidal monophasic waveform. A step-up protocol was used to estimate the cardioversion threshold. The initial shock energy was 50 J, with subsequent increments to 100, 200, 300, and 360 J in the event of cardioversion failure. RESULTS: Sixty-four percent of the patient population were men, with a mean age of 66 +/- 13 years and a mean duration of AF of 242 +/- 556 days. The overall success rates of cardioversion were 84% for standard polarity and 78% for reversed polarity (P not significant). Among the patients who were successfully cardioverted, the mean atrial defibrillation threshold was 198 +/- 103 J for standard polarity and 212 +/- 107 J for reversed polarity (P not significant). CONCLUSIONS: Reversal of shock polarity does not improve transthoracic cardioversion efficacy with a standard damped sinusoidal monophasic waveform. Alternate strategies should be considered for patients who fail external cardioversion, such as adjunctive pharmacologic treatment, use of a biphasic shock waveform, or internal cardioversion.

Aged↗